Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 173
Filtrar
1.
Pract Radiat Oncol ; 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38977158

RESUMO

PURPOSE: Recent randomized trials have compared the efficacy and safety of stereotactic body radiation therapy (SBRT) with those of standard conventional external beam radiation therapy (cEBRT) for the treatment of painful spinal metastases. We conducted a composite analysis of these trials in order to inform current practice using pooled outcomes. METHODS AND MATERIALS: Data from each randomized trial were abstracted from the final publications with biologically effective doses (BEDs) recalculated for SBRT and cEBRT. Primary outcome measures were overall pain response (OR) and complete pain response (CR) rates at 1, 3, and 6 months and rates of vertebral compression fracture. Random effects models were used to estimate primary outcome measures, and meta-regression assessed the effect of BED. RESULTS: Four prospective randomized clinical trials published between 2018 and 2024 were included, with a total of 686 patients (383 and 303 in the SBRT and cEBRT groups, respectively). Dose and fraction (fx) number ranged from 24 Gy/1 fx to 48.5 Gy/10 fx for the SBRT group (median BED using an α-to-ß ratio of 10, 50 Gy) and from 8 Gy/1 fx to 30 Gy/10 fx for the cEBRT group (median BED using an α-to-ß ratio of 10, 28 Gy). The 1-, 3-, and 6-month OR rates for SBRT and cEBRT were similar: 53.6%, 52.4%, and 58.8% versus 48.4%, 47.9%, and 43.8%, respectively (p > .05). The 3-month CR rate was significantly higher for SBRT than for cEBRT (31.9% vs 14.8%; risk ratio, 2.26; 95% CI, 1.48-3.45; p < .001), but not the 6-month rate (34.4% vs 16.3%; risk ratio, 1.83; 95% CI, 0.74-4.53; p = .194). Vertebral compression fracture rates were similar at 17.3% and 18.4% for SBRT and cEBRT, respectively. No significant dose-dependent effect was observed with increasing BED for any efficacy or safety outcomes. CONCLUSIONS: OR rates are similar, but CR rates appear higher with SBRT than with cEBRT, yet no dose-dependent effects were identified despite approximately 1.8 × BED dose with SBRT.

2.
Front Oncol ; 14: 1357916, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39055555

RESUMO

In the current era of high-precision radiation therapy, real-time magnetic resonance (MR)-guided tracking of the tumor and organs at risk (OARs) is a novel approach that enables accurate and safe delivery of high-dose radiation. Organ tracking provides a general sense of the need for daily online adaptation but lacks precise information regarding exact dosimetry. To overcome this limitation, we developed the methodology for monitoring intrafraction motion with real-time MR-guided isodose line-based tracking of an OAR in combination with anatomic tumor-based tracking and reported the first case treated with this approach. An isolated para-aortic (PA) nodal recurrence from carcinosarcoma of the endometrium was treated with an ablative dose of 50 Gy in five fractions using MR-guided radiotherapy (MRgRT). This report demonstrates the feasibility, workflow, dosimetric constraints, and treatment paradigm for real-time isodose line-based OAR tracking and gating to enable an isotoxicity delivery approach. This innovative treatment strategy effectively tracked the intrafraction motion of both the target and OAR independently and enhanced the accuracy of structure localization in time and space with a more precise dosimetric evaluation.

3.
Med Phys ; 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38977285

RESUMO

BACKGROUND: The dynamic collimation system (DCS) provides energy layer-specific collimation for pencil beam scanning (PBS) proton therapy using two pairs of orthogonal nickel trimmer blades. While excellent measurement-to-calculation agreement has been demonstrated for simple cube-shaped DCS-trimmed dose distributions, no comparison of measurement and dose calculation has been made for patient-specific treatment plans. PURPOSE: To validate a patient-specific quality assurance (PSQA) process for DCS-trimmed PBS treatment plans and evaluate the agreement between measured and calculated dose distributions. METHODS: Three intracranial patient cases were considered. Standard uncollimated PBS and DCS-collimated treatment plans were generated for each patient using the Astroid treatment planning system (TPS). Plans were recalculated in a water phantom and delivered at the Miami Cancer Institute (MCI) using an Ion Beam Applications (IBA) dedicated nozzle system and prototype DCS. Planar dose measurements were acquired at two depths within low-gradient regions of the target volume using an IBA MatriXX ion chamber array. RESULTS: Measured and calculated dose distributions were compared using 2D gamma analysis with 3%/3 mm criteria and low dose threshold of 10% of the maximum dose. Median gamma pass rates across all plans and measurement depths were 99.0% (PBS) and 98.3% (DCS), with a minimum gamma pass rate of 88.5% (PBS) and 91.2% (DCS). CONCLUSIONS: The PSQA process has been validated and experimentally verified for DCS-collimated PBS. Dosimetric agreement between the measured and calculated doses was demonstrated to be similar for DCS-collimated PBS to that achievable with noncollimated PBS.

