Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Radiat Oncol ; 8(1): 101108, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36483065

RESUMO

Purpose: This study aimed to analyze the effect of body mass factors (BMFs) on setup errors in gynecologic tumors, and whether the planned tumor volumes (PTVs) are adequate for obese patients. Methods: This was a retrospective study of 46 consecutive female patients with gynecologic tumors who were treated with volumetric modulated arc therapy. Setup accuracy was verified using daily cone beam computed tomography. Accuracy was determined for each fraction by testing 2 different PTVs (cutoff I = ≤0.7 cm; cutoff II = ≤1.0 cm). A pooled analysis was conducted to test the association between accuracy levels (within vs beyond PTV) and the mean and variance of body mass index (BMI), umbilical (UC), and hip circumference (HC). A receiver operating characteristics curve analysis was carried out to test the sensitivity of BMI, UC, and HC in predicting inaccurate setup. Results: A significant association between BMFs and level of accuracy was observed in the lateral and vertical directions, but not in the longitudinal direction. In the lateral direction, inaccurate setups were associated with a greater BMI (mean difference: ∼3.50 kg/m2; P = .001), UC (∼10 cm), and HC (∼8 cm) compared with accurate setups (P < .001). With respect to the vertical direction, inaccurate setups (>0.7 cm margin [cutoff I]) were associated with a greater BMI (mean difference = 7.4 kg/m2; P = .001), UC (5.3 cm; P < .001), and HC (16.0 cm; P < .001) with reference to accurate setups. The receiver operating characteristics curve analysis showed that a BMI >31.4 kg/m2 was predictive for inaccurate setup in the vertical direction with 90.0% sensitivity with respect to cutoff I. Furthermore, a BMI >30.3 kg/m2 was predictive for inaccurate setup in the lateral direction with 92.5% sensitivity with respect to cutoff II. Conclusions: The accuracy of radiation therapy setups for gynecologic tumors is highly sensitive to patients' BMI, notably in the lateral and vertical directions. We suggest that daily cone beam computed tomography should be applied on patients with a BMI >30.3 kg/m2, using customized protocols that are lower in dose and comparable in image quality.

2.
Adv Radiat Oncol ; 6(6): 100742, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34934853

RESUMO

PURPOSE: The study assessed the effectiveness of a site-specific video educational material in improving patient understanding and confidence regarding radiation therapy trajectory. METHODS AND MATERIALS: A quasi experimental longitudinal pretest posttest study was conducted at a referral radiation therapy center from May 2020 to September 2020. It included 52 adult patients admitted for a first course radical radiation therapy. One generic and 6 site-specific (breast, pelvis, head and neck, brain, chest and abdomen, and bladder) animated cartoon videos were developed in house to provide concise overview of the overall patient's trajectory in radiation therapy, with full visual description of the procedures and specific preparation measures. A 14-item questionnaire was designed to assess pre- and postintervention levels of understanding and confidence of patients, with calculation of and an understanding and confidence score (UCS), range 0-14. RESULTS: The mean (standard deviation) UCS in pre- and postintervention was 9.36 (2.48) and 11.92 (1.34) out of 14, respectively, indicating a mean increase of 2.57 subsequent to the intervention (P < .001). The effect size was large with a Cohen's d = 1.01. Of the 14 dimensions explored, 8 were observed to have remarkable improvement, notably understanding the purpose of the tattoo mark, reason of daily or weekly imaging, and what to expect with radiation therapy. Participants with poor reading ability had greater increase in UCS (ΔUCS = 4.25 vs ≤2.33) and in 5 out of 8 dimensions with remarkable improvement. CONCLUSIONS: The use of digital educational material in radiation oncology meets the urgent need for providing patients with concise and site-specific information, while sparing extra hospital visits to meet education coordinators during the COVID-19 crisis. Additional studies are warranted to assess both the clinical and long-term effectiveness of the educational material, using a longitudinal controlled design.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...