STUDY OBJECTIVES: to develop taking into account the specifity of exposure conditions a new algorithm for interventional cardiologists who use the X-ray protective clothes. MATERIALS AND METHODS: modelling of the typical conditions of radiation exposure of interventional cardiologist wearing protective clothes during the interventions, providing Monte-Carlo computations of organ doses and dosimeters readouts. RESULTS: partial dose values for all possible radiation conditions and relative frequency weight coefficients for each condition were obtained by Monte-Carlo method. CONCLUSIONS: flexible and adaptive methodology for algorithm developing was proposed, a more specific algorithm was obtained for typical radiation conditions occuring under the interventional cardiology procedures. This algorithm well corresponded to experimental measurements demonstrating at that less conservatism comparing to other known algorithms.


Assuntos
Cardiologia , Exposição Ocupacional , Doses de Radiação , Radiologia Intervencionista , Radiometria/métodos , Raios X/efeitos adversos , Algoritmos , Simulação por Computador , Humanos , Método de Monte Carlo , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Roupa de Proteção , Proteção Radiológica/instrumentação , Proteção Radiológica/métodos