Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cardiovasc Intervent Radiol ; 32(4): 615-22, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19387732

RESUMO

Complications of embolization and chemoembolization remain a problem even with the development of low-profile catheter material and the introduction of new embolization agents. In recent years many new embolization materials have become available for clinical use, so the possibilities and limitations of these new materials must be understood to allow safe and effective embolization. Although up to now some scientific work has been published reporting the basic risk of embolization procedures, the underlying pathomechanism remains the object of speculation. Besides complications like drug toxicity, allergic reactions, and bleeding of the puncture site, the characteristics of embolization materials must be known to understand the potential complications of nontarget embolization and reflux of embolization material. This article gives an overview of established and new embolization materials, their potential risks, and the underlying pathophysiology.


Assuntos
Embolização Terapêutica/efeitos adversos , Radiografia Intervencionista , Angiografia , Animais , Quimioembolização Terapêutica/efeitos adversos , Hemodinâmica , Humanos , Modelos Animais , Tamanho da Partícula , Seleção de Pacientes , Fatores de Risco
2.
J Clin Anesth ; 20(4): 300-3, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18617131

RESUMO

A 38-year-old woman who had familial adenomatous polyposis was admitted to the intensive care unit with an episode of severe sepsis 5 days after undergoing a pancreas-preserving duodenectomy. Laparotomy with removal of an intra-abdominal abscess, followed by closed postoperative continuous lavage for 10 days, was performed. During two courses of planned tracheal extubation, the patient developed an acute lung injury, making a reintubation necessary. In both events, the patient received small doses of continuous morphine before the extubation. Morphine may induce the development of an acute lung injury in patients, whereas the exact pathophysiologic and pharmacologic mechanisms remain unclear.


Assuntos
Lesão Pulmonar Aguda/induzido quimicamente , Analgésicos Opioides/efeitos adversos , Morfina/efeitos adversos , Lesão Pulmonar Aguda/diagnóstico por imagem , Lesão Pulmonar Aguda/fisiopatologia , Adulto , Duodeno/cirurgia , Feminino , Humanos , Intubação Intratraqueal , Radiografia , Sepse/microbiologia , Sepse/cirurgia , Resultado do Tratamento
3.
J Comput Assist Tomogr ; 29(1): 64-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15665685

RESUMO

OBJECTIVE: To evaluate the accuracy of multidetector computed tomography (CT) and magnetic resonance imaging (MRI) in staging and estimating renal carcinomas with caval thrombus. METHODS: Initially, 23 patients with suspected caval thrombi were admitted into this prospective study. Triphasic CT imaging was performed using a multidetector CT with a reconstructed slice thickness of 2 mm. 3D CT reconstructions were used to improve surgical planning. MRI protocol included: a transversal T1-weighted GE sequence with and without Gd-DTPA, a transversal T2-weighted respiratory-gated TSE, and a coronal T1-weighted GE sequence with Gd-DTPA and fat saturation. In addition, a multiphase 3D angiography was performed after Gd-DTPA injection. Patients were divided into 3 groups: caval thrombus below the insertion of the hepatic veins, within the intrahepatic vena cava, and intra-atrial extension. The results the tumor thrombus extension and staging results of 2 independent readers were correlated with surgical and histopathological staging. RESULTS: Of the 23 patients admitted, CT and MR scans of 14/13 patients respectively were correlated with histopathological workup. CT thrombus detection sensitivity and specificity for both readers was 0.93 and 0.8 respectively. MRI sensitivity and specificity for both readers was 1.0/0.85 and 0.75. Readers I and II evaluated the uppermost extension of the cranial tumor thrombus by both CT and MRI. CT and MR accuracy was 78% and 72%, 88% and 76% respectively. CONCLUSION: In cases of a suspected tumor thrombus, MRI and multidetector CT imaging showed similar staging results. Consequently, these staging modalities can be used to assess the extension of the tumor thrombus.


