Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Prog ; 106(4): 368504231215942, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38031343

RESUMO

The ceramic-polymer composite materials are widely known for their exceptional mechanical and biological properties. Polycaprolactone (PCL) is a biodegradable polymer material extensively used in various biomedical applications. At the same time, barium titanate (BT), a ceramic material, exhibits piezoelectric properties similar to bone, which is essential for osseointegration. Furthermore, a composite material that combines the benefits of PCL and BT results in an innovative composite material with enhanced properties for biomedical applications. Thus, this review is organised into three sections. Firstly, it aims to provide an overview of the current research on evaluating biological properties, including antibacterial activity, cytotoxicity and osseointegration, of PCL polymeric matrices in its pure form and reinforced structures with ceramics, polymers and natural extracts. The second section investigates the biological properties of BT, both in its pure form and in combination with other supporting materials. Finally, the third section provides a summary of the biological properties of the PCLBT composite material. Furthermore, the existing challenges of PCL, BT and their composites, along with future research directions, have been presented. Therefore, this review will provide a state-of-the-art understanding of the biological properties of PCL and BT composites as potential futuristic materials in biomedical applications.


Assuntos
Materiais Biocompatíveis , Poliésteres , Materiais Biocompatíveis/química , Bário , Poliésteres/química , Polímeros/química
2.
F1000Res ; 12: 385, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37663198

RESUMO

Background: Maxillofacial silicones are the most popular and acceptable material for making maxillofacial prostheses, but they are not perfect in every sense. To enhance their effectiveness, more improvements to their properties are required, such as their antimicrobial efficiency. This study assess the antibacterial effect of barium titanate nanoparticles in various percentages against staphylococcus epidermidis biofilm adhesion after addition to maxillofacial silicone. Methods: Barium titanate nanoparticles were added into VST-50 platinum silicone elastomer in four weight percentages (0.25wt%, 0.5wt%, 0.75wt% and 1wt%). 50 specimens were prepared and categorized into five groups; one control group and four experimental groups. All conducted data was statistically analyzed using (one-way ANOVA) analysis of variance, and Games-Howell multiple comparison test (significant level at p < 0.05). Shapiro-Wilk and Levene's tests were used, respectively, to evaluate the normal distribution and homogeneity of the data. Result: One-way ANOVA test revealed a highly significant difference between all groups, and Games-Howell test revealed a highly significant difference between the control group and the four experimental groups. The 0.25wt% and 0.5wt% groups revealed a highly significant difference between them and with the (0.75%wt and 0.1%wt) groups. While the 0.75wt% group revealed a significant difference with 1wt% group. Conclusions: The addition of barium titanate to VST-50 maxillofacial silicone enhanced the antibacterial activity of silicon against Staphylococcus epidermidis, and this activity seems to be concentration dependent. FTIR analysis demonstrated no chemical interaction between the Barium Titanate and the VST-50 maxillofacial silicone elastomer. SEM pictures show that the barium titanate nanopowder was effectively dispersed inside the maxillofacial silicone matrix.


Assuntos
Nanopartículas , Elastômeros de Silicone , Elastômeros de Silicone/química , Bário , Staphylococcus epidermidis , Antibacterianos/farmacologia
3.
Int J Biomater ; 2022: 8722283, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35992052

RESUMO

Background: Implant insertion in regions with poor bone quantity, such as the posterior maxilla, is potentially associated with an increased rate of implant failure. Calcium sulfate can be used as the coating material for commercially pure titanium (CpTi) and as the bone graft material around implants when bound to eggshell powder to enhance the bone quality and quantity of bone defect regions. This study performed a torque removal test to evaluate the effectiveness of eggshell powder as a bone substitute for filling bone defects around CpTi-coated implants coated with nanocrystalline calcium sulfate. Materials and Methods: Eighty screw implant designs were used in the tibiae of 20 white New Zealand rabbits. A total of uncoated 20 screws constituted the control group, and the remaining 60 screws coated with nano calcium sulfate nanoparticles were used as the experimental groups as follows: 20 screws coated with nano calcium sulfate were used alone in the tibiae without gaps around them, 20 screws coated with nano calcium sulfate were used with the gaps made around them and filled with eggshell powder as the bone graft material, and 20 screws coated with nano calcium sulfate were used with the gaps made around them left unfilled. Results: After 2 to 6 weeks of healing, a significant improvement in bone regeneration and an increase in torque removal values were observed when the bone defect around the CpTi implant coated with nano calcium sulfate was filled with eggshell powder as the bone substitute. Conclusions: Nano calcium sulfate particles applied through the dip-coating method can successfully work as the coating material of CpTi implants. These particles work in synergy with eggshell powder to act as the bone graft around the implants.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...