Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Heart J Open ; 4(3): oeae044, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38933428

RESUMO

Aims: Pulmonary vein isolation (PVI) represents the gold standard in the treatment of atrial fibrillation (AF) and the use of single-shot techniques, such as cryoballoon ablation (CBA) and pulsed field ablation (PFA) using a pentaspline catheter, has gained prominence. Recent studies hypothesize that PFA might be superior to CBA, although procedural efficacy and safety data are inconsistent. A meta-analysis was conducted to compare both energy sources for the treatment of AF. Methods and results: A structured systematic database search and meta-analysis were performed on studies investigating outcomes, periprocedural complications, and/or procedural parameters of AF patients treated by either CBA or PFA. Eleven studies reporting data from 3805 patients were included. Pulmonary vein isolation by PFA was associated with a significantly lower recurrence of atrial fibrillation/atrial tachycardia [odds ratio (OR) = 0.73, 95% confidence interval (CI) = 0.54-0.98, I2 = 20%] and fewer periprocedural complications (OR = 0.62, 95% CI = 0.40-0.96, I2 = 6%) compared to CBA. The lower complication rate following PFA was mainly driven by fewer phrenic nerve injuries (OR = 0.19, 95% CI = 0.08-0.43, I2 = 0%). However, there were more cases of cardiac tamponades after PFA (OR = 2.56, 95% CI = 1.01-6.49, I2 = 0%). Additionally, using PFA for PVI was associated with shorter total procedure times [mean difference (MD) = -9.68, 95% CI = -14.92 to -4.43 min, I2 = 92%] and lower radiation exposure (MD = -148.07, 95% CI = -276.50 to -19.64 µGy·mI2 = 7%). Conclusion: Our results suggest that PFA for PVI, compared to CBA, enables shorter procedure times with lower arrhythmia recurrence and a reduced risk of periprocedural complications. Randomized controlled trials need to confirm our findings.

2.
Front Digit Health ; 6: 1341475, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38510279

RESUMO

Introduction: Today, modern technology is used to diagnose and treat cardiovascular disease. These medical devices provide exact measures and raw data such as imaging data or biosignals. So far, the Broad Integration of These Health Data into Hospital Information Technology Structures-Especially in Germany-is Lacking, and if data integration takes place, only non-Evaluable Findings are Usually Integrated into the Hospital Information Technology Structures. A Comprehensive Integration of raw Data and Structured Medical Information has not yet Been Established. The aim of this project was to design and implement an interoperable database (cardio-vascular-information-system, CVIS) for the automated integration of al medical device data (parameters and raw data) in cardio-vascular medicine. Methods: The CVIS serves as a data integration and preparation system at the interface between the various devices and the hospital IT infrastructure. In our project, we were able to establish a database with integration of proprietary device interfaces, which could be integrated into the electronic health record (EHR) with various HL7 and web interfaces. Results: In the period between 1.7.2020 and 30.6.2022, the data integrated into this database were evaluated. During this time, 114,858 patients were automatically included in the database and medical data of 50,295 of them were entered. For technical examinations, more than 4.5 million readings (an average of 28.5 per examination) and 684,696 image data and raw signals (28,935 ECG files, 655,761 structured reports, 91,113 x-ray objects, 559,648 ultrasound objects in 54 different examination types, 5,000 endoscopy objects) were integrated into the database. Over 10.2 million bidirectional HL7 messages (approximately 14,000/day) were successfully processed. 98,458 documents were transferred to the central document management system, 55,154 materials (average 7.77 per order) were recorded and stored in the database, 21,196 diagnoses and 50,353 services/OPS were recorded and transferred. On average, 3.3 examinations per patient were recorded; in addition, there are an average of 13 laboratory examinations. Discussion: Fully automated data integration from medical devices including the raw data is feasible and already creates a comprehensive database for multimodal modern analysis approaches in a short time. This is the basis for national and international projects by extracting research data using FHIR.

3.
ACS Appl Mater Interfaces ; 16(5): 5613-5626, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38278772

RESUMO

In vivo, cells reside in a 3D porous and dynamic microenvironment. It provides biochemical and biophysical cues that regulate cell behavior in physiological and pathological processes. In the context of fundamental cell biology research, tissue engineering, and cell-based drug screening systems, a challenge is to develop relevant in vitro models that could integrate the dynamic properties of the cell microenvironment. Taking advantage of the promising high internal phase emulsion templating, we here designed a polyHIPE scaffold with a wide interconnected porosity and functionalized its internal 3D surface with a thin layer of electroactive conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) to turn it into a 4D electroresponsive scaffold. The resulting scaffold was cytocompatible with fibroblasts, supported cellular infiltration, and hosted cells, which display a 3D spreading morphology. It demonstrated robust actuation in ion- and protein-rich complex culture media, and its electroresponsiveness was not altered by fibroblast colonization. Thanks to customized electrochemical stimulation setups, the electromechanical response of the polyHIPE/PEDOT scaffolds was characterized in situ under a confocal microscope and showed 10% reversible volume variations. Finally, the setups were used to monitor in real time and in situ fibroblasts cultured into the polyHIPE/PEDOT scaffold during several cycles of electromechanical stimuli. Thus, we demonstrated the proof of concept of this tunable scaffold as a tool for future 4D cell culture and mechanobiology studies.


Assuntos
Polímeros , Estirenos , Alicerces Teciduais , Alicerces Teciduais/química , Porosidade , Polímeros/farmacologia , Polímeros/química , Técnicas de Cultura de Células , Engenharia Tecidual/métodos
4.
Artigo em Inglês | MEDLINE | ID: mdl-36674018

RESUMO

Increasing patient inflow into the emergency department makes it necessary to optimize triage management. The scope of this work was to determine simple factors that could detect fractures in patients without the need for specialized personnel. Between 2014 and 2015, 798 patients were admitted to an orthopedic emergency department and prospectively included in the study. The patients received a questionnaire before contacting the doctor. Objective and subjective data were evaluated to determine fracture risk for the upper and lower extremities. The highest risk for fractures in one region was the hip (73.21%; n = 56), followed by the wrist (60.32%; n = 63) and the femoral shaft (4 of 7, 57.14%; n = 7). The regions with the lowest risk were the knee (8.41%; n = 107), the ankle (18.29%; n = 164), and the forearm shaft (30.00%; n = 10). Age was a predictor for fracture: patients older than 59 years had a risk greater than 59.26%, and patients older than 90 years had a risk greater than 83.33%. The functional questions could exclude fractures. Three factors seem to be able to predict fracture risk: the injured region, the patient's age, and a functional question. They can be used for a probatory heuristic that needs to be proven in a prospective way.


Assuntos
Fraturas Ósseas , Ortopedia , Humanos , Pessoa de Meia-Idade , Fraturas Ósseas/epidemiologia , Probabilidade , Risco , Hospitalização
5.
Mamm Genome ; 34(2): 323-330, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36481846

RESUMO

BACKGROUND: The number of cardiologically relevant genetic findings will continue to increase. This is due to the use of high-throughput sequencing techniques and the critical role of incidental findings in cardiac disease genes. Telemedicine can be a useful diagnostic tool to monitor the heart rhythm of patients with inborn cardiac diseases. METHODS: Patients were screened once they had been referred to our outpatient department for rare cardiac diseases between January 2020 and May 2022. Those patients who underwent genetic testing and were consequently diagnosed with a genetic disorder were included in this study. Their medical records were evaluated regarding implanted cardiac electronic devices and findings in the telemedical monitoring. RESULTS: 304 patients were seen in our outpatient department for rare cardiac diseases in the mentioned period. In 100 cases, genetic testing was performed. 10 patients (10%) with an identified inborn cardiac disease were monitored via telemedicine until the end of May 2022. 4 patients were monitored by implantable loop recorders (ILR), 4 patients were monitored by Implantable Cardioverter Defibrillators (ICD), and 2 patients received both devices. Clinical relevant arrhythmias making medical intervention necessary were identified in 4 cases. In two cases, data interpretation was hampered by sinus tachycardia caused by physical exercise. DISCUSSION: Telemonitoring of the heart rhythm by medical devices is beneficial for patients with monogenic heart diseases. Especially, when the indication for an ICD is not clear, implantation of a telemonitored ILR can be a suitable choice. However, rhythm analysis can be challenging in young patients who are physically active.


