Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
J Vasc Interv Radiol ; 34(12): 2218-2223.e10, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37619940

RESUMO

Registry data are being increasingly used to establish treatment guidelines, set benchmarks, allocate resources, and make payment decisions. Although many registries rely on manual data entry, the Society of Interventional Radiology (SIR) is using automated data extraction for its VIRTEX registry. This process relies on participants using consistent terminology with highly structured data in physician-developed standardized reports (SR). To better understand barriers to adoption, a survey was sent to 3,178 SIR members. Responses were obtained from 451 interventional radiology practitioners (14.2%) from 92 unique academic and 151 unique private practices. Of these, 75% used structured reports and 32% used the SIR SR. The most common barriers to the use of these reports include SR length (35% of respondents), lack of awareness about the SR (31%), and lack of agreement on adoption within practices (27%). The results demonstrated insights regarding barriers in the use and/or adoption of SR and potential solutions.


Assuntos
Médicos , Sistemas de Informação em Radiologia , Humanos , Radiologia Intervencionista , Inquéritos e Questionários
3.
J Vasc Interv Radiol ; 34(11): 2012-2019, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37517464

RESUMO

Quality improvement (QI) initiatives have benefited patients as well as the broader practice of medicine. Large-scale QI has been facilitated by multi-institutional data registries, many of which were formed out of national or international medical society initiatives. With broad participation, QI registries have provided benefits that include but are not limited to establishing treatment guidelines, facilitating research related to uncommon procedures and conditions, and demonstrating the fiscal and clinical value of procedures for both medical providers and health systems. Because of the benefits offered by these databases, Society of Interventional Radiology (SIR) and SIR Foundation have committed to the development of an interventional radiology (IR) clinical data registry known as VIRTEX. A large IR database with participation from a multitude of practice environments has the potential to have a significant positive impact on the specialty through data-driven advances in patient safety and outcomes, clinical research, and reimbursement. This article reviews the current landscape of societal QI programs, presents a vision for a large-scale IR clinical data registry supported by SIR, and discusses the anticipated results that such a framework can produce.


Assuntos
Melhoria de Qualidade , Radiologia Intervencionista , Humanos , Sistema de Registros , Sociedades Médicas , Bases de Dados Factuais
5.
ArXiv ; 2021 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-34815983

RESUMO

Artificial intelligence (AI) provides a promising substitution for streamlining COVID-19 diagnoses. However, concerns surrounding security and trustworthiness impede the collection of large-scale representative medical data, posing a considerable challenge for training a well-generalised model in clinical practices. To address this, we launch the Unified CT-COVID AI Diagnostic Initiative (UCADI), where the AI model can be distributedly trained and independently executed at each host institution under a federated learning framework (FL) without data sharing. Here we show that our FL model outperformed all the local models by a large yield (test sensitivity /specificity in China: 0.973/0.951, in the UK: 0.730/0.942), achieving comparable performance with a panel of professional radiologists. We further evaluated the model on the hold-out (collected from another two hospitals leaving out the FL) and heterogeneous (acquired with contrast materials) data, provided visual explanations for decisions made by the model, and analysed the trade-offs between the model performance and the communication costs in the federated training process. Our study is based on 9,573 chest computed tomography scans (CTs) from 3,336 patients collected from 23 hospitals located in China and the UK. Collectively, our work advanced the prospects of utilising federated learning for privacy-preserving AI in digital health.

