Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
Int J Oral Maxillofac Implants ; 32(2): 322-328, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28291850

RESUMO

PURPOSE: The prevalence of peri-implant infection in patients with dental implants has been shown to range from 28% to 56%. A nanotube-modified implant surface can deliver antibiotics locally and suppress periodontal pathogenic bacterial growth. The aim of this study was to evaluate the deliverability of antibiotics via a nanotube-modified implant. MATERIALS AND METHODS: Dental implants with a nanotube surface were fabricated and loaded with doxycycline. Afterward, each dental implant with a nanotube surface was placed into 2-mL tubes, removed from solution, and placed in a fresh solution daily for 28 days. Experimental samples from 1, 2, 4, 16, 24, and 28 days were used for this evaluation. The concentration of doxycycline was measured using spectrophotometric analysis at 273-nm absorbance. The antibacterial effect of doxycycline was evaluated by supplementing Porphyromonas gingivalis (P gingivalis) growth media with the solution collected from the dental implants at the aforementioned time intervals for a period of 48 hours under anaerobic conditions. A bacterial viability assay was used to evaluate P gingivalis growth at 550-nm absorbance. RESULTS: Doxycycline concentration varied from 0.33 to 1.22 µg/mL from day 1 to day 28, respectively. A bacterial viability assay showed the highest P gingivalis growth at day 1 (2 nm) and the lowest at day 4 (0.17 nm), with a gradual reduction from day 1 to day 4 of approximately 87.5%. The subsequent growth pattern was maintained and slightly increased from baseline in approximately 48.3% from day 1 to day 24. The final P gingivalis growth measured at day 28 was 29.4% less than the baseline growth. CONCLUSION: P gingivalis growth was suppressed in media supplemented with solution collected from dental implants with a nanotube surface loaded with doxycycline during a 28-day time interval.


Assuntos
Antibacterianos/farmacologia , Implantes Dentários/microbiologia , Doxiciclina/farmacologia , Sistemas de Liberação de Medicamentos/métodos , Nanotubos , Porphyromonas gingivalis/efeitos dos fármacos , Descontaminação/métodos , Relação Dose-Resposta a Droga , Humanos , Periodontite/prevenção & controle , Porphyromonas gingivalis/crescimento & desenvolvimento , Propriedades de Superfície
2.
Mater Sci Eng C Mater Biol Appl ; 59: 677-689, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26652422

RESUMO

The negative impact of in vivo corrosion of metallic biomedical implants remains a complex problem in the medical field. We aimed to determine the effects of electrochemical anodization (60V, 2h) and thermal oxidation (600°C) on the corrosive behavior of Ti-6Al-4V, with serum proteins, at physiological temperature. Anodization produced a mixture of anatase and amorphous TiO2 nanopores and nanotubes, while the annealing process yielded an anatase/rutile mixture of TiO2 nanopores and nanotubes. The surface area was analyzed by the Brunauer-Emmett-Teller method and was estimated to be 3 orders of magnitude higher than that of polished control samples. Corrosion resistance was evaluated on the parameters of open circuit potential, corrosion potential, corrosion current density, passivation current density, polarization resistance and equivalent circuit modeling. Samples both anodized and thermally oxidized exhibited shifts of open circuit potential and corrosion potential in the noble direction, indicating a more stable nanoporous/nanotube layer, as well as lower corrosion current densities and passivation current densities than the smooth control. They also showed increased polarization resistance and diffusion limited charge transfer within the bulk oxide layer. The treatment groups studied can be ordered from greatest corrosion resistance to least as Anodized+Thermally Oxidized > Anodized > Smooth > Thermally Oxidized for the conditions investigated. This study concludes that anodized surface has a potential to prevent long term implant failure due to corrosion in a complex in-vivo environment.


Assuntos
Temperatura Alta , Nanotubos/química , Titânio/química , Ligas , Corrosão , Falha de Prótese
3.
J Oral Implantol ; 41(5): 523-31, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24628292