Assuntos
Desfibriladores Implantáveis , Telemedicina , Humanos , Centros de Atenção Terciária , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/genética , Desfibriladores Implantáveis/efeitos adversos , Coração
6.
Biotechnol Adv ; 58: 107930, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35257786

RESUMO

3D bioprinting - the fabrication of geometrically complex 3D structures from biocompatible materials containing living cells using additive manufacturing technologies - is a rapidly developing research field with a broad range of potential applications in fundamental research, regenerative medicine and industry. Currently, research into 3D bioprinting is mostly focused on new therapeutic concepts for the treatment of injured or degenerative tissue by fabrication of functional tissue equivalents or disease models, utilizing mammalian cells. However, 3D bioprinting also has an enormous potential in biotechnology. Due to the defined spatial arrangement of biologically active (non-mammalian) cells in a biomaterial matrix, reaction compartments can be designed according to specific needs, or co-cultures of different cell types can be realized in a highly organized manner to exploit cell-cell interactions. Thus, 3D bioprinting technology can enable new biotechnological concepts, for example, by implementing perfusion systems while protecting shear sensitive cells or performing cascaded bioreactions. Here, we review the use of 3D bioprinting to manufacture defined 3D microenvironments for biotechnological applications using bacteria, fungi, microalgae, plant cells and co-cultures of different cell types. We discuss recent approaches to apply 3D bioprinting in biotechnological applications and - as it is a particular challenge - concepts for the real-time monitoring of the physiological state, growth and metabolic activity of the embedded cells in 3D bioprinted constructs. With these insights, we outline new applications of 3D bioprinting in biotechnology, engineered living materials and space research.


Assuntos
Bioimpressão , Animais , Materiais Biocompatíveis , Biotecnologia , Mamíferos , Impressão Tridimensional , Engenharia Tecidual , Alicerces Teciduais/química
7.
Eur J Trauma Emerg Surg ; 48(2): 1491-1498, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33000296

RESUMO

PURPOSE: Reduction and percutaneous screw fixation of sacroiliac joint disruptions and sacral fractures are surgical procedures for stabilizing the posterior pelvic ring. It is unknown, however, whether smaller irregularities or the inability to achieve an anatomic reduction of the joint and the posterior pelvic ring affects the functional outcome. Here, the long-term well-being of patients with and without anatomic reduction of the posterior pelvis after sacroiliac joint disruptions is described. METHODS: Between 2011 and 2017, 155 patients with pelvic injuries underwent surgical treatment. Of these, 39 patients with sacroiliac joint disruption were examined by radiological images and computer tomography (CT) diagnostics and classified according to Tile. The functional outcome of the different surgical treatments was assessed using the short form health survey-36 (SF-36) and the Majeed pelvic score. RESULTS: Complete data sets were available for 31 patients, including 14 Tile type C and 17 type B injuries. Of those, 26 patients received an anatomic reduction, 5 patients obtained a shift up to 10 mm (range 5-10 mm). The SF-36 survey showed that the anatomic reduction was significantly better in restoring the patient's well being (vitality, bodily pain, general mental health and emotional well-being). Patients without this treatment reported a decrease in their general health status. CONCLUSIONS: Anatomic reduction was achieved in over 80% of patients in this study. When comparing the long-term well-being of patients with and without anatomic reduction of the posterior pelvis after sacroiliac joint disruptions, the results suggest that anatomical restoration of the joint is beneficial for the patients.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/etiologia , Fraturas Ósseas/cirurgia , Humanos , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/lesões , Ossos Pélvicos/cirurgia , Articulação Sacroilíaca/diagnóstico por imagem , Articulação Sacroilíaca/lesões , Articulação Sacroilíaca/cirurgia , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 31(6): 1527-1535, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32173957