6.
Nat Mach Intell ; 3(12): 1081-1089, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38264185

RESUMO

Artificial intelligence provides a promising solution for streamlining COVID-19 diagnoses; however, concerns surrounding security and trustworthiness impede the collection of large-scale representative medical data, posing a considerable challenge for training a well-generalized model in clinical practices. To address this, we launch the Unified CT-COVID AI Diagnostic Initiative (UCADI), where the artificial intelligence (AI) model can be distributedly trained and independently executed at each host institution under a federated learning framework without data sharing. Here we show that our federated learning framework model considerably outperformed all of the local models (with a test sensitivity/specificity of 0.973/0.951 in China and 0.730/0.942 in the United Kingdom), achieving comparable performance with a panel of professional radiologists. We further evaluated the model on the hold-out (collected from another two hospitals without the federated learning framework) and heterogeneous (acquired with contrast materials) data, provided visual explanations for decisions made by the model, and analysed the trade-offs between the model performance and the communication costs in the federated training process. Our study is based on 9,573 chest computed tomography scans from 3,336 patients collected from 23 hospitals located in China and the United Kingdom. Collectively, our work advanced the prospects of utilizing federated learning for privacy-preserving AI in digital health.

7.
medRxiv ; 2020 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-32511484

RESUMO

Artificial intelligence can potentially provide a substantial role in streamlining chest computed tomography (CT) diagnosis of COVID-19 patients. However, several critical hurdles have impeded the development of robust AI model, which include deficiency, isolation, and heterogeneity of CT data generated from diverse institutions. These bring about lack of generalization of AI model and therefore prevent it from applications in clinical practices. To overcome this, we proposed a federated learning-based Unified CT-COVID AI Diagnostic Initiative (UCADI, http://www.ai-ct-covid.team/), a decentralized architecture where the AI model is distributed to and executed at each host institution with the data sources or client ends for training and inferencing without sharing individual patient data. Specifically, we firstly developed an initial AI CT model based on data collected from three Tongji hospitals in Wuhan. After model evaluation, we found that the initial model can identify COVID from Tongji CT test data at near radiologist-level (97.5% sensitivity) but performed worse when it was tested on COVID cases from Wuhan Union Hospital (72% sensitivity), indicating a lack of model generalization. Next, we used the publicly available UCADI framework to build a federated model which integrated COVID CT cases from the Tongji hospitals and Wuhan Union hospital (WU) without transferring the WU data. The federated model not only performed similarly on Tongji test data but improved the detection sensitivity (98%) on WU test cases. The UCADI framework will allow participants worldwide to use and contribute to the model, to deliver a real-world, globally built and validated clinic CT-COVID AI tool. This effort directly supports the United Nations Sustainable Development Goals' number 3, Good Health and Well-Being, and allows sharing and transferring of knowledge to fight this devastating disease around the world.

9.
J Cardiothorac Vasc Anesth ; 33(1): 245-248, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29631945

RESUMO

Prosthesis-patient mismatch (PPM) is relatively common after aortic valve replacement (AVR) and generally is associated with reduced regression of left ventricular (LV) mass. PPM after valve-in-valve transcatheter aortic valve replacement (TAVR) was reported to be 38%. PPM generally is manifested clinically by dyspnea and echocardiographically by high transvalvular gradients. In this E-Challenge, the authors will review a case of a late clinical presentation of PPM 1-year following a valve-in-valve TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Cateterismo Cardíaco , Ecocardiografia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Fatores de Risco , Fatores de Tempo
12.
J Vasc Access ; 16(4): 309-14, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25656250

RESUMO

PURPOSE: The purpose of this study is to evaluate the safety and efficacy of using a radiofrequency wire (RF) for central venous occlusion (CVO) recanalization after failure using conventional techniques. MATERIALS AND METHODS: A retrospective analysis of all central venous recanalization procedures using an RF wire from January 2007 to December 2012 was performed. This comprised 13 consecutive procedures in 12 patients. The electronic medical record and radiologic imaging studies were reviewed to obtain information regarding patient demographics, indication for revascularization, duration of vascular occlusion, procedure outcome, and complications. RESULTS: Technical success was achieved in nine of 13 (69%) occluded vessels in nine of 12 (75%) patients. Lengths of successfully crossed lesions (mean 29.8 ± 29.3 mm) were significantly less than those of unsuccessfully crossed lesions (mean 90 ± 73.7 mm), p = 0.039. Of the nine patients with technically successful procedures, three died with patent stents of causes unrelated to the procedure, one had a patent stent at 547 days, two had stent patency of 94 days and 345 days, and three were lost to follow-up. One patient (8.3%) experienced a major complication wherein tracheal perforation by the RF wire contributed to the patient's death. CONCLUSIONS: RF recanalization is a viable option in patients with central vein occlusion refractory to traditional procedures. However, it does not guarantee successful revascularization and is not without the potential for harm.


