Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Orthop Surg Res ; 19(1): 384, 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38951886

RESUMO

BACKGROUND: It remains unclear whether the use of an orthopaedic traction table (TT) in direct anterior approach (DAA) total hip arthroplasty (THA) results in better outcomes. The aim of this systematic review and network meta-analysis was to compare the THA outcomes through DAA on a standard operating table and the THA outcomes through DAA on a TT. METHODS: PubMed, Epistemonikos, and Google Scholar were searched for relevant randomized controlled trials (RCTs) up to 01 January 2024. An indirect comparison in network meta-analysis was performed to assess treatment effects between DAA on a TT and DAA on a standard table, using fixed-effects and random-effects models estimated with frequentist approach and consistency assumption. Standardized mean differences (SMDs) with 95% confidence intervals (CIs) were estimated for continuous variables and odds ratios (ORs) with 95% CIs were estimated for binary variables. RESULTS: The systematic review of the literature identified 43 RCTs with a total of 2,258 patients. DAA with TT had a 102.3 mL higher intraoperative blood loss and a 0.6 mmol/L lower Hb 3 days postoperatively compared with DAA without TT (SMD = 102.33, 95% CI 47.62 to 157.04; SMD = - 0.60, 95% CI - 1.19 to - 0.00). DAA with TT had a 0.15 lower periprosthetic fracture OR compared with DAA without TT (OR 0.15, 95% CI 0.03 to 0.86). There were no further significant differences in surgical, radiological, functional outcomes and in complication rates. CONCLUSION: Based on our findings and taking into account the limitations, we recommend that particular attention be paid to the risk of periprosthetic fracture in DAA on a standard operating table and blood loss in DAA with TT. Since numerous other surgical, radiological, functional outcome parameters and other complication rates studied showed no significant difference between DAA on a standard operating table and DAA with TT, no recommendation for a change in surgical technique seems justified. LEVEL OF EVIDENCE: Level I evidence, because this is a systematic review and meta-analysis of randomized controlled trials.


Assuntos
Artroplastia de Quadril , Metanálise em Rede , Tração , Humanos , Artroplastia de Quadril/métodos , Tração/métodos , Resultado do Tratamento , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Mesas Cirúrgicas , Ensaios Clínicos Controlados Aleatórios como Assunto , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia
2.
Medicina (Kaunas) ; 60(6)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38929468

RESUMO

Background and Objectives: Muscle properties are critical for performance and injury risk, with changes occurring due to physical exertion, aging, and neurological conditions. The MyotonPro device offers a non-invasive method to comprehensively assess muscle biomechanical properties. This systematic review evaluates the reliability of MyotonPro across various muscles for diagnostic purposes. Materials and Methods: Following PRISMA guidelines, a comprehensive literature search was conducted in Medline (PubMed), Ovid (Med), Epistemonikos, Embase, Cochrane Library, Clinical trials.gov, and the WHO International Clinical Trials platform. Studies assessing the reliability of MyotonPro across different muscles were included. A methodological quality assessment was performed using established tools, and reviewers independently conducted data extraction. Statistical analysis involved summarizing intra-rater and inter-rater reliability measures across muscles. Results: A total of 48 studies assessing 31 muscles were included in the systematic review. The intra-rater and inter-rater reliability were consistently high for parameters such as frequency and stiffness in muscles of the lower and upper extremities, as well as other muscle groups. Despite methodological heterogeneity and limited data on specific parameters, MyotonPro demonstrated promising reliability for diagnostic purposes across diverse patient populations. Conclusions: The findings suggest the potential of MyotonPro in clinical assessments for accurate diagnosis, treatment planning, and monitoring of muscle properties. Further research is needed to address limitations and enhance the applicability of MyotonPro in clinical practice. Reliable muscle assessments are crucial for optimizing treatment outcomes and improving patient care in various healthcare settings.


Assuntos
Músculo Esquelético , Humanos , Reprodutibilidade dos Testes , Músculo Esquelético/fisiologia , Músculo Esquelético/fisiopatologia , Testes Diagnósticos de Rotina/normas , Testes Diagnósticos de Rotina/métodos
3.
J Orthop Surg Res ; 19(1): 311, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38802945

RESUMO

BACKGROUND: The aim of the present study was to investigate the influence of various factors, in particular operation time, on mortality and complication rates in patients with femoral neck fractures who have undergone hip hemiarthroplasty (HHA) and to determine a cut-off value above which mortality and complication rates increase significantly. METHODS: Cases of patients with femoral neck fracture treated with HHA between 1 January 2017 and 31 December 2023 were screened for eligibility. Multiple logistic regressions were calculated to determine which factors (patient age, experience of surgeon, patient sex, ASA score, time to surgery, operation time) influenced the incidence of complications and mortality. The exact cut-off value for complications and mortality was determined using the Youden index of the ROC curve (sensitivity vs. specificity) of logistic regression. RESULTS: A total of 552 patients were considered eligible for this study. During the 90-day follow-up period after HHA, 50 deaths and 34 complications were recorded, giving a mortality rate of 9.1%, and a complication rate of 6.2%. Of the 34 complications recorded, 32.3% were infections, 14.7% dislocations, 20.7% trochanteric avulsions, 11.8% periprosthetic fractures, 11.8% nerve injuries, and 8.8% deep vein thrombosis. The odds ratio (OR) of a patient experiencing a complication is 2.2% higher for every minute increase in operation time (Exponential Beta - 1 = 0.022; p = 0.0363). The OR of a patient dying is 8.8% higher for each year increase in age (Exponential Beta - 1 = 0.088; p = 0.0007). When surgery was performed by a certified orthopaedic surgeon the mortality rate lowered by 61.5% in comparison to the surgery performed by a trainee (1 - Exponential Beta = 0.594; p = 0.0120). Male patients have a 168.7% higher OR for mortality than female patients (Exponential Beta - 1 = 1.687; p = 0.0017). Patients with an operation time of ≥ 86 min. have a 111.8% higher OR for mortality than patients with an operation time of < 86 min. (Exponential Beta - 1 = 1.118). CONCLUSION: This retrospective data analysis found that the risk of a patient experiencing a complication was 2.2% higher for every minute increase in operation time. Patients with an operation time above the cut-off of 86 min had a 111.8% higher risk of mortality than those with an operation time below the cut-off. Other influencing factors that operators should be aware of include patient age, male sex, and operator experience.


Assuntos
Artroplastia de Quadril , Fraturas do Colo Femoral , Hemiartroplastia , Duração da Cirurgia , Complicações Pós-Operatórias , Humanos , Fraturas do Colo Femoral/cirurgia , Fraturas do Colo Femoral/mortalidade , Masculino , Feminino , Estudos Retrospectivos , Hemiartroplastia/efeitos adversos , Hemiartroplastia/métodos , Idoso , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/mortalidade , Pessoa de Meia-Idade
4.
Artigo em Inglês | MEDLINE | ID: mdl-38780774

RESUMO

INTRODUCTION: Anterior knee pain commonly affects young women resulting in the declination of the quality of life. One of the possible pathologies causing this symptom is chondromalacia patellae (CMP). Although CMP is used to describe the softening of patellar articular cartilage, it remains a general descriptive term as it cannot be associated with a specific pathophysiologic mechanism. The objective of this study is to investigate the effect of injectable PRP on patients with anterior knee pain in absence of altered patellofemoral joint anatomy. METHODS: For this purpose, 43 patients of the affected population were recruited to participate in this non-randomized controlled trial, 28 patients in the injection group and 15 in the only-physiotherapy group. While patients in the experimental group received three PRP injections and one injection of hyaluronic acid (HA), comparators received the standard physical therapy regimen. The treatment choice was based on patients own decree. Patients between the ages of 18 to 50 years with anterior knee pain and positive Clarke´s sign were eligible for inclusion. Patients with evident anatomical abnormalities, chronic conditions affecting the knee and severe symptoms such as blocking, were excluded from the study. Patient related measures (PROMS) in the form of the VAS and the Kujala scores were the main outcome of interest. All outcomes were measured at baseline, and after 3 and 6 months after the treatment. RESULTS: Although an improvement was seen in both groups, a statistically significant difference favoring the injection of PRP over the physiotherapy-only group was observed (p < 0.001). The superiority of the therapeutic modality under investigation was observed at 3 and 6 months after the initial diagnosis was made. Furthermore, the results of this study revealed a significant improvement at 3 and 6 months when compared to baseline measures. The analysis of the patients age showed a negative correlation when baseline values were compared to measures at 3 and 6 months, meaning younger patients had more benefit from the treatment. DISCUSSION: The main results of this study affirm the positive effects of PRP and HA for the treatment of anterior knee pain described by previous research and the subsequent improvement of the quality of life. Relatively little information was found in the literature search regarding the therapeutic effects of PRP on anterior knee pain and chondropathies. While a previous radiologic study found no evidence regarding the effect of PRP, this study found a benefit when comparing PROMs between patient groups.

5.
J Pers Med ; 14(3)2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38541043

RESUMO

BACKGROUND: The investigation of soft tissue stiffness has garnered increasing interest due to its potential applications in detecting tissue conditions, monitoring therapy effects, and preventing sports injuries. This study utilized the MyotonPro as a reliable measurement device to assess muscle stiffness and muscle frequency in the vastus lateralis and medialis muscles of both the dominant and non-dominant legs. METHODS: Sixteen young, healthy subjects (seven males and nine females, age 25 ± 3.46 years) participated in this study. To induce maximal muscle fatigue, the vastus lateralis and vastus medialis muscles were subjected to a 30 kg load using a single-leg leg press. Pre- and post-fatigue measurements were conducted by two testers on the dominant and non-dominant legs, respectively, employing the MyotonPro. RESULTS: We revealed a significant increase in muscle stiffness after maximal muscle fatigue. Specifically, on the dominant side, the vastus lateralis exhibited a stiffness increase of 6.5%, while the vastus medialis showed a 6.3% increase. On the non-dominant side, the vastus lateralis demonstrated a 7.6% increase, and the vastus medialis exhibited a 6.7% increase in muscle stiffness. Furthermore, muscle frequency increased by 8.6% (vastus lateralis) and 13.5% (vastus medialis) on the dominant side and by 15.1% (vastus lateralis) and 6.3% (vastus medialis) on the non-dominant side. The reliability of the measurements varied, with Cronbach's alpha values ranging from inadequate 0.49 to very good 0.88. CONCLUSION: This study affirms the efficacy of the MyotonPro as a measurement device for assessing muscle stiffness and establishes its reliability. The observed increase in muscle stiffness after maximal muscle fatigue, accompanied by changes in muscle frequency, underscores the device's utility. However, further research is warranted to validate the reproducibility of these findings and explore additional facets of the muscular response to fatigue.

7.
JMIR Form Res ; 8: e52164, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38363631

RESUMO

BACKGROUND: As large language models (LLMs) are becoming increasingly integrated into different aspects of health care, questions about the implications for medical academic literature have begun to emerge. Key aspects such as authenticity in academic writing are at stake with artificial intelligence (AI) generating highly linguistically accurate and grammatically sound texts. OBJECTIVE: The objective of this study is to compare human-written with AI-generated scientific literature in orthopedics and sports medicine. METHODS: Five original abstracts were selected from the PubMed database. These abstracts were subsequently rewritten with the assistance of 2 LLMs with different degrees of proficiency. Subsequently, researchers with varying degrees of expertise and with different areas of specialization were asked to rank the abstracts according to linguistic and methodological parameters. Finally, researchers had to classify the articles as AI generated or human written. RESULTS: Neither the researchers nor the AI-detection software could successfully identify the AI-generated texts. Furthermore, the criteria previously suggested in the literature did not correlate with whether the researchers deemed a text to be AI generated or whether they judged the article correctly based on these parameters. CONCLUSIONS: The primary finding of this study was that researchers were unable to distinguish between LLM-generated and human-written texts. However, due to the small sample size, it is not possible to generalize the results of this study. As is the case with any tool used in academic research, the potential to cause harm can be mitigated by relying on the transparency and integrity of the researchers. With scientific integrity at stake, further research with a similar study design should be conducted to determine the magnitude of this issue.

8.
Orthop Surg ; 16(4): 791-801, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38298174

RESUMO

Specialist literature lacks evidence that explores associations between patient characteristics and the beneficial treatment effect of SuperPATH hemiarthroplasty (HA) compared with conventional approach (CA) HA. To investigate and identify patient-related predictors of the effect size of the short-term functional outcome of SuperPATH HA and CA HA by performing a systematic review and meta-regression analysis of randomized controlled trials (RCTs). A systematic search of literature was performed in PubMed, CNKI, CENTRAL of The Cochrane Library, Clinical trials, and Google Scholar until August 25, 2023. For the continuous outcome parameter Harris hip score (HHS) ≤1 week and 3 months postoperatively, mean differences (MDs) with 95% confidence intervals (CIs) were calculated. A meta-regression analysis was based on random-effects meta-analysis using the Hartung-Knapp-Sidik-Jonkman method for continuous covariates. A total of five RCTs with 404 patients were found. The following predictors of HHS ≤1 week postoperatively were identified: patient age (predictor estimate = 1.29; p < 0.01), patient age groups (predictor estimate = 14.07; p < 0.01), time to mobilization (predictor estimate = 5.51; p < 0.01). The following predictors of HHS 3 months postoperatively were identified: incision length (predictor estimate = -2.12; p < 0.01); intraoperative blood loss (predictor estimate = 0.02; p < 0.01). Patient age, time to mobilization, incision length, and intraoperative blood loss were identified as predictors of the effect size of early postoperative functional outcome as measured by HHS. Elderly patients, particularly those over 70 years of age, appear to benefit from SuperPATH HA. Based on these findings, and taking into account our limitations, we recommend that the use of minimally invasive SuperPATH HA in elderly patients should be more widely considered and not limited to elective THA patients.


