Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Talanta ; 239: 123072, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34864535

RESUMO

Amitriptyline and its metabolite, Nortriptyline are commonly used tricyclic antidepressant (TCA) drugs that are electrochemically active. In this work, the performance characteristics of a plasticized PVC membrane-coated glassy carbon (GC) electrode are described for the voltammetric quantification of Amitriptyline and Nortriptyline in whole blood. The highly lipophilic Amitriptyline and Nortriptyline preferentially partition into the plasticized PVC membrane where the free drug is oxidized on the GC electrode. The concentrations of the drugs in the membrane are orders of magnitude larger than in the sample solution, resulting in superb limit of detection (LOD) of the membrane-coated voltammetric sensor: 3 nmol/L for Amitriptyline and 20 nmol/L for Nortriptyline. Conversely, hydrophilic components of the sample solution, e.g., proteins, the protein-bound fraction of the drugs, and electrochemically active small molecules are blocked from entering the membrane, which provides exceptional selectivity for the membrane-coated sensor and feasibility for the measurements of Amitriptyline in whole blood. In this work, the concentrations of Amitriptyline and Nortriptyline were determined in whole blood using the sensor and the results of our analysis were compared to the results of the standard HPLC-MS method. Based on our experience, the one-step voltammetric methods with the membrane-coated sensor may become a real alternative to the significantly more complex HPLC-MS analysis.


Assuntos
Amitriptilina , Nortriptilina , Antidepressivos Tricíclicos , Cromatografia Líquida de Alta Pressão , Limite de Detecção
2.
Anal Chim Acta ; 1171: 338642, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34112432

RESUMO

Thin plasticized PVC membrane-coated glassy carbon working electrodes have been used for the voltammetric measurement of highly lipophilic, electroactive drugs. Compared to conventional working electrodes, these membrane-coated electrodes exhibit remarkable detection limit and selectivity and are less prone to electrode fouling. The unique performance characteristics of these sensors are related to the large partition coefficient of the analyte in the membrane coating where it is oxidized in a non-aqueous membrane phase. To analyze the influence of the key parameters of the response of membrane-coated sensors, we derived theoretical expressions on the voltammetric response of the sensors. In our analysis we considered 1) the partition coefficient (Pmw) of the analyte between the aqueous sample and the organic membrane, 2) the membrane volume to sample volume ratio (Vm/Vw), and 3) the binding constant of constituents in the sample that bind the analyte (K). The results of our theoretical analysis have been tested through voltammetric measurement of highly lipophilic analytes with logPow values (logarithm of the partition coefficient between octanol and water) ranging between 0.3 and 7.5. By understanding of the influence of the sensor design parameters on the overall sensor response, these parameters can be tuned for optimized response slope, detection limit, etc., for solving specific analytical tasks.

3.
Langmuir ; 37(1): 499-508, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-33372781

RESUMO

To assess the feasibility of utilizing reagent-loaded, porous polymeric nanocapsules (NCs) for chemical and biochemical sensor design, the surfaces of the NCs were decorated with 3,4-ethylenedioxythiophene (EDOT) moieties. The pores in the capsule wall allow unhindered bidirectional diffusion of molecules smaller than the programmed pore sizes, while larger molecules are either entrapped inside or blocked from entering the interior of the nanocapsules. Here, we investigate two electrochemical deposition methods to covalently attach acrylate-based porous nanocapsules with 3,4-ethylenedioxythiophene moieties on the nanocapsule surface, i.e., EDOT-decorated NCs to the surface of an existing PEDOT film: (1) galvanostatic or bilayer deposition with supporting EDOT in the deposition solution and (2) potentiostatic deposition without supporting EDOT in the deposition solution. The distribution of the covalently attached NCs in the PEDOT films was studied by variable angle FTIR-ATR and XPS depth profiling. The galvanostatic deposition of EDOT-decorated NCs over an existing PEDOT (tetrakis(pentafluorophenyl)borate) [PEDOT(TPFPhB)] film resulted in a bilayer structure, with an interface between the NC-free and NC-loaded layers, that could be traced with variable angle FTIR-ATR measurements. In contrast, the FTIR-ATR and XPS analyses of the films deposited potentiostatically from a solution without EDOT and containing only the EDOT-decorated NCs showed small amounts of NCs in the entire cross section of the films.

4.
Membranes (Basel) ; 10(9)2020 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-32867276

RESUMO

In the last 50 years, plasticized polyvinyl chloride (PVC) membranes have gained unique importance in chemical sensor development. Originally, these membranes separated two solutions in conventional ion-selective electrodes. Later, the same membranes were applied over a variety of supporting electrodes and used in both potentiometric and voltammetric measurements of ions and electrically charged molecules. The focus of this paper is to demonstrate the utility of the plasticized PVC membrane modified working electrode for the voltammetric measurement of highly lipophilic molecules. The plasticized PVC membrane prevents electrode fouling, extends the detection limit of the voltammetric methods to sub-micromolar concentrations, and minimizes interference by electrochemically active hydrophilic analytes.

