Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Ann R Coll Surg Engl ; 102(5): 383-390, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32233869

RESUMO

INTRODUCTION: Cardiopulmonary exercise testing (CPET) and transthoracic echocardiography (TTE) are common preparative investigations prior to elective endovascular aneurysm repair (EVAR). Whether these investigations can predict survival following EVAR and contribute to shared decision making is unknown. METHODS: Patients who underwent EVAR at a tertiary centre between June 2007 and December 2014 were identified from the National Vascular Registry. Variables obtained from preoperative investigations were assessed for their association with survival at three years. Regression analysis was used to determine variables that independently predicted survival at three years. RESULTS: A total of 199 patients underwent EVAR during the study period. Of these, 120 had preoperative CPET and 123 had TTE. Lower forced expiratory ventilation (FEV1), ratio of FEV1 to forced vital capacity, work at peak oxygen consumption and higher ventilatory equivalent for carbon dioxide were associated with increased mortality. Variables obtained from TTE were not associated with survival at three years although there was a low incidence of left ventricular systolic dysfunction and significant valvular disease in this cohort. CONCLUSIONS: CPET might be a useful adjunct to assist in shared decision making in patients undergoing elective EVAR and may influence anaesthetic technique. TTE does not appear to be able to discriminate between high and low risk individuals. However, a low rate of significant ventricular dysfunction and valvular disease in patients undergoing elective EVAR may account for these findings.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Teste de Esforço , Complicações Pós-Operatórias/prevenção & controle , Cuidados Pré-Operatórios/métodos , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/mortalidade , Ecocardiografia , Procedimentos Cirúrgicos Eletivos/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Guias de Prática Clínica como Assunto , Valor Preditivo dos Testes , Cuidados Pré-Operatórios/normas , Sistema de Registros/estatística & dados numéricos , Medição de Risco/métodos , Medição de Risco/normas , Fatores de Risco , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento
2.
Clin Radiol ; 74(6): 429-434, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30846190

RESUMO

AIM: To provide an update of current practice in iliac artery intervention in the UK. MATERIALS AND METHODS: Ninety-nine interventional units across the UK completed online submission forms for iliac angioplasty and stent procedures between 2011 and 2014 (inclusive) for the British Iliac Angioplasty and Stenting (BIAS) IV registry. RESULTS: Data for 8,294 procedures were submitted during the study period. A total of 12,253 iliac segments were treated in 10,311 legs. The commonest indication was claudication (n=5219, 64.4%). Of the cases performed, 6,582 (80.8%) were performed electively with 3,548 (44.8%) of the procedures performed as a day-case and 6,586 (54%) of the lesions were treated with stents. Successful endovascular intervention (residual stenosis ≤49%) was achieved in 11,847 (97%) of treated segments, with residual stenosis in 1.5%. One point five percent of lesions could not be crossed with a wire. Limb complications were recorded in 366 (3.5%), resulting in 141 patients undergoing an unplanned intervention and 173 (2.2%) patients had a systemic complication. There were 84 deaths prior to discharge, of which 13 (15%) were procedure related. Both systemic and limb complication rates were higher in patients undergoing treatment for critical ischaemia. CONCLUSION: Iliac stenting and angioplasty are associated with high technical success with a low complication rate. These data provide up-to-date statistics for patient information and future audit and benchmarking purposes.


Assuntos
Angioplastia/métodos , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/terapia , Artéria Ilíaca/diagnóstico por imagem , Radiologia Intervencionista/métodos , Sistema de Registros , Stents , Humanos , Resultado do Tratamento , Reino Unido
3.
Br J Surg ; 106(4): 367-374, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30706453

