Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
J Athl Train ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38835321

RESUMO

Athletic trainers are increasingly utilized in non-traditional settings, such as in law enforcement, where they can contribute to healthcare management, including concussion management of law enforcement officers (LEOs). Despite the prevalence of concussions among LEOs, there is a notable gap in concussion management guidelines for this population. LEOs may lack the education and resources necessary for concussion recognition and proper management. Drawing on advancements in concussion management in athletes and military personnel, here we present a comprehensive framework for concussion management in LEOs encompassing concussion education, a graduated return to duty (RTD) protocol, and considerations for implementation and documentation specific to law enforcement. We also present several barriers and facilitators to implementation. Due to job requirements, it is critical for law enforcement organizations and their medical providers to adopt a concussion management strategy. Without proper concussion management, LEOs may risk subsequent injury and/or suffer from prolonged recovery and adverse long-term outcomes.

2.
J Strength Cond Res ; 38(1): 30-37, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37815253

RESUMO

ABSTRACT: Merrigan, JJ, Strang, A, Eckerle, J, Mackowski, N, Hierholzer, K, Ray, NT, Smith, R, Hagen, JA, and Briggs, RA. Countermovement jump force-time curve analyses: reliability and comparability across force plate systems. J Strength Cond Res 38(1): 30-37, 2024-Considering the growing prevalence of commercial force plates providing automated force-time analyses, understanding levels of agreement across force plate systems is warranted. Countermovement jump (CMJ) metrics across Vald ForceDecks (FD), Hawkin Dynamics (HD), and Sparta Science (SS) force plate systems were compared. Twenty-two subjects completed CMJ testing (∼128 comparisons) on each force plate system separately with rest between jumps. Baseline testing occurred 3 times and demonstrated poor test-retest reliability for modified reactive strength index (mRSI) and rate of force development (RFD). ForceDecks and HD comparisons yielded acceptable agreement for concentric/propulsive relative force and net impulse, jump height, eccentric/braking RFD, and mRSI, but systematic and proportionate bias existed for RFD. Sparta Science jump height and reactive strength index (RSI) demonstrated systematic overestimations compared with HD and FD, but jump height had acceptable agreement according to concordance correlation coefficients (CCC = 0.92-0.95). Agreement between SS load (eccentric RFD) and HD braking RFD was acceptable (CCC = 0.91), whereas agreement between SS load and FD deceleration RFD was considered acceptable (CCC = 0.81-0.87) but demonstrated systematic and proportionate bias. ForceDecks (CCC = 0.89) and HD (CCC = 0.85) average relative concentric/propulsive force yielded acceptable agreement with SS explode (average relative concentric force), but SS explode demonstrated systematically lower values than FD and HD. Sparta Science drive (concentric impulse) yielded acceptable agreement with HD relative propulsive impulse (CCC = 0.85), but not FD concentric impulse. Human performance practitioners need to be aware of inconsistencies among testing procedures and analyses across force plate systems, such as differences in metric definitions and units of measurement, before making comparisons across systems.


Assuntos
Força Muscular , Humanos , Reprodutibilidade dos Testes
3.
Ann Biomed Eng ; 2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37847420

RESUMO

Law enforcement cadets (LECs) complete weeks of subject control technique training. Similar sport-related combat training has been shown to expose participants to head acceleration events (HAEs) that have potential to result in short- and long-term impairments. The purpose of this study was to describe the number and magnitude of HAEs in LECs throughout their training. 37 LECs (7 females; age = 30.6 ± 8.8 years; BMI = 30.0 ± 6.0) were recruited from a law enforcement organization. Participants wore instrumented mouthguards, which recorded all HAEs exceeding a resultant 5 g threshold for training sessions with the potential for HAEs. Participants completed three defensive tactics (DT) training sessions, a DT skill assessment (DTA), and three boxing sessions. Outcome measures included the number of HAEs, peak linear acceleration (PLA), and peak rotational velocity (PRV). There were 2758 true-positive HAEs recorded across the duration of the study. Boxing sessions accounted for 63.7% of all true-positive HAEs, while DT accounted for 31.4% and DTA accounted for 4.9%. Boxing sessions resulted in a higher number of HAEs per session (F2,28 = 48.588, p < 0.001, ηp2 = 0.776), and higher median PLA (F2,28 = 8.609, p = 0.001, ηp2 = 0.381) and median PRV (F2,28 = 11.297, p < 0.001, ηp2 = 0.447) than DT and DTA. The LECs experience a high number of HAEs, particularly during boxing sessions. Although this training is necessary for job duties, HAE monitoring may lead to modifications in training structure to improve participant safety and enhance recovery.