4.
J Clin Nurs ; 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38873883

RESUMO

AIMS AND OBJECTIVES: To determine the effect of immersive virtual reality (VR) on perceived pain and fear in children during vaccination and parental satisfaction with the procedure. BACKGROUND: Virtual reality can reduce the perception of pain by children but only three studies have analysed its use during vaccination to date; these had small sample sizes and imperfect methodological designs. DESIGN: A randomised controlled clinical trial. METHODS: One hundred and sixty participants from the Tres Forques Health Center were randomly assigned to the intervention group (IG) (n = 82) in which distraction with immersive VR was used during the vaccination, while standard distraction techniques were used for the control group (n = 80). The primary outcome was pain (Wong-Baker FACES). Secondary outcomes included (Children's Fear Scale) and parental satisfaction with the vaccination procedure. Chi-squared tests were used for qualitative variables, relationships between quantitative variables were tested with Spearman correlations, and Mann-Whitney U- or Student t-tests were employed to assess the relationship between quantitative and qualitative variables. RESULTS: Compared to the controls, the children in the IG reported significantly less pain and fear, while parental satisfaction was significantly higher. Reported pain and fear did not differ according to the sex of the patient. Child age was not linked to fear but was related to pain: the younger the patient, the greater the pain they described. CONCLUSIONS: Immersive VR effectively controlled pain and fear in children during vaccination and increased parent satisfaction with the vaccination process. Patient sex did not influence the level of pain and fear but age did. RELEVANCE TO CLINICAL PRACTICE: Improving vaccination experiences can reduce perceived pain and fear in children and increase parent satisfaction, thereby enhancing vaccination schedule adherence and improving group immunity. REPORTING METHOD: The CONSORT Statement for non-pharmacological randomised clinical trials were followed.

5.
J Neurooncol ; 169(1): 105-117, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38837019

RESUMO

INTRODUCTION: This study compares four management paradigms for large brain metastasis (LMB): fractionated SRS (FSRS), staged SRS (SSRS), resection and postoperative-FSRS (postop-FSRS) or preoperative-SRS (preop-SRS). METHODS: Patients with LBM (≥ 2 cm) between July 2017 and January 2022 at a single tertiary institution were evaluated. Primary endpoints were local failure (LF), radiation necrosis (RN), leptomeningeal disease (LMD), a composite of these variables, and distant intracranial failure (DIF). Gray's test compared cumulative incidence, treating death as a competing risk with a random survival forests (RSF) machine-learning model also used to evaluate the data. RESULTS: 183 patients were treated to 234 LBMs: 31.6% for postop-FSRS, 28.2% for SSRS, 20.1% for FSRS, and 20.1% for preop-SRS. The overall 1-year composite endpoint rates were comparable (21 vs 20%) between nonoperative and operative strategies, but 1-year RN rate was 8 vs 4% (p = 0.012), 1-year overall survival (OS) was 48 vs. 69% (p = 0.001), and 1-year LMD rate was 5 vs 10% (p = 0.052). There were differences in the 1-year RN rates (7% FSRS, 3% postop-FSRS, 5% preop-SRS, 10% SSRS, p = 0.037). With RSF analysis, the out-of-bag error rate for the composite endpoint was 47%, with identified top-risk factors including widespread extracranial disease, > 5 total lesions, and breast cancer histology. CONCLUSION: This is the first study to conduct a head-to-head retrospective comparison of four SRS methods, addressing the lack of randomized data in LBM literature amongst treatment paradigms. Despite patient characteristic trends, no significant differences were found in LF, composite endpoint, and DIF rates between non-operative and operative approaches.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Humanos , Radiocirurgia/métodos , Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/mortalidade , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Adulto , Resultado do Tratamento , Taxa de Sobrevida , Seguimentos
6.
Int J Radiat Oncol Biol Phys ; 119(4): 1285-1296, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38925768

