Open Heart ; 10(1)2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36750275

RESUMO

OBJECTIVE: The onset of new conduction abnormalities requiring permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) is still a relevant adverse event. The main objective of this registry was to identify modifiable procedural risk factors for an improved outcome (lower rate of PPI) after TAVI in patients at high risk of PPI. METHODS: Patients from four European centres receiving a balloon-expandable TAVI (Edwards SAPIEN 3/3 Ultra) and considered at high risk of PPI (pre-existing conduction disturbance, heavily calcified left ventricular outflow tract or short membranous septum) were prospectively enrolled into registry. RESULTS: A total of 300 patients were included: 42 (14.0%) required PPI after TAVI and 258 (86.0%) did not. Patients with PPI had a longer intensive care unit plus intermediate care stay (65.7 vs 16.3 hours, p<0.001), general ward care stay (6.9 vs 5.3 days, p=0.004) and later discharge (8.6 vs 5.0 days, p<0.001). Of the baseline variables, only pre-existing right bundle branch block at baseline (OR 6.8, 95% CI 2.5 to 18.1) was significantly associated with PPI in the multivariable analysis. Among procedure-related variables, oversizing had the highest impact on the rate of PPI: higher than manufacturer-recommended sizing, mean area oversizing as well as the use of the 29 mm valve (OR 3.4, 95% CI 1.4 to 8.5, p=0.008) all were significantly associated with PPI. Rates were higher with the SAPIEN 3 (16.1%) vs SAPIEN 3 Ultra (8.5%), although not statistically significant but potentially associated with valve sizing. Implantation depth and postdelivery balloon dilatation also tended to affect PPI rates but without a statistical significance. CONCLUSION: Valve oversizing is a strong procedure-related risk factor for PPI following TAVI. The clinical impact of the valve type (SAPIEN 3), implantation depth, and postdelivery balloon dilatation did not reach significance and may reflect already refined procedures in the participating centres, giving attention to these avoidable risk factors. TRIAL REGISTRATION NUMBER: NCT03497611.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos
2.
Pharmgenomics Pers Med ; 14: 893-903, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34321906

RESUMO

BACKGROUND: Complement component 5a (C5a) is a highly potent anaphylatoxin with a variety of pro-inflammatory effects. C5a contributes to progression of atherosclerosis and inhibition of the receptor (C5aR) might offer a therapeutic strategy in this regard. Single nucleotide polymorphisms (SNPs) of the C5 gene may modify protein expression levels and therefore function of C5a and C5aR. This study aimed to examine associations between clinically relevant C5a SNPs and the prognosis of patients with symptomatic coronary artery disease (CAD). Furthermore, we sought to investigate the influence of C5 SNPs on C5aR platelet surface expression and circulating C5a levels. METHODS: C5 variants (rs25681, rs17611, rs17216529, rs12237774, rs41258306, and rs10985126) were analyzed in a consecutive cohort of 833 patients suffering from symptomatic coronary artery disease (CAD). Circulating C5a levels were determined in 116 patients whereas C5aR platelet surface expression was measured in 473 CAD patients. Endpoints included all-cause mortality, myocardial infarction (MI), and ischemic stroke (IS). Homozygous carriers (HC) of the minor allele (rs10985126) showed significantly higher all-cause mortality than major allele carriers. While we could not find significant associations between rs10985126 allele frequency and C5aR platelet surfazl ce expression, significantly elevated levels of circulating C5a were found in HC of the minor allele of the respective genotype. rs17216529 allele frequency correlated with the composite combined endpoint and bleeding events. However, since the number of HC of the minor allele of this genotype was low, we cannot draw a robust conclusion about the observed associations. CONCLUSION: In this study, we provide evidence for the prognostic relevance of rs10985126 in CAD patients. C5 rs10985126 may serve as a prognostic biomarker for risk stratification in high-risk CAD patients and consequently promote tailored therapies.

3.
Heart Vessels ; 35(12): 1735-1745, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32591894

RESUMO

Permanent pacemaker implantation (PPI) is a widely recognized complication associated with TAVI (incidence up to 20%). Smaller registries have identified several variables associated with PPI. The objective was to validate patient- and transcatheter aortic valve implantation (TAVI)-related procedural variables associated with PPI. We performed a retrospective analysis of patients from six European centers undergoing TAVI with the Edwards SAPIEN 3 prosthesis. Baseline variables and pre-procedural ECG characteristics and CT-scans were taken into account. Data for 1745 patients were collected; 191 (10.9%) required PPI after TAVI. The baseline variables pulmonary hypertension (OR 1.64; 95% CI 1.01-2.59), QRS duration > 117 ms (OR 2.58; 95% CI 1.73-3.84), right bundle branch block (RBBB; OR 5.14; 95% CI 3.39-7.72), left anterior hemi block (OR 1.92; 95% CI 1.19-3.02) and first-degree atrioventricular block (AVB, OR 1.63; 95%CI 1.05-2.46) were significantly associated with PPI. RBBB (OR 8.11; 95% CI 3.19-21.86) and first-degree AVB (OR 2.39; 95% CI 1.18-4.66) remained significantly associated in a multivariate analysis. Procedure-related variables included access site (TF; OR 1.97; 95% CI 1.07-4.05), implanted valve size (29 mm; OR 1.88; 95% CI 1.35-2.59), mean TAVI valve implantation depth below the annulus > 30% (OR 3.75; 95% CI 2.01-6.98). Patients receiving PPI had longer ICU stays and later discharges. Acute kidney injury stage 2/3 was more common in patients with PPI until discharge (15.2 vs. 3.1%; p = 0.007), but was not statistically significant thereafter. Further differences in outcomes at 30 days did not reach significance. The data will aid pre- and post-procedural patient management and prevent adverse long-term outcomes.Clinical Trial: NCT03497611.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão/efeitos adversos , Estimulação Cardíaca Artificial , Bloqueio Cardíaco/terapia , Frequência Cardíaca , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Europa (Continente) , Feminino , Bloqueio Cardíaco/diagnóstico , Bloqueio Cardíaco/etiologia , Bloqueio Cardíaco/fisiopatologia , Humanos , Masculino , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Resuscitation ; 137: 205-212, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30790690

RESUMO

AIMS: Cangrelor has a potentially favorable pharmacodynamic profile in cardiogenic shock (CS). We aimed to evaluate the clinical course of CS patients undergoing percutaneous coronary intervention (PCI) treated with cangrelor. METHODS AND RESULTS: We retrospectively identified 136 CS patients treated with cangrelor. Patients were 1:1 matched to CS patients from the IABP-SHOCK II trial not receiving cangrelor by age, sex, cardiac arrest, type of myocardial infarction, culprit lesion, glycoprotein IIb/IIIa inhibitor, and oral P2Y12-receptor inhibitor and followed-up for 12 months. The study cohort consisted of 88 matched pairs. Thirty-day and 12-month mortality was 29.5% and 34.1% in cangrelor-treated patients and 36.4% and 47.1% in control group (P = 0.34 and P = 0.08, respectively). The rate of definite acute stent thrombosis was 2.3% in both groups. Moderate and severe bleeding events occurred in 21.6% in the cangrelor and 19.3% in the control group (P = 0.71). Patients treated with cangrelor more frequently experienced ≥1 TIMI flow grade improvement during PCI (92.9% vs. 81.2%, P = 0.02). CONCLUSION: Cangrelor treatment was associated with similar bleeding risk and significantly better TIMI flow improvement compared with oral P2Y12 inhibitors in CS patients undergoing PCI. The use of cangrelor in CS offers a potentially safe and effective antiplatelet option and should be evaluated in randomized trials.


Assuntos
Síndrome Coronariana Aguda/terapia , Monofosfato de Adenosina/análogos & derivados , Intervenção Coronária Percutânea , Antagonistas do Receptor Purinérgico P2Y/uso terapêutico , Choque Cardiogênico/terapia , Monofosfato de Adenosina/administração & dosagem , Monofosfato de Adenosina/uso terapêutico , Administração Oral , Idoso , Terapia Combinada , Feminino , Humanos , Masculino , Análise por Pareamento , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Antagonistas do Receptor Purinérgico P2Y/administração & dosagem , Estudos Retrospectivos