4.
Glob Adv Integr Med Health ; 12: 27536130231187636, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37434793

RESUMO

Background: Mindfulness in Motion (MIM) is a workplace resilience-building intervention that has shown reductions in perceived stress and burnout, as well as increased resilience and work engagement in health care workers. Objective: To evaluate effects of MIM delivered in a synchronous virtual format on self-reported respiratory rates (RR), as well as perceived stress and resiliency of health care workers. Methods: Breath counts were self-reported by 275 participants before and after 8 weekly MIM sessions. MIM was delivered virtually in a group format as a structured, evidence-based workplace intervention including a variety of mindfulness, relaxation, and resilience-building techniques. Participants counted their breaths for 30 seconds, which was then multiplied by 2 to report RR. Additionally, participants completed Perceived Stress Scale and Connor-Davidson Resiliency Scale. Results: According to mixed effect analyses there were main effects of MIM Session (P < .001) and Weeks (P < .001), but no Session by Week interaction (P = .489) on RR. On average, RR prior to MIM sessions were reduced from 13.24 bpm (95% CI = 12.94, 13.55 bpm) to 9.69 bpm (95% CI = 9.39, 9.99 bpm). When comparing average Pre-MIM and Post-MIM RR throughout the MIM intervention, Week-2 (mean = 12.34; 95% CI = 11.89, 12.79 bpm) was not significantly different than Week-1 (mean = 12.78; 95% CI = 12.34, 13.23 bpm), but Week-3 through Week-8 demonstrated significantly lower average Pre-MIM and Post-MIM RR compared to Week-1 (average weekly difference range: 1.36 to 2.48 bpm, P < .05). Perceived stress was reduced from Week-1 (17.52 ± 6.25) to after Week-8 (13.52 ± 6.04; P < .001), while perceived resiliency was increased from Week-1 (11.30 ± 5.14) to after Week-8 (19.29 ± 2.58); P < .001). Conclusion: Thus far, completion of MIM sessions has shown acute and long-term effects on self-reported RR, but more research is required to determine the extent of improved parasympathetic (relaxed) states. Collectively, this work has shown value for mind-body stress mitigation and resiliency-building in high stress acute health care environments.

5.
Lasers Med Sci ; 38(1): 111, 2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37099210

RESUMO

This study aims to examine the effects of acute whole-body photobiomodulation (wbPBM), applied pre-exercise, on bouts of anaerobic cycling (Wingate) performances. Forty-eight healthy, active males and females participated in this single-blind, randomized, crossover study. Participants visited the laboratory three times to complete repeat (4 ×) Wingate testing, with one week between each visit. All participants completed baseline testing during their first visit and randomly received either the wbPBM or placebo condition before testing on the second visit, followed by the opposite condition on the third visit. There were no significant condition × time interactions for any variable (peak power, average power, power decrement, lactate, heart rate, ratings of perceived exertion, heart rate variability (HRV), root-mean square of differences between R-R intervals (rMSSD), power in the high-frequency range (HF) average, power in the low-frequency range (LF) average, total power, LF/HF, or power in the very-low-frequency range average). A main condition effect was only noted for heart rate, where peak heart rate was significantly higher for wbPBM (145, 141-148 bpm) than placebo (143, 139-146 bpm; p = 0.006) and baseline testing (143, 140-146; p = 0.049) throughout the entire testing session (i.e., collapsed across all timepoints). Furthermore, HRV (rMSSD) the following morning after testing was significantly higher for the wbPBM session compared to placebo (p = 0.043). There were no differences in perceived recovery (p = 0.713) or stress (p = 0.978) scores between wbPBM and placebo. Implementing 20 min of wbPBM immediately prior to maximal bouts of anaerobic cycling did not improve performance (i.e., power output) or physiological responses (e.g., lactate). However, wbPBM elicited the ability to work at a higher heart rate throughout testing and seemed to enhance recovery through improved HRV the following morning.


