Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ear Hear ; 42(2): 323-333, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32826506

RESUMO

OBJECTIVES: Recent studies have shown that cochlear duct length (CDL) varies among individuals and could significantly influence the final position of the electrode and its trajectory in the cochlea. Given this, we hypothesized that the degree of modiolar proximity of novel slim modiolar electrodes, such as CI532 and CI632, can also be affected by CDL. To test this hypothesis, we retrospectively evaluated individual CDL to determine if there is any significant correlation of CDL with degree of modiolar proximity. METHODS: Fifty-one ears from 38 subjects implanted with slim modiolar electrodes by a single surgeon through the round window approach using the pull-back technique were included. Our cohort was classified according to the deafness onset (congenital versus postlingual) and the degree of modiolar proximity (less versus tight) with reference to the spiral diameter made by the slim modiolar electrodes in situ on transorbital x ray. We then analyzed the CDL and its metrics using a readily available surgical preplanning tool (OTOPLAN) to obtain comparable data. RESULTS: Among 30 ears associated with congenital deafness, 9 ears (30%) showed less modiolar proximity, while none of the 21 ears from 19 subjects with postlingual deafness exhibited "less modiolar proximity" based on our criteria. In this study, CDL showed significant variation among subjects. Importantly, a significant inverse correlation between spiral diameter and CDL (ρ = -0.581, p < 0.001) was found, showing that shorter CDLs have longer spiral diameter and less modiolar proximity. Moreover, further pull-back technique characterized by pulling out the electrode a little bit more in cases with shorter CDL, if not always, exhibited tighter modiolar proximity. CONCLUSION: A preponderance of less modiolar proximity of the electrode was observed exclusively among congenital deafness cases, demonstrated by a less tight spiral configuration even under the pull-back technique. Our data suggest that shorter CDL is associated with a less tight spiral configuration of slim modiolar electrodes postoperatively. Depending on the insertion technique, the differential degree of modiolar proximity of slim modiolar electrodes can be alleviated in cases with short CDL, which justifies cochlear duct length-based customized insertion of slim modiolar electrodes.


Assuntos
Implante Coclear , Implantes Cocleares , Cóclea/cirurgia , Ducto Coclear , Eletrodos Implantados , Humanos , Estudos Retrospectivos
3.
Conf Proc IEEE Eng Med Biol Soc ; 2005: 5257-9, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-17281435

RESUMO

A new cochlear implant system for animal experiments is proposed. The system uses a DSP-based sound processor to implement the six-channel continuous interleaved sampling (CIS) speech processing strategy. An infra-red telemetry is designed to remotely connect the power-demanding sound processor to receiver/stimulator attached on the animal. This enables the animal to move freely. The receiver/stimulator consumes about 40mW, thus can operates for about 200hours without changing battery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA