1.
Opt Lett ; 40(13): 3165-8, 2015 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-26125393

RESUMO

We demonstrate a novel catheterscope, based on scanning fiber endoscopy, for volumetric imaging with optical coherence tomography (OCT), which possesses a high resonance frequency (>2 kHz) and a small outer diameter (OD) (1.07 mm). Our design is the fastest volumetric-scanning, forward-viewing catheterscope for OCT, and the scanning package has the smallest OD of any such OCT package published to date. Using a proof-of-operation catheterscope with commercial lenses, we demonstrate high-quality in vivo and ex vivo volumetric imaging and extend the 1.1 mm diameter field of view more than 200-fold by mosaicking. Due to its small OD, short rigid tip length, and fast scan rate, this scope is the leading candidate design to enable early detection and staging of bladder cancer during flexible white light cystoscopy.


Assuntos
Endoscópios , Tomografia de Coerência Óptica/instrumentação , Dedos , Humanos , Imageamento Tridimensional , Fatores de Tempo
2.
Lasers Surg Med ; 45(6): 391-400, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23740768

RESUMO

BACKGROUND AND OBJECTIVE: Regenerative medicine involves the bioengineering of a functional tissue or organ by seeding living cells on a biodegradable scaffold cultured in a bioreactor. A major barrier to creating functional tissues, however, has been the inability to monitor the dynamic and complex process of scaffold maturation in real time, making control and optimization extremely difficult. Current methods to assess maturation of bioengineered constructs, such as histology or organ bath physiology, are sample-destructive. Optical coherence tomography (OCT) has recently emerged as a key modality for structural assessment of native blood vessels as well as engineered vessel mimics. The objective of this study was to monitor and assess in real time the development of a bioengineered blood vessel using a novel approach of combining both free-space and catheter-based OCT imaging in a new quartz-walled bioreactor. Development of the blood vessel was characterized by changes in thickness and scattering coefficient over a 30-day period. MATERIALS AND METHODS: We constructed a novel blood vessel bioreactor utilizing a rotating cylindrical quartz cuvette permitting free-space OCT imaging of an installed vessel's outer surface. A vascular endoscopic OCT catheter was used to image the lumen of the vessels. The quartz cuvette permits 360 degree, free-space OCT imaging of the blood vessel. Bioengineered blood vessels were fabricated using biodegradable polymers (15% PCL/collagen, ∼300 µm thick) and seeded with CH3 10t1/2 mesenchymal stem cells. A swept-source OCT imaging system comprised of a 20 kHz tunable laser (Santec HSL2000) with 1,300 nm central wavelength and 110 nm FWHM bandwidth was used to assess the vessels. OCT images were obtained at days 1, 4, 7, 14, 21, and 30. Free-space (exterior surface) OCT images were co-registered with endoscopic OCT images to determine the vessel wall thickness. DAPI-stained histological sections, acquired at same time point, were evaluated to quantify wall thickness and cellular infiltration. Non-linear curve fitting of free-space OCT data to the extended Huygen-Fresnel model was performed to determine optical scattering properties. RESULTS: Vessel wall thickness increased from 435 ± 15 µm to 610 ± 27 µm and Vessel scattering coefficient increased from 3.73 ± 0.32 cm⁻¹ to 5.74 ± 0.06 cm⁻¹ over 30 days. Histological studies showed cell migration from the scaffold surface toward the lumen and cell proliferation over the same time course. The imaging procedure did not have any significant impact on scaffold dimensions, cell migration, or cell proliferation. CONCLUSIONS: This study suggests that combination of free-space and catheter-based OCT for blood vessel imaging provides accurate structural information of the developing blood vessel. We determined that free-space OCT images could be co-registered with catheter-based OCT images to monitor structural features such as wall thickness or delamination of the developing tissue-engineered blood vessel within a bioreactor. Structural parameters and optical properties obtained from OCT imaging correlate with histological sections of the blood vessel and could potentially be used as markers to non-invasively and non-destructively assess regeneration of engineered tissues in real time.