Assuntos
Ablação por Cateter/instrumentação , Dispositivos de Acesso Vascular , Doenças Vasculares/terapia , Veias , Adulto , Idoso , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Ablação por Cateter/efeitos adversos , Doença Crônica , Constrição Patológica , Registros Eletrônicos de Saúde , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Flebografia/métodos , Radiografia Intervencionista , Estudos Retrospectivos , Stents , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Doenças Vasculares/diagnóstico , Doenças Vasculares/etiologia , Doenças Vasculares/fisiopatologia , Grau de Desobstrução Vascular , Veias/fisiopatologia , Adulto Jovem
14.
J Ultrasound Med ; 33(12): 2137-43, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25425370

RESUMO

OBJECTIVES: To evaluate the diagnostic yield of complete lower extremity venous sonography for diagnosing deep venous thrombosis (DVT) in patients undergoing computed tomographic (CT) pulmonary angiography for suspected pulmonary embolism (PE). METHODS: We retrospectively reviewed all cases of lower extremity venous sonography and CT pulmonary angiography performed within 1 day of each other (n = 147) in a tertiary care center. Indications for the studies performed, angiographic findings, sonographic findings, age, sex, inpatient/outpatient status, lower extremity symptoms, and treatment status were recorded. Prevalence rates and patient characteristics were compared by χ(2) and Fisher exact probability tests where appropriate. Multivariable logistic regression with acute PE as the outcome was performed for age, sex, interval between angiography and sonography, indication for angiography, inpatient/outpatient status, and venous sonographic findings. RESULTS: The prevalence of PE (23.8%) was similar to the prevalence of DVT (27.9%). Angiographic findings were not associated with the interval between angiography and sonography or inpatient/outpatient status. Acute DVT was more likely (P = .0009) when angiographic findings were positive (51.4%), but DVT prevalence was still substantial (20.5%) in patients with negative angiographic findings. Lower extremity symptoms were not associated with DVT in cases with negative angiographic findings (P = .48). Eighteen of the 23 patients with acute DVT and negative angiographic findings were treated. CONCLUSIONS: There is a high rate of DVT in a population undergoing CT pulmonary angiography for suspected PE even when PE is not diagnosed. Our data apply to a tertiary care institution, suggest a surveillance bias, and favor the utility of venous sonography in this population.


Assuntos
Angiografia/estatística & dados numéricos , Extremidade Inferior/irrigação sanguínea , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/epidemiologia , Ultrassonografia/estatística & dados numéricos , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/epidemiologia , Distribuição por Idade , Boston/epidemiologia , Causalidade , Comorbidade , Feminino , Humanos , Extremidade Inferior/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Distribuição por Sexo , Tomografia Computadorizada por Raios X/estatística & dados numéricos
15.
J Vasc Access ; 15(3): 157-62, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24474522

RESUMO

Arteriovenous hemodialysis fistulas (AVFs) serve as a lifeline for many individuals with end-stage renal failure. A common cause of AVF failure is cephalic arch stenosis. Its high prevalence compounded with its resistance to treatment makes cephalic arch stenosis important to understand. Proposed etiologies include altered flow in a fistulized cephalic vein, external compression by fascia, the unique morphology of the cephalic arch, large number of valves in the cephalic outflow tract and biochemical changes that accompany renal failure. Management options are also in debate and include angioplasty, cutting balloon angioplasty, bare metal stents, stent grafts and surgical techniques including flow reduction with minimally invasive banding as well as more invasive venovenostomy with transposition surgeries for refractory cases. In this review, the evidence for the clinical relevance of cephalic arch stenosis, its etiology and management are summarized.


Assuntos
Derivação Arteriovenosa Cirúrgica/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Falência Renal Crônica/terapia , Diálise Renal , Constrição Patológica , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Hemodinâmica , Humanos , Falência Renal Crônica/diagnóstico , Fluxo Sanguíneo Regional , Fatores de Risco , Resultado do Tratamento
16.
J Vasc Surg ; 58(5): 1339-45, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23663872

RESUMO

OBJECTIVE: We hypothesized that fluoroscopic imaging creates radiation fields that are unevenly scattered throughout the endovascular suite. We sought to quantify the radiation dose spectrum at various locations during imaging procedures and to represent this in a clinically useful manner. METHODS: Digital subtraction imaging (Innova 4100; GE Healthcare, Waukesha, Wisc) of the abdomen and pelvis was performed on a cadaver in anteroposterior, left lateral, and right anterior oblique 45° projections. Radiation exposure was monitored in real time with DoseAware dosimeters (Phillips, Houston, Tex) in eight radial projections at distances of 2, 4, and 6 ft from the center of the imaged field, each at 5-ft heights from the floor. Three to five consecutive data points were collected for each location. RESULTS: At most positions around the angiographic table, radiation exposure decreased as the distance from the source emitter increased; however, the intensity of the exposure varied dramatically around the axis of imaging. With anteroposterior imaging, the radiation fields have symmetric dumbbell shapes, with maximal exposure perpendicular to the table at the level of the gantry. Peak levels at 4 and 6 ft from the source emitter were 2.4 times and 3.4 times higher, respectively, than predicted based on the inverse square law. Maximal radiation exposure was measured in the typical operator position 2 ft away and perpendicular to the table (4.99 mSv/h). When the gantry was rotated 45° and 90°, the radiation fields shifted, becoming more asymmetric, with increasing radiation doses to 10.9 and 69 mSv/h, respectively, on the side of the emitter. Minimal exposure is experienced along the axis of the table, decreasing with distance from the source (<0.77 mSv/h). CONCLUSIONS: Quantifiable and reproducible radiation scatter is created during interventional procedures. Radiation doses vary widely around the perimeter of the angiography table and change according to imaging angles. These data are easily visualized using contour plots and scatter three-dimensional mesh plots. Rather than the concentric circles predicted by the inverse square law, these data more closely resemble a "scatter cloud." Knowledge of the actual exposure levels within the endovascular environment may help in mitigating these risks to health care providers.


Assuntos
Angiografia Digital , Procedimentos Endovasculares , Exposição Ocupacional , Doses de Radiação , Radiografia Intervencionista , Angiografia Digital/efeitos adversos , Cadáver , Procedimentos Endovasculares/efeitos adversos , Humanos , Masculino , Doenças Profissionais/etiologia , Doenças Profissionais/prevenção & controle , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Saúde Ocupacional , Posicionamento do Paciente , Lesões por Radiação/etiologia , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação/métodos , Proteção Radiológica , Radiografia Intervencionista/efeitos adversos , Espalhamento de Radiação
17.
J Vasc Surg ; 57(1): 214-7, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23141677

RESUMO

Variations in abdominal aortic anatomy may have significant implications in various surgical procedures. We report here a pediatric patient with symptoms of chronic mesenteric ischemia, labile hypertension, and lower extremity claudication. Angiography revealed a partially duplicated aorta with the anterior aorta containing the splanchnic and renal arteries and the posterior segment perfusing the lower extremities. She was successfully treated with balloon angioplasty of two focal stenoses and is normotensive without abdominal symptoms at 1-year follow-up. To our knowledge, this is the first report of a successful endovascular intervention in a partially duplicated aorta.


Assuntos
Angioplastia com Balão , Aorta Abdominal/anormalidades , Doenças da Aorta/terapia , Hipertensão Renovascular/terapia , Isquemia/terapia , Obstrução da Artéria Renal/terapia , Doenças Vasculares/terapia , Malformações Vasculares/complicações , Adolescente , Angiografia Digital , Angioplastia com Balão/instrumentação , Aorta Abdominal/diagnóstico por imagem , Doenças da Aorta/diagnóstico , Doenças da Aorta/etiologia , Aortografia , Constrição Patológica , Feminino , Humanos , Hipertensão Renovascular/diagnóstico , Hipertensão Renovascular/etiologia , Claudicação Intermitente/etiologia , Claudicação Intermitente/terapia , Isquemia/diagnóstico , Isquemia/etiologia , Angiografia por Ressonância Magnética , Isquemia Mesentérica , Obstrução da Artéria Renal/complicações , Obstrução da Artéria Renal/diagnóstico , Stents , Resultado do Tratamento , Doenças Vasculares/diagnóstico , Doenças Vasculares/etiologia , Malformações Vasculares/diagnóstico
18.
J Vasc Surg ; 55(3): 799-805, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22079168

RESUMO

OBJECTIVES: To determine radiation exposure for members of an endovascular surgery team during imaging procedures by varying technique. METHODS: Digital subtraction angiography imaging of the abdomen and pelvis (Innova 4100; GE, Fairfield, Conn) was performed on cadavers, varying positioning and technique within the usual bounds of clinical practice. Radiation exposure was monitored in real-time with dosimeters (DoseAware; Philips, Andover, Mass) to simulate the position of the operator, assistant, and anesthesiologist. The DoseAware system reports radiation exposure in 1-second intervals. Three to five consecutive data points were collected for each imaging configuration. RESULTS: Operator radiation exposure is minimized with detector-to-patient distance <5 cm (2.1 mSv/h) in contrast to 10 to 15 cm (2.8 mSv/h); source-to-image distance of <15 cm (2.3 mSv/h) in contrast to 25 cm (3.3 mSv/h). Increasing image magnification from 0 (2.3 mSv/h) to 3 (0.83 mSv/h) decreases operator exposure by 74%. Increasing linear image collimation from 0 (2.3 mSv/h) to 10 cm (0.30 mSv/h) decreases operator exposure by 87%. The anesthesiologist's radiation exposure is 11% to 49% of the operator's, greatest in the left anterior oblique (LAO) 90 degree projection. The assistant's radiation exposure is 23% to 46% of the operator's. The highest exposure to the operator was noted to be in the LAO 90 degree projection (30.3 mSv/h) and lowest exposure with 10-cm vertical collimation (0.28 mSv/h). CONCLUSIONS: Varying imaging techniques results in different radiation exposure to members of an endovascular surgery team. Knowledge of the variable intensity of radiation exposure may allow modification of the technique to minimize radiation exposure to the team while providing suitable imaging.


Assuntos
Angiografia Digital , Procedimentos Endovasculares , Doenças Profissionais/prevenção & controle , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Lesões por Radiação/prevenção & controle , Radiografia Intervencionista , Procedimentos Cirúrgicos Vasculares , Angiografia Digital/efeitos adversos , Cadáver , Procedimentos Endovasculares/efeitos adversos , Dosimetria Fotográfica , Humanos , Masculino , Doenças Profissionais/etiologia , Lesões por Radiação/etiologia , Radiografia Intervencionista/efeitos adversos , Medição de Risco , Fatores de Risco , Espalhamento de Radiação , Fatores de Tempo , Procedimentos Cirúrgicos Vasculares/efeitos adversos
19.
Kidney Int ; 81(6): 577-85, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22205355

RESUMO

HALT PKD consists of two ongoing randomized trials with the largest cohort of systematically studied patients with autosomal dominant polycystic kidney disease to date. Study A will compare combined treatment with an angiotensin-converting inhibitor and receptor blocker to inhibitor alone and standard compared with low blood pressure targets in 558 early-stage disease patients with an eGFR over 60 ml/min per 1.73 m(2). Study B will compare inhibitor-blocker treatment to the inhibitor alone in 486 late-stage patients with eGFR 25-60 ml/min per 1.73 m(2). We used correlation and multiple regression cross-sectional analyses to determine associations of baseline parameters with total kidney, liver, or liver cyst volumes measured by MRI in Study A and eGFR in both studies. Lower eGFR and higher natural log-transformed urine albumin excretion were independently associated with a larger natural log-transformed total kidney volume adjusted for height (ln(HtTKV)). Higher body surface area was independently associated with a higher ln(HtTKV) and lower eGFR. Men had larger height-adjusted total kidney volume and smaller liver cyst volumes than women. A weak correlation was found between the ln(HtTKV) and natural log-transformed total liver volume adjusted for height or natural log liver cyst volume in women only. Women had higher urine aldosterone excretion and lower plasma potassium. Thus, our analysis (1) confirms a strong association between renal volume and functional parameters, (2) shows that gender and other factors differentially affect the development of polycystic disease in the kidney and liver, and (3) suggests an association between anthropomorphic measures reflecting prenatal and/or postnatal growth and disease severity.


Assuntos
Bloqueadores do Receptor Tipo 1 de Angiotensina II/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Anti-Hipertensivos/uso terapêutico , Hipertensão/tratamento farmacológico , Falência Renal Crônica/prevenção & controle , Rim/efeitos dos fármacos , Rim Policístico Autossômico Dominante/tratamento farmacológico , Adulto , Pressão Sanguínea/efeitos dos fármacos , Distribuição de Qui-Quadrado , Cistos/genética , Cistos/patologia , Progressão da Doença , Método Duplo-Cego , Quimioterapia Combinada , Feminino , Predisposição Genética para Doença , Taxa de Filtração Glomerular/efeitos dos fármacos , Humanos , Hipertensão/genética , Hipertensão/patologia , Hipertensão/fisiopatologia , Rim/patologia , Rim/fisiopatologia , Falência Renal Crônica/genética , Falência Renal Crônica/patologia , Falência Renal Crônica/fisiopatologia , Hepatopatias/genética , Hepatopatias/patologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Tamanho do Órgão , Rim Policístico Autossômico Dominante/genética , Rim Policístico Autossômico Dominante/patologia , Rim Policístico Autossômico Dominante/fisiopatologia , Estudos Prospectivos , Análise de Regressão , Medição de Risco , Fatores de Risco , Resultado do Tratamento
20.
J Vasc Surg ; 55(2): 603-6, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22104339

RESUMO

Conventional techniques for central venous recanalization are successful in crossing most lesions but still fail in many patients. We used a radiofrequency wire in these failed cases. We report three patients with complicated central venous occlusions in whom conventional catheter and guidewire techniques were not successful and who were successfully treated using the PowerWire Radiofrequency Guidewire (Baylis Medical Company Inc, Montreal, QC, Canada). Occlusions were traversed using the radiofrequency wire, followed by angioplasty and stenting. The average length recanalized was 8.2 ± 3.6 cm. One patient required repeat angioplasty at 4 months. All stents were patent at 12 to 15 months. The radiofrequency wire is valuable in the management of patients with refractory central venous occlusions.


Assuntos
Ablação por Cateter/instrumentação , Cateterismo Venoso Central/efeitos adversos , Catéteres , Síndrome da Veia Cava Superior/cirurgia , Veia Cava Superior/cirurgia , Adulto , Angioplastia/instrumentação , Doença Crônica , Constrição Patológica , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Flebografia , Stents , Síndrome da Veia Cava Superior/diagnóstico por imagem , Síndrome da Veia Cava Superior/etiologia , Resultado do Tratamento , Veia Cava Superior/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...