Assuntos
Ciclismo , Ácido Láctico , Masculino , Feminino , Humanos , Estudos Cross-Over , Anaerobiose , Método Simples-Cego , Ciclismo/fisiologia , Frequência Cardíaca/fisiologia
6.
J Strength Cond Res ; 36(9): 2387-2402, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35916879

RESUMO

ABSTRACT: Merrigan, JJ, Stone, JD, Galster, SM, and Hagen, JA. Analyzing force-time curves: Comparison of commercially available automated software and custom MATLAB analyses. J Strength Cond Res 36(9): 2387-2402, 2022-With the growing prevalence of commercial force plate solutions providing automated force-time curve analysis, it is critical to understand the level of agreement across techniques. Thus, this study directly compared commercial and custom software analyses across force-time curves. Twenty-four male and female subjects completed 6 trials of countermovement, squat, and drop jumps, and isometric mid-thigh pulls on the same force plate. Vertical ground reaction forces were analyzed by automated software from Vald Performance, Hawkin Dynamics, and custom MATLAB scripts. Trials were visually assessed to verify proper landmark identifications. Systematic and proportional bias among analyses were compared via least products regressions, Bland-Altman plots, and percent error. Hawkin Dynamics had subtle differences in analysis procedures and demonstrated low percent errors across all tests (<3% error), despite demonstrating systematic and proportional bias for several metrics. ForceDecks demonstrated larger percent differences and greater biases for several metrics. These errors likely result from different identification of movement initiation, system weight, and integration techniques, which causes error to subsequent landmark identifications (e.g., braking/propulsive phases) and respective force-time metrics. Many metrics were in agreement between devices, such as isometric mid-thigh pull peak force consistently within 1 N across analyses, but some metrics are difficult and incomparable across software analyses (i.e., rate of force development). Overall, many metrics were in agreement across each commercial software and custom MATLAB analyses after visually confirming landmarks. However, because of inconsistencies, it is important to only compare metrics that are in agreement across software analyses when absolutely necessary.


Assuntos
Força Muscular , Coxa da Perna , Feminino , Humanos , Masculino , Movimento , Postura , Software
7.
Front Sports Act Living ; 4: 795897, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35252854

RESUMO

The primary purpose was to simplify external load data obtained during Division-I (DI) basketball competitions via principal component analysis (PCA). A secondary purpose was to determine if the PCA results were sensitive to load demands of different positional groups (POS). Data comprised 229 observations obtained from 10 men's basketball athletes participating in NCAA DI competitions. Each athlete donned an inertial measurement unit that was affixed to the same location on their shorts prior to competition. The PCA revealed two factors that possessed eigenvalues >1.0 and explained 81.42% of the total variance. The first factor comprised total decelerations (totDEC, 0.94), average speed (avgSPD, 0.90), total accelerations (totACC, 0.85), total mechanical load (totMECH, 0.84), and total jump load (totJUMP, 0.78). Maximum speed (maxSPD, 0.94) was the lone contributor to the second factor. Based on the PCA, external load variables were included in a multinomial logistic regression that predicted POS (Overall model, p < 0.0001; AUCcenters = 0.93, AUCguards = 0.88, AUCforwards = 0.80), but only maxSPD, totDEC, totJUMP, and totMECH were significant contributors to the model's success (p < 0.0001 for each). Even with the high significance, the model still had some issues differentiating between guards and forwards, as in-game demands often overlap between the two positions. Nevertheless, the PCA was effective at simplifying a large external load dataset collected on NCAA DI men's basketball athletes. These data revealed that maxSPD, totDEC, totJUMP, and totMECH were the most sensitive to positional differences during competitions. To best characterize competition demands, such variables may be used to individualize training and recovery regimens most effectively.

8.
J Strength Cond Res ; 36(2): 411-419, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34798642

RESUMO

ABSTRACT: Merrigan, JJ, Rentz, LE, Hornsby, WG, Wagle, JP, Stone, JD, Smith, HT, Galster, SM, Joseph, M, and Hagen, JA. Comparisons of countermovement jump force-time characteristics among NCAA Division I American football athletes: use of principal component analysis. J Strength Cond Res 36(2): 411-419, 2022-This study aimed to reduce the dimensionality of countermovement jump (CMJ) force-time characteristics and evaluate differences among positional groups (skills, hybrid, linemen, and specialists) within National Collegiate Athletic Association (NCAA) division I American football. Eighty-two football athletes performed 2 maximal effort, no arm-swing, CMJs on force plates. The average absolute and relative (e.g., power/body mass) metrics were analyzed using analysis of variance and principal component analysis procedures (p < 0.05). Linemen had the heaviest body mass and produced greater absolute forces than hybrid and skills but had lower propulsive abilities demonstrated by longer propulsive phase durations and greater eccentric to concentric mean force ratios. Skills and hybrid produced the most relative concentric and eccentric forces and power, as well as modified reactive strength indexes (RSIMOD). Skills (46.7 ± 4.6 cm) achieved the highest jump height compared with hybrid (42.8 ± 5.5 cm), specialists (38.7 ± 4.0 cm), and linemen (34.1 ± 5.3 cm). Four principal components explained 89.5% of the variance in force-time metrics. Dimensions were described as the (a) explosive transferability to concentric power (RSIMOD, concentric power, and eccentric to concentric forces) (b) powerful eccentric loading (eccentric power and velocity), (c) countermovement strategy (depth and duration), and (d) jump height and power. The many positional differences in CMJ force-time characteristics may inform strength and conditioning program designs tailored to each position and identify important explanatory metrics to routinely monitor by position. The overwhelming number of force-time metrics to select from may be reduced using principal component analysis methods, although practitioners should still consider the various metric's applicability and reliability.


Assuntos
Desempenho Atlético , Futebol Americano , Atletas , Humanos , Força Muscular , Análise de Componente Principal , Reprodutibilidade dos Testes
9.
J Strength Cond Res ; 36(1): 277-283, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34941613

RESUMO

ABSTRACT: Merrigan, JJ, Stone, JD, Wagle, JP, Hornsby, WG, Ramadan, J, Joseph, M, and Hagen, JA. Using random forest regression to determine influential force-time metrics for countermovement jump height: a technical report. J Strength Cond Res 36(1): 277-283, 2022-The purpose of this study was to indicate the most influential force-time metrics on countermovement jump (CMJ) height using multiple statistical procedures. Eighty-two National Collegiate Athletic Association Division I American football players performed 2 maximal-effort, no arm-swing, CMJs on force plates. The average absolute and relative (i.e., power/body mass) metrics were included as predictor variables, whereas jump height was the dependent variable within regression models (p < 0.05). Best subsets regression (8 metrics, R2 = 0.95) included less metrics compared with stepwise regression (18 metrics, R2 = 0.96), while explaining similar overall variance in jump height (p = 0.083). Random forest regression (RFR) models included 8 metrics, explained ∼93% of jump height variance, and were not significantly different than best subsets regression models (p > 0.05). Players achieved higher CMJs by attaining a deeper, faster, and more forceful countermovement with lower eccentric-to-concentric force ratios. An additional RFR was conducted on metrics scaled to body mass and revealed relative mean and peak concentric power to be the most influential. For exploratory purposes, additional RFR were run for each positional group and suggested that the most influential variables may differ across positions. Thus, developing power output capabilities and providing coaching to improve technique during the countermovement may maximize jump height capabilities. Scientists and practitioners may use best subsets or RFR analyses to help identify which force-time metrics are of interest to reduce the selectable number of multicollinear force-time metrics to monitor. These results may inform their training programs to maximize individual performance capabilities.