Assuntos
Reatores Biológicos , Vasos Sanguíneos , Engenharia Tecidual/métodos , Alicerces Teciduais , Tomografia de Coerência Óptica/métodos , Vasos Sanguíneos/anatomia & histologia , Vasos Sanguíneos/fisiologia , Catéteres , Movimento Celular , Proliferação de Células , Humanos , Células-Tronco Mesenquimais , Quartzo , Engenharia Tecidual/instrumentação , Tomografia de Coerência Óptica/instrumentação
3.
Int J Biomed Imaging ; 2011: 817250, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21837234

RESUMO

The highly disordered refractive index distribution in skin causes multiple scattering of incident light and limits optical imaging and therapeutic depth. We hypothesize that localized mechanical compression reduces scattering by expulsing unbound water from the dermal collagen matrix, increasing protein concentration and decreasing the number of index mismatch interfaces between tissue constituents. A swept-source optical coherence tomography (OCT) system was used to assess changes in thickness and group refractive index in ex vivo porcine skin, as well as changes in signal intensity profile when imaging in vivo human skin. Compression of ex vivo porcine skin resulted in an effective strain of -58.5%, an increase in refractive index from 1.39 to 1.50, and a decrease in water volume fraction from 0.66 to 0.20. In vivo OCT signal intensity increased by 1.5 dB at a depth of 1 mm, possibly due to transport of water away from the compressed regions. These finding suggest that local compression could be used to enhance light-based diagnostic and therapeutic techniques.

4.
J Biomed Opt ; 16(5): 051304, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21639564

RESUMO

The degree by which optical properties of tumors are altered following introduction of carbon nanotubes (CNTs) of varying concentration and type is poorly understood, making it difficult to predict the impact of CNT inclusion on the photothermal response to laser therapies. Optical properties were measured of phantoms representative of breast tumor tissue incorporated with multiwalled carbon nanotubes (MWNTs), single-walled carbon nanotubes (SWNTs), and single-walled carbon nanohorns (SWNHs) of varying concentration (0.01-0.1 mg/ml). Tissue phantoms were made from sodium alginate (3 g/ml) incorporated with polystyrene microbeads (3 µm diam and 1 mg/ml) and talc-France powder (40 mg/ml). Absorption (µ(a)) and reduced scattering (µ's) coefficients of phantoms containing CNTs were determined by the inverse adding-doubling algorithm for the wavelength range of 400-1300 nm. Optical properties of phantoms without CNTs were in the range of µ(a) = 1.04-0.06 mm(-1) and µ's' = 0.05-0.07 mm(-1) at a wavelength of 900 nm, which corresponds with published data for human breast tumor tissue. Incorporating MWNTs, SWNTs, and SWNHs in phantoms with a concentration of 0.1 mg/ml increased (µ(a)) by 20- to 30-fold, 5- to 6-fold, and 9- to 14-fold, respectively, for the wavelength range of 800-1100 nm with minimal change in µ's (1.2- to 1.3-fold). Introduction of CNTs into tissue phantoms increased absorption, providing a means to enhance photothermal therapy.


Assuntos
Neoplasias da Mama/patologia , Neoplasias da Mama/fisiopatologia , Nanotubos de Carbono/química , Nanotubos de Carbono/ultraestrutura , Tomografia de Coerência Óptica/instrumentação , Feminino , Humanos , Luz , Imagens de Fantasmas , Refratometria , Espalhamento de Radiação , Tomografia de Coerência Óptica/métodos
5.
Regen Med ; 4(2): 205-23, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19317641

RESUMO

AIM: Gap-junctional connexin43 (Cx43) has roles in multiple aspects of skin wound healing - including scarring. The aim here was to study the effects of a cell-permeant peptide from the Cx43 carboxyl-terminus (CT) on scarring and regeneration following cutaneous injury. MATERIALS & METHODS: The effects of Cx43 CT peptide were studied in mouse and pig models of cutaneous injury. The parameters assessed included neutrophil density, wound closure, granulation, regeneration and skin tensile properties. RESULTS: Cx43 CT-peptide prompted decreases in area of scar progenitor tissue and promoted restoration of dermal histoarchitecture and mechanical strength following wounding of skin. These changes in healing were preceded by peptide-induced reduction in inflammatory neutrophil infiltration and alterations in the organization of epidermal Cx43, including increased connexon aggregation. CONCLUSION: Cx43 CT peptide promotes regenerative healing of cutaneous wounds and may have applications in tissues other than skin, including heart, cornea and spinal cord.


Assuntos
Conexina 43/uso terapêutico , Fragmentos de Peptídeos/uso terapêutico , Cicatrização/efeitos dos fármacos , Animais , Cicatriz/patologia , Cicatriz/prevenção & controle , Camundongos , Regeneração , Pele/lesões , Suínos