Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Surg Technol Int ; 30: 19-24, 2017 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-28693047

RESUMO

OBJECTIVE: To evaluate tissue effect of J-Plasma® (Bovie Medical Corporation, Clearwater, Florida) in porcine liver, kidney, muscle, ovarian, and uterine tissue blocks. DESIGN: Prospective study utilizing porcine tissue blocks to evaluate the thermal spread of J-Plasma® device on liver, kidney, muscle, ovarian, and uterine tissue at various power settings, gas flow, and exposure times. MATERIALS AND METHODS: J-Plasma® helium was used in porcine liver, kidney, and muscle tissue at 20%, 50%, and 100% power, and 1 L/min, 3 L/min, and 5 L/min gas flow at one, five, and 10-second intervals. J-Plasma® was then used in ovarian and uterine tissue at maximum power and gas flow settings in intervals of one, five, 10, and 30 seconds. Histologic evaluation of each tissue was then performed to measure thermal spread. RESULTS: Regardless of tissue type, increased power setting, gas flow rate, and exposure time correlated with greater depth of thermal spread in liver, kidney, and muscle tissue. J-Plasma® did not exceed 2 mm thermal spread on liver, kidney, muscle, ovarian, and uterine tissue, even at a maximum setting of 100% power and 5 L/min gas flow after five seconds. Prolonged exposure to J-Plasma® of up to 30 seconds resulted in increased length and width of thermal spread of up to 12 mm, but did not result in significantly increased depth at 2.84 mm. CONCLUSIONS: The J-Plasma® helium device has minimal lateral and depth of thermal spread in a variety of tissue types and can likely be used for a multitude of gynecologic surgical procedures. However, further studies are needed to demonstrate device safety in a clinical setting.


Assuntos
Eletrocirurgia/métodos , Temperatura Alta , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Modelos Biológicos , Gases em Plasma/química , Animais , Eletrocirurgia/efeitos adversos , Eletrocirurgia/instrumentação , Desenho de Equipamento , Feminino , Hélio/química , Rim/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Ovário/patologia , Ovário/cirurgia , Estudos Prospectivos , Suínos , Útero/patologia , Útero/cirurgia
2.
Surg Technol Int ; 30: 191-196, 2017 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-28277596

RESUMO

PURPOSE: The purpose of this paper is to introduce a novel trans-illuminating culdotomy and uterine manipulator device. MATERIALS AND METHODS: The study was a prospective, non-randomized, non-blinded observational clinical study involving 50 female patients undergoing total laparoscopic hysterectomy (TLH) or laparoscopic supracervical hysterectomy (LSH) for benign indications. The surgeries were performed from March through May 2012 at two institutions. The primary study objectives were to demonstrate the safety and adequate clinical performance of the uterine manipulator device and to illustrate its potential widespread future use in minimally invasive gynecologic procedures. RESULTS: Average patient age was 45.1 years and, of the 50 patients, 33 had undergone previous intra-abdominal surgery. There were no reports of adverse events, difficulty with placement of the instrument, multiple attempts at placement, or difficulty with uterine manipulation. There was only one device-related uterine perforation, and pneumoperitoneum was maintained in all cases during culdotomy. Vaginal tissue left on subjects was less than 5mm. Overall, there were no ureteral injuries, there were two reported incidental cystotomies, and average blood loss was 99.0cc. Postoperative courses were normal for all patients, with only two reported postoperative complications: a possible vaginal cuff abscess and a 2cm vaginal mucosal cuff separation. CONCLUSIONS: The McCarus-Volker ForniSee® (LSI Solutions, Inc., Victor, New York) is a novel trans-illuminating culdotomy device and uterine manipulator that is safe, efficient, functional, and easy to use. Trans-illumination additionally delineates and enhances identification of critical anatomic planes, such as the vesicovaginal junction and cervicovaginal junction.


Assuntos
Colpotomia/instrumentação , Histerectomia , Laparoscopia/instrumentação , Procedimentos Cirúrgicos Robóticos/instrumentação , Adulto , Desenho de Equipamento , Feminino , Humanos , Histerectomia/efeitos adversos , Histerectomia/instrumentação , Histerectomia/métodos , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Doenças Uterinas/cirurgia , Útero/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...