Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 92(6): 1147-1152, 2018 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-30019847

RESUMO

OBJECTIVE: To evaluate the safety and efficacy of a new technique for accurate ostial/non-ostial coronary stenting in percutaneous coronary intervention (PCI). BACKGROUND: Accurate stent localization is a key factor impacting the postoperative success of patients undergoing PCI. However, the accurate localization of some lesions, especially ostial lesions, is very difficult to achieve, because they are often complicated by bobbing or to-and-fro movement of the stent during cardiac contractions. METHODS: We report a novel technique of precise ostial/non-ostial stenting based on the buddy balloon anchor stent (BBAS) technique. Between May 2014 and July 2017, 47 patients with significant ostial/non-ostial coronary stenosis that required accurate stenting were included in this study. Of them, 23 patients were treated using the conventional method and the remaining 24 patients were treated using (BBAS) technique. Evaluation was then performed using intravascular ultrasound (IVUS) in the procedural, or coronary computed tomography angiography (CCTA) in the follow up. RESULTS: Using the BBAS technique, the procedural success was achieved in all 24 (100%) cases. IVUS was performed in seven patients (29.17%) and no procedural complications occurred. All six failed cases that occurred among patients with right coronary artery and left anterior descending artery ostial stenosis treated using the conventional method, the lesions were subsequently successfully re-stented using the BBAS technique. After a follow-up of 3-36 months, CCTA was performed in 11 patients (45.83%), all the stents were in the accurate position. There were no major cardiovascular events of death, myocardial infarction, or target lesion revascularization. CONCLUSION: BBAS is a simple, highly successful and safe technique for accurate stenting of difficult ostial/nonostial coronary stenosis lesions.


Assuntos
Angioplastia Coronária com Balão/métodos , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Stents , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...