Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Public Health ; 11: 1168551, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37727605

RESUMO

Standard multiplex RT-qPCR diagnostic tests use nasopharyngeal swabs to simultaneously detect a variety of infections, but commercially available kits can be expensive and have limited throughput. Previously, we clinically validated a saliva-based RT-qPCR diagnostic test for SARS-CoV-2 to provide low-cost testing with high throughput and low turnaround time on a university campus. Here, we developed a respiratory diagnostic panel to detect SARS-CoV-2, influenza A and B within a single saliva sample. When compared to clinical results, our assay demonstrated 93.5% accuracy for influenza A samples (43/46 concordant results) with no effect on SARS-CoV-2 accuracy or limit of detection. In addition, our assay can detect simulated coinfections at varying virus concentrations generated from synthetic RNA controls. We also confirmed the stability of influenza A in saliva at room temperature for up to 5 days. The cost of the assay is lower than standard nasopharyngeal swab respiratory panel tests as saliva collection does not require specialized swabs or trained clinical personnel. By repurposing the lab infrastructure developed for the COVID-19 pandemic, our multiplex assay can be used to provide expanded access to respiratory disease diagnostics, especially for community, school, or university testing applications where saliva testing was effectively utilized during the COVID-19 pandemic.


Assuntos
COVID-19 , Doenças Transmissíveis , Influenza Humana , Humanos , SARS-CoV-2 , Universidades , COVID-19/diagnóstico , COVID-19/epidemiologia , Pandemias
2.
Microbiol Spectr ; 10(3): e0079722, 2022 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-35546574

RESUMO

SARS-CoV-2 variants of concern (VOCs) continue to pose a public health threat which necessitates a real-time monitoring strategy to complement whole genome sequencing. Thus, we investigated the efficacy of competitive probe RT-qPCR assays for six mutation sites identified in SARS-CoV-2 VOCs and, after validating the assays with synthetic RNA, performed these assays on positive saliva samples. When compared with whole genome sequence results, the SΔ69-70 and ORF1aΔ3675-3677 assays demonstrated 93.60 and 68.00% accuracy, respectively. The SNP assays (K417T, E484K, E484Q, L452R) demonstrated 99.20, 96.40, 99.60, and 96.80% accuracies, respectively. Lastly, we screened 345 positive saliva samples from 7 to 22 December 2021 using Omicron-specific mutation assays and were able to quickly identify rapid spread of Omicron in Upstate South Carolina. Our workflow demonstrates a novel approach for low-cost, real-time population screening of VOCs. IMPORTANCE SARS-CoV-2 variants of concern and their many sublineages can be characterized by mutations present within their genetic sequences. These mutations can provide selective advantages such as increased transmissibility and antibody evasion, which influences public health recommendations such as mask mandates, quarantine requirements, and treatment regimens. Our RT-qPCR workflow allows for strain identification of SARS-CoV-2 positive saliva samples by targeting common mutation sites shared between variants of concern and detecting single nucleotides present at the targeted location. This differential diagnostic system can quickly and effectively identify a wide array of SARS-CoV-2 strains, which can provide more informed public health surveillance strategies in the future.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , Mutação , RNA Viral/análise , RNA Viral/genética , SARS-CoV-2/genética , Saliva
3.
Front Public Health ; 10: 858421, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35450120

RESUMO

By developing a partnership amongst a public university lab, local city government officials and community healthcare providers, we established a drive-through COVID-19 testing site aiming to improve access to SARS-CoV-2 testing in rural Upstate South Carolina. We collected information on symptoms and known exposures of individuals seeking testing to determine the number of pre- or asymptomatic individuals. We completed 71,102 SARS-CoV-2 tests in the community between December 2020-December 2021 and reported 91.49% of results within 24 h. We successfully identified 5,244 positive tests; 73.36% of these tests originated from individuals who did not report symptoms. Finally, we identified high transmission levels during two major surges and compared test positivity rates of the local and regional communities. Importantly, the local community had significantly lower test positivity rates than the regional community throughout 2021 (p < 0.001). While both communities reached peak case load and test positivity near the same time, the local community returned to moderate transmission as indicated by positivity 4 weeks before the regional community. Our university lab facilitated easy testing with fast turnaround times, which encouraged voluntary testing and helped identify a large number of non-symptomatic cases. Finding the balance of simplicity, accessibility, and community trust was vital to the success of our widespread community testing program for SARS-CoV-2.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , COVID-19/epidemiologia , Teste para COVID-19 , Técnicas e Procedimentos Diagnósticos , Humanos , População Rural , South Carolina
4.
medRxiv ; 2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-35262087