Assuntos
Artroplastia de Quadril , Hemiartroplastia , Humanos , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Hemiartroplastia/métodos , Perda Sanguínea Cirúrgica , Ensaios Clínicos Controlados Aleatórios como Assunto , Período Pós-Operatório , Resultado do Tratamento
9.
J Pers Med ; 13(12)2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-38138855

RESUMO

Inertial measurement units (IMUs) are increasingly being used to assess knee function. The aim of the study was to record patients' activity levels and to detect new parameters for knee function in the early postoperative phase after TKA. Twenty patients (n = 20) were prospectively enrolled. Two sensors were attached to the affected leg. The data were recorded from the first day after TKA until discharge. Algorithms were developed for detecting steps, range of motion, horizontal, sitting and standing postures, as well as physical therapy. The mean number of steps increased from day 1 to discharge from 117.4 (SD ± 110.5) to 858.7 (SD ± 320.1), respectively. Patients' percentage of immobilization during daytime (6 a.m. to 8 p.m.) was 91.2% on day one and still 69.9% on the last day. Patients received daily continuous passive motion therapy (CPM) for a mean of 36.4 min (SD ± 8.2). The mean angular velocity at day 1 was 12.2 degrees per second (SD ± 4.4) and increased to 28.7 (SD ± 16.4) at discharge. This study shows that IMUs monitor patients' activity postoperatively well, and a wide range of interindividual motion patterns was observed. These sensors may allow the adjustment of physical exercise programs according to the patient's individual needs.

10.
J Pers Med ; 13(12)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38138865

RESUMO

BACKGROUND: The elements of previously designed questionnaires do not take into consideration the burdens encountered in an inpatient hospital setting. The purpose of this study is to validate elements of a non-compliance survey in an in-hospital setting and discuss aspects of compliance with telerehabilitative physiotherapy in the early postoperative period. METHODS: A literature search was conducted to identify elements that prevent patients from performing their prescribed physical therapy exercises. These items were then evaluated by the expert review technique as described by Ikart. Afterwards, the synthesized survey was handed out to patients for the assessment of the quality of its items. RESULTS: The results of the expert review technique identified some conceptual and grammatical problems. This led to the adjustment of some of the elements. The quality of the resulting questionnaire was deemed to be good, as patients were able to fully understand the concepts and answer accordingly. A statistical analysis was conducted to evaluate the responses. CONCLUSIONS: The items of this second questionnaire have proven to be reliable to assess the compliance of patients in an in-hospital setting. These items will be added to the cross-culturally adapted items of a previous questionnaire.

11.
J Pers Med ; 13(9)2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37763121

RESUMO

BACKGROUND: Compliance with rehabilitative physiotherapeutic measures leads to an improvement in outcomes in patients suffering from a variety of musculoskeletal conditions. To date, a tool for assessing the parameters that lead to non-adherence to physical therapy does not exist in the German language. The objective of this paper is to cross-culturally adapt a non-compliance questionnaire to German. METHODS: In reference to the "Guidelines for the Process of Cross-Cultural Adaption of Self-Reported Measures", the questionnaire was translated into German followed by a back-translation into the original language. An expert committee met and refined the pre-final version. A preliminary version was handed out to patients for evaluation of the quality of the resulting German version. RESULTS: After the forward- and back-translation of the questionnaire, some discrepancies were discovered between the translators on the one hand and between the back-translations and the original document on the other. The statistical analysis showed satisfactory results regarding the quality of the questionnaire. CONCLUSION: The translation and adaption of the items proved to have a high degree of reliability. The German version will be made available for German-speaking researchers and used for evaluating a mobile-application-based physical therapy regimen by the authors of the paper.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...