Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
J Arthroplasty ; 39(5): 1341-1347, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38043744

RESUMO

BACKGROUND: Femoral nerve (FN) injury is noted as a serious neurological complication following total hip arthroplasty performed via a direct anterior approach (DAA). Therefore, we aimed to clarify the anatomical course of the FN around the acetabular rim and in relation to retractor placement during DAA. METHODS: According to standard protocol, a DAA for total hip arthroplasty was performed on 69 hemipelves from formalin-preserved full-body donors. The surgery was halted after retractor placement at the anterior part of the acetabulum. Then dissection was performed to expose the FN and the iliopsoas muscle. Various measurements were taken using a reference line from the anterior superior iliac spine to the acetabulum's center. A total of 6 measurement points, one every 30° from 0° to 150° along the reference line were used to determine the association between the FN and the retractor tip (RT) and the anterior acetabular rim. RESULTS: The mean distance from the RT to the FN was 22.5 millimeters (mm). The distance from the FN to the anterior acetabular rim decreased from 0 to 90°, where it was 18.8 mm, before increasing again to 27.3 mm at 150°. CONCLUSIONS: In our cadaveric study, the FN was within 11 to 36 mm of the RT. Second, we found the FN to be closest to the anterior acetabular rim at 90° and 120°. Accordingly, special care should be taken during retractor placement, and if possible, placement at 90° and 120° avoided.

2.
J Arthroplasty ; 39(4): 1088-1092, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37918488

RESUMO

BACKGROUND: Iatrogenic vascular injury during total hip arthroplasty (THA) is rare, reported at rates of 0.05 to 0.3%, but a potentially limb-threatening and life-threatening complication. We aimed to describe safe and danger zones for the superior gluteal vessel bundle (SGV bundle) with reference to different THA approaches. METHODS: There were 27 formalin-fixed cadavers with 49 hemipelves dissected. The course and distribution of the SGV bundle were investigated with the help of anatomical landmarks like the greater trochanter, the iliac tubercle (IT), and the ischial tuberosity. RESULTS: We found and exposed the SGV bundle in all 49 specimens with no sex-specific differences. No SGV bundle was encountered up to 28 mm from the greater trochanter and up to 16 mm below the IT. The zone with the highest probability of finding the vessels was 25 to 65 mm below the IT in 39 (80%) cases - defining a danger zone (in relation to the skin incision) in the proximal fourth for the direct anterior approach, in the proximal half for the antero-lateral approach, in the proximal fifth for the direct lateral approach, and almost no danger zone for the posterior approach. CONCLUSIONS: Special care in proximal instrument placement should be taken during THA. When extending one of the surgical approaches, manipulations in the proximal, cranial surgical window should be performed with the utmost care to avoid SGV bundle injury.


Assuntos
Artroplastia de Quadril , Lesões do Sistema Vascular , Humanos , Nádegas/cirurgia , Cadáver , Fêmur , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/prevenção & controle
3.
Anat Sci Educ ; 16(5): 814-829, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37183973

RESUMO

Hands-on courses utilizing preserved human tissues for educational training offer an important pathway to acquire basic anatomical knowledge. Owing to the reevaluation of formaldehyde limits by the European Commission, a joint approach was chosen by the German-speaking anatomies in Europe (Germany, Austria, Switzerland) to find commonalities among embalming protocols and infrastructure. A survey comprising 537 items was circulated to all anatomies in German-speaking Europe. Clusters were established for "ethanol"-, formaldehyde-based ("FA"), and "other" embalming procedures, depending on the chemicals considered the most relevant for each protocol. The logistical framework, volumes of chemicals, and infrastructure were found to be highly diverse between the groups and protocols. Formaldehyde quantities deployed per annum were three-fold higher in the "FA" (223 L/a) compared to the "ethanol" (71.0 L/a) group, but not for "other" (97.8 L/a), though the volumes injected per body were similar. "FA" was strongly related to table-borne air ventilation and total fixative volumes ≤1000 L. "Ethanol" was strongly related to total fixative volumes >1000 L, ceiling- and floor-borne air ventilation, and explosion-proof facilities. Air ventilation was found to be installed symmetrically in the mortuary and dissection facilities. Certain predictors exist for the interplay between the embalming used in a given infrastructure and technical measures. The here-established cluster analysis may serve as decision supportive tool when considering altering embalming protocols or establishing joint protocols between institutions, following a best practice approach to cater toward best-suited tissue characteristics for educational purposes, while simultaneously addressing future demands on exposure limits.