RESUMO

PURPOSE: Significant improvements within radioembolization imaging and dosimetry permit the development of an accurate and personalized pretreatment plan using technetium 99m-labeled macroaggregated albumin (99mTc-MAA) and single-photon emission computed tomography (SPECT) combined with anatomical CT (SPECT/CT). Despite these potential advantages, the clinical transition to pretreatment protocols with SPECT/CT is hindered by their unknown safety constraints. This study aimed to address this issue by establishing novel dose limits for 99mTc-MAA SPECT/CT to enable quantitative pretreatment planning. METHODS AND MATERIALS: Stratification criteria to determine images most viable for dosimetry analysis were created from a cohort of 85 patients. SPECT/CT, cone beam CT, and activity calculations derived from the local deposition method were used to create an accurate pretreatment protocol. Planar and SPECT/CT images were compared using linear regression and modified Bland-Altman analyses to convert accepted planar dose limits to SPECT/CT. To validate these new dose limits, activity calculations based on SPECT/CT were compared with those calculated with the body surface area and planar methods for three treatment plans. RESULTS: A total of 38 of 85 patients were deemed viable for dosimetry analysis. SPECT yielded greater lung shunt fractions (LSFs) than planar imaging when LSFs were <4.89%, whereas SPECT yielded lower LSFs than planar imaging when LSFs were >4.89%. Planar to SPECT/CT dose conversions were 0.76×, 0.70×, and 0.55× for the whole liver, normal liver, and lungs, respectively. Patients with SPECT LSFs ≤4.89% were safely treated with the direct application of planar lung dose limits. Activity calculations with the newly established SPECT/CT dose limits were greater than those of the body surface area method by a median range of 33.1% to 61.9% and were lower than planar-based activity calculations by a median range of 12.5% to 13.7% for the whole liver and by 29.4% to 32.2% for the normal liver. CONCLUSIONS: This study demonstrated a safe method for translating dose limits from 99mTc-MAA planar imaging to SPECT/CT. A robust pretreatment protocol was further developed guided by the current knowledge in the field. Established SPECT/CT dose limits safely treated 97.5% of patients and permitted the application of independent pretreatment planning with 99mTc-MAA SPECT/CT.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Agregado de Albumina Marcado com Tecnécio Tc 99m , Humanos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Embolização Terapêutica/métodos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Compostos Radiofarmacêuticos , Idoso de 80 Anos ou mais , Superfície Corporal , Tomografia Computadorizada de Feixe Cônico/métodos
7.
Front Oncol ; 14: 1358487, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38863634

RESUMO

Introduction: The ability to dynamically adjust target contours, derived Boolean structures, and ultimately, the optimized fluence is the end goal of online adaptive radiotherapy (ART). The purpose of this work is to describe the necessary tests to perform after a software patch installation and/or upgrade for an established online ART program. Methods: A patch upgrade on a low-field MR Linac system was evaluated for post-software upgrade quality assurance (QA) with current infrastructure of ART workflow on (1) the treatment planning system (TPS) during the initial planning stage and (2) the treatment delivery system (TDS), which is a TPS integrated into the delivery console for online ART planning. Online ART QA procedures recommended for post-software upgrade include: (1) user interface (UI) configuration; (2) TPS beam model consistency; (3) segmentation consistency; (4) dose calculation consistency; (5) optimizer robustness consistency; (6) CT density table consistency; and (7) end-to-end absolute ART dose and predicted dose measured including interruption testing. Differences of calculated doses were evaluated through DVH and/or 3D gamma comparisons. The measured dose was assessed using an MR-compatible A26 ionization chamber in a motion phantom. Segmentation differences were assessed through absolute volume and visual inspection. Results: (1) No UI configuration discrepancies were observed. (2) Dose differences on TPS pre-/post-software upgrade were within 1% for DVH metrics. (3) Differences in segmentation when observed were small in general, with the largest change noted for small-volume regions of interest (ROIs) due to partial volume impact. (4) Agreement between TPS and TDS calculated doses was 99.9% using a 2%/2-mm gamma criteria. (5) Comparison between TPS and online ART plans for a given patient plan showed agreement within 2% for targets and 0.6 cc for organs at risk. (6) Relative electron densities demonstrated comparable agreement between TPS and TDS. (7) ART absolute and predicted measured end-to-end doses were within 1% of calculated TDS. Discussion: An online ART QA program for post-software upgrade has been developed and implemented on an MR Linac system. Testing mechanics and their respective baselines may vary across institutions, but all necessary components for a post-software upgrade QA have been outlined and detailed. These outlined tests were demonstrated feasible for a low-field MR Linac system; however, the scope of this work may be applied and adapted more broadly to other online ART platforms.