5.
ACS Sens ; 5(7): 2146-2154, 2020 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-32560587

RESUMO

The theoretical models for ISEs almost exclusively assume thermodynamic equilibrium at the membrane/solution-phase boundary. In this report, we present a new, congruent model which combines first-order reaction kinetics of ion-exchange at the phase boundary and diffusional mass transport in the adjoining phases in the continuity equation. The influence of the rate constant in the new kinetic model has significant impact on the predicted transients corresponding to instantaneous change in the sample solution composition. The simulated transients generated with the new model coincide with the transients recorded in common potentiometric experiments, e.g., with transients recorded upon step change in the primary or interfering ion concentrations. The simulated transients also align well with previously published transients representing special cases of potentiometry (e.g., super-Nernstian response, non-Nernstian responses in the presence of highly interfering ions). The implementation of the kinetic model for simulating the transients in the water layer test also resulted in a better agreement with the experiments compared to the previous models.


Assuntos
Eletrodos Seletivos de Íons , Membranas Artificiais , Íons , Cinética , Potenciometria
6.
ACS Sens ; 4(3): 549-561, 2019 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-30762347

RESUMO

In this paper, we raise questions that researchers have to ask if they intend to replace a conventional reference electrode with an ionic liquid-based reference electrode and try to answer these questions based on our experiences and literature data. Among these questions, the most important is which ionic liquid should be used. However, beyond the chemical composition of the ionic liquid, to realize all the potential benefits of ionic-liquid based reference electrodes, there are additional, equally important considerations. Through examples we will show the importance of the (i) purity of the ionic liquid and the consequences of deviations from its stoichiometric salt composition, (ii) form of implementation of the ionic liquid-based reference electrode membrane (free-flowing salt bridge, or ionic liquid embedded in a membrane), (iii) membrane/gelling agent material and its composition, and (iv) experimental conditions (steady state or flowing conditions) under which it will be used. Finally, we recommend methods to test the performance criteria of the ionic liquid-based reference electrodes.


Assuntos
Eletroquímica/instrumentação , Líquidos Iônicos/química , Eletrodos , Interações Hidrofóbicas e Hidrofílicas , Tensoativos/química
7.
Anal Chem ; 89(16): 8468-8475, 2017 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-28691799

RESUMO

The aim of this study was to find a conducting polymer-based solid contact (SC) for ion-selective electrodes (ISEs) that could become the ultimate, generally applicable SC, which in combination with all kinds of ion-selective membranes (ISMs) would match the performance characteristics of conventional ISEs. We present data collected with electrodes utilizing PEDOT-C14, a highly hydrophobic derivative of poly(3,4-ethylenedioxythiophene), PEDOT, as SC and compare its performance characteristics with PEDOT-based SC ISEs. PEDOT-C14 has not been used in SC ISEs previously. The PEDOT-C14-based solid contact (SC) ion-selective electrodes (ISEs) (H+, K+, and Na+) have outstanding performance characteristics (theoretical response slope, short equilibration time, excellent potential stability, etc.). Most importantly, PEDOT-C14-based SC pH sensors have no CO2 interference, an essential pH sensors property when aimed for whole-blood analysis. The superhydrophobic properties (water contact angle: 136 ± 5°) of the PEDOT-C14 SC prevent the detachment of the ion-selective membrane (ISM) from its SC and the accumulation of an aqueous film between the ISM and the SC. The accumulation of an aqueous film between the ISM and its SC has a detrimental effect on the sensor performance. Although there is a test for the presence of an undesirable water layer, if the conditions for this test are not selected properly, it does not provide an unambiguous answer. On the other hand, recording the potential drifts of SC electrodes with pH-sensitive membranes in samples with different CO2 levels can effectively prove the presence or absence of a water layer in a short time period.