Assuntos
Anatomia , Humanos , Fixadores , Anatomia/educação , Embalsamamento/métodos , Cadáver , Formaldeído/química , Etanol
4.
Diagnostics (Basel) ; 13(7)2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-37046438

RESUMO

Ionizing radiation is necessary for diagnostic imaging and deciding the right radiation dose is extremely critical to obtain a decent quality image. However, increasing the dosage to improve the image quality has risks due to the potential harm from ionizing radiation. Thus, finding the optimal as low as diagnostically acceptable (ALADA) dosage is an open research problem that has yet to be tackled using artificial intelligence (AI) methods. This paper proposes a new multi-balancing 3D convolutional neural network methodology to build 3D multidetector computed tomography (MDCT) datasets and develop a 3D classifier model that can work properly with 3D CT scan images and balance itself over the heavy unbalanced multi-classes. The proposed models were exhaustively investigated through eighteen empirical experiments and three re-runs for clinical expert examination. As a result, it was possible to confirm that the proposed models improved the performance by an accuracy of 5% to 10% when compared to the baseline method. Furthermore, the resulting models were found to be consistent, and thus possibly applicable to different MDCT examinations and reconstruction techniques. The outcome of this paper can help radiologists to predict the suitability of CT dosages across different CT hardware devices and reconstruction algorithms. Moreover, the developed model is suitable for clinical application where the right dose needs to be predicted from numerous MDCT examinations using a certain MDCT device and reconstruction technique.

5.
Semin Musculoskelet Radiol ; 27(2): 129-135, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37011614

RESUMO

Profound knowledge of nerve variations is essential for clinical practice. It is crucial for interpreting the large variability of a patient's clinical presentation and the different mechanisms of nerve injury. Awareness of nerve variations facilitates surgical safety and efficacy. Clinically significant anatomical variations can be classified into two main groups: variability in the course of the nerve and variability of structures surrounding the nerve. In this review article we focus on the most common nerve variants of the upper extremity and their clinical relevance.


Assuntos
Nervos Periféricos , Extremidade Superior , Humanos , Extremidade Superior/diagnóstico por imagem , Extremidade Superior/cirurgia , Extremidade Superior/inervação , Nervos Periféricos/diagnóstico por imagem , Nervos Periféricos/cirurgia , Variação Anatômica
6.
Dentomaxillofac Radiol ; 52(3): 20220387, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36688730

RESUMO

OBJECTIVES: As-low-as-diagnostically-acceptable (ALADA) doses are substantially lower than current diagnostic reference levels. To improve dose management, a reference quality approach was tested in which phantom quality metrics of a clinical ALADA dose reference protocol were used to benchmark potential ALADA dose protocols for various scanner models. METHODS: Spatial resolution, contrast resolution, contrast-to-noise ratio (CNR) and subjective noise and sharpness were evaluated for a clinical ALADA dose reference protocol at 80 kV and 40 mA (CTDIvol 2.66 mGy) and compared with test protocols of two CT scanners at 100 kV and 35 mA (3.08-3.44 mGy), 80 kV and 54-61 mA (2.65 mGy), 80 kV and 40 mA (1.73-1.92 mGy), and 80 kV and 21-23 mA (1.00-1.03 mGy) using different kernels, filtered backprojection and iterative reconstructions. The test protocols with the lowest dose showing quality metrics non-inferior to the reference protocol were verified in a cadaver study by determining the diagnostic accuracy of detection of maxillofacial fractures and CNR of the optical nerve and rectus inferior muscle. RESULTS: 36 different image series were analysed in the phantom study. Based on the phantom quality metrics, potential ALADA dose protocols at 1.73-1.92 mGy were selected. Compared with the reference images, the selected protocols showed non-inferiority in the detection and classification of maxillofacial fractures and non-inferior CNR of orbital soft tissues in the cadaver study. CONCLUSIONS: Reference quality metrics from clinical ALADA dose protocols may be used to guide selection of potential ALADA dose protocols of different CT scanners.