RESUMO

Traditionally, titanium oxide (TiO2) nanotubes (TNTs) are anodized on Ti-6Al-4V alloy (Ti-V) surfaces with native TiO2 (amorphous TiO2); subsequent heat treatment of anodized surfaces has been observed to enhance cellular response. As-is bulk Ti-V, however, is often subjected to heat treatment, such as thermal oxidation (TO), to improve its mechanical properties. Thermal oxidation treatment of Ti-V at temperatures greater than 200°C and 400°C initiates the formation of anatase and rutile TiO2, respectively, which can affect TNT formation. This study aims at understanding the TNT formation mechanism on Ti-V surfaces with TO-formed TiO2 compared with that on as-is Ti-V surfaces with native oxide. Thermal oxidation-formed TiO2 can affect TNT formation and surface wettability because TO-formed TiO2 is expected to be part of the TNT structure. Surface characterization was carried out with field emission scanning electron microscopy, energy dispersive x-ray spectroscopy, water contact angle measurements, and white light interferometry. The TNTs were formed on control and 300°C and 600°C TO-treated Ti-V samples, and significant differences in TNT lengths and surface morphology were observed. No difference in elemental composition was found. Thermal oxidation and TO/anodization treatments produced hydrophilic surfaces, while hydrophobic behavior was observed over time (aging) for all samples. Reduced hydrophobic behavior was observed for TO/anodized samples when compared with control, control/anodized, and TO-treated samples. A method for improved surface wettability and TNT morphology is therefore discussed for possible applications in effective osseointegration of dental and orthopedic implants.


Assuntos
Nanotubos , Osseointegração , Titânio , Microscopia Eletrônica de Varredura , Óxidos , Propriedades de Superfície
4.
Biomaterials ; 35(37): 9951-9962, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25224369

RESUMO

Cerium oxide (CeO2) nanoparticles have been posited to exhibit potent anti-oxidant activity which may allow for the use of these materials in biomedical applications. Herein, we investigate whether CeO2 nanoparticle administration can diminish right ventricular (RV) hypertrophy following four weeks of monocrotaline (MCT)-induced pulmonary arterial hypertension (PAH). Male Sprague Dawley rats were randomly divided into three groups: control, MCT only (60 mg/kg), or MCT + CeO2 nanoparticle treatment (60 mg/kg; 0.1 mg/kg). Compared to the control group, the RV weight to body weight ratio was 45% and 22% higher in the MCT and MCT + CeO2 groups, respectively (p < 0.05). Doppler echocardiography demonstrated that CeO2 nanoparticle treatment attenuated monocrotaline-induced changes in pulmonary flow and RV wall thickness. Paralleling these changes in cardiac function, CeO2 nanoparticle treatment also diminished MCT-induced increases in right ventricular (RV) cardiomyocyte cross sectional area, ß-myosin heavy chain, fibronectin expression, protein nitrosylation, protein carbonylation and cardiac superoxide levels. These changes with treatment were accompanied by a decrease in the ratio of Bax/Bcl2, diminished caspase-3 activation and reduction in serum inflammatory markers. Taken together, these data suggest that CeO2 nanoparticle administration may attenuate the hypertrophic response of the heart following PAH.


Assuntos
Antioxidantes/uso terapêutico , Cério/uso terapêutico , Hipertensão Pulmonar/induzido quimicamente , Hipertensão Pulmonar/complicações , Hipertrofia Ventricular Direita/tratamento farmacológico , Hipertrofia Ventricular Direita/etiologia , Nanopartículas/uso terapêutico , Animais , Ventrículos do Coração/efeitos dos fármacos , Ventrículos do Coração/patologia , Hipertrofia Ventricular Direita/patologia , Masculino , Monocrotalina , Nanopartículas/ultraestrutura , Ratos , Ratos Sprague-Dawley
5.
Int J Nanomedicine ; 9: 3737-48, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25143725

RESUMO

After the implantation of a biomaterial in the body, the first interaction occurs between the cells in contact with the biomaterial surface. Therefore, evaluating the cell-substrate interface is crucial for designing a successful implant. In this study, the interaction of MC3T3 osteoblasts was studied on commercially pure and alloy (Ti6Al4V) Ti surfaces treated with amorphous and crystalline titanium dioxide nanotubes. The results indicated that the presence of nanotubes increased the density of osteoblast cells in comparison to bare surfaces (no nanotubes). More importantly, our finding shows that the chemistry of the substrate affects the cell density rather than the morphology of the cells. A novel approach based on the focused ion beam technique was used to investigate the biophysical cell-substrate interaction. The analysis revealed that portions of the cells migrated inside the crystalline nanotubes. This observation was correlated with the super hydrophilic properties of the crystalline nanotubes.