8.
Rev. esp. cardiol. (Ed. impr.) ; 77(5): 396-407, mayo 2024. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-JHG-73

RESUMO

Introducción y objetivos: Existen pocos datos acerca del impacto pronóstico de una clase funcional NYHA III-IV después del implante percutáneo de válvula aórtica (TAVI). El objetivo del estudio fue determinar la incidencia, los predictores y las implicaciones pronósticas de una clase NYHA III-IV al mes del TAVI.MétodosEstudio multicéntrico que incluyó a 3.462 pacientes sometidos a TAVI que recibieron dispositivos de nueva generación. Se compararon pacientes en clase funcional NYHA I-II frente a pacientes en clase NYHA III-IV al mes de seguimiento. Los predictores de clase NYHA III-IV a un mes se identificaron mediante regresión logística multivariante. La supervivencia se evaluó con el método de Kaplan-Meier y los factores asociados a peor pronóstico se identificaron mediante la regresión de Cox.ResultadosLa edad media de la población de estudio era de 80,3±7,3 años, con el 47% de mujeres y un valor mediano en la escala de la Society of Thoracic Surgeons del 3,8% [IQR, 2,5-5,8]). Un total de 208 pacientes (6%) presentaron NYHA III-IV al mes del TAVI. Los predictores de NYHA III-IV al mes fueron: NYHA basal III-IV (OR=1,76; IC95%, 1,08-2,89; p=0,02), enfermedad pulmonar obstructiva crónica (OR=1,80; IC95%, 1,13-2,83; p=0,01) e insuficiencia mitral severa post-TAVI (OR=2,00; IC95%, 1,21-3,31; p<0,01). Los pacientes en NYHA III-IV al mes del TAVI tenían un mayor riesgo de muerte (HR=3,68; IC95%, 2,39-5,70; p<0,01) y hospitalización por insuficiencia cardiaca (HR=6,00; IC95%, 3,76-9,60; p<0,01) durante el año que siguió al TAVI. (AU)


Introduction and objectives: There are scarce data on the factors associated with impaired functional status after transcatheter aortic valve replacement (TAVR) and its clinical impact. This study aimed to determine the incidence, predictors, and prognostic implications of impaired functional class (NYHA class III-IV) following TAVR.MethodsThis multicenter study included 3462 transarterial TAVR patients receiving newer generation devices. The patients were compared according to their NYHA class at 1 month of follow-up (NYHA I-II vs NYHA III-IV). A multivariate logistic regression was performed to identify the predictors of 30-day NYHA class III-IV. Patient survival was compared with the Kaplan-Meier method and factors associated with decreased survival were identified with Cox regression analysis.ResultsThe mean age of the study population was 80.3±7.3 years, with 47% of women, and a median Society of Thoracic Surgeons score of 3.8% [IQR, 2.5-5.8]. A total of 208 patients (6%) were in NYHA class III-IV 1 month after TAVR. Predictors of 30-day NYHA class III-IV were baseline NYHA class III-IV (OR, 1.76; 95%CI, 1.08-2.89; P=.02), chronic pulmonary obstructive disease (OR, 1.80; 95%CI, 1.13-2.83; P=.01), and post-TAVR severe mitral regurgitation (OR, 2.00; 95%CI, 1.21-3.31; P<.01). Patients in NYHA class III-IV 1 month after TAVR were at higher risk of death (HR, 3.68; 95%CI, 2.39-5.70; P<.01) and heart failure-related hospitalization (HR, 6.00; 95%CI, 3.76-9.60; P<.01) at 1-year follow-up. (AU)


Assuntos
Humanos , Valva Aórtica/cirurgia , Complicações Pós-Operatórias , Taxa de Sobrevida/tendências , Fatores de Tempo , Seguimentos , Fatores de Risco
9.
Med Dosim ; 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38431501

RESUMO

Single-fraction stereotactic radiosurgery (SRS) or fractionated SRS (FSRS) are well established strategies for patients with limited brain metastases. A broad spectrum of modern dedicated platforms are currently available for delivering intracranial SRS/FSRS; however, SRS/FSRS delivered using traditional CT-based platforms relies on the need for diagnostic MR images to be coregistered to planning CT scans for target volume delineation. Additionally, the on-board image guidance on traditional platforms yields limited inter-fraction and intra-fraction real-time visualization of the tumor at the time of treatment delivery. MR Linacs are capable of obtaining treatment planning MR and on-table MR sequences to enable visualization of the targets and organs-at-risk and may subsequently help identify anatomical changes prior to treatment that may invoke the need for on table treatment adaptation. Recently, an MR-guided intracranial package (MRIdian A3i BrainTxTM) was released for intracranial treatment with the ability to perform high-resolution MR sequences using a dedicated brain coil and cranial immobilization system. The objective of this report is to provide, through the experience of our first patient treated, a comprehensive overview of the clinical application of our institutional program for FSRS adaptive delivery using MRIdian's A3i BrainTx system-highlights include reviewing the imaging sequence selection, workflow demonstration, and details in its delivery feasibility in clinical practice, and dosimetric outcomes.

10.
Eur. j. psychiatry ; 38(1): [100227], Jan.-Mar. 2024. graf
Artigo em Inglês | IBECS | ID: ibc-229233

RESUMO

Background and objectives Suicide is a major public health concern, media can influence its awareness, contagion, and prevention. In this study, we evaluated the relationship between the COVID-19 pandemic and suicide in media coverage through Natural Language Processing analysis (NPL). Methods To study how suicide is depicted in news media, Artificial Intelligence and Big Data techniques were used to analyze news and tweets, to extract or classify the topic to which they belonged. Results A granger causality analysis showed with significant p-value that an increase in covid news at the beginning of the pandemic explains a later rise in suicide-related news. An analysis based on correlation and structural causal models show a strong relationship between the appearance of subjects “health” and “covid”, and also between “covid” and “suicide”. Conclusions Our analysis also uncovers that the inclusion of suicide-related news in the category health has grown since the outbreak of the pandemic. The COVID-19 pandemic has posed an inflection point in the way suicide-related news are reported. Our study found that the increased media attention on suicide during the COVID-19 pandemic may indicate rising social awareness of suicide and mental health, which could lead to the development of new prevention tools. (AU)


Assuntos
Humanos , Saúde Pública , Suicídio , Big Data , Inteligência Artificial , Aprendizado de Máquina , Meios de Comunicação , Rede Social , Processamento Eletrônico de Dados
12.
Tomography ; 10(1): 169-180, 2024 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-38250959

RESUMO

Radiotherapy for ultracentral lung tumors represents a treatment challenge, considering the high rates of high-grade treatment-related toxicities with stereotactic body radiation therapy (SBRT) or hypofractionated schedules. Accelerated hypofractionated magnetic resonance-guided adaptive radiation therapy (MRgART) emerged as a potential game-changer for tumors in these challenging locations, in close proximity to central organs at risk, such as the trachea, proximal bronchial tree, and esophagus. In this series, 13 consecutive patients, predominantly male (n = 9), with a median age of 71 (range (R): 46-85), underwent 195 MRgART fractions (all 60 Gy in 15 fractions) to metastatic (n = 12) or primary ultra-central lung tumors (n = 1). The median gross tumor volumes (GTVs) and planning target volumes (PTVs) were 20.72 cc (R: 0.54-121.65 cc) and 61.53 cc (R: 3.87-211.81 cc), respectively. The median beam-on time per fraction was 14 min. Adapted treatment plans were generated for all fractions, and indications included GTV/PTV undercoverage, OARs exceeding tolerance doses, or both indications in 46%, 18%, and 36% of fractions, respectively. Eight patients received concurrent systemic therapies, including immunotherapy (four), chemotherapy (two), and targeted therapy (two). The crude in-field loco-regional control rate was 92.3%. No CTCAE grade 3+ toxicities were observed. Our results offer promising insights, suggesting that MRgART has the potential to mitigate toxicities, enhance treatment precision, and improve overall patient care in the context of ultracentral lung tumors.


Assuntos
Neoplasias Pulmonares , Planejamento da Radioterapia Assistida por Computador , Humanos , Imageamento por Ressonância Magnética , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Espectroscopia de Ressonância Magnética
13.
J Perinat Neonatal Nurs ; 38(1): E3-E13, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37319350

RESUMO

BACKGROUND: Nursing and midwifery students do not feel adequately prepared during their clinical training to support women who breastfeed, demanding more effective communication skills and knowledge. AIM: The aim was to evaluate changes in students' breastfeeding knowledge. METHODS: This was a mixed-methods quasi-experimental design. Forty students voluntarily participated. Using a 1:1 ratio, 2 groups were randomly created and completed the validated questionnaire ECoLaE (pre-post). The educational program consisted of focus groups, a clinical simulation, and a visit to the local breastfeeding association. FINDINGS: The control group's posttest scores ranged from 6 to 20 (mean = 13.1, standard deviation [SD] = 3.0). The intervention group ranged from 12 to 20 (mean = 17.3, SD = 2.3). A Student's t test for independence samples was calculated ( P < .005, t = 4.5, median = 4.2). The intervention group had a mean difference of 10 points in improvement (mean =10.53, SD = 2.20, min = 7, max = 14), whereas the control group had a mean of 6 points (mean = 6.80, SD = 3.03, min = 3, max = 13). The multiple linear regression explained the intervention's effect. The regression model had statistical significance ( F = 4.87, P = 0.004), with an adjusted R2 = 0.31. The linear regression between the posttest scores and group variables after adjusting by age showed an increment of 4.1 points in the intervention posttest scores ( P < .005, 95% confidence interval [CI] = 2.1-6.1). CONCLUSIONS: The educational program "Engage in breaking the barriers to breastfeeding" improved nursing students' knowledge.


