Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Indoor Air ; 27(6): 1141-1153, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28378908

RESUMO

The aim of this laboratory experiment was to study the effects of ventilation rate, and related changes in air quality, predominantly bioeffluents, on work performance, perceived indoor air quality, and health symptoms in a typical conditions of modern open-plan office with low material and equipment emissions. In Condition A, outdoor air flow rate of 28.2 l/s person (CO2 level 540 ppm) was applied and in Condition B, outdoor air flow rate was 2.3 l/s person (CO2 level 2260 ppm). CO2 concentration level was used as an indicator of bioeffluents. Performance was measured with seven different tasks which measure different cognitive processes. Thirty-six subjects participated in the experiment. The exposure time was 4 hours. Condition B had a weak negative effect on performance only in the information retrieval tasks. Condition B increased slightly subjective workload and perceived fatigue. No effects on health symptoms were found. The intensity of symptoms was low in both conditions. The experimental condition had an effect on perceived air quality and observed odor intensity only in the beginning of the session. Although the room temperature was controlled in both conditions, the heat was perceived to impair the performance more in Condition B.


Assuntos
Poluição do Ar em Ambientes Fechados , Ventilação , Desempenho Profissional/estatística & dados numéricos , Adulto , Dióxido de Carbono/análise , Fadiga/etiologia , Feminino , Humanos , Masculino , Carga de Trabalho/psicologia , Adulto Jovem
2.
Indoor Air ; 26(2): 286-97, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25866136

RESUMO

The aim of the study was to determine the effect of a temperature of 29°C on performance in tasks involving different cognitive demands and to assess the effect on perceived performance, subjective workload, thermal comfort, perceived working conditions, cognitive fatigue, and somatic symptoms in a laboratory with realistic office environment. A comparison was made with a temperature of 23°C. Performance was measured on the basis of six different tasks that reflect different stages of cognitive performance. Thirty-three students participated in the experiment. The exposure time was 3.5 h in both thermal conditions. Performance was negatively affected by slightly warm temperature in the N-back working memory task. Temperature had no effect on performance in other tasks focusing on psychomotor, working memory, attention, or long-term memory capabilities. Temperature had no effect on perceived performance. However, slightly warm temperature caused concentration difficulties. Throat symptoms were found to increase over time at 29°C, but no temporal change was seen at 23°C. No effect of temperature on other symptoms was found. As expected, the differences in thermal comfort were significant. Women perceived a temperature of 23°C colder than men.


Assuntos
Temperatura Alta , Desempenho Profissional/estatística & dados numéricos , Local de Trabalho , Atenção , Feminino , Humanos , Masculino , Memória , Percepção , Análise e Desempenho de Tarefas
3.
Indoor Air ; 19(6): 454-67, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19702627

RESUMO

UNLABELLED: This study examined how the intelligibility of irrelevant speech, determined with the Speech Transmission Index (STI), affects demanding cognitive task performance. Experiment was carried out in a laboratory that resembled an open-plan office. Three speech conditions were tested corresponding to a private office (STI = 0.10), an acoustically excellent open office (STI = 0.35) and an acoustically poor open office (STI = 0.65). All conditions were presented at equal level, 48 dBA. The STI was adjusted by the relative levels of speech and masking sound. Thirty-seven students participated in the experiment that lasted for 4 h. All participants performed five tasks in each of the three speech conditions. Questionnaires were used to assess subjective perceptions of the speech conditions. Performance in the operation span task, the serial recall and the activation of prior knowledge from long-term memory were deteriorated in the speech condition with the highest speech intelligibility (STI = 0.65) in comparison with the other two conditions (STI = 0.10 and STI = 0.35). Unlike performance measures, questionnaire results showed consistent differences among all three speech conditions, i.e. subjective disturbance increased with ascending speech intelligibility. Thus, subjective comfort was disturbed more easily than performance. The results support the use of STI as an essential room acoustic design measure in open-plan offices. PRACTICAL IMPLICATIONS: Reduction of speech intelligibility in office environments by proper acoustic design would be beneficial in terms of both work performance and subjective comfort. Proper acoustic design requires both the use of high acoustic absorption and an appropriate masking sound.


Assuntos
Acústica , Cognição , Ruído Ocupacional , Inteligibilidade da Fala , Análise e Desempenho de Tarefas , Adulto , Eficiência , Ambiente Controlado , Feminino , Humanos , Masculino , Memória , Psicometria , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...