1.
Opt Express ; 28(9): 13310-13322, 2020 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-32403809

RESUMO

We present a small power meter that detects the radiation pressure of an incident high-power laser. Given its small package and non-destructive interaction with the laser, this power meter is well suited to realizing a robust real-time, high-accuracy power measurement in laser-based manufacturing environments. The incident laser power is determined through interferometric measurement of displacement of a 20 mm diameter high reflectivity mirror, mounted at the center of a dual element spiral flexure. This device can measure laser power from 25 W to 400 W with a 260 m W/H z noise floor and ≤ 3.2% expanded uncertainty. We validate our device against a calibrated thermopile with simultaneous measurements of an unpolarized 1070 nm laser and report good agreement between the two systems. Finally, by referencing to an identical mechanical spring that does not see the incident laser, we suppress vibration noise in the power measurement by 14.8 dB over a 600 Hz measured bandwidth. This is an improvement over other radiation pressure based power meters that have previously been demonstrated.

2.
J Laser Appl ; 302018.
Artigo em Inglês | MEDLINE | ID: mdl-30983843

RESUMO

Ultrafast lasers have become increasingly important as research tools in laboratories and commercial enterprises suggesting laser safety, personal protection and awareness become ever more important. Laser safety eyewear are typically rated by their optical densities (OD) over various spectral ranges, but these measurements are usually made using low power, large beam size, and continuous beam conditions. These measurement scenarios are vastly different than the high power, small beam size, and pulsed laser beam conditions where ultrafast lasers have extremely high peak powers and broad spectra due to the short pulse durations. Many solid-state lasers are also tunable over a broad wavelength range, further complicating the selection of adequate laser safety eyewear. Eighteen laser eyewear filter samples were tested under real-world conditions using a Ti:Sapphire regenerative amplifier with output pulses centered at 800 nm running from 2 Hz to 1 KHz repetition rate. The typical maximum peak laser irrandiance employed was ca. 3 TW/cm2 (800 nm wavelength, 450 uJ/pulse with 80 fs FWHM pulse duration) or less when damage occurred, depending on the sample. While many samples maintained their integrity under these test conditions, many plastic samples showed signs of failure which reduced their OD, in some cases transmitting 4 to 5 orders of magnitude higher than expected. In general, glass filters performed significantly better than plastic filters, exhibiting less physical damage to the substrate and less absorber degradation.

3.
Appl Opt ; 56(34): 9596-9600, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-29216078

RESUMO

We have demonstrated the calibration of a thermal power meter against a radiation pressure power meter in the range of 20 kW in a manufacturing test environment. The results were compared to a traditional calorimeter-based laboratory calibration undertaken at the National Institute of Standards and Technology. The results are reported, and the effects of nonideal conditions typical of measurements in low-stability environments are discussed.

4.
J Laser Appl ; 29(4)2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29353984

RESUMO

Ultrafast laser systems are becoming more widespread throughout the research and industrial communities yet eye protection for these high power, bright pulsed sources still require scrupulous characterization and testing before use. Femtosecond lasers, with pulses naturally possessing broad-bandwidth and high average power with variable repetition rate, can exhibit spectral side-bands and subtly changing center wavelengths, which may unknowingly affect eyewear safety protection. Pulse spectral characterization and power diagnostics are presented for a 80 MHz, Ti+3:Sapphire, ≈ 800 nm, ≈40 femtosecond oscillator system. Power and spectral transmission for 22 test samples are measured to determine whether they fall within manufacturer specifications.

5.
Opt Lett ; 38(20): 4248-51, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-24321971

RESUMO

We demonstrate a paradigm in absolute laser radiometry where a laser beam's power can be measured from its radiation pressure. Using an off-the-shelf high-accuracy mass scale, a 530 W Yb-doped fiber laser, and a 92 kW CO(2) laser, we present preliminary results of absolute optical power measurements with inaccuracies of better than 7% to 13%. We find negligible contribution from radiometric (thermal) forces. We also identify this scale's dynamic-force noise floor for a 0.1 Hz modulation frequency as 4 µN/Hz(1/2) or, as optical power sensitivity, 600 W/Hz(1/2).

6.
J Res Natl Inst Stand Technol ; 114(5): 287-91, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-27504228

RESUMO

This paper discusses a procedure for measuring the absolute spectral responsivity of optical-fiber power meters and computation of the calibration uncertainty. The procedure reconciles measurement results associated with a monochromator-based measurement system with those obtained with laser sources coupled with optical fiber. Relative expanded uncertainties based on the methods from the Guide to the Expression of Uncertainty in Measurement and from Supplement 1 to the "Guide to the Expression of Uncertainty in Measurement"-Propagation of Distributions using a Monte Carlo Method are derived and compared. An example is used to illustrate the procedures and calculation of uncertainties.