Assuntos
Traumatismos Maxilofaciais , Tomografia Computadorizada por Raios X , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Cadáver , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
7.
J Anat ; 240(2): 376-384, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34697796

RESUMO

The functions of the subclavius muscle (SM) are described as stabilization of the sternoclavicular joint (SCJ) and resisting elevation of the lateral end of the clavicle. During systematic cadaveric dissections, we observed additional fibrous structures, previously described as variants of the anatomy, extending from the SM and inserting into the coracoid process (CP). Due to the high incidence of these structures in our dissections, we hypothesized that the attachment at the CP is more common than appreciated and that, as a corollary, the function of the SM was (or has been) more complex than simply depressing the clavicle and generating stability at the SCJ. For our investigation, fifty-two upper extremities of 26 human cadavers were dissected. The SM was demonstrated from costal to clavicular attachment. We documented additional fibrous structures apparently derived from the SM inserting into the CP. Measurements of the length of the SM, the length of its attachment, and the length of the clavicle were taken in situ, with the specimens supine and the upper extremity in the anatomical position. Variations in the anatomy of the SM and its coracoidal attachment were recorded, and potential correlations were investigated. For documentation purposes photographs and video sequences of passive motion of the shoulder girdle of the specimens were taken. In 49 of the 52 specimens we found additional fibrous structures passing from the SM to the CP. We differentiated three types: (1) a strong cord-like structure; (2) a small or thin cord-like structure or structures; and (3) a planar twisted sheet-like structure. The SM and its extension to the CP appears to contribute to a 'functional scapular suspension system' together with the other muscles enveloped by the clavipectoral fascia (pectoralis minor, coracobrachialis and the short head of the biceps brachii). This system assists in the control of the position of the scapula in relation to the thorax, particularly in elevated positions of the upper extremity. We speculate that the differentiation of the fibrous structure depends on the functional demands of the individual. Level of Evidence: Basic science study.


Assuntos
Músculos Peitorais , Ombro , Cadáver , Clavícula/fisiologia , Processo Coracoide/anatomia & histologia , Humanos , Escápula/anatomia & histologia
8.
Int J Comput Assist Radiol Surg ; 17(2): 261-270, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34792744

RESUMO

PURPOSE: An auditory brainstem implant (ABI) represents an alternative for patients with profound hearing loss who are constrained from receiving a cochlear implant. The positioning of the ABI electrode influences the patient's auditory capacity and, therefore, quality of life and is challenging even with available intraoperative electrophysiological monitoring. This work aims to provide and assess the feasibility of visual-spatial assistance for ABI positioning. METHODS: The pose of the forceps instrument that grasps the electrode was electromagnetically navigated and interactively projected in the eyepieces of a surgical microscope with respect to a target point. Intraoperative navigation was established with an experimental technique for automated nasopharyngeal patient registration. Two ABI procedures were completed in a human specimen head. RESULTS: An intraoperative usability study demonstrated lower localization error when using the proposed visual display versus standard cross-sectional views. The postoperative evaluations of the preclinical study showed that the center of the electrode was misplaced to the planned position by 1.58 mm and 3.16 mm for the left and the right ear procedure, respectively. CONCLUSION: The results indicate the potential to enhance intraoperative feedback during ABI positioning with the presented system. Further improvements consider estimating the pose of the electrode itself to allow for better orientation during placement.