8.
Anal Chem ; 89(6): 3508-3516, 2017 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-28194968

RESUMO

To understand the rate determining processes during the equilibration of poly(3,4-ethylenedioxythiophene):polystyrenesulfonate-based (PEDOT(PSS)-based) solid contact (SC) ion-selective electrodes (ISEs), the surfaces of Pt, Au, and GC electrodes were coated with 0.1, 1.0, 2.0, and 4.0 µm thick galvanostatically deposited PEDOT(PSS) films. Next, potential vs time transients were recorded with these electrodes, with and without an additional potassium ion-selective membrane (ISM) coating, following their first contact with 0.1 M KCl solutions. The transients were significantly different when the multilayered sensor structures were assembled on Au or GC compared to Pt. The differences in the rate of equilibration were interpreted as a consequence of differences in the hydrophilicity of PEDOT(PSS) in contact with the substrate electrode surfaces based on X-ray photoelectron spectroscopy (XPS) and synchrotron radiation-XPS (SR-XPS) analysis of 10-100 nm thick PEDOT(PSS) films. The influence of the layer thickness of the electrochemically deposited PEDOT(PSS)-films on the hydrophilicity of these films has been documented by contact angle measurements over PEDOT(PSS)-coated Au, GC, and Pt electrode surfaces. This study demonstrates that it is possible to minimize the equilibration (conditioning) time of SC ISEs with aqueous solutions before usage by optimizing the thickness of the SC layer with a controlled ISM thickness. PEDOT(PSS)-coated Au and GC electrodes exhibit a significant negative potential drift during their equilibration in an aqueous solution. By coating the PEDOT(PSS) surface with an ISM, the negative potential drift is compensated by a positive potential drift related to the hydration of the ISM and activity changes at the PEDOT(PSS)|ISM interface. The potential drifts related to activity changes in the ISM have been determined by a novel adaptation of the "sandwich membrane" method.

9.
Anal Chem ; 87(13): 6654-9, 2015 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-26005770

RESUMO

Papers published on ion-selective electrodes (ISEs) generally report on the performance characteristics of these devices after long, extensive conditioning. Conditioning refers to the equilibration of the ion-selective electrode in an aqueous solution before the measurement of the sample. The requirement for long and repeated conditioning is a significant burden in a variety of applications, for example, single-use sensors aimed for in vivo or field applications and solid contact (SC) ISEs, which were developed to provide simple, mass-produced sensors that have the potential to be implemented without calibration and extensive conditioning. In this study we recorded the potential of SC K(+), Na(+), and H(+) ISEs as a function of time following their first contact with an aqueous electrolyte solution and used these transients to determine their equilibration times. The SC electrodes were built on Au, Pt, and glassy carbon (GC) substrates using galvanostatically deposited conductive polymer (PEDOT(PSS(-)), poly(3,4-ethylenedioxythiophene) polystyrenesulfonate) as ion-to-electron transducer (solid internal contact) between the ion-selective membrane and the substrate. The SC electrodes built on GC and Au had significantly shorter equilibration times (between 5 and 13 min) than the SC electrodes built on Pt substrates (>60 min). Such significant differences in the equilibration times of SC ISEs built on different substrate electrodes are reported here for the first time. These unexpected findings suggest that the interface between the conductive polymer and the electron-conducting substrate (EC) has significant influence on the long-term dynamic behavior of SC ISEs.


Assuntos
Eletrodos Seletivos de Íons
10.
Anal Chim Acta ; 791: 1-12, 2013 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-23890601

RESUMO

In potentiometry, high selectivity of the ion-selective membranes must be assured in order to reliably measure various analytes in clinical, industrial and environmental samples. Due to the toxic nature of lead(II) it is important to monitor Pb(2+) distribution in natural waters. This may be achieved by implementation of ion-selective electrodes (ISEs) with high selectivity towards lead(II) and low detection limit. A great number of Pb(2+)-ionophores were synthesized and studied. In this work lead(II)-selective ionophores, starting from late 90s, are gathered and discussed. This work gives a comprehensive description and discussion on the novel and available lead(II)-selective ionophores for ISEs.

11.
Anal Chem ; 85(3): 1555-61, 2013 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-23281967

RESUMO

Thioamide derivatives of p-tert-butylcalix[4]arene were used as ionophores in the development of solid-contact ion-selective electrodes based on conducting polymer poly(3,4-ethylenedioxythiophene)/polystyrene sulfonate (PEDOT/PSS) which was synthesized by electrodeposition on the glassy carbon electrodes. The typical ion-selective membranes with optionally two different plasticizers [bis(2-ethylhexyl)sebacate (DOS) and 2-nitrophenyl octyl ether (NPOE)] were investigated. The potentiometric selectivity coefficients were determined by separate solution method (SSM) for Pb(2+) over Cu(2+), Cd(2+), Ca(2+), Na(+), and K(+). High selectivity toward Pb(2+) was obtained. By applying two conditioning protocols, a low detection limit log(a(DL)) ≈ -9 was achieved. The fabricated ion-selective electrodes were used to determine Pb(2+) concentration in environmental samples. The obtained results were compared to analysis done by inductively coupled plasma mass spectrometry (ICPMS).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...