Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Nucl Med ; 55(6): 917-22, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24762624

RESUMO

UNLABELLED: Transient ischemic dilation (TID) in the setting of abnormal stress-rest cardiac SPECT myocardial perfusion imaging (MPI) has been linked with increased cardiovascular risk. However, the significance of TID in the setting of an otherwise normal SPECT MPI study has not been clearly established. In this study, cardiac CT was used to evaluate the prevalence of atherosclerotic lesions and the severity of coronary artery stenosis in patients with TID of the left ventricle with or without associated myocardial perfusion defects on SPECT MPI. METHODS: The study population consisted of 1,553 consecutive patients who had undergone both cardiac CT and SPECT MPI within 1 mo between January 1, 2006, and September 1, 2011. Patients included in the study group had a pathologic TID value defined as ≥1.18 for men and ≥1.22 for women. Coronary CT angiography was used to evaluate each coronary segment for the presence and composition of atherosclerotic plaque and the degree of coronary stenosis. TID-positive patients were compared with a 2:1 risk-factor-matched-pair control cohort without TID. RESULTS: TID was identified in 30 patients who were compared with TID-negative risk-factor-matched controls (n = 60). When compared with the TID-negative control cohort, TID-positive patients had no significant differences in the presence and extent of atherosclerosis, the degree of coronary artery stenosis, or the calcium score at cardiac CT. Similarly, there were no significant differences in these CT measures in TID-positive patients with a normal perfusion study (n = 20) when compared with TID-negative patients with a normal perfusion study (n = 48). In addition, there was no significant difference in the incidence of major adverse cardiac events when comparing both the TID-positive patients and the TID-negative control cohort and when comparing patients who were TID-positive with normal perfusion with patients who were TID-negative with normal perfusion. CONCLUSION: The presence of TID with an otherwise normal SPECT MPI study does not translate into a greater extent of coronary artery disease as assessed by cardiac CT or increased risk for future major adverse cardiac events.


Assuntos
Angiografia Coronária , Ventrículos do Coração/diagnóstico por imagem , Isquemia Miocárdica/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
2.
Eur Radiol ; 23(3): 650-7, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22983281

RESUMO

OBJECTIVES: Performance evaluation of a fully automated system for calculating computed tomography (CT) coronary artery calcium scores from contrast medium-enhanced coronary CT angiography (cCTA) studies. METHODS: One hundred and twenty-seven patients (58 ± 11 years, 71 men) who had undergone cCTA as well as an unenhanced CT calcium scoring study where included. Calcium scores were computed from cCTA by an automated image processing algorithm and compared with calcium scores obtained by standard manual assessment of unenhanced CT calcium scoring studies. Results were compared vis-a-vis (1) absolute calcium score values, (2) age-, gender- and race-dependent percentiles, and (3) commonly used calcium score risk classification categories. RESULTS: One hundred and nineteen out of 127 (93.7%) studies were successfully processed. Mean Agatston calcium score values obtained by traditional non-contrast CT calcium scoring studies and derived from contrast medium-enhanced cCTA did not significantly differ (235.6 ± 430.5 vs 262.0 ± 499.5; P > 0.05). Calcium score risk categories and Multi-Ethnic Study of Atherosclerosis (MESA) percentiles showed very high correlation (Spearman rank correlation coefficient = 0.97, P < 0.0001/0.95, P < 0.0001) between the two approaches. CONCLUSIONS: Calcium score values automatically computed from cCTA are highly correlated with standard unenhanced CT calcium scoring studies. These results suggest a radiation dose- and time-saving potential when deriving calcium scores from cCTA studies without a preceding unenhanced CT calcium scoring study.


