Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 406(3): 915-22, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24337134

RESUMO

A novel analytical method using hydrophilic interaction liquid chromatography combined with electrospray tandem mass spectrometry for metabolic profiling of free, underivatized amino acids is presented. The separation uses a zwitterionic modified silica-based stationary phase with 1.8-µm particle size functionalized with ammonium sulfonic acid groups. Quantification is based on external standard calibration using a Pichia pastoris cell extract grown on uniformly (13)C labeled glucose as an internal standard. The absolute limits of detection in the cellular matrix were in the subpicomolar range. Measurement accuracy was assessed by analyzing NIST Standard Reference Material 2389a, which provides certified values for 17 amino acids. The recovery of the amino acids ranged between 65 % (proline) and 120 % (lysine), with excellent repeatability precision below 2.5 % (n = 5). Only, cystine showed poor recovery (29 %) and repeatability precision (13 %). Generally, the long-term precision obtained by hydrophilic interaction liquid chromatography-tandem mass spectrometry was excellent, being on average less than 9 % over 20 h of measurement time. Moreover, the novel separation method had average repeatability and reproducibility of the chromatographic peak width over time periods of 20 h and 6 months of 8 and 15 %, respectively, demonstrating its high robustness in routine analysis of cellular samples. Large concentration differences depending on the amino acid were found in the cell extracts, typically ranging from 0.002 nmol per milligram of cell dry weight (cystine) to 56 nmol per milligram of cell dry weight (arginine and glutamic acid).


Assuntos
Aminoácidos/química , Isótopos de Carbono/análise , Técnicas de Química Analítica/métodos , Cromatografia Líquida , Metaboloma , Espectrometria de Massas em Tandem , Calibragem , Proteínas Fúngicas/química , Interações Hidrofóbicas e Hidrofílicas , Limite de Detecção , Tamanho da Partícula , Padrões de Referência , Reprodutibilidade dos Testes , Fatores de Tempo
2.
Anal Bioanal Chem ; 405(15): 5133-46, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23559335

RESUMO

Metabolic flux analysis implies mass isotopomer distribution analysis and determination of mass isotopologue fractions (IFs) of proteinogenic amino acids of cell cultures. In this work, for the first time, this type of analysis is comprehensively investigated in terms of measurement uncertainty by calculating and comparing budgets for different mass spectrometric techniques. The calculations addressed amino acids of Pichia pastoris grown on 10% uniformly (13)C labeled glucose. Typically, such experiments revealed an enrichment of (13)C by at least one order of magnitude in all proteinogenic amino acids. Liquid chromatography-time-of-flight mass spectrometry (LC-TOFMS), liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) analyses were performed. The samples were diluted to fit the linear dynamic range of the mass spectrometers used (10 µM amino acid concentration). The total combined uncertainties of IFs as well as the major uncertainty contributions affecting the IFs were determined for phenylalanine, which was selected as exemplary model compound. A bottom-up uncertainty propagation was performed according to Quantifying Uncertainty in Analytical Measurement and using the Monte Carlo method by considering all factors leading to an IF, i.e., the process of measurement and the addition of (13)C-glucose. Excellent relative expanded uncertainties (k = 1) of 0.32, 0.75, and 0.96% were obtained for an IF value of 0.7 by LC-MS/MS, GC-MS, and LC-TOFMS, respectively. The major source of uncertainty, with a relative contribution of 20-80% of the total uncertainty, was attributed to the signal intensity (absolute counts) uncertainty calculated according to Poisson counting statistics, regardless which of the mass spectrometry platforms was used. Uncertainty due to measurement repeatability was of importance in LC-MS/MS, showing a relative contribution up to 47% of the total uncertainty, whereas for GC-MS and LC-TOFMS the average contribution was lower (30 and 15%, respectively). Moreover, the IF actually present also depends on the isotopic purity of the carbon sources. Therefore, in the uncertainty calculation a carbon source purity factor was introduced and a minor contribution to the total uncertainty was observed. The results obtained by uncertainty calculation performed according to the Monte Carlo method were in agreement with the uncertainty value of the Kragten approach and showed a Gaussian distribution.