Assuntos
Bacharelado em Enfermagem , Estudantes de Enfermagem , Humanos , Feminino , Aleitamento Materno , Inquéritos e Questionários , Grupos Focais , Projetos de Pesquisa
14.
Int J Radiat Oncol Biol Phys ; 118(2): 512-524, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37793574

RESUMO

PURPOSE: This is the first reporting of the MRIdian A3iTM intracranial package (BrainTxTM) and benchmarks the end-to-end localization and dosimetric accuracy for commissioning an magnetic resonace (MR)-guided stereotactic radiosurgery program. We characterized the localization accuracy between MR and radiation (RT) isocenter through an end-to-end hidden target test, relative dose profile intercomparison, and absolute dose validation. METHODS AND MATERIALS: BrainTx consists of a dedicated head coil, integrated mask immobilization system, and high-resolution MR sequences. Coil and baseplate attenuation was quantified. An in-house phantom (Cranial phantOm foR magNetic rEsonance Localization of a stereotactIc radiosUrgery doSimeter, CORNELIUS) was developed from a mannequin head filled with silicone gel, film, and MR BB with pinprick. A hidden target test evaluated MR-RT localization of the 1×1×1 mm3 TrueFISP MR and relative dose accuracy in film for a 1 cm diameter (International Electrotechnical Commission (IEC)-X/IEC-Y) and 1.5 cm diameter (IEC-Y/IEC-Z) spherical target. Two clinical cases (irregular-shaped target and target abutting brainstem) were mapped to the CORNELIUS phantom for feasibility assessment. A 2-dimensional (2D)-gamma compared calculated and measured dose for spherical and clinical targets with 1 mm/1% and 2 mm/2% criteria, respectively. A small-field chamber (A26MR) measured end-to-end absolute dose for a 1 cm diameter target. RESULTS: Coil and baseplate attenuation were 0.7% and 2.7%, respectively. The displacement of MR to RT localization as defined through the pinprick was 0.49 mm (IEC-X), 0.27 mm (IEC-Y), and 0.51 mm (IEC-Z) (root mean square 0.76 mm). The reproducibility across IEC-Y demonstrated high fidelity (<0.02 mm). Gamma pass rates were 97.1% and 95.4% for 1 cm and 1.5 cm targets, respectively. Dose profiles for an irregular-shaped target and abutting organ-at-risk-target demonstrated pass rates of 99.0% and 92.9%, respectively. The absolute end-to-end dose difference was <1%. CONCLUSIONS: All localization and dosimetric evaluation demonstrated submillimeter accuracy, per the TG-142, TG-101, MPPG 9.a. criteria for SRS/SRT systems, indicating acceptable delivery capabilities with a 1 mm setup margin.


Assuntos
Radiocirurgia , Humanos , Radiocirurgia/métodos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Aceleradores de Partículas , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Espectroscopia de Ressonância Magnética
15.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38000627

RESUMO

INTRODUCTION AND OBJECTIVES: There are scarce data on the factors associated with impaired functional status after transcatheter aortic valve replacement (TAVR) and its clinical impact. This study aimed to determine the incidence, predictors, and prognostic implications of impaired functional class (NYHA class III-IV) following TAVR. METHODS: This multicenter study included 3462 transarterial TAVR patients receiving newer generation devices. The patients were compared according to their NYHA class at 1 month of follow-up (NYHA I-II vs NYHA III-IV). A multivariate logistic regression was performed to identify the predictors of 30-day NYHA class III-IV. Patient survival was compared with the Kaplan-Meier method and factors associated with decreased survival were identified with Cox regression analysis. RESULTS: The mean age of the study population was 80.3±7.3 years, with 47% of women, and a median Society of Thoracic Surgeons score of 3.8% [IQR, 2.5-5.8]. A total of 208 patients (6%) were in NYHA class III-IV 1 month after TAVR. Predictors of 30-day NYHA class III-IV were baseline NYHA class III-IV (OR, 1.76; 95%CI, 1.08-2.89; P=.02), chronic pulmonary obstructive disease (OR, 1.80; 95%CI, 1.13-2.83; P=.01), and post-TAVR severe mitral regurgitation (OR, 2.00; 95%CI, 1.21-3.31; P<.01). Patients in NYHA class III-IV 1 month after TAVR were at higher risk of death (HR, 3.68; 95%CI, 2.39-5.70; P<.01) and heart failure-related hospitalization (HR, 6.00; 95%CI, 3.76-9.60; P<.01) at 1-year follow-up. CONCLUSIONS: Up to 6% of contemporary TAVR patients exhibited an impaired functional status following TAVR. Worse baseline NYHA class, chronic pulmonary obstructive disease, and severe mitral regurgitation predicted 30-day NYHA class III/IV, and this determined a higher risk of mortality and heart failure hospitalization at 1-year follow-up. Further studies on the prevention and treatment optimization of patients with impaired functional status after TAVR are needed.