RESUMO

INTRODUCTION: Catecholaminergic polymorphic ventricular tachycardia (CPVT) is an inherited arrhythmia syndrome characterized by adrenergically stimulated ventricular tachycardia. The most common form of CPVT is due to autosomal dominant variants in the cardiac ryanodine-receptor gene (RYR2). However, trans-2,3-enoyl-CoA reductase-like (TECRL) was recently suggested to be a novel candidate gene for life-threatening inherited arrhythmias. Patients previously reported with pathogenic changes in TECRL showed a special mixed phenotype of CPVT and long-QT-syndrome (LQTS) termed CPVT type 3 (CPVT3), an autosomal recessive disorder. METHODS AND RESULTS: We implemented TECRL into our NGS panel diagnostics for CPVT and LQTS in April 2017. By December 2018, 631 index patients with suspected CPVT or LQTS had been referred to our laboratory for genetic testing. Molecular analysis identified four Caucasian families carrying novel variants in TECRL. One patient was homozygous for Gln139* resulting in a premature stop codon and loss-of-function of the TECRL protein. Another patient was homozygous for Pro290His, probably leading to an altered folding of the 3-oxo-5-alpha steroid 4-dehydrogenase domain of the TECRL protein. The LOF-variant Ser309* and the missense-variant Val298Ala have been shown to be compound heterozygous in another individual. NGS-based copy number variation analysis and quantitative PCR revealed a quadruplication of TECRL in the last individual, which is likely to be a homozygous duplication. CONCLUSION: The data from our patient collective indicate that CPVT3 occurs much more frequently than previously expected. Variants in TECRL may be causative in up to 5% of all CPVT cases. According to these findings, the default analysis of this gene is recommended if CPVT is suspected.


Assuntos
Códon sem Sentido , Variações do Número de Cópias de DNA , Amplificação de Genes , Mutação com Perda de Função , Oxirredutases/genética , Taquicardia Ventricular/genética , Potenciais de Ação , Adolescente , Criança , Feminino , Predisposição Genética para Doença , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Hereditariedade , Heterozigoto , Homozigoto , Humanos , Masculino , Pessoa de Meia-Idade , Oxirredutases/metabolismo , Linhagem , Fenótipo , Dobramento de Proteína , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/enzimologia , Taquicardia Ventricular/fisiopatologia
10.
Eur J Emerg Med ; 23(2): 155-8, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25886777

RESUMO

OBJECTIVES: The triage of trauma patients is based on patient-given information. The aim of the study was the accuracy of pain intensity, subjective functional impairment, trauma history, and clinical examination in identifying patients with fractures. METHODS: We prospectively asked 436 patients with an extremity trauma whether they believed they had a fracture. Pain intensity and subjective functional impairment were also assessed. The physicians were also asked, based on trauma history and clinical examination. RESULTS: The sensitivity and specificity of patient opinion and of the functional questions for fracture detection were low. The combination of history and clinical examination delivered the best results. There was only a slight difference in pain intensity between patients with and those without fractures. CONCLUSION: Fracture diagnosis based only on patient opinion or subjective functional impairment can be misleading. Pain intensity needs further investigation for its role in fracture detection.


Assuntos
Fraturas Ósseas/diagnóstico , Medição da Dor , Dor Aguda/etiologia , Adulto , Traumatismos do Braço/complicações , Traumatismos do Braço/diagnóstico , Serviço Hospitalar de Emergência , Fraturas Ósseas/complicações , Humanos , Traumatismos da Perna/complicações , Traumatismos da Perna/diagnóstico , Masculino , Estudos Prospectivos , Sensibilidade e Especificidade , Triagem/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...