Assuntos
Desempenho Atlético , Futebol Americano , Tutoria , Benchmarking , Estatura , Humanos , Força Muscular
10.
Artigo em Inglês | MEDLINE | ID: mdl-34360435

RESUMO

Human performance optimization of tactical personnel requires accurate, meticulous, and effective monitoring of biological adaptations and systemic recovery. Due to an increased understanding of its importance and the commercial availability of assessment tools, the use of heart rate variability (HRV) to address this need is becoming more common in the tactical community. Measuring HRV is a non-invasive, practical method for objectively assessing a performer's readiness, workload, and recovery status; when combined with additional data sources and practitioner input, it provides an affordable and scalable solution for gaining actionable information to support the facilitation and maintenance of operational performance. This narrative review discusses the non-clinical use of HRV for assessing, monitoring, and interpreting autonomic nervous system resource availability, modulation, effectiveness, and efficiency in tactical populations. Broadly, HRV metrics represent a complex series of interactions resulting from internal and external stimuli; therefore, a general overview of HRV applications in tactical personnel is discussed, including the influence of occupational specific demands, interactions between cognitive and physical domains, and recommendations on implementing HRV for training and recovery insights into critical health and performance outcomes.


Assuntos
Sistema Nervoso Autônomo , Carga de Trabalho , Frequência Cardíaca , Humanos , Monitorização Fisiológica
11.
Cureus ; 13(5): e14838, 2021 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-34123609

RESUMO

A growing number of studies utilizing wearable technologies are examining the influence of the autonomic nervous system (ANS) on intense training, recovery, and injury risk. Exercise biometric (EB) data were collected on collegiate, female soccer players during a preseason camp. One player sustained an anterior cruciate ligament (ACL) injury. Baseline anthropometric and EB data were compared to non-injured, position-matched teammates. All players had similar baseline testing. The injured athlete had a higher body mass index (BMI) and slower vision reaction time (RT). On the day of her injury (DOI), relative percentage heart rate recovery (tHRR) between intense training sets was calculated. Relative percentage tHRR was much lower for the injured athlete, indicating reduced recovery between training sets immediately prior to the injury. Also on DOI, the injured athlete had a lower glomerular filtration rate (GFR). In addition to BMI and RT differences, the lower relative percentage tHRR and GFR on the DOI observed for the injured athlete may reflect an imbalanced ANS recovery, and potentially to risk factors leading to her ACL injury.

12.
Dev Biol ; 475: 10-20, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33662357

RESUMO

microRNAs (miRNAs) are ~21-22 nucleotide (nt) RNAs that mediate broad post-transcriptional regulatory networks. However, genetic analyses have shown that the phenotypic consequences of deleting individual miRNAs are generally far less overt compared to their misexpression. This suggests that miRNA deregulation may have broader phenotypic impacts during disease situations. We explored this concept in the Drosophila eye, by screening for miRNAs whose misexpression could modify the activity of pro-apoptotic factors. Via unbiased and comprehensive in vivo phenotypic assays, we identify an unexpectedly large set of miRNA hits that can suppress the action of pro-apoptotic genes hid and grim. We utilize secondary assays to validate that a subset of these miRNAs can inhibit irradiation-induced cell death. Since cancer cells might seek to evade apoptosis pathways, we modeled this situation by asking whether activation of anti-apoptotic miRNAs could serve as "second hits". Indeed, while clones of the lethal giant larvae (lgl) tumor suppressor are normally eliminated during larval development, we find that diverse anti-apoptotic miRNAs mediate the survival of lgl mutant clones in third instar larvae. Notably, while certain anti-apoptotic miRNAs can target apoptotic factors, most of our screen hits lack obvious targets in the core apoptosis machinery. These data highlight how a genetic approach can reveal distinct and powerful activities of miRNAs in vivo, including unexpected functional synergies during disease or cancer-relevant settings.