RESUMO

BACKGROUND: The effect of sarcopenia based on the total psoas muscle area (TPMA) on CT is inconclusive in patients undergoing abdominal aortic aneurysm (AAA) intervention. The aim of this prospective cohort study was to evaluate morphometric sarcopenia as a method of risk stratification in patients undergoing elective AAA intervention. METHODS: TPMA was measured on preintervention CT images of patients undergoing elective endovascular aneurysm repair (EVAR) or open aneurysm repair. Mortality was assessed in relation to preintervention TPMA using Cox regression analysis, with calculation of hazard ratios at 30 days, 1 year and 4 years. Postintervention morbidity was evaluated in terms of postintervention care, duration of hospital stay and 30-day readmission. Changes in TPMA on surveillance EVAR imaging were also evaluated. RESULTS: In total, 382 patient images acquired between March 2008 and December 2016 were analysed. There were no significant intraobserver and interobserver differences in measurements of TPMA. Preintervention TPMA failed to predict morbidity and mortality at all time points. The mean(s.d.) interval between preintervention and surveillance imaging was 361·3(111·2) days. A significant reduction in TPMA was observed in men on surveillance imaging after EVAR (mean reduction 0·63(1·43) cm2 per m2 ; P < 0·001). However, this was not associated with mortality (adjusted hazard ratio 1·00, 95 per cent c.i. 0·99 to 1·01; P = 0·935). CONCLUSION: TPMA is not a suitable risk stratification tool for patients undergoing effective intervention for AAA.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Procedimentos Cirúrgicos Eletivos/métodos , Procedimentos Endovasculares/métodos , Músculos Psoas/diagnóstico por imagem , Sarcopenia/diagnóstico por imagem , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Estudos de Coortes , Procedimentos Cirúrgicos Eletivos/mortalidade , Procedimentos Endovasculares/mortalidade , Feminino , Mortalidade Hospitalar/tendências , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos , Análise de Regressão , Análise de Sobrevida , Resultado do Tratamento
4.
Clin Radiol ; 73(9): 800-809, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29921442

RESUMO

AIM: To ascertain current percutaneous lung biopsy practices around the UK. MATERIALS AND METHODS: A web-based survey was sent to all British Society of Thoracic Imaging (BSTI) and British Society of Interventional Radiology (BSIR) members (May 2017) assessing all aspects of lung biopsy practice. Responses were collected anonymously. RESULTS: Two hundred and thirty-nine completed responses were received (28.8% response rate). Of the respondents, 48.5% worked in a teaching hospital and 51.5% in a district general hospital, while 32.6% (78/239) were specialist thoracic radiologists, 29.2% (70/239) "general" radiologists with a thoracic subspecialty interest, and 28% (67/239) interventional radiologists. Of the respondents, 30.1% (72/239) did not require pre-biopsy lung function tests (PFTs); 45.6% (108/237) stopped aspirin before the procedure; 97.5% primarily use computed tomography (CT) guidance for biopsy and 88.7% (212/239) perform core needle biopsy (CNB); and 86.6% of radiologists use a co-axial technique. There was wide variation in the number of samples routinely taken with most radiologists performing 1-2 passes (55.9%) or 3-4 passes (40.8%). Sixty-four percent reported using chest drain prevention techniques to minimise the impact of iatrogenic pneumothorax, with needle aspiration most frequent (43.9%). Timing of post-biopsy chest radiography (CXR), performed by 95.8% (228/239), also varied greatly: most commonly at either 1 hour (23%), 2 hours (24.7%), or 4 hours (22.6%). Moreover, the time of patient discharge after uncomplicated biopsy was variable, although the majority (66.1%) discharge patients after ≥4 hours. CONCLUSION: There are striking variations among surveyed UK radiologists performing lung biopsy in decision-making, pre-biopsy work-up, post-biopsy monitoring, management of pneumothorax, and discharge. The results suggest a need for new updated national percutaneous lung biopsy guidelines.


Assuntos
Biópsia por Agulha/métodos , Biópsia Guiada por Imagem/métodos , Neoplasias Pulmonares/patologia , Padrões de Prática Médica/estatística & dados numéricos , Radiografia Intervencionista/métodos , Biópsia por Agulha/efeitos adversos , Tomada de Decisões , Detecção Precoce de Câncer , Feminino , Humanos , Biópsia Guiada por Imagem/efeitos adversos , Masculino , Pessoa de Meia-Idade , Radiografia Torácica/métodos , Inquéritos e Questionários , Reino Unido
5.
Eye (Lond) ; 29(10): 1270-84, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26337943

RESUMO

Glaucoma is a neurodegenerative disorder with established relationships with ocular structures such as the retinal nerve fibre layer (RNFL) and the ganglion cell layer (GCL). Ocular imaging techniques such as optical coherence tomography (OCT) allow for quantitative measurement of these structures. OCT has been used in the monitoring of glaucoma, as well as investigating other neurodegenerative conditions such as Alzheimer's disease (AD) and multiple sclerosis (MS). In this review, we highlight the association between these disorders and ocular structures (RNFL and GCL), examining their usefulness as biomarkers of neurodegeneration. The average RNFL thickness loss in patients with AD is 11 µm, and 7 µm in MS patients. Most of the studies investigating these changes are cross-sectional. Further longitudinal studies are required to assess sensitivity and specificity of these potential ocular biomarkers to neurodegenerative disease progression.


