Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cataract Refract Surg ; 39(6): 873-80, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23688874

RESUMO

PURPOSE: To evaluate the effect of reducing the number of visual acuity measurements made in a defocus curve on the quality of data quantified. SETTING: Midland Eye, Solihull, United Kingdom. DESIGN: Evaluation of a technique. METHODS: Defocus curves were constructed by measuring visual acuity on a distance logMAR letter chart, randomizing the test letters between lens presentations. The lens powers evaluated ranged between +1.50 diopters (D) and -5.00 D in 0.50 D steps, which were also presented in a randomized order. Defocus curves were measured binocularly with the Tecnis diffractive, Rezoom refractive, Lentis rotationally asymmetric segmented (+3.00 D addition [add]), and Finevision trifocal multifocal intraocular lenses (IOLs) implanted bilaterally, and also for the diffractive IOL and refractive or rotationally asymmetric segmented (+3.00 D and +1.50 D adds) multifocal IOLs implanted contralaterally. Relative and absolute range of clear-focus metrics and area metrics were calculated for curves fitted using 0.50 D, 1.00 D, and 1.50 D steps and a near add-specific profile (ie, distance, half the near add, and the full near-add powers). RESULTS: A significant difference in simulated results was found in at least 1 of the relative or absolute range of clear-focus or area metrics for each of the multifocal designs examined when the defocus-curve step size was increased (P<.05). CONCLUSION: Faster methods of capturing defocus curves from multifocal IOL designs appear to distort the metric results and are therefore not valid. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Óculos , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Presbiopia/diagnóstico , Testes Visuais , Acuidade Visual/fisiologia , Aberrometria , Idoso , Comprimento Axial do Olho , Topografia da Córnea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Óptica e Fotônica , Presbiopia/terapia , Refração Ocular/fisiologia
2.
Invest Ophthalmol Vis Sci ; 54(5): 3691-701, 2013 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-23548617

RESUMO

PURPOSE: To evaluate factors affecting corneoscleral profile (CSP) using anterior segment optical coherence tomography (AS-OCT) in combination with conventional videokeratoscopy. METHODS: OCT DATA WERE COLLECTED FROM 204 SUBJECTS OF MEAN AGE 34.9 YEARS (SD: ±15.2 years, range 18-65) using the Zeiss Visante AS-OCT and Medmont M300 corneal topographer. Measurements of corneal diameter (CD), corneal sagittal height (CS), iris diameter (ID), corneoscleral junction angle (CSJ), and scleral radius (SR) were extracted from multiple OCT images. Horizontal visible iris diameter (HVID) and vertical palpebral aperture (PA) were measured using a slit lamp graticule. Subject body height was also measured. Associations were then sought between CSP variables and age, height, ethnicity, sex, and refractive error. RESULTS: Significant correlations were found between age and ocular topography variables of HVID, PA, CSJ, SR, and ID (P < 0.0001), while height correlated with HVID, CD, and ID, and power vector terms with vertical plane keratometry, CD, and CS. Significant differences were noted between ethnicities with respect to CD (P = 0.0046), horizontal and vertical CS (P = 0.0068 and P = 0.0095), and horizontal ID (P = 0.0010). The same variables, with the exception of vertical CS, also varied with sex; horizontal CD (P = 0.0018), horizontal CS (P = 0.0018), and ID (P = 0.0012). Age accounted for the greatest variance in topography variables (36%). CONCLUSIONS: Age is the main factor influencing CSP; this should be taken into consideration in contact lens design, IOL selection, and in the optimization of surgical procedures. Ocular topography also varied with height, sex, ethnicity, and refractive error.


Assuntos
Córnea/anatomia & histologia , Topografia da Córnea/métodos , Topografia da Córnea/normas , Esclera/anatomia & histologia , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/normas , Adolescente , Adulto , Fatores Etários , Idoso , Segmento Anterior do Olho/anatomia & histologia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Erros de Refração/patologia , Reprodutibilidade dos Testes , Fatores Sexuais , Adulto Jovem
3.
Invest Ophthalmol Vis Sci ; 52(9): 6801-6, 2011 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-21685339

RESUMO

PURPOSE: To evaluate the influence of peripheral ocular topography, as evaluated by optical coherence tomography (OCT), compared with traditional measures of corneal profile using keratometry and videokeratoscopy, on soft contact lens fit. METHODS: Ocular surface topography was analyzed in 50 subjects aged 22.8 years (SD ±5.0) using videokeratoscopy (central keratometry, corneal height, and shape factor) and OCT to give both full sagittal cross-sections of the cornea and cross-sections of the corneoscleral junctions. Corneoscleral junction angle, corneal diameter, corneal sagittal height, and scleral radius were analyzed from the images. Horizontal visible iris diameter and vertical palpebral aperture were analyzed from digital slit lamp images. Lens fit was graded after 30 minutes wear of a -2.50 D commercially available standard hydrogel (etafilcon A, modulus 0.30 MPa) and silicone hydrogel (galyfilcon A, 0.43 MPa) design of similar geometries (8.30-mm base curve, 14.0-mm diameter). RESULTS: The mean horizontal corneal diameter was 13.39 mm (SD ±0.44). In many cases, there was a tangential transition at the corneoscleral junction. The corneoscleral shape profile analyzed from cross-sectional OCT images contributed significantly (P < 0.001) to the prediction of soft contact lens fit compared with keratometry and videokeratoscopy, accounting for up to 24% of the variance in lens movement. The fit of the stiffer material silicone hydrogel lens was better able to be predicted and was more varied than the hydrogel contact lens. CONCLUSIONS: The extra peripheral corneoscleral data gained from OCT characterization of ocular surface architecture provide valuable insight into soft contact lens fit dynamics.


Assuntos
Lentes de Contato Hidrofílicas , Córnea/patologia , Topografia da Córnea , Miopia/reabilitação , Esclera/patologia , Adolescente , Adulto , Feminino , Seguimentos , Humanos , Masculino , Miopia/patologia , Miopia/fisiopatologia , Estudos Prospectivos , Ajuste de Prótese , Refração Ocular , Tomografia de Coerência Óptica , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...