Assuntos
Apoptose/genética , MicroRNAs/genética , Animais , Apoptose/fisiologia , Morte Celular/genética , Proteínas de Drosophila/genética , Proteínas de Drosophila/metabolismo , Drosophila melanogaster/metabolismo , Olho/metabolismo , Proteínas do Olho/genética , Proteínas do Olho/metabolismo , Expressão Gênica/genética , Perfilação da Expressão Gênica/métodos , Regulação da Expressão Gênica/genética , Regulação da Expressão Gênica/fisiologia , Redes Reguladoras de Genes/genética , MicroRNAs/fisiologia , Neuropeptídeos/genética , Neuropeptídeos/metabolismo , Fenótipo , Proteínas Supressoras de Tumor/genética , Proteínas Supressoras de Tumor/metabolismo
13.
Front Sports Act Living ; 3: 585870, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33733234

RESUMO

Commercial off-the shelf (COTS) wearable devices continue development at unprecedented rates. An unfortunate consequence of their rapid commercialization is the lack of independent, third-party accuracy verification for reported physiological metrics of interest, such as heart rate (HR) and heart rate variability (HRV). To address these shortcomings, the present study examined the accuracy of seven COTS devices in assessing resting-state HR and root mean square of successive differences (rMSSD). Five healthy young adults generated 148 total trials, each of which compared COTS devices against a validation standard, multi-lead electrocardiogram (mECG). All devices accurately reported mean HR, according to absolute percent error summary statistics, although the highest mean absolute percent error (MAPE) was observed for CameraHRV (17.26%). The next highest MAPE for HR was nearly 15% less (HRV4Training, 2.34%). When measuring rMSSD, MAPE was again the highest for CameraHRV [112.36%, concordance correlation coefficient (CCC): 0.04], while the lowest MAPEs observed were from HRV4Training (4.10%; CCC: 0.98) and OURA (6.84%; CCC: 0.91). Our findings support extant literature that exposes varying degrees of veracity among COTS devices. To thoroughly address questionable claims from manufacturers, elucidate the accuracy of data parameters, and maximize the real-world applicative value of emerging devices, future research must continually evaluate COTS devices.

14.
J Funct Morphol Kinesiol ; 6(1)2021 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-33462166

RESUMO

The purpose of this longitudinal, descriptive study was to observe changes in maximal strength measured via isometric clean grip mid-thigh pull and home runs (total and home runs per game) across three years of training and three competitive seasons for four National Collegiate Athletic Association (NCAA) Division 1 baseball players. A one-way repeated measures analysis of variance (ANOVA) was performed, revealing significant univariate effects of time for peak force (PF) (p = 0.003) and peak force allometrically scaled (PFa) (p = 0.002). Increases in PF were noted from season 1 to season 2 (p = 0.031) and season 3 (p = 0.004), but season 2 was not significantly different than season 3 (p = 0.232). Additionally, increases in PFa were noted from season 1 to season 2 (p = 0.010) and season 3 (p < 0.001), but season 2 was not significantly different than season 3 (p = 0.052). Home runs per game rose from the 2009 (0.32) to 2010 season (1.35) and dropped during the 2011 season (1.07). A unique aspect of the study involves 2010 being the season in which ball-bat coefficient of restitution (BBCOR) bats were introduced to the NCAA competition.