RESUMO

SARS-CoV-2 variants of concern (VOCs) continue to pose a public health threat which necessitates a real-time monitoring strategy to compliment whole genome sequencing. Thus, we investigated the efficacy of competitive probe RT-qPCR assays for six mutation sites identified in SARS-CoV-2 VOCs and, after validating the assays with synthetic RNA, performed these assays on positive saliva samples. When compared with whole genome sequence results, the SΔ69-70 and ORF1aΔ3675-3677 assays demonstrated 93.60% and 68.00% accuracy, respectively. The SNP assays (K417T, E484K, E484Q, L452R) demonstrated 99.20%, 96.40%, 99.60%, and 96.80% accuracies, respectively. Lastly, we screened 345 positive saliva samples from December 7-22, 2021 using Omicron-specific mutation assays and were able to quickly identify rapid spread of Omicron in Upstate South Carolina. Our workflow demonstrates a novel approach for low-cost, real-time population screening of VOCs. Importance: SARS-CoV-2 variants of concern and their many sublineages can be characterized by mutations present within their genetic sequences. These mutations can provide selective advantages such as increased transmissibility and antibody evasion, which influences public health recommendations such as mask mandates, quarantine requirements, and treatment regimens. Our real-time RT-qPCR workflow allows for strain identification of SARS-CoV-2 positive saliva samples by targeting common mutation sites shared between VOCs and detecting single nucleotides present at the targeted location. This differential diagnostic system can quickly and effectively identify a wide array of SARS-CoV-2 strains, which can provide more informed public health surveillance strategies in the future.

5.
J Vis Exp ; (180)2022 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-35225290

RESUMO

The emergence of the recent SARS-CoV-2 global health crisis introduced key challenges for epidemiological research and clinical testing. Characterized by a high rate of transmission and low mortality, the COVID-19 pandemic necessitated accurate and efficient diagnostic testing, particularly in closed populations such as residential universities. Initial availability of nucleic acid testing, like nasopharyngeal swabs, was limited due to supply chain pressure which also delayed reporting of test results. Saliva-based reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) testing has shown to be comparable in sensitivity and specificity to other testing methods, and saliva collection is less physically invasive to participants. Consequently, we developed a multiplex RT-qPCR diagnostic assay for population surveillance of Clemson University and the surrounding community. The assay utilized open-source liquid handling robots and thermocyclers instead of complex clinical automation systems to optimize workflow and system flexibility. Automation of saliva-based RT-qPCR enables rapid and accurate detection of a wide range of viral RNA concentrations for both large- and small-scale testing demands. The average turnaround for the automated system was < 9 h for 95% of samples and < 24 h for 99% of samples. The cost for a single test was $2.80 when all reagents were purchased in bulk quantities.


Assuntos
COVID-19 , Robótica , COVID-19/diagnóstico , Teste de Ácido Nucleico para COVID-19 , Humanos , Nasofaringe , Pandemias , RNA Viral/análise , RNA Viral/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa , SARS-CoV-2/genética , Saliva/química , Sensibilidade e Especificidade , Manejo de Espécimes/métodos
7.
Diabetes Care ; 32(1): 184-6, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18835943

RESUMO

OBJECTIVE: To determine whether, in accordance with observations in mouse models, high concentrations of the lipoprotein lipase inhibitors apolipoprotein (Apo) CI and ApoCIII are associated with increased triglyceride concentrations and decreased fat mass in men with the metabolic syndrome. RESEARCH DESIGN AND METHODS: Plasma ApoCI, ApoCIII, and triglyceride concentrations were measured in the postabsorptive state in 98 men with the metabolic syndrome. Subcutaneous and visceral fat areas were measured by 3T-magnetic resonance imaging. RESULTS: Triglyceride concentrations were 49% higher, and the average visceral fat area was 26% lower (both P < 0.001), in subjects with high ApoCI and ApoCIII compared with low ApoCI and ApoCIII. Subjects with either high ApoCI or ApoCIII had 16% (P < 0.05) and 18% (P < 0.01) decreased visceral fat area, respectively. CONCLUSIONS: High concentrations of ApoCI and ApoCIII are associated with increased triglycerides and decreased visceral fat mass in men with the metabolic syndrome. These findings translate mouse studies into human pathophysiology.


Assuntos
Tecido Adiposo/patologia , Apolipoproteína C-III/sangue , Apolipoproteína C-I/sangue , Síndrome Metabólica/sangue , Triglicerídeos/sangue , Idoso , Humanos , Imageamento por Ressonância Magnética , Masculino , Síndrome Metabólica/patologia , Pessoa de Meia-Idade , Seleção de Pacientes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...