Assuntos
Doença de Alzheimer/fisiopatologia , Glaucoma/fisiopatologia , Esclerose Múltipla/fisiopatologia , Fibras Nervosas/patologia , Doenças Neurodegenerativas/fisiopatologia , Células Ganglionares da Retina/patologia , Doença de Alzheimer/diagnóstico , Biomarcadores , Glaucoma/diagnóstico , Humanos , Esclerose Múltipla/diagnóstico , Doenças Neurodegenerativas/diagnóstico
7.
Mol Psychiatry ; 17(11): 1116-29, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21876539

RESUMO

Coffee consumption is a model for addictive behavior. We performed a meta-analysis of genome-wide association studies (GWASs) on coffee intake from 8 Caucasian cohorts (N=18 176) and sought replication of our top findings in a further 7929 individuals. We also performed a gene expression analysis treating different cell lines with caffeine. Genome-wide significant association was observed for two single-nucleotide polymorphisms (SNPs) in the 15q24 region. The two SNPs rs2470893 and rs2472297 (P-values=1.6 × 10(-11) and 2.7 × 10(-11)), which were also in strong linkage disequilibrium (r(2)=0.7) with each other, lie in the 23-kb long commonly shared 5' flanking region between CYP1A1 and CYP1A2 genes. CYP1A1 was found to be downregulated in lymphoblastoid cell lines treated with caffeine. CYP1A1 is known to metabolize polycyclic aromatic hydrocarbons, which are important constituents of coffee, whereas CYP1A2 is involved in the primary metabolism of caffeine. Significant evidence of association was also detected at rs382140 (P-value=3.9 × 10(-09)) near NRCAM-a gene implicated in vulnerability to addiction, and at another independent hit rs6495122 (P-value=7.1 × 10(-09))-an SNP associated with blood pressure-in the 15q24 region near the gene ULK3, in the meta-analysis of discovery and replication cohorts. Our results from GWASs and expression analysis also strongly implicate CAB39L in coffee drinking. Pathway analysis of differentially expressed genes revealed significantly enriched ubiquitin proteasome (P-value=2.2 × 10(-05)) and Parkinson's disease pathways (P-value=3.6 × 10(-05)).


Assuntos
Moléculas de Adesão Celular/genética , Café/genética , Citocromo P-450 CYP1A1/genética , Citocromo P-450 CYP1A2/genética , Ingestão de Líquidos/genética , Estudo de Associação Genômica Ampla/métodos , Antígenos de Neoplasias/genética , Proteínas Reguladoras de Apoptose/genética , Cafeína/farmacologia , Linhagem Celular , Feminino , Expressão Gênica/efeitos dos fármacos , Perfilação da Expressão Gênica/métodos , Predisposição Genética para Doença/genética , Humanos , Masculino , Doença de Parkinson/genética , Polimorfismo de Nucleotídeo Único , Proteínas Serina-Treonina Quinases/genética , População Branca/genética
8.
Int J Obstet Anesth ; 20(4): 282-7, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21852107

RESUMO

BACKGROUND: Placenta praevia and accreta are leading causes of major obstetric haemorrhage and peripartum hysterectomy. Detection is largely based on a high index of clinical suspicion, though the diagnostic accuracy of radiological imaging is improving. Interventional radiological techniques can reduce blood loss and the incidence of hysterectomy. METHODS: We have reviewed our experience with bilateral prophylactic uterine artery balloon occlusion in the management of women with suspected placenta accreta. Thirteen women at high risk of major haemorrhage due to placenta praevia or suspected placenta accreta were retrospectively studied. Uterine artery balloons were placed prophylactically under neuraxial anaesthesia in the angiography suite followed by caesarean delivery in the obstetric operating theatre. RESULTS: Intraoperative blood loss and transfusion requirements were low in our case series. There were no hysterectomies or admissions to the intensive care unit. Fetal bradycardia necessitating immediate caesarean delivery occurred in two women (15.4%). CONCLUSION: In our case series in women with suspected placenta accreta, prophylactic use of uterine artery balloons was associated with a low requirement for blood transfusion but with possible increased risk of fetal compromise. Performing the interventional procedure at a different site from the operative room complicated management.