Assuntos
Implante Auditivo de Tronco Encefálico , Estudos Transversais , Estudos de Viabilidade , Humanos , Qualidade de Vida , Resultado do Tratamento
9.
Diagnostics (Basel) ; 11(10)2021 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-34679601

RESUMO

OBJECTIVE: Repeated computed tomography (CT) is essential for diagnosis, surgical planning and follow-up in patients with middle and inner ear pathology. Dose reduction to "as low as diagnostically acceptable" (ALADA) is preferable but challenging. We aimed to compare the diagnostic quality of images of subtle temporal bone structures produced with low doses (LD) and reference protocols (RP). METHODS: Two formalin-fixed human cadaver heads were scanned using a 64-slice CT scanner and cone-beam CT (CBCT). The protocols were: RP (120 kV, 250 mA, CTDIvol 83.72 mGy), LD1 (100 kV, 80 mA, CTDIvol 26.79 mGy), LD2 (100 kV, 35 mA, CTDIvol 7.66 mGy), LD3 (80 kV, 40 mA, CTDIvol 4.82 mGy), and CBCT standard protocol. Temporal bone structures were assessed using a 5-point scale. RESULTS: A median score of ≥2 was achieved with protocols such as the tendons of m. tensor tympani (RP/LD1/LD2/CBCT) and m. stapedius (CBCT), the incudostapedial joint (RP/LD1/CBCT), the incudomalleolar joint (RP/LD1/LD2/CBCT), the stapes feet (RP/LD1/CBCT), the stapes head (RP/LD1/LD2/CBCT), the tympanic membrane (RP/LD1/LD2/CBCT), the lamina spiralis ossea (none), the chorda tympani (RP/LD1/CBCT), and the modiolus (RP/LD1/LD2/CBCT). Adaptive statistical iterative reconstructions did not show advantages over the filtered back projection. CONCLUSIONS: LD protocols using a CTDIvol of 7.66 mGy may be sufficient for the identification of temporal bone structures.

10.
Clin Anat ; 34(7): 1059-1067, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33580897

RESUMO

INTRODUCTION: One of the transitional zones of the human body is situated in the cervix uteri. The developmental differentiation of epithelial and stromal characteristics in such a region is of high clinical interest. However, few studies have focused on the development of this region, and information in anatomical and clinical textbooks is limited. We therefore examined the development of the human vaginal fornix and the cervix uteri during prenatal development. MATERIALS AND METHODS: We examined 29 female embryos and fetuses between 20 and 34 weeks and two newborns using histology and immunohistochemistry. RESULTS: The characteristic shape of the portiocervicis and the vaginal fornix first became visible in mid-term fetuses because of the different muscular coats and of an uncategorized Müllerian-derived epithelium, which was rapidly replaced by a multilayered squamous epithelium. Only thereafter, in older fetuses, were there organogenetic differentiation of the epithelia and the underlying stroma of the cervical canal. UGS-derived p63/CK17-positive cells could be identified as precursor cells for the squamous epithelium, and Müllerian-derived CK7-positive cells for the columnar-type epithelium. Both cell types and different stromal zones were already present in a prenatal transformation zone. Initial functional differentiation could be observed in perinatal stages. CONCLUSIONS: Our results on prenatal human development strongly support the view that two different cell lineages meet at the transitional zone of the cervix uteri and that these lineages depend on alternative signals from the underlying stromal compartment.


Assuntos
Colo do Útero/embriologia , Vagina/embriologia , Diferenciação Celular , Células Epiteliais , Feminino , Feto , Humanos , Recém-Nascido
11.
J Arthroplasty ; 36(1): 368-373, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32826147

RESUMO

BACKGROUND: Although the direct anterior approach (DAA) has become a standard for primary and revision total hip arthroplasty, it involves a high risk of injuring the lateral femoral cutaneous nerve (LFCN). The aim of this study is to examine the course of the LFCN in relation to various skin incisions and approach extensions used for the DAA. METHODS: We obtained 44 limbs and hemipelves from 22 formalin-preserved cadavers, in which LFCN was identified. All nerve branches of the LFCN were carefully traced. The branching pattern and the distribution in the thigh were described in relation to the standard approach for primary total hip arthroplasty, the skin crease bikini incision, the longitudinal extension, and the lazy S extension of the DAA. RESULTS: We found 31 (70.5%) Sartorius-type, 6 (13.6%) posterior-type, and 7 (15.9%) fan-type branching patterns of the LFCN. We observed 2.02 branches per hemipelvis. All fan-type LFCNs had 3 or more than 3 branches. We found that the main branch of the LFCN was medial to the primary DAA approach as well as to the lazy S extended DAA approach. The bikini incision and the incision for the longitudinal extension of the DAA crosses the main branch of the LFCN in 100% of cases. CONCLUSION: The fan-type pattern of the LFCN might be harmed by all skin incisions. Chances are high that LFCN branches could be jeopardized with a bikini-type incision and the longitudinal extension of the DAA. The risk of jeopardizing the LFCN with a lazy S-type distal extension is reduced.


Assuntos
Artroplastia de Quadril , Hepatite C Crônica , Artroplastia de Quadril/efeitos adversos , Nervo Femoral , Humanos , Reoperação , Coxa da Perna
12.
J Arthroplasty ; 36(3): 1138-1142, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33071031

RESUMO

BACKGROUND: During primary and revision total hip arthroplasty (THA) lesions of the superior gluteal nerve (SGN) can substantially compromise patient outcome. For the primary direct anterior approach (DAA) and its proximal approach extensions, especially the muscular branch entering the tensor fasciae latae (TFL) muscle is at risk. SGN lesions can result in fatty atrophy and functional loss of the TFL. Therefore, the course and branching pattern of the SGN were examined and related to the DAA and its proximal approach extension. The aim of the study is to describe safe and danger zones for the SGN with regard to the DAA and its proximal extensions. METHODS: Twenty-five formalin-fixed cadavers with 48 hemipelves were dissected. The course, distribution, and branching pattern of the SGN and its muscular branch inserting into the TFL muscle were investigated with regard to the DAA with the help of anatomical landmarks like the greater trochanter and the iliac tubercle. RESULTS: In 72.9% of the specimens the SGN passed the greater sciatic foramen superior to the piriformis muscle with one main trunk. The muscular branch of the SGN supplying the TFL divided from the main branch in 89.6% of the specimens at the level of the greater sciatic foramen. Before entering the TFL muscle the muscular branch showed a variable branching pattern in the interval between the gluteus medius and minimus. A danger zone for the SGN with regard to the DAA was found in the proximal fourth of the skin incision. CONCLUSION: Special care in proximal instrument placement should be taken during the DAA. When extending the DAA proximally manipulations in the proximal, caudal surgical window should be performed with the utmost care.


Assuntos
Artroplastia de Quadril , Hepatite C Crônica , Artroplastia de Quadril/efeitos adversos , Nádegas , Quadril , Humanos , Músculo Esquelético/cirurgia , Reoperação
13.
J Orofac Orthop ; 81(6): 427-439, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32897413

RESUMO

PURPOSE: This study investigates the accuracy of abutment transfer with current impression materials and provides a concise overview, including other relevant factors, in order to enable clinicians to make an informed decision about the optimal impression for this treatment procedure. METHODS: In all, 96 impressions of a cadaver head with two orthodontic miniscrews in place were taken with four common impression materials by two observers and using two methods of application. After pouring with a standard type IV stone and abutment transfer, all models and the upper jaw (which had been separated from the head) were scanned in a standard model scanner (Zirkonzahn® [Zirkohnzahn GmbH, Gais, Italy] S600 ARTI) and evaluated using a computer-aided design (CAD) program (GOM-Inspect [Gesellschaft für optische Messtechnik m.b.H., Braunschweig, Germany]). The deviations were measured at six points per screw and statistically evaluated with SPSS® (IBM, Chicago, IL, USA). RESULTS: Optimal values were obtained with biphasic polyvinylsiloxane, while monophasic polyvinylsiloxane, alginate and polyether also resulted in acceptable accuracy. Observer experience showed no effect and the method of application had only a minor effect on accuracy. CONCLUSIONS: Within the limitations of this study, it seems that all impression materials are suitable for miniscrew abutment transfer, provided that methods of intraoral adaptation of the orthodontic appliance can be employed. If higher accuracy is needed or for clinicians with less experienced, a biphasic polyvinylsiloxane impression with the putty-wash technique should be used as this combination reduces setting time. The most cost-effective version, alginate, can be used if the consequences of greater deviations can be handled. Caution is advised with polyether if undercuts are present.