Assuntos
Carcinoma de Células Renais/diagnóstico , Iohexol/análogos & derivados , Neoplasias Renais/diagnóstico , Imageamento por Ressonância Magnética , Células Neoplásicas Circulantes/patologia , Tomografia Computadorizada Espiral , Veia Cava Inferior/patologia , Trombose Venosa/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos , Intensificação de Imagem Radiográfica , Sensibilidade e Especificidade , Veia Cava Inferior/diagnóstico por imagem , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/patologia
4.
J Comput Assist Tomogr ; 28(3): 333-9, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15100536

RESUMO

OBJECTIVE: The aim of this prospective study is to compare the diagnostic accuracy of multidetector-row computed tomography (CT) and magnetic resonance imaging (MRI) in tumor staging of renal cell carcinomas. METHODS: In a prospective study, 82 renal cell carcinomas were assessed for tumor staging before surgery using multidetector-row CT and MRI, the results of which were then correlated to histopathologic staging. Triphasic CT (noncontrast, arterial phase, and parenchymal phase) imaging was performed using multidetector-row CT with a reconstructed slice thickness of 2 mm. In MRI, a transverse T1-weighted gradient echo sequence with and without administration of Gd-DTPA, a transverse T2-weighted respiratory-gated turbo spin echo (TSE) sequence, and a coronal T1-weighted gradient echo sequence with Gd-DTPA were used. In addition, multiphasic 3-dimensional angiography after Gd-DTPA injection and a transverse T1-weighted fat-suppression sequence were performed. RESULTS: With MRI, readers 1 and 2 correctly staged 71 and 64 tumors (overall accuracy of 0.87 and 0.78, respectively) and achieved Mantel-Haenszel chi(2) values of 66 and 63 (P < 0.0001). Computed tomography allowed correct staging of 68 and 66 tumors (readers 1 and 2, overall accuracy of 0.83 and 0.80, respectively) with Mantel-Haenszel chi(2) values of 54 and 54 for CT staging (P < 0.0001). No statistically significant difference between overall accuracy was found in the chi(2) test (P > 0.15). CONCLUSION: Magnetic resonance imaging and multidetector-row CT with its multiplanar reconstruction capabilities achieve similar accuracy in tumor staging of renal cell carcinomas.


Assuntos
Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
5.
J Comput Assist Tomogr ; 27(6): 864-8, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14600451

RESUMO

OBJECTIVE: To compare maximum spatial resolution in multislice computed tomography (MS-CT) and digital subtraction angiography (DSA) using an arterial tree model for canine kidney specimens. METHODS: Twenty-three isolated fox terrier kidneys were catheterized with a 4F catheter and underwent contrast-enhanced MS-CT with a maximum spatial resolution of 0.23-mm isotropic voxel size in an early arterial phase. In addition, a digital subtraction angiogram was performed on all kidneys. The kidneys were segmented semiautomatically, and each parenchymal vessel that was identified in the kidney was marked. The maximum intensity projections of arterial vessels in the CT datasets were evaluated in a comparison with the DSA datasets. RESULTS: No significant difference in vessel delineation and count was found at any level up to the fourth level of intrarenal branching. CONCLUSION: MS-CT has the potential of replacing DSA in the diagnosis of intrarenal arteries.


Assuntos
Angiografia Digital/métodos , Rim/irrigação sanguínea , Artéria Renal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Animais , Cães
6.
AJR Am J Roentgenol ; 178(2): 481-6, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11804922

RESUMO

OBJECTIVE: The objective of this study was to compare clinical chest radiographs of a large-area, flat-panel digital radiography system and a conventional film-screen radiography system. The comparison was based on an observer preference study of image quality and visibility of anatomic structures. MATERIALS AND METHODS: Routine follow-up chest radiographs were obtained from 100 consecutive oncology patients using a large-area, amorphous silicon flat-panel detector digital radiography system (dose equivalent to a 400-speed film system). Hard-copy images were compared with previous examinations of the same individuals taken on a conventional film-screen system (200-speed). Patients were excluded if changes in the chest anatomy were detected or if the time interval between the examinations exceeded 1 year. Observer preference was evaluated for the image quality and the visibility of 15 anatomic structures using a five-point scale. RESULTS: Dose measurements with a chest phantom showed a dose reduction of approximately 50% with the digital radiography system compared with the film-screen radiography system. The image quality and the visibility of all but one anatomic structure of the images obtained with the digital flat-panel detector system were rated significantly superior (p < or = 0.0003) to those obtained with the conventional film-screen radiography system. CONCLUSION: The image quality and visibility of anatomic structures on the images obtained by the flat-panel detector system were perceived as equal or superior to the images from conventional film-screen chest radiography. This was true even though the radiation dose was reduced approximately 50% with the digital flat-panel detector system.


Assuntos
Radiografia Torácica/instrumentação , Radiografia Torácica/normas , Humanos , Intensificação de Imagem Radiográfica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...