Assuntos
Oclusão com Balão/métodos , Placenta Acreta/terapia , Adulto , Transfusão de Sangue , Feminino , Humanos , Imageamento por Ressonância Magnética , Gravidez , Estudos Retrospectivos , Artéria Uterina
9.
Eur J Vasc Endovasc Surg ; 42(5): 608-14, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21852165

RESUMO

OBJECTIVES: The United Kingdom abdominal aortic aneurysm (AAA) screening programme refers aneurysms with ultrasound (US) diameters of ≥5.5 cm to vascular services for consideration of computed tomography (CT) and intervention. We investigated the discrepancy between US and CT, implications on clinical decisions and question at which stage CT be used. DESIGN/METHODS: AAA USs over 5 years were retrospectively analysed. Patients included had aneurysms measuring ≥5 cm on US with subsequent CT within 2 months (n = 123). Based on maximum US diameters, 44 patients had aneurysms between 5 and 5.4 cm (group I) and 79 patients ≥5.5 cm (group II). Results were cross-referenced. Correlation and limits of agreement were calculated. Two radiologists re-measured 44 pairs of CT/US scans and the inter-observer bias in determining discrepancies between imaging modalities calculated. RESULTS: Mean difference between imaging modalities was 0.21 cm (±0.39 cm, p < 0.001). Limits of agreement were -0.55 to 0.96 cm, exceeding clinical acceptability. Mean difference was higher and significant in group I (0.39 cm, p < 0.001) compared to group II (0.10 cm, p > 0.05). Seventy-percent of group I patients had CT scans revealing diameters of ≥5.5 cm. Inter-observer bias was not significant. CONCLUSION: Significant differences between imaging modalities, more in US diameters of below 5.5 cm, exist. We recommend AAAs measuring ≥5 cm on US should undergo earlier referral to a vascular service and CT.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Aneurisma da Aorta Abdominal/terapia , Aortografia , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Seleção de Pacientes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Ultrassonografia
10.
Eye (Lond) ; 24(7): 1165-70, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20150923

RESUMO

PURPOSE: The purpose of this study was to compare the reliability of the 'gold standard' Goldmann applanation tonometer (GAT), with that of the ocular response analyser (ORA), and the dynamic contour tonometer (DCT). PATIENTS AND METHODS: A total of 694 subjects were recruited to participate from the TwinsUK (UK Adult Twin Registry) at St Thomas' Hospital, London. Intraocular pressure (IOP) was measured using GAT, ORA, and the DCT. The agreement between the three methods was assessed using the Bland-Altman method. Repeatability coefficients and coefficient of variation between first and second readings of the same eye were used to assess reliability. RESULTS: Mean age was 57.5 years (SD, 13.1; range, 16.1-88.5). The mean IOPs, calculated using the mean of two readings from the right eye were as follows: Goldmann (GAT), 14.1+/-2.8 mm Hg; IOPg (ORA), 15.9+/-3.2 mm Hg; IOPcc (ORA), 16.6+/-3.2 mm Hg; and DCT, 16.9+/-2.7 mm Hg. The 95% limits of agreement were for ORA (IOPcc): GAT, -2.07 to 7.18 mm Hg; for DCT: GAT, -0.49 to 6.21 mm Hg; and for DCT: ORA (IOPcc), -3.01 to 4.85 mm Hg. Coefficients of variation for the three tonometers were GAT, 8.3%; ORA, 8.2%; DCT, 6.3%. The repeatability coefficients were 3.4 mm Hg for GAT, 3.57 mm Hg for ORA and 3.09 mm Hg for DCT. GAT and ORA (IOPg) readings showed a positive correlation with