Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 31(5): 9018-9033, 2023 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-36860004

RESUMO

In this work, we demonstrate the properties of Rhodamine B-doped polymeric cylindrical microlasers to perform either as gain amplification devices through amplified spontaneous emission (ASE) or as optical lasing gain devices. A study based on different %wt concentrations of microcavity families with distinct geometrical features demonstrates the characteristic dependence on either gain amplification phenomena. Principal component analysis (PCA) discriminates the relationship between the main ASE and lasing properties and the geometrical aspects of the cavity families. ASE and optical lasing thresholds were found, respectively, as low as 0.2 µJcm-2 and 0.1 µJcm-2 passing the best-reported microlaser performances in literature for cylindrical cavities, even in comparison with those based on 2D patterns. Moreover, our microlasers showed ultrahigh Q-factor of ∼3 × 106, and for the first time, to the best of our knowledge, a visible emission comb constituted by above a hundred peaks at 40 µJcm-2 with a registered free spectral range (FSR) of 0.25 nm corroborated through the whispery gallery mode (WGM) theory.

2.
Spectrochim Acta A Mol Biomol Spectrosc ; 290: 122250, 2023 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-36566533

RESUMO

Fluorophores with optimized nonlinear optical properties have become prominent as contrast labels in laser scanning microscopy (LSM). The purpose of this work is to report on a novel benzothiadiazole derivative, namely 4,7-bis(5-((9,9-dioctyl-9H-fluoren-2-yl)ethynyl)thiophen-2-yl)benzo[c][1,2,5]thiadiazole (EFBT) and its optical performance when it is loaded into organic nanostructures intended as labels for LSM. Four different nanostructured labels were prepared: i) EFBT-loaded silica nanoparticles (SiNPs); ii) folate-bioconjugated SiNPs (SiNPs-FA); iii) EFBT-loaded PEGylated nanoparticles (NPs-PEG); and iv) EFBT-loaded folate-terminated PEGylated nanoparticles (NPs-PEG-FA). All these nanostructures are reported through a comparative study of their linear and nonlinear optical properties, including their performance as exogenous label agents in the cervical cancer cell line HeLa. This assessment of the performance of a specific fluorophore loaded into different nanostructured matrices (labels), and fairly compared under the same characterization conditions, including the LSM settings, is less common while previous reports had focused in comparing silica and PEGylated nanoparticles but loaded with different fluorophores. The results show that the internal molecular organization into each type of organic nanostructure impacted differently the properties of EFBT, where the silica matrix tend to preserve the optical performance of the fluorophore by preventing intermolecular interactions; in contrast, PEGylated nanoparticles favored molecular interactions and introduced non-radiative decay channels that degrades drastically the optical performance. Nevertheless, the use of functionalized ends entities produced a better cellular label uptake with PEGylated that with silica nanoparticles. In overall, the NPs-PEG-FA label produced the best HeLa imaging.


Assuntos
Nanopartículas , Tiadiazóis , Humanos , Células HeLa , Corantes Fluorescentes/química , Polietilenoglicóis/química , Ácido Fólico/química , Dióxido de Silício , Nanopartículas/química
3.
Appl Opt ; 60(3): 720-726, 2021 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-33690454

RESUMO

Our current work exploits direct laser writing (DLW) and low one-photon absorption (LOPA) in a low-cost three-dimensional optical fabrication system designed to print micrometric polymeric structures. Micropedestals were obtained by focusing a laser beam on a photoresist layer deposited on a silica glass substrate. Subsequent coating with rhodamine 6G dye allows these pedestals to function as microlasers upon optical excitation at 532 nm. Our microlasers, with a diameter of ∼53µm and a height of ∼40µm, exhibit a broad fluorescence peak in the spectral range 540-600 nm, in addition to narrow lasing peaks, exhibiting quality factors Q exceeding 2000 and a lasing threshold of ∼5µJcm-2. The observed free spectral range associated with the lasing peaks of ∼1.3nm is consistent with simulations, which we include in this paper. In addition, we present simulations for the longitudinal shift of the patterning laser spot, which occurs particularly for relatively thick photoresist layers, coupled with a large index contrast at the photoresist top surface. Such a shift could introduce errors in the resulting microfabricated structures if left unaccounted for. We hope that our work will contribute to the development of microlasers for various photonic applications, particularly if dimensions can be reduced, for on-chip optical communications and data processing.