Assuntos
Técnica de Moldagem Odontológica , Modelos Dentários , Materiais para Moldagem Odontológica , Alemanha , Itália
14.
Arch Orthop Trauma Surg ; 140(10): 1395-1401, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32108254

RESUMO

PURPOSE: The aim of this study was to assess the biomechanical properties of intact vertebra augmented using a local osteo-enhancement procedure to inject a triphasic calcium sulfate/calcium phosphate implant material. METHODS: Twenty-one fresh frozen human cadaver vertebra (Th11-L2) were randomized into three groups: treatment, sham, and control (n = 7 each). Treatment included vertebral body access, saline lavage to displace soft tissue and marrow elements, and injection of the implant material to fill approximately 20% of the vertebral body by volume. The sham group included all treatment steps, but without injection of the implant material. The control group consisted of untreated intact osteoporotic vertebra. Load at failure and displacement at failure for each of the three groups were measured in axial compression loading. RESULTS: The mean failure load of treated vertebra (4118 N) was significantly higher than either control (2841 N) or sham (2186 N) vertebra (p < 0.05 for: treatment vs. control, treatment vs. sham). Treated vertebra (1.11 mm) showed a significantly higher mean displacement at failure than sham vertebra (0.80 mm) (p < 0.05 for: treatment vs. sham). In the control group, the mean displacement at failure was 0.99 mm. CONCLUSIONS: This biomechanical study shows that a local osteo-enhancement procedure using a triphasic implant material significantly increases the load at failure and displacement at failure in cadaveric osteoporotic vertebra.


Assuntos
Substitutos Ósseos/farmacologia , Osteoporose/fisiopatologia , Coluna Vertebral , Fenômenos Biomecânicos , Fosfatos de Cálcio/farmacologia , Sulfato de Cálcio/farmacologia , Humanos , Coluna Vertebral/efeitos dos fármacos , Coluna Vertebral/fisiopatologia , Suporte de Carga
15.
Oral Surg Oral Med Oral Pathol Oral Radiol ; 129(1): 65-71.e7, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31636033

RESUMO

OBJECTIVE: The objective was to identify the lowest doses required to detect and measure the position of the inferior alveolar canal (IAC) on multidetector computed tomography (MDCT) images using filtered backprojection (FBP) and sinogram-affirmed iterative reconstructions (SAFIRE) 3 and SAFIRE 5. STUDY DESIGN: Four cadaveric mandibles were imaged using a reference protocol with standard dose and FBP and 3 ultra-low-dose protocols (LD1-LD3), using an MDCT scanner. All test examinations were reconstructed with FBP, SAFIRE 3, and SAFIRE 5. Subjective visibility of the IAC in the images and digital measurements of the height of the ridge above the IAC were recorded from test images and compared with those from the reference image using one-sample t tests, Bland-Altman plots, and linear regression. RESULTS: Subjective visibility comparable to the standard protocol was obtained with an 84.6% dose reduction using the LD2 protocol. No statistically significant difference was found between the height measurements from the reference protocol and any of the LD1 and LD2 protocols. The t tests indicated a significant difference between the measurements from the reference and all LD3 test protocols. SAFIRE did not have an advantage over FBP images. CONCLUSIONS: Significant dose reduction from the reference dose can allow adequate detection and measurements of the IAC.


Assuntos
Tomografia Computadorizada Multidetectores , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos , Humanos , Doses de Radiação , Cintilografia
16.
Ann Anat ; 226: 57-63, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31330307

RESUMO

BACKGROUND: Bone ageing is governed by the linked activities of short-lived osteoblasts and osteoclasts in conjunction with long-lived osteocytes present in osseous structure. Besides their maintenance function, osteogenic cells also gain specific positional information, which may potentially trigger ageing-associated cellular deviations in terminally differentiated osteocytes differently in cranial versus postcranial tissues. METHODS: We therefore investigated bone taken from deceased aged humans explanted at five distinct anatomical positions throughout the body and assessed physical and biological determinants applying radiologic and histologic measures. RESULTS: We were able to show that significantly more osteocytes reside in aged cortical bone at cranial positions than within axial or limb skeleton. These cellular states and conditions were not found in the corresponding trabecular bone, where osteocyte numbers remain also high at postcranial positions. Parallel comparative analyses of bone microstructure as analyzed by means of computer tomography showed no significant differences. CONCLUSIONS: Considering differences and commonalities regarding the bone samples, such as loading, mechanisms of ossification or the surrounding stromal cell compartment, our findings indicate that positional information laid down during ontogenetic processes is instructive during the entire life thus potentially also moulding spatial-specific mechanistic distinctions of bone ageing.