15.
Artigo em Inglês | MEDLINE | ID: mdl-33297554

RESUMO

A necessarily high standard for physical readiness in tactical environments is often accompanied by high incidences of injury due to overaccumulations of neuromuscular fatigue (NMF). To account for instances of overtraining stimulated by NMF, close monitoring of neuromuscular performance is warranted. Previously validated tests, such as the countermovement jump, are useful means for monitoring performance adaptations, resiliency to fatigue, and risk for injury. Performing such tests on force plates provides an understanding of the movement strategy used to obtain the resulting outcome (e.g., jump height). Further, force plates afford numerous objective tests that are valid and reliable for monitoring upper and lower extremity muscular strength and power (thus sensitive to NMF) with less fatiguing and safer methods than traditional one-repetition maximum assessments. Force plates provide numerous software and testing application options that can be applied to military's training but, to be effective, requires the practitioners to have sufficient knowledge of their functions. Therefore, this review aims to explain the functions of force plate testing as well as current best practices for utilizing force plates in military settings and disseminate protocols for valid and reliable testing to collect key variables that translate to physical performance capacities.


Assuntos
Militares , Força Muscular , Teste de Esforço , Humanos , Extremidade Inferior , Movimento
16.
Nat Sci Sleep ; 12: 821-842, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33149712

RESUMO

PURPOSE: The commercial market is saturated with technologies that claim to collect proficient, free-living sleep measurements despite a severe lack of independent third-party evaluations. Therefore, the present study evaluated the accuracy of various commercial sleep technologies during in-home sleeping conditions. MATERIALS AND METHODS: Data collection spanned 98 separate nights of ad libitum sleep from five healthy adults. Prior to bedtime, participants utilized nine popular sleep devices while concurrently wearing a previously validated electroencephalography (EEG)-based device. Data collected from the commercial devices were extracted for later comparison against EEG to determine degrees of accuracy. Sleep and wake summary outcomes as well as sleep staging metrics were evaluated, where available, for each device. RESULTS: Total sleep time (TST), total wake time (TWT), and sleep efficiency (SE) were measured with greater accuracy (lower percent errors) and limited bias by Fitbit Ionic [mean absolute percent error, bias (95% confidence interval); TST: 9.90%, 0.25 (-0.11, 0.61); TWT: 25.64%, -0.17 (-0.28, -0.06); SE: 3.49%, 0.65 (-0.82, 2.12)] and Oura smart ring [TST: 7.39%, 0.19 (0.04, 0.35); TWT: 36.29%, -0.18 (-0.31, -0.04); SE: 5.42%, 1.66 (0.17, 3.15)], whereas all other devices demonstrated a propensity to over or underestimate at least one if not all of the aforementioned sleep metrics. No commercial sleep technology appeared to accurately quantify sleep stages. CONCLUSION: Generally speaking, commercial sleep technologies displayed lower error and bias values when quantifying sleep/wake states as compared to sleep staging durations. Still, these findings revealed that there is a remarkably high degree of variability in the accuracy of commercial sleep technologies, which further emphasizes that continuous evaluations of newly developed sleep technologies are vital. End-users may then be able to determine more accurately which sleep device is most suited for their desired application(s).

17.
J Funct Morphol Kinesiol ; 5(3)2020 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-33467262

RESUMO

The purpose of this study was to assess the validity of utilizing heart rate to derive an estimate of core body temperature in American Football athletes. This was evaluated by combining commercially available Zephyr Bioharness devices, which includes an embedded estimated core temperature (ECT) algorithm, and an ingestible radio frequency core temperature pill during the highest heat injury risk timepoint of the season, summer training camp. Results showed a concordance of 0.643 and 78% of all data points fell within +/-1.0 °F. When the athletes were split into Upper (>/=6.0%) and Lower (<6.0%) body composition groups, there was a statistical improvement in accuracy with the Upper Body Fat% reaching 0.834 concordance and 93% of all values falling within +/-1.0 °F of the Gold Standard. Results suggest that heart rate derived core temperature assessments are a viable tool for heat stress monitoring in American football, but more work is required to improve on accuracy based on body composition.