Assuntos
Materiais Biocompatíveis/química , Nanotubos/química , Osteoblastos/citologia , Titânio/química , Animais , Adesão Celular/fisiologia , Linhagem Celular , Camundongos , Propriedades de Superfície
6.
PLoS One ; 9(5): e96213, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24788345

RESUMO

The primary objective of this study was to fabricate a TiO2 nanotubular surface, which could maintain hydrophilicity over time (resist aging). In order to achieve non-aging hydrophilic surfaces, anodization and annealing conditions were optimized. This is the first study to show that anodization and annealing condition affect the stability of surface hydrophilicity. Our results indicate that maintenance of hydrophilicity of the obtained TiO2 nanotubes was affected by anodization voltage and annealing temperature. Annealing sharply decreased the water contact angle (WCA) of the as-synthesized TiO2 nanotubular surface, which was correlated to improved hydrophilicity. TiO2 nanotubular surfaces are transformed to hydrophilic surfaces after annealing, regardless of annealing and anodization conditions; however, WCA measurements during aging demonstrate that surface hydrophilicity of non-anodized and 20 V anodized samples decreased after only 11 days of aging, while the 60 V anodized samples maintained their hydrophilicity over the same time period. The nanotubes obtained by 60 V anodization followed by 600 °C annealing maintained their hydrophilicity significantly longer than nanotubes which were obtained by 60 V anodization followed by 300 °C annealing.


Assuntos
Ligas/química , Materiais Biocompatíveis/química , Nanotubos/química , Titânio/química , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Eletrodos , Temperatura Alta , Interações Hidrofóbicas e Hidrofílicas , Interferometria/métodos , Microscopia Eletrônica de Varredura/métodos , Nanotubos/ultraestrutura , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície , Fatores de Tempo , Água/química
7.
J Mater Chem B ; 2(23): 3597-3608, 2014 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-32263796

RESUMO

Modifications of Ti-6Al-4V surface roughness, wettability and composition are increasingly studied to improve cellular viability on biomedical implants involving Ti-6Al-4V. In this study, it is shown that modification of Ti-6Al-4V samples using anodization (for the formation of titania nanotubes) combined with thermal oxidation (TO) results in superior surface characteristics to those of a smooth, rough, anodized-smooth or anodized-rough surface alone. Surface characterization is performed using water contact angle (WCA) measurements, white-light interferometry, Fourier transform infrared spectroscopy (FTIRS), field emission scanning electron microscopy and grazing incidence X-ray diffraction (GIXRD). WCA measurements before TO indicate that anodized-smooth and anodized-rough samples are super-hydrophilic (WCA less than 5°); WCA of non-anodized smooth and rough surfaces are 57 ± 6° and 86 ± 7°, respectively. After TO at 450 °C for 3 hours, all samples become super-hydrophilic; however, three weeks after TO, smooth and rough surfaces become hydrophobic, while anodized-smooth and anodized-rough surfaces remain hydrophilic. FTIRS and GIXRD data show that the TO of anodized and non-anodized smooth samples results in anatase and rutile TiO2, of which anatase is favorable for cellular attachment. Micro-/nano-scale roughness and TO are discussed in the context of enhanced Ti-6Al-4V surface characteristics for improved cellular response.

8.
Biomatter ; 1(1): 91-101, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-23507731

RESUMO

In this research, new bioactive nanocomposite scaffolds were successfully developed using poly(ε-caprolactone) (PCL), cross-linked gelatin and nanoparticles of hydroxyapatite (HAp) after testing different solvents and methods. First, HAp powder was synthesized via a chemical precipitation technique and characterized. Then, the nanocomposites were prepared through layer solvent casting combined with freeze-drying and lamination techniques. According to the results, the increasing of the PCL weight in the scaffolds led to the improvement of the mechanical properties. The amount of ultimate stress, stiffness and also elastic modulus increased from 8 MPa for 0% wt PCL to 23.5 MPa for 50% wt PCL. The biomineralization study revealed the formation of an apatite layer on the scaffolds after immersion in simulated body fluid (SBF). The Ca-P ratios were in accordance to nonstoichiometric biological apatite, which was approximately 1.67. The in vitro biocompatibility and cytocompatibility of the scaffolds were tested using mesenchymal stem cells (MSCs), and the results indicated no sign of toxicity, and cells were found to be attached to the scaffold walls. The in vivo biocompatibility and osteogenesis of these scaffolds in the animal experiments is also under investigation, and the result will be published at the end of the study.


Assuntos
Substitutos Ósseos/química , Durapatita/química , Gelatina/química , Nanocompostos/química , Poliésteres/química , Engenharia Tecidual/métodos , Animais , Apatitas , Líquidos Corporais , Proliferação de Células , Humanos , Células-Tronco Mesenquimais/citologia , Microscopia Eletrônica de Varredura , Pós , Pressão , Coelhos , Solventes/química , Espectroscopia de Infravermelho com Transformada de Fourier , Estresse Mecânico , Fatores de Tempo , Alicerces Teciduais , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...