Assuntos
Algoritmos , Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Iohexol/análogos & derivados , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Calcinose/complicações , Meios de Contraste , Doença da Artéria Coronariana/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade
3.
Eur Radiol ; 23(1): 125-32, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22777622

RESUMO

OBJECTIVES: Comparison of coronary artery stent assessment with cardiac CT angiography (cCTA) using traditional filtered back projection (FBP) and sinogram affirmed iterative reconstruction (SAFIRE), in both full- and half-radiation dose image data. METHODS: Dual-source cCTA studies of 37 implanted stents were reconstructed at full- and half-radiation dose with FBP and SAFIRE. Half-dose data were based on projections from one DSCT detector. In-stent noise, signal-to-noise ratio (SNR), and stent-lumen attenuation increase ratio (SAIR) were measured and image quality graded. Stent volumes were measured to gauge severity of beam hardening artefacts. RESULTS: Full-dose SAFIRE reconstructions were superior to full-dose FBP vis-à-vis in-stent noise (21.2 ± 6.6 vs. 35.7 ± 17.5; P < 0.05), SNR (22.1 ± 8.6 vs. 14.3 ± 6.7; P < 0.05), SAIR (19.6 ± 17.6 vs. 33.4 ± 20.4%; P < 0.05), and image quality (4.2 ± 0.86 vs. 3.5 ± 1.0; P < 0.05). Stent volumes were lower measured with SAFIRE (119.9 ± 53.7 vs. 129.8 ± 65.0 mm(3); P > 0.05). Comparing half-dose SAFIRE with full-dose FBP, in-stent noise (26.7 ± 13.0 vs. 35.7 ± 17.5; P < 0.05) and SNR (18.2 ± 6.9 vs. 14.3 ± 6.7; P < 0.05) improved significantly. SAIR (31.6 ± 24.3 vs. 33.4 ± 20.4%; P > 0.05), stent volume (129.6 ± 57.3 vs. 129.8 ± 65.0 mm(3); P > 0.05), and image quality (3.5 ± 1.0 vs. 3.7 ± 1.1; P > 0.05) did not differ. Radiation dose decreased from 8.7 ± 5.2 to 4.3 ± 2.6 mSv. CONCLUSIONS: Iterative reconstruction significantly improves imaging of coronary artery stents by CT compared with FBP, even with half-radiation-dose data.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/cirurgia , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Stents , Tomografia Computadorizada por Raios X/métodos , Idoso , Artefatos , Distribuição de Qui-Quadrado , Comorbidade , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Estudos Retrospectivos , Razão Sinal-Ruído , Estatísticas não Paramétricas
4.
Cranio ; 23(1): 48-52, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15727321

RESUMO

Although it is commonly accepted that there is an interrelationship between the temporomandibular joint (TMJ) and head posture, few, if any, previous studies have quantified this effect. The purpose of this study is to quantify the effect of a change in the condyle fossa relationship of symptomatic temporomandibular joints on head posture. Charts of 51 patients (N=10 men and N=41 women) with symptomatic TMJ pathology were reviewed. The condyle fossa relationships were measured pre- and posttreatment using sagittal corrected hypocycloidal tomography. The amount of slant between the shoulder and external auditory meatus (EAM) was measured in pre- and posttreatment photographs as an indicator of forward head posture; less slant indicates better posture. Subjects ranged in age from 13-74 years (mean=43.1) and had been treated for an average of 5 months. Comparisons with pre-treatment measures showed that after treatment, the amount of retrodiskal space was significantly increased by an average of 1.67 mm on the left side (t=-10.11, p<0.0001) and 1.92 mm on the right (t=-9.62, p<0.0001). Comparisons also showed that after treatment, the amount of slant between the shoulder and EAM decreased by 4.43 inches on average which was also significant (t=13.08, p<0.0001). Improvement in the condyle fossa relationship was related to decreased forward head posture. This suggests that optimizing mandibular condyle position should be considered in the management of forward head posture (adaptive posture).


Assuntos
Cabeça/anatomia & histologia , Côndilo Mandibular/patologia , Osso Temporal/patologia , Transtornos da Articulação Temporomandibular/terapia , Articulação Temporomandibular/patologia , Adolescente , Adulto , Idoso , Meato Acústico Externo/patologia , Feminino , Seguimentos , Humanos , Masculino , Côndilo Mandibular/diagnóstico por imagem , Pessoa de Meia-Idade , Fotografação , Postura , Radiografia , Ombro/patologia , Osso Temporal/diagnóstico por imagem , Articulação Temporomandibular/diagnóstico por imagem , Disco da Articulação Temporomandibular/diagnóstico por imagem , Disco da Articulação Temporomandibular/patologia , Transtornos da Articulação Temporomandibular/diagnóstico por imagem , Tomografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...