4.
Int J Thermophys ; 31(4): 784-792, 2010 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-20730036

RESUMO

The purpose of this research was to investigate the sensitivity of a system for the detection of circulating melanoma cells based on the thermoelastic properties of melanoma. The method employs photoacoustic (PA) excitation coupled with an optical transducer capable of determining the presence of cells within the circulating system in vitro. The transducer is based on stress wave-induced changes of the optical reflectance of a glass-water interface, probed with a continuous laser beam that is incident at an angle close to the critical angle of total internal reflection. A frequency tripled Nd:YAG laser pumping an optical parametric oscillator was employed to provide 532 nm and 620 nm laser light with a pulse duration of 10 ns. A custom-made flow chamber was used as an excitation and acoustic wave collection device. The targets were a human melanoma cell line HS 936 with an average diameter of about 15 µm. Melanoma cells were suspended in 10 mL of two types of media. The first one was Tyrode's buffer in concentrations ranging from 10 to 50 cells per µL, and the second one included 10(6) healthy white blood cells per mL of Tyrode's buffer. PA pressure waves were detected by an optical stress transducer. Detection trials resulted in a detection threshold of the order of one individual cell, indicating the effectiveness of the proposed mechanism. Results imply the potential to assay simple blood samples, from healthy and metastatic patients, to test the presence of cancerous melanoma providing an unprecedented method for screening metastatic disease.

5.
Lasers Med Sci ; 22(4): 229-36, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17297595

RESUMO

Serum samples were studied using Raman spectroscopy and analyzed through the multivariate statistical methods of principal component analysis (PCA) and linear discriminant analysis (LDA). The blood samples were obtained from 11 patients who were clinically diagnosed with breast cancer and 12 healthy volunteer controls. The PCA allowed us to define the wavelength differences between the spectral bands of the control and patient groups. However, since the differences in the involved molecules were in their tertiary or quaternary structure, it was not possible to determine what molecule caused the observed differences in the spectra. The ratio of the corresponding band intensities were analyzed by calculating the p values and it was found that only seven of these band ratios were significant and corresponded to proteins, phospholipids, and polysaccharides. These specific bands might be helpful during screening for breast cancer using Raman Spectroscopy of serum samples. It is also shown that serum samples from patients with breast cancer and from the control group can be discriminated when the LDA is applied to their Raman spectra.


Assuntos
Neoplasias da Mama/sangue , Análise Espectral Raman , Adulto , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Estudos de Casos e Controles , Feminino , Humanos , Modelos Lineares , Pessoa de Meia-Idade , Análise Multivariada , Projetos Piloto , Análise de Componente Principal
6.
Bioelectromagnetics ; 26(7): 564-70, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16142780

RESUMO

The impedance spectroscopy technique (IST) was used for studying the effect of a 0.5 T magnetic field on the electrical properties of whole human blood. A Solartron SI 1260 spectrometer was used to measure the impedance spectra of magnetic field exposed blood samples compared to non-exposed samples. An equivalent electrical circuit model, consisting in a resistance Rs in series with a parallel circuit formed by a constant phase element (CPE) and another resistance Rp, is proposed to fit the data in both cases. The experiment used 3 ml human blood samples from 160 healthy donors. A Wilcoxon matched pairs statistical test was applied to the data. The data analysis seems to show a statistically significant increase of the values of resistance Rp (Z = 5.06, P < 0.001) and capacitance CT (Z = 3.32, P < 0.001) of the blood exposed to magnetic field, by approximately 10.4% and 1.9%, respectively.


