Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Biochem ; 47(10-11): 901-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24954692

RESUMO

OBJECTIVES: Annexin A3 (ANXA3) is a potential marker for prostate cancer (PCa). We aimed to develop robust immunoassays suitable for quantifying ANXA3 in urine samples obtained following digital rectal examination (DRE) in order to facilitate the diagnostic performance evaluation of this marker. DESIGN AND METHODS: Anti-ANXA3 monoclonal antibodies were generated and their epitopes mapped. Two different ANXA3 assay prototypes were established on the VIDAS® automated immunoanalyser and analytical validation was carried out using post-DRE urine samples obtained from patients with PCa (n=23) or benign prostate hyperplasia (n=31). RESULTS: The assays had the same capture antibody (TGC44) but different detection antibodies (13A12 or 5C5), recognizing novel distinct epitopes. Both had a lower limit of quantification <1ng/mL and were highly specific for ANXA3, not cross-reacting with other annexins. Interassay imprecision was ≤11% and ≤15% for 13A12 and 5C5 assays, respectively. Surprisingly, a total lack of correlation was observed between ANXA3 levels measured by these two assays in post-DRE urines, indicating detection of distinct antigenic variants. Two freeze-thaw cycles did not affect analyte stability in either assay, whereas a lack of stability of antigenic variants was observed when samples were stored at -80°C for 1month. CONCLUSIONS: Two different antigenic variants of ANXA3 are present in post-DRE urines and their clinical significance for diagnosis of prostate cancer should be further investigated. These variants are not stable over time in samples preserved at -80°C. Until this issue is resolved, ANXA3 should only be measured in freshly collected samples.


Assuntos
Anexina A3/urina , Biomarcadores Tumorais/urina , Exame Retal Digital , Proteínas de Neoplasias/urina , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/urina , Animais , Anticorpos Monoclonais Murinos/química , Anticorpos Antineoplásicos/química , Criopreservação , Ensaio de Imunoadsorção Enzimática , Epitopos/urina , Humanos , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Estabilidade Proteica
2.
FEBS J ; 278(24): 4845-59, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21973086

RESUMO

Colorectal cancer (CRC) is a major public health issue worldwide, and novel tumor markers may contribute to its efficient management by helping in early detection, prognosis or surveillance of disease. The aim of our study was to identify new serum biomarkers for CRC, and we followed a phased biomarker discovery and validation process to obtain an accurate preliminary assessment of potential clinical utility. We compared colonic tumors and matched normal tissue from 15 CRC patients, using two-dimensional difference gel electrophoresis (2D-DIGE), and identified 17 proteins that had significant differential expression. These results were further confirmed by western blotting for heat shock protein (HSP) 60, glutathione-S-transferase Pi, α-enolase, T-complex protein 1 subunit ß, and leukocyte elastase inhibitor, and by immunohistochemistry for HSP60. Using mAbs raised against HSP60, we developed a reliable (precision of 5-15%) and sensitive (0.3 ng·mL(-1)) immunoassay for the detection of HSP60 in serum. Elevated levels of HSP60 were found in serum from CRC patients in two independent cohorts; the receiver-operating characteristic curve obtained in 112 patients with CRC and 90 healthy controls had an area under the curve (AUC) of 0.70, which was identical to the AUC of carcinoembryonic antigen. Combination of serum markers improved clinical performance: the AUC of a three-marker logistic regression model combining HSP60, carcinoembryonic antigen and carbohydrate antigen 19-9 reached 0.77. Serum HSP60 appeared to be more specific for late-stage CRC; therefore, future studies should evaluate its utility for determining prognosis or monitoring therapy rather than early detection.


Assuntos
Chaperonina 60/sangue , Neoplasias Colorretais/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/sangue , Western Blotting , Antígeno CA-19-9/sangue , Antígeno Carcinoembrionário/sangue , Neoplasias Colorretais/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Eletroforese em Gel Diferencial Bidimensional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...