Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cardiovasc Revasc Med ; 40S: 148-153, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34412989

RESUMO

INTRODUCTION: The Perceval Valve has been increasingly used in Surgical Aortic Valve Replacement (SAVR) recently due to ease of implantation. However, we have seen some cases of relatively early haemodynamic failure of the Perceval valve and these patients may then present for valve-in-valve transcatheter aortic valve implantation (ViV-TAVI). Experience of ViV-TAVI in the Perceval valve is limited. METHODS: We report our experience of VIV-TAVI in four cases of early-failing Perceval valves, two with stenosis and two with regurgitation. We also review the literature with regard to ViV-TAVI for this indication. RESULTS: Four patients aged between 66 and 78 years presented with Perceval valve dysfunction an average of 4.6 years following SAVR. All cases underwent Heart Team discussion and a ViV-TAVI procedure was planned thereafter. Strategies to ensure crossing through the centre of the valve and not outside any portion of the frame were found to be essential. Three patients had self-expanding valves implanted and one had a balloon-expandable prosthesis. The average aortic valve area (AVA) improved from 0.8 cm2 pre-procedure to 1.5 cm2 post-procedure*. The mean gradient (MG) improved from 35.5 mmHg (range 19.7-53 mmHg) pre-procedure to 14.8 mmHg (range 7-30 mmHg) post-procedure. In one patient a MG of 30 mmHg persisted following valve deployment. There were no significant peri-procedural complications. CONCLUSIONS: ViV-TAVI is a useful option for failed Perceval prostheses and appears safe and effective in this small series. Crossing inside the whole frame of the Perceval valve is essential.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desenho de Prótese , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Future Healthc J ; 7(3): e39-e40, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33094251

RESUMO

The COVID-19 pandemic has significantly altered working practices within hospitals. This includes surgical theatres and cardiac catheter laboratories. Here we describe how we have harnessed the use of video technology to improve the running of the cardiac catheter lab in our institution, reducing the exposure of staff members to COVID-19, reducing the need for personal protective equipment (PPE) and maintaining and enhancing educational and teaching opportunities for trainees.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...