Med Phys ; 2018 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-29905964

RESUMO

PURPOSE: In situ drug release concurrent with radiation therapy has been proposed to enhance the therapeutic ratio of permanent prostate brachytherapy. Both brachytherapy sources and brachytherapy spacers have been proposed as potential eluters to release compounds, such as nanoparticles or chemotherapeutic agents. The relative effectiveness of the approaches has not been compared yet. This work models the physical dose enhancement of implantable eluters in conjunction with brachytherapy to determine which delivery mechanism provides greatest opportunity to enhance the therapeutic ratio. MATERIALS AND METHODS: The combined effect of implanted eluters and radioactive sources were modeled in a manner that allowed the comparison of the relative effectiveness of different types of implantable eluters over a range of parameters. Prostate geometry, source, and spacer positions were extracted from treatment plans used for 125 I permanent prostate implants. Compound concentrations were calculated using steady-state solution to the diffusion equation including an elimination term characterized by the diffusion-elimination modulus (ϕb ). Does enhancement was assumed to be dependent on compound concentration up to a saturation concentration (csat ). Equivalent uniform dose (EUD) was used as an objective to determine the optimal configuration of eluters for a range of diffusion-elimination moduli, concentrations, and number of eluters. The compound delivery vehicle that produced the greatest enhanced dose was tallied for points in parameter space mentioned to determine the conditions under whether there are situations where one approach is preferable to the other. RESULTS: The enhanced effect of implanted eluters was calculated for prostate volumes from 14 to 45 cm3 , ϕb from 0.01 to 4 mm-1 , csat from 0.05 to 7.5 times the steady-state compound concentration released from the surface of the eluter. The number of used eluters (ne ) was simulated from 10 to 60 eluters. For the region of (csat , Φ)-space that results in a large fraction of the gland being maximally sensitized, compound eluting spacers or sources produce equal increase in EUD. In the majority of the remaining (csat , Φ)-space, eluting spacers result in a greater EUD than sources even where sources often produce greater maximal physical dose enhancement. Placing eluting implants in planned locations throughout the prostate results in even greater enhancement than using only source or spacer locations. CONCLUSIONS: Eluting brachytherapy spacers offer an opportunity to increase EUD during the routine brachytherapy process. Incorporating additional needle placements permits compound eluting spacer placement independent of source placement and thereby allowing a further increase in the therapeutic ratio. Additional work is needed to understand the in vivo spatial distribution of compound around eluters, and to incorporate time dependence of both compound release and radiation dose.

2.
Phys Med Biol ; 61(16): 5956-72, 2016 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-27435044

RESUMO

This paper demonstrates that optimization strategies derived from the field of compressed sensing (CS) improve computational performance in inverse treatment planning (ITP) for high-dose-rate (HDR) brachytherapy. Following an approach applied to low-dose-rate brachytherapy, we developed a reformulation of the ITP problem with the same mathematical structure as standard CS problems. Two greedy methods, derived from hard thresholding and subspace pursuit are presented and their performance is compared to state-of-the-art ITP solvers. Applied to clinical prostate brachytherapy plans speed-up by a factor of 56-350 compared to state-of-the-art methods. Based on a Wilcoxon signed rank-test the novel method statistically significantly decreases the final objective function value (p < 0.01). The optimization times were below one second and thus planing can be considered as real-time capable. The novel CS inspired strategy enables real-time ITP for HDR brachytherapy including catheter optimization. The generated plans are either clinically equivalent or show a better performance with respect to dosimetric measures.


Assuntos
Braquiterapia/métodos , Catéteres/normas , Neoplasias da Próstata/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Masculino , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...