18.
J Funct Morphol Kinesiol ; 5(3)2020 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-33467284

RESUMO

The ongoing Coronavirus 2 (COVID-19) pandemic abruptly halted athletic competition and standard training practices, consequently generating great confusion surrounding when and how to safely reintroduce sports. Therefore, tangible solutions disseminated to performance staff, coaches, and athletes are warranted to ensure optimal levels of health and physical performance for all personnel during both the current social distancing standards as well as the impending return of competition despite continued risks. In this commentary, we offer strategies for utilizing technology and data tools as components of longitudinal COVID-19 surveillance based on ongoing research efforts as well as current guidance from governing bodies, while also serving the performance needs of the athletes and staff. Recommended data sources include digital symptom and well-being surveys, standardized and routine physical performance testing, sleep and sleep physiology monitoring, cognitive applications, and temperature. This system is flexible to numerous commercially available products and is designed for easy implementation that permits instant feedback provided directly to the athlete as well as their support staff for early intervention, ultimately mitigating COVID-19 risks. We will discuss multiple options, including examples of data, data visualizations and recommendations for data interpretation and communication.

19.
Sports (Basel) ; 9(1)2020 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-33396304

RESUMO

The purpose of this study was to evaluate intrasession reliability of countermovement jump (CMJ) and isometric mid-thigh pull (IMTP) force-time characteristics, as well as relationships between CMJ and IMTP metrics. Division I sport and club athletes (n = 112) completed two maximal effort CMJ and IMTP trials, in that order, on force plates. Relative and absolute reliability were assessed using intraclass correlation coefficients (ICCs) > 0.80 and coefficients of variation (CVs) < 10%. Intrasession reliability was acceptable for the majority of the CMJ force-time metrics except for concentric rate of force development (RFD), eccentric impulse and RFD, and lower limb stiffness. The IMTP's time to peak force, instantaneous force at 150 ms, instantaneous net force, and RFD measures were not reliable. Statistically significant weak to moderate relationships (r = 0.20-0.46) existed between allometrically scaled CMJ and IMTP metrics, with the exception of CMJ eccentric mean power not being related with IMTP performances. A majority of CMJ and IMTP metrics met acceptable reliability standards, except RFD measures which should be used with caution. Provided CMJs and IMTPs are indicative of distinct physical fitness capabilities, it is suggested to monitor athlete performance in both tests via changes in those variables that demonstrate the greatest degree of reliability.

20.
ACS Appl Mater Interfaces ; 11(15): 13927-13934, 2019 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-30884221

RESUMO

Transmission electron microscopy (TEM) is being pushed to new capabilities which enable studies on systems that were previously out of reach. Among recent innovations, TEM through liquid cells (LC-TEM) enables in operando observation of biological phenomena. This work applies LC-TEM to the study of biological components as they interact on an abiotic surface. Specifically, analytes or target molecules like neuropeptide Y (NPY) are observed in operando on functional graphene field-effect transistor (GFET) biosensors. Biological recognition elements (BREs) identified using biopanning with affinity to NPY are used to functionalize graphene to obtain selectivity. On working devices capable of achieving picomolar responsivity to neuropeptide Y, LC-TEM reveals translational motion, stochastic positional fluctuations due to constrained Brownian motion, and rotational dynamics of captured analyte. Coupling these observations with the electrical responses of the GFET biosensors in response to analyte capture and/or release will potentially enable new insights leading to more advanced and capable biosensor designs.


Assuntos
Técnicas Biossensoriais/métodos , Grafite/química , Neuropeptídeo Y/análise , Transistores Eletrônicos , Área Sob a Curva , Técnicas Biossensoriais/instrumentação , Microscopia Crioeletrônica , Humanos , Neuropeptídeo Y/química , Biblioteca de Peptídeos , Ligação Proteica , Curva ROC , Suor/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...