16.
Med Dosim ; 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-38001010

RESUMO

Advances in radiotherapy (RT) technologies permit significant decreases in the dose delivered to organs at risk (OARs) for patients with esophageal cancer (EC). Novel RT modalities such as proton beam therapy (PBT) and magnetic resonance-guided radiotherapy (MRgRT), as well as motion management techniques including breath hold (BH) are expected to further improve the therapeutic ratio. However, to our knowledge, the dosimetric benefits of PBT vs MRgRT vs volumetric-modulated arc therapy (VMAT) have not been directly compared for EC. We performed a retrospective in silico evaluation using the images and datasets of nine distal EC patients who were treated at our institution with a 0.35-Tesla MR linac to 50.4 Gy in 28 fractions in mid-inspiration BH (BH-MRgRT). Comparison free-breathing (FB) intensity-modulated PBT (FB-IMPT) and FB-VMAT plans were retrospectively created using the same prescription dose, target volume coverage goals, and OAR constraints. A 5 mm setup margin was used for all plans. BH-IMPT and BH-VMAT plans were not evaluated as they would not reflect our institutional practice. Planners were blinded to the results of the treatment plans created using different radiation modalities. The primary objective was to compare plan quality, target volume coverage, and OAR doses. All treatment plans met pre-defined target volume coverage and OAR constraints. The median conformity and homogeneity indices between FB-IMPT, BH-MRgRT and FB-VMAT were 1.13, 1.25, and 1.43 (PITV) and 1.04, 1.15, 1.04 (HI), respectively. For FB-IMPT, BH-MRgRT and FB-VMAT the median heart dose metrics were 52.8, 79.3, 146.8 (V30Gy, cc), 35.5, 43.8, 77.5 (V40Gy, cc), 16.9, 16.9, 32.5 (V50Gy, cc) and 6.5, 14.9, 17.3 (mean, Gy), respectively. Lung dose metrics were 8.6, 7.9, 18.5 (V20Gy, %), and 4.3, 6.3, 11.2 (mean, Gy), respectively. The mean liver dose (Gy) was 6.5, 19.6, 22.2 respectively. Both FB-IMPT and BH-MRgRT achieve substantial reductions in heart, lung, and liver dose compared to FB-VMAT. We plan to evaluate dosimetric outcomes across these RT modalities assuming consistent use of BH.

17.
Biomed Phys Eng Express ; 9(6)2023 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-37832529

RESUMO

Objective.To integrate a Dynamic Collimation System (DCS) into a pencil beam scanning (PBS) proton therapy system and validate its dosimetric impact.Approach.Uncollimated and collimated treatment fields were developed for clinically relevant targets using an in-house treatment plan optimizer and an experimentally validated Monte Carlo model of the DCS and IBA dedicated nozzle (DN) system. The dose reduction induced by the DCS was quantified by calculating the mean dose in 10- and 30-mm two-dimensional rinds surrounding the target. A select number of plans were then used to experimentally validate the mechanical integration of the DCS and beam scanning controller system through measurements with the MatriXX-PT ionization chamber array and EBT3 film. Absolute doses were verified at the central axis at various depths using the IBA MatriXX-PT and PPC05 ionization chamber.Main results.Simulations demonstrated a maximum mean dose reduction of 12% for the 10 mm rind region and 45% for the 30 mm rind region when utilizing the DCS. Excellent agreement was observed between Monte Carlo simulations, EBT3 film, and MatriXX-PT measurements, with gamma pass rates exceeding 94.9% for all tested plans at the 3%/2 mm criterion. Absolute central axis doses showed an average verification difference of 1.4% between Monte Carlo and MatriXX-PT/PPC05 measurements.Significance.We have successfully dosimetrically validated the delivery of dynamically collimated proton therapy for clinically relevant delivery patterns and dose distributions with the DCS. Monte Carlo simulations were employed to assess dose reductions and treatment planning considerations associated with the DCS.