Assuntos
Envelhecimento/fisiologia , Osteócitos , Crânio/citologia , Crânio/crescimento & desenvolvimento , Idoso , Idoso de 80 Anos ou mais , Desenvolvimento Ósseo , Cadáver , Contagem de Células , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Regeneração , Esqueleto , Células Estromais/ultraestrutura , Microtomografia por Raio-X
17.
Clin Biomech (Bristol, Avon) ; 69: 64-70, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31302491

RESUMO

BACKGROUND: The aim of the current biomechanical study was to investigate a newly developed surgical technique for mallet fingers. The new method is based on the Ishiguro method which requires a K-wire through the distal interphalangeal joint for temporary fixation. The new technique avoids the joint trans fixation using a specially designed finger nail holder. This method was compared to the established Ishiguro's technique. METHODS: For biomechanical testing, 32 paired, fresh-frozen human fingers (Digit II-V) of 4 donors (ages 60 to 71 years) were used. The paired fingers were assigned to either the new method or Ishiguro's technique. The biomechanical testing consisted of a cyclic cantilever bending (2000 cycles, 1-7N) followed by a load to failure test. The groups were evaluated for plastic deformation, stiffness, change in stiffness during cyclic loading, subluxation and failure load by analysing force-deflect data and fluoroscopic images. FINDINGS: The nail fixation group showed significantly higher failure loads and stiffness than the trans fixation group. The values of plastic deformation were significantly lower in the nail fixation group. No differences were found in the change of stiffness. No subluxation was found in both groups. INTERPRETATION: In the current biomechanical study, nail fixation performed at least as good as Ishiguro's trans fixation technique. The results and ease of implementation indicate that the newly developed nail fixation technique might be a useful treatment method in daily clinical practice without the need of temporary joint trans-fixation avoiding possible associated problems. To establish this method, clinical trials will be necessary.


Assuntos
Fios Ortopédicos , Fixação Interna de Fraturas/métodos , Deformidades Adquiridas da Mão/fisiopatologia , Luxações Articulares , Unhas , Amplitude de Movimento Articular , Idoso , Fenômenos Biomecânicos , Cartilagem/patologia , Feminino , Articulações dos Dedos , Dedos , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade
18.
Oral Radiol ; 35(3): 280-286, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30484207

RESUMO

OBJECTIVE: To assess the linear measurements of edentulous ridges recorded from multidetector row computed tomography (MDCT) images obtained by a previously untested ultra-low dose in combination with filtered back-projection (FBP), adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR). METHODS: Three cadavers were imaged using a reference protocol with a standard dose and FBP (volume CT dose index (CTDIvol): 29.4 mGy) and two ultra-low-dose protocols, LD1 and LD2 (CTDIvol: 0.53 and 0.29 mGy). All test examinations were reconstructed with FBP, ASIR 50, ASIR 100, and MBIR. Linear measurements from the images of the edentulous ridges recorded from the test protocols were compared with those from the reference using a one-sample t test, Bland-Altman plots, and linear regression. Statistical significance was set at a p value of 0.05. RESULTS: The one-sample t test demonstrated a statistically significant difference between the measurements from the reference protocol and all test protocols. The difference was not clinically significant for the following three test protocols: LD1/FBP, LD1/ASIR 50, and LD2/FBP. Bland-Altman plots with linear regression showed no systematic variation between the measurements obtained with the reference protocol and these three test protocols. CONCLUSIONS: The lowest-dose protocol to demonstrate comparable measurements with a standard MDCT dose was CTDIvol 0.29 mGy with FBP. These results must be considered with caution for areas of the jaws with thin cortication. The results in areas of thin cortication should be verified by studies with larger sample sizes at such areas and comparison with true gold standard measurements.


Assuntos
Implantes Dentários , Tomografia Computadorizada Multidetectores , Humanos , Processamento de Imagem Assistida por Computador , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
19.
Int J Comput Assist Radiol Surg ; 13(11): 1853-1860, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29909528

RESUMO

PURPOSE: To compare the surface of computer-aided design (CAD) models of the maxilla produced using ultra-low MDCT doses combined with filtered backprojection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) reconstruction techniques with that produced from a standard dose/FBP protocol. METHODS: A cadaveric completely edentulous maxilla was imaged using a standard dose protocol (CTDIvol: 29.4 mGy) and FBP, in addition to 5 low dose test protocols (LD1-5) (CTDIvol: 4.19, 2.64, 0.99, 0.53, and 0.29 mGy) reconstructed with FBP, ASIR 50, ASIR 100, and MBIR. A CAD model from each test protocol was superimposed onto the reference model using the 'Best Fit Alignment' function. Differences between the test and reference models were analyzed as maximum and mean deviations, and root-mean-square of the deviations, and color-coded models were obtained which demonstrated the location, magnitude and direction of the deviations. RESULTS: Based upon the magnitude, size, and distribution of areas of deviations, CAD models from the following protocols were comparable to the reference model: FBP/LD1; ASIR 50/LD1 and LD2; ASIR 100/LD1, LD2, and LD3; MBIR/LD1. The following protocols demonstrated deviations mostly between 1-2 mm or under 1 mm but over large areas, and so their effect on surgical guide accuracy is questionable: FBP/LD2; MBIR/LD2, LD3, LD4, and LD5. The following protocols demonstrated large deviations over large areas and therefore were not comparable to the reference model: FBP/LD3, LD4, and LD5; ASIR 50/LD3, LD4, and LD5; ASIR 100/LD4, and LD5. CONCLUSIONS: When MDCT is used for CAD models of the jaws, dose reductions of 86% may be possible with FBP, 91% with ASIR 50, and 97% with ASIR 100. Analysis of the stability and accuracy of CAD/CAM surgical guides as directly related to the jaws is needed to confirm the results.


Assuntos
Desenho Assistido por Computador , Processamento de Imagem Assistida por Computador/métodos , Maxila/diagnóstico por imagem , Modelos Anatômicos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Cadáver , Feminino , Humanos , Masculino , Doses de Radiação , Cintilografia , Tomografia Computadorizada por Raios X/métodos
20.
Dentomaxillofac Radiol ; 47(8): 20170477, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29791199

RESUMO

OBJECTIVES: To compare subjective and objective localization of the inferior alveolar canal (IAC) on multidetector CT (MDCT) images obtained by ultralow doses in combination with the reconstruction techniques of filtered backprojection (FBP), adaptive statistical iterative reconstruction (ASIR), or model-based iterative reconstruction (MBIR) as compared to standard dose MDCT and FBP. METHODS: Three cadavers were imaged with a reference standard dose MDCT examination (volume CT dose index: 29.4 mGy) reconstructed with FBP and 5 low dose protocols (LD1-5) (volumeCT dose index: 4.19, 2.64, 0.99, 0.53, 0.29 mGy) reconstructed with FBP, ASIR 50, ASIR 100, and MBIR. Linear measurements from the crest of the ridge to the roof of the IAC were recorded. The results from the test protocols were compared with those from the reference using Bland-Altman plots. RESULTS: Only three test protocols allowed the identification of the position of the IAC on all the sample sites: LD1/FBP and LD1/ASIR 100 and LD2/FBP. All three protocols allowed identification of the IAC with comparable results to the reference dose protocol; the 95% confidence interval limits for the measurement differences were ± 0.41 mm, but the differences were not statistically significant. The calculated effective dose for the LD2 protocol, for a scan length of 5 cm, was 27.7 µSv. CONCLUSIONS: Using FBP, comparable IAC measurements were achieved with 91% reduction in dose compared with a standard exposure protocol. The use of ASIR and MBIR did not improve identification of the IAC in MDCT low dose images.


Assuntos
Mandíbula , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Algoritmos , Cadáver , Humanos , Mandíbula/diagnóstico por imagem , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...