Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
JMIR Mhealth Uhealth ; 7(1): e11458, 2019 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-30617040

RESUMO

BACKGROUND: Pregnancy can be distressing, particularly if expectant mothers are worried about the well-being of their fetus. Consequently, the desire for reassurance and frequent fetal monitoring is often pronounced. Smart wearable devices and telemedicine are promising tools that could assist women in self-monitoring their pregnancy at home, hence disburdening emergency departments (EDs). They present the possibility to clarify the need for urgent care remotely and offer tighter pregnancy monitoring. However, patients' acceptance of such new technologies for fetal monitoring has not yet been explored extensively. OBJECTIVE: This survey aimed to elucidate the attitudes of women toward self-monitoring of their pregnancy using noninvasive electronic devices. The technical details of the proposed devices were not specified. METHODS: A cross-sectional multicenter study was conducted at the departments of obstetrics of the University Hospitals of Heidelberg and Leipzig, Germany. All patients seen in the obstetrics clinic who were above 18 years were offered participation. We designed a survey questionnaire including validated instruments covering population characteristics, issues in current and past pregnancies, as well as attitudes toward self-monitoring of pregnancy with smart devices. RESULTS: A total of 509 pregnant women with no previous experience in telemedicine participated. Only a small minority of 5.9% (29/493) regarded self-monitoring with wearable devices as an alternative to consulting their physicians. Along these lines, only 7.7% (38/496) strongly believed they would visit the ED less often if such devices were readily available. However, if the procedure were combined with a Web-based telemetric physician consult, 13.5% (66/487) would be highly motivated to use the devices. Furthermore, significantly more women regarded it as an alternative prior to seeing a doctor when they perceived a decline in fetal movements (P<.001). Interestingly, women with university degrees had a higher propensity to engage in pregnancy self-monitoring compared with women without one (37% vs 23%; P=.001). Of the participants, 77.9% (381/489) would like smart wearable devices to measure fetal heart sounds, and 62.6% (306/489) wished to use the devices on their own. Feedback from a doctor or midwife was also very important in their choice of such devices (61.8%, 301/487 wished feedback). The intended frequency of use differed vastly among women, ranging from 13.8% (65/471) who would like to use such a device several times per day to 31.6% (149/471) who favored once per week at most. CONCLUSIONS: Our results point to a skeptical attitude toward pregnancy self-monitoring among pregnant women. Nevertheless, many women are open to using devices for pregnancy monitoring in parallel to consulting their physician. The intention to use such devices several times daily or weekly, expressed by more than half of the participants, highlights the potential of such technologies.


Assuntos
Monitorização Fisiológica/instrumentação , Gestantes/psicologia , Autogestão/psicologia , Adolescente , Adulto , Telefone Celular/instrumentação , Telefone Celular/tendências , Estudos Transversais , Feminino , Monitorização Fetal/métodos , Alemanha , Humanos , Monitorização Fisiológica/métodos , Monitorização Fisiológica/normas , Gravidez , Autogestão/métodos , Inquéritos e Questionários , Telemedicina/métodos
2.
J Child Neurol ; 21(5): 426-9, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16901451

RESUMO

As holoprosencephaly and Chiari II malformation differ considerably, both in pathogenesis and in phenotypic localization, the coincidence of both entities is extremely rare. The case presented is, to our knowledge, the first published report comprising a combination of a semilobar holoprosencephaly associated with a Chiari II malformation and a myelomeningocele diagnosed prenatally and confirmed by postmortem neuropathologic evaluation. These findings indicate that in the case of pre- and postnatal detection of a myelomeningocele and/or Chiari II malformation, possible additional intracranial malformation, such as a semilobar holoprosencephaly, should also be taken into account and vice versa.


Assuntos
Malformação de Arnold-Chiari/diagnóstico por imagem , Malformação de Arnold-Chiari/patologia , Holoprosencefalia/diagnóstico por imagem , Holoprosencefalia/patologia , Ultrassonografia Pré-Natal , Adulto , Malformação de Arnold-Chiari/complicações , Feminino , Holoprosencefalia/complicações , Humanos , Meningomielocele/complicações , Meningomielocele/diagnóstico por imagem , Meningomielocele/patologia , Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA