1.
Water Res ; 83: 112-20, 2015 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-26141427

RESUMO

The potential of recirculating aquaculture systems (RAS) in the aquaculture industry is increasingly being acknowledged. Along with intensified application, the need to better characterise and understand the accumulated dissolved organic matter (DOM) within these systems increases. Mature RASs, stocked with rainbow trout and operated at steady state at four feed loadings, were analysed by dissolved organic carbon (DOC) analysis and fluorescence excitation-emission matrix (EEM) spectroscopy. The fluorescence dataset was then decomposed by PARAFAC analysis using the drEEM toolbox. This revealed that the fluorescence character of the RAS water could be represented by five components, of which four have previously been identified in fresh water, coastal marine water, wetlands and drinking water. The fluorescence components as well as the DOC showed positive correlations with feed loading, however there was considerable variation between the five fluorescence components with respect to the degree of accumulation with feed loading. The five components were found to originate from three sources: the feed; the influent tap water (groundwater); and processes related to the fish and the water treatment system. This paper details the first application of fluorescence EEM spectroscopy to assess DOM in RAS, and highlights the potential applications of this technique within future RAS management strategies.


Assuntos
Aquicultura , Monitoramento Ambiental/métodos , Substâncias Húmicas/análise , Poluentes Químicos da Água/análise , Purificação da Água , Análise Fatorial , Espectrometria de Fluorescência
2.
Water Res ; 44(18): 5323-33, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20655084

RESUMO

Dual distribution systems are becoming increasingly common in greenfield housing developments in Australia for the redistribution of recycled water to households for non-potable use. Within such schemes there exists the potential for cross-connections between recycled and drinking water systems. Due to the high level of recycled water treatment, these events are unlikely to lead to outbreaks of illness in the community. Nonetheless, they do represent a breach of the recycled water risk management strategy and therefore an elevated level of risk to consumers. Furthermore, cross-connection events have the potential to undermine public confidence in these types of water recycling. A rapid, highly sensitive method of cross-connection detection may therefore provide an additional level of confidence in these schemes. The aim of this research was to determine the potential for using fluorescence spectroscopy as a monitoring tool in water treatment plants and dual distribution systems. Samples from both the water recycling plant and dual distribution system were collected on a weekly basis over 12 weeks. Fluorescence excitation-emission matrix (EEM) spectra and water quality parameters including dissolved organic carbon, UV(254), pH, conductivity, free chlorine and turbidity were obtained for each sample. The fluorescence EEM spectra of recycled and drinking water were distinctly different and exhibited low variability throughout the course of the sampling program, indicating a degree of stability of the fluorescent components within the organic matter. A ten-fold difference in mean fluorescence intensity was observed for recycled water compared to drinking water, which was greater than the difference observed for the other measured water quality parameters. Probabilistic analysis was used to determine the reliable detection limit of recycled water contamination of drinking water. Accounting for the inherent variability of both recycled water and drinking water, a 45% contamination of recycled water in drinking water could be detected with a signal-to-noise ratio greater than 3 for more than 95% of individual random sample pairs. Greater sensitivity can be assured by averaging numerous samples. In comparison, a 70% contamination of recycled water in drinking water was required for the same detection using conductivity.


Assuntos
Monitoramento Ambiental/métodos , Reciclagem , Purificação da Água/métodos , Abastecimento de Água/análise , Austrália , Condutividade Elétrica , Limite de Detecção , Espectrometria de Fluorescência , Água/normas , Poluentes Químicos da Água/análise
3.
Water Sci Technol ; 61(1): 155-62, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20057101

RESUMO

A rapid, highly sensitive method for detection of cross-connections between recycled and potable water in dual reticulation systems is required. The aim of this research was to determine the potential of fluorescence spectroscopy as a monitoring tool at three Australian dual distribution (drinking and recycled water) systems. Weekly grab samples of recycled and potable water were obtained over 12 weeks at each site and analysed for fluorescence excitation-emission matrix (EEM) spectroscopy, UV(254), dissolved organic carbon (DOC), electrical conductivity and pH. Fluorescence EEM spectroscopy was able to differentiate between recycled and potable water at each site by monitoring the protein-like fluorescence at peak T-an excitation-emission wavelength pair of lambda(ex/em) = 300/350 nm. While electrical conductivity was also able to distinguish between recycled and potable water, the differentiation was greatest when using fluorescence. For example, the peak T fluorescence in recycled water was up to 10 times that of potable water in comparison with electrical conductivity that had a maximum 5 times differentiation. Furthermore, by comparing the protein-like fluorescence at peak T and humic-like fluorescence at peak A (lambda(ex/em) = 235/426 nm), the three different recycled water systems were able to be differentiated. Overall, fluorescence shows promise as a monitoring tool for detecting cross-connections.


Assuntos
Conservação dos Recursos Naturais/métodos , Monitoramento Ambiental/métodos , Poluentes Químicos da Água/análise , Austrália , Carbono/análise , Condutividade Elétrica , Humanos , Compostos Orgânicos/análise , Proteínas/análise , Saúde Pública/normas , Espectrometria de Fluorescência/métodos , Espectrofotometria Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...