Assuntos
Aminoácidos/metabolismo , Espectrometria de Massas/métodos , Metabolômica/métodos , Metabolômica/normas , Pichia/metabolismo , Incerteza , Aminoácidos/química , Cromatografia Líquida/métodos , Marcação por Isótopo , Pichia/química , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
3.
J Chromatogr A ; 1015(1-2): 1-10, 2003 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-14570314

RESUMO

Three chloroformate reagents, ethyl chloroformate (ECF), methyl chloroformate (MCF) and menthyl chloroformate (MenCF), have been used for the derivatisation of seleno amino acids and their performance was compared. Chromatographic parameters and the inertness of the different instrumental configurations used (gas chromatography-atomic emission detection (GC-AED), and GC-MS) were shown to have a significant influence on the detection of various seleno amino acids (selenomethione, selenoethione and selenocysteine) and some sulphur-containing amino acids (methionine, cysteine, cystine and methylcysteine) which were included in the experiments for comparison. Methyl chloroformate was the preferred derivatisation reagent, since it generally performed best in terms of derivatisation yield and reproducibility and also showed less significant conditioning effects than ethyl chloroformate. Methyl and ethyl chloroformate derivatives of selenomethionine, selenoethionine, cysteine and methionine were detectable, while the detection of the menthyl chloroformate derivatives of selenocystine and cystine was not reproducible. Overall efficiencies for the determination of selenomethionine and selenoethionine from aqueous extracts ranged from 40 to 100% for methyl chloroformate, over 30-75% for ethyl chloroformate to 15-70% for menthyl chloroformate for different series measured over a period of months. The relative standard deviation of the method for the methyl and menthyl chloroformate derivatisation ranged from 7 to 13% without internal standard and was improved to 2% for the determination of selenomethionine using selenoethionine as internal standard. This indicates that, despite the limited reproducibility of the method, its repeatability is good enough to allow accurate determination of seleno amino acids, which was also demonstrated by the analysis of selenium supplementation tablets for human diet that contained selenomethionine.


Assuntos
Aminoácidos/química , Formiatos/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Padrões de Referência
4.
J Chromatogr A ; 917(1-2): 367-74, 2001 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-11403490

RESUMO

The suitability of various sample containers (i.e. standard Tedlar sample bags, black/clear layered Tedlar sample bags and Silcosteel sample cylinders) was examined for a gaseous multicomponent standard containing methylmercaptan, ethylmercaptan, dimethyl sulfide, ethylmethyl sulfide, 2-propylmercaptan, 1-propylmercaptan, 2-butylmercaptan, diethyl sulfide and 1-butylmercaptan (1 mg/m3 each in nitrogen). In the black/clear layered Tedlar sample bags, significant losses (up to 10% for methylmercaptan as the most critical component) were observed after 2 days, whereas in the standard Tedlar sample bags the recovery of methylmercaptan was approximately 90% even after 1 week. The Silcosteel sample cylinders were suitable for sampling of volatile sulfur compounds with respect to the stability of the analytes, but the recoveries exceeded 100% especially for the higher boiling compounds, which was attributed to enrichment effects on parts of the sampling system.


Assuntos
Compostos de Enxofre/química , Cinética , Sensibilidade e Especificidade , Volatilização
5.
Fresenius J Anal Chem ; 366(4): 329-31, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11220312

RESUMO

The surfaces of commercially available polydimethylsiloxane (PDMS) and Carboxen-PDMS fibers for solid-phase microextraction (SPME) were investigated by optical and electron microscopy. Damage to the coating as well as contamination of new fibers and a highly variable number of pores in Carboxen-PDMS coatings were observed. Together with the contamination of the fibers during their use with metallic particles originating from the SPME fiber holder they are possible explanations for the problems encountered in the analysis of organolead, organotin and organosulfur compounds, such as artifact formation and low repeatability.

6.
J Chromatogr A ; 852(2): 589-95, 1999 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-10481995

RESUMO

The applicability of two different types of Nafion membrane dryers (based on counter-current flow and desiccant drying) and of a new ozone scrubbing material, polyphenylene sulphide wool (noXon-S), to adsorptive sampling of selected volatile sulphur compounds (methanethiol, dimethyl sulphide, isopropanethiol and isobutanethiol) is investigated at the low ppb (v/v) level (1-5 ppb). No analyte losses occur with either type of dryer at relative humidities (RH) of < or = 50%, while at higher RH values particularly the thiols tend to be lost (between 6 and 32%) even after conditioning. The actual losses depend more on the state of the individual permeation membrane rather than on the type of dryer. NoXon-S is a highly suitable ozone scrubber material for sulphur compounds since it efficiently removes ozone without retainment of the analytes and without the formation of blanks or artefacts from the scrubber material. The combined use of a Nafion membrane dryer and a noXon-S ozone scrubber is thus recommended for artifact-free sampling of sulphur compounds.


Assuntos
Poluentes Atmosféricos/análise , Técnicas de Química Analítica/instrumentação , Compostos de Sulfidrila/análise , Sulfetos/análise , Membranas Artificiais , Ozônio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...