Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Lab Chip ; 16(4): 660-7, 2016 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-26755271

RESUMO

In this study, we have investigated the motion of polystyrene microparticles inside a sessile droplet of water actuated by surface acoustic waves (SAWs), which produce an acoustic streaming flow (ASF) and impart an acoustic radiation force (ARF) on the particles. We have categorized four distinct regimes (R1-R4) of particle aggregation that depend on the particle diameter, the SAW frequency, the acoustic wave field (travelling or standing), the acoustic waves' attenuation length, and the droplet volume. The particles are concentrated at the centre of the droplet in the form of a bead (R1), around the periphery of the droplet in the form of a ring (R2), at the side of the droplet in the form of an isolated island (R3), and close to the centre of the droplet in the form of a smaller ring (R4). The ASF-based drag force, the travelling or standing SAW-based ARF, and the centrifugal force are utilized in various combinations to produce these distinct regimes. For simplicity, we fixed the fluid volume at 5 µL, varied the SAW actuation frequency (10, 20, 80, and 133 MHz), and tested several particle diameters in the range 1-30 µm to explicitly demonstrate the regimes R1-R4. We have further demonstrated the separation of particles (1 and 10 µm, 3 and 5 µm) using mixed regime configurations (R1 and R2, R2 and R4, respectively).

2.
Anal Chem ; 87(22): 11568-74, 2015 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-26487447

RESUMO

Temperature gradients (TGs) provide an effective approach to controlling solvated molecules and creating spatiotemporally varying thermal stimuli for biochemical research. Methods developed to date for generating TGs can only create a limited set of static temperature profiles. This article describes a method for establishing dynamic free-form TGs in polydimethylsiloxane (PDMS) as well as in gases and liquids in contact with the PDMS. The heating mechanism relies on the efficient acoustic absorption by the PDMS of high-frequency (5-200 MHz) surface acoustic waves (SAWs). MATLAB-aided actuation of a transducer enabled the generation and propagation of SAWs in a controlled fashion, which permitted spatiotemporal control over the temperature in the PDMS microstructures. This technique is exploited to perform one-shot high-resolution melting (HRM) analysis to detect single nucleotide polymorphisms (SNPs) in DNA. The experimental results displayed a 10-fold higher resolution and an enhanced signal-to-noise ratio compared to the results obtained using a conventional real-time PCR machine.


Assuntos
Equipamentos Descartáveis , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Temperatura , DNA/genética , Análise Mutacional de DNA , Dimetilpolisiloxanos/química , Desnaturação de Ácido Nucleico , Polimorfismo de Nucleotídeo Único/genética
3.
Sci Rep ; 5: 15170, 2015 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-26471003

RESUMO

Optofluidics is one of the most remarkable areas in the field of microfluidic research. Particle manipulation with optofluidic platforms has become central to optical chromatography, biotechnology, and µ-total analysis systems. Optical manipulation of particles depends on their sizes and refractive indices (n), which occasionally leads to undesirable separation consequences when their optical mobilities are identical. Here, we demonstrate rapid and dynamic particle manipulation according to n, regardless of size. Integrated liquid-core/solid-cladding (LS) and liquid-core/liquid-cladding (L(2)) waveguides were fabricated and their characteristics were experimentally and theoretically determined. The high and low n particles showed the opposite behaviors by controlling the contrast of their n values to those of the working fluids. The LS waveguide was found to successfully manipulate particles according to n, and the L(2) waveguide was found to provide additional system stability and flexibility, compared to the LS system.

4.
Sci Rep ; 5: 11851, 2015 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-26138310

RESUMO

We report an observation of rapid (exceeding 2,000 K/s) heating of polydimethylsiloxane (PDMS), one of the most popular microchannel materials, under cyclic loadings at high (~MHz) frequencies. A microheater was developed based on the finding. The heating mechanism utilized vibration damping in PDMS induced by sound waves that were generated and precisely controlled using a conventional surface acoustic wave (SAW) microfluidic system. The refraction of SAW into the PDMS microchip, called the leaky SAW, takes a form of bulk wave and rapidly heats the microchannels in a volumetric manner. The penetration depths were measured to range from 210 µm to 1290 µm, enough to cover most sizes of microchannels. The energy conversion efficiency was SAW frequency-dependent and measured to be the highest at around 30 MHz. Independent actuation of each interdigital transducer (IDT) enabled independent manipulation of SAWs, permitting spatiotemporal control of temperature on the microchip. All the advantages of this microheater facilitated a two-step continuous flow polymerase chain reaction (CFPCR) to achieve the billion-fold amplification of a 134 bp DNA amplicon in less than 3 min.

5.
Anal Chem ; 87(9): 4627-32, 2015 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-25800052

RESUMO

We demonstrate a miniaturized acoustofluidic device composed of a pair of slanted interdigitated transducers (SIDTs) and a polydimethylsiloxane microchannel for achieving size-selective separation and exchange of medium around polystyrene particles in a continuous, label-free, and contactless fashion. The SIDTs, deposited parallel to each other, produce tunable traveling surface acoustic waves (TSAWs) at desired locations, which, in turn, yield an anechoic corner inside the microchannel that is used to selectively deflect particles of choice from their streamlines. The TSAWs with frequency fR originating from the right SIDT and propagating left toward the microchannel normal to the fluid flow direction, laterally deflect larger particles with diameter d1 from the hydrodynamically focused sample fluid that carries other particles as well with diameters d2 and d3, such that d1 > d2 > d3. The deflected particles (d1) are pushed into the top-left corner of the microchannel. Downstream, the TSAWs with frequency fL, such that fL > fR, disseminating from the left SIDT, deflect the medium-sized particles (d2) rightward, leaving behind the larger particles (d1) unaffected in the top-left anechoic corner and the smaller particles (d3) in the middle of the microchannel, thereby achieving particle separation. A particle not present in the anechoic corner could be deflected rightward to realize twice the medium exchange. In this work, the three-way separation of polystyrene particles with diameters of 3, 4.2, and 5 µm and 3, 5, and 7 µm is achieved using two separate devices. Moreover, these devices are used to demonstrate multimedium exchange around polystyrene particles ∼5 µm and 7 µm in diameter.

6.
Lab Chip ; 14(24): 4665-72, 2014 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-25312065

RESUMO

Submicron separation is the segregation of particles having a diameter difference of less than one micrometre. We present an acoustofluidic particle separator with submicron separation resolution to study the continuous, label-free, and contactless separation of polystyrene (PS) particles based on their acoustofluidic parameters such as size, density, compressibility and shape. In this work, the submicron separation of PS microspheres, having a marginal size difference, is achieved inside a polydimethylsiloxane (PDMS) microfluidic channel via travelling surface acoustic waves (TSAWs). The TSAWs of different frequencies (200, 192, 155, and 129 MHz), propagating normal to the fluid flow direction inside the PDMS microchannel, realized continuous separation of particles with a diameter difference as low as 200 nm. A theoretical framework based on the rigid and elastic theories is presented to support the experimental results.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Microesferas , Som , Dimetilpolisiloxanos , Tamanho da Partícula , Poliestirenos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...