Assuntos
Fenômenos Fisiológicos Sanguíneos/efeitos da radiação , Campos Eletromagnéticos , Magnetismo , Análise Espectral/métodos , Adolescente , Adulto , Capacitância Elétrica , Impedância Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação
7.
Physiol Meas ; 25(5): 1261-70, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15535190

RESUMO

A magnetic pulse generator has been set up in order to study gastric activity. Two coils 1.05 m in diameter, arranged in a Helmholtz configuration, were used. The system generated magnetic field pulses higher than 15 mT, of duration 17.3+/-1.2 ms. Measurements were performed in 11 male volunteers, with average age 29.3+/-6.4 years and body mass index 26.0+/-4.8 kg m(-2). Magnetite (Fe3O4) particles with diameters from 75 to 125 microm were used as magnetic tracers, which were mixed in 250 ml of yogurt in concentrations from 2 to 5 g. Signals were registered by using a high speed 3 axis fluxgate digital magnetometer and processed to determine the relaxation of the magnetic tracers by fitting a first-order exponential function to the data, a mean relaxation constant K = 116+/-40 s(-1) was obtained. Also, an average gastric peristaltic frequency was measured; a value of 3.2+/-0.3 cpm was determined.


Assuntos
Magnetismo , Peristaltismo/fisiologia , Estômago/fisiologia , Adulto , Índice de Massa Corporal , Ingestão de Alimentos , Humanos , Masculino , Iogurte
8.
Neurol Clin Neurophysiol ; 2004: 31, 2004 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-16012604

RESUMO

Twenty measurements of the colon transit time (CTT) were performed by biomagnetic technique in five young women. Subjects were assessed during 12 hours a day for four phases of the menstrual cycle (MC): early follicular (EF), days 1-4 of the MC; late follicular (LF), days 9-14; early luteal (EL), days 15-18; and late luteal (LL), days 23-28 of the MC. Comparison intra and inter-subjects were made. The results of a t test for dependent samples, demonstrate that women with regular MC had higher CTT on LF (3.29 +/- 1.40 m/hr) than on LL phases of the MC (1.28 +/- 0.4 m/hr) t = 3.22, p = 0.04. Also we found differences from EL to LL phases of the MC (4.49 +/- 1.72 m/hr vs. 1.29 +/- 0.35 m/hr, t = 3.05, p = 0.05). However, in a patient with polycystic ovary syndrome (PCOS), we found a CTT of 3.1 m/hr on day 3; 2 m/hr on day 15; and 0.8 m/hr on day 30 of the MC. The time of the magnetic marker displacement was higher on days 3 of the MC, if we compared these values with those from women with regular MC (1.8 +/- 0.67 m/hr). We demonstrate that biomagnetic technique is a powerful method to assess changes in CTT presented in female subjects during the MC. Furthermore, the results found for the CTT in different phases of the MC of the females subjects, are in agreement with those reported by using other techniques.


Assuntos
Colo/fisiologia , Campos Eletromagnéticos , Trânsito Gastrointestinal/fisiologia , Ciclo Menstrual/fisiologia , Adulto , Fenômenos Eletromagnéticos , Feminino , Humanos
9.
Physiol Meas ; 23(3): 521-32, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12214760

RESUMO

A photoacoustic technique is used for studying topically applied substance absorption in human skin. The proposed method utilizes a double-chamber PA cell. The absorption determination was obtained through the measurement of the thermal effusivity of the binary system substance-skin. The theoretical model assumes that the effective thermal effusivity of the binary system corresponds to that of a two-phase system. Experimental applications of the method employed different substances of topical application in different parts of the body of a volunteer. The method is demonstrated to be an easily used non-invasive technique for dermatology research. The relative concentrations as a function of time of substances such as ketoconazol and sunscreen were determined by fitting a sigmoidal function to the data, while an exponential function corresponds to the best fit for the set of data for nitrofurazona, vaseline and vaporub. The time constants associated with the rates of absorption, were found to vary in the range between 10 and 58 min, depending on the substance and the part of the body.


Assuntos
Anti-Infecciosos Locais/farmacocinética , Modelos Biológicos , Nitrofurazona/farmacocinética , Pele/metabolismo , Acústica , Administração Tópica , Anti-Infecciosos Locais/administração & dosagem , Combinação de Medicamentos , Emolientes/administração & dosagem , Emolientes/farmacocinética , Antebraço , Humanos , Nitrofurazona/administração & dosagem , Vaselina/administração & dosagem , Vaselina/farmacocinética , Fotometria , Extratos Vegetais/administração & dosagem , Extratos Vegetais/farmacocinética , Temperatura Cutânea , Terpenos/administração & dosagem , Terpenos/farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...