Assuntos
Terapia com Prótons , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Imagens de Fantasmas , Radiometria
19.
Radiother Oncol ; 188: 109869, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37657726

RESUMO

BACKGROUND AND PURPOSE: Planning on a static dataset that reflects the simulation day anatomy is routine for SBRT. We hypothesize the quality of on-table adaptive plans is similar to the baseline plan when delivering stereotactic MR-guided adaptive radiotherapy (SMART) for pancreatic cancer (PCa). MATERIALS AND METHODS: Sixty-seven inoperable PCa patients were prescribed 50 Gy/5-fraction SMART. Baseline planning included: 3-5 mm gastrointestinal (GI) PRV, 50 Gy optimization target (PTVopt) based on GI PRV, conformality rings, and contracted GTV to guide the hotspot. For each adaptation, GI anatomy was re-contoured, followed by re-optimization. Plan quality was evaluated for target coverage (TC = PTVopt V100%/volume), PTV D90% and D80%, homogeneity index (HI = PTVopt D2%/D98%), prescription isodose/target volume (PITV), low-dose conformity (D2cm = maximum dose at 2 cm from PTVopt/Rx dose), and gradient index (R50%=50% Rx isodose volume/PTVopt volume).A novel global planning metric, termed the Pancreas Adaptive Radiotherapy Score (PARTS), was developed and implemented based on GI OAR sparing, PTV/GTV coverage, and conformality. Adaptive robustness (baseline to fraction 1) and stability (difference between two fractions with highest GI PRV variation) were quantified. RESULTS: OAR constraints were met on all baseline (n = 67) and adaptive (n = 318) plans. Coverage for baseline/adaptive plans was mean ± SD at 44.9 ± 5.8 Gy/44.3 ± 5.5 Gy (PTV D80%), 50.1 ± 4.2 Gy/49.1 ± 4.7 Gy (PTVopt D80%), and 80%±18%/74%±18% (TC), respectively. Mean homogeneity and conformality for baseline/adaptive plans were 0.87 ± 0.25/0.81 ± 0.30 (PITV), 3.81 ± 1.87/3.87 ± 2.0 (R50%), 1.53 ± 0.23/1.55 ± 0.23 (HI), and 58%±7%/59%±7% (D2cm), respectively. PARTS was found to be a sensitive metric due to its additive influence of geometry changes on PARTS' sub-metrics. There were no statistical differences (p > 0.05) for stability, except for PARTS (p = 0.04, median difference -0.6%). Statistical differences for robustness when significant were small for most metrics (<2.0% median). Median adaptive re-optimizations were 2. CONCLUSION: We describe a 5-fraction ablative SMART planning approach for PCa that is robust and stable during on-table adaption, due to gradients controlled by a GI PRV technique and the use of rings. These findings are noteworthy given that daily interfraction anatomic GI OAR differences are routine, thus necessitating on-table adaptation. This work supports feasibility towards utilizing a patient-independent, template on-table adaptive approach.

20.
JACC Cardiovasc Interv ; 16(18): 2277-2290, 2023 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-37758382

RESUMO

BACKGROUND: The burden of cardiac death after transcatheter aortic valve replacement (TAVR), particularly from advanced heart failure (HF) and sudden cardiac death (SCD), remains largely unknown. OBJECTIVES: This study sought to evaluate the incidence and predictors of SCD and HF-related death in TAVR recipients treated with newer-generation devices. METHODS: This study included a total of 5,421 consecutive patients who underwent TAVR with newer-generation devices using balloon (75.7%) or self-expandable (24.3%) valves. RESULTS: After a median follow-up of 2 (IQR: 1-3) years, 976 (18.0%) patients had died, 50.8% from cardiovascular causes. Advanced HF and SCD accounted for 11.6% and 7.5% of deaths, respectively. Independent predictors of HF-related death were atrial fibrillation (HR: 2.17; 95% CI: 1.47-3.22; P < 0.001), prior pacemaker (HR: 1.79; 95% CI: 1.10-2.92; P = 0.01), reduced left ventricular ejection fraction (HR: 1.08 per 5% decrease; 95% CI: 1.01-1.14; P = 0.02), transthoracic approach (HR: 2.50; 95% CI: 1.37-4.55; P = 0.003), and new-onset persistent left bundle branch block (HR: 1.85; 95% CI: 1.14-3.02; P = 0.01). Two baseline characteristics (diabetes, HR: 1.81; 95% CI: 1.13-2.89; P = 0.01; and chronic kidney disease, HR: 1.72; 95% CI: 1.02-2.90; P = 0.04) and 3 procedural findings (valve in valve, HR: 2.17; 95% CI: 1.01-4.64; P = 0.04; transarterial nontransfemoral approach, HR: 2.23; 95% CI: 1.23-4.48; P = 0.01; and periprocedural ventricular arrhythmia, HR: 7.19; 95% CI: 2.61-19.76; P < 0.001) were associated with an increased risk of SCD after TAVR. CONCLUSIONS: Advanced HF and SCD accounted for a fifth of deaths after TAVR in contemporary practice. Potentially treatable factors leading to increased risk of HF deaths and SCD were identified, such as arrhythmia/dyssynchrony factors for HF and valve-in-valve TAVR or periprocedural ventricular arrhythmias for SCD.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Função Ventricular Esquerda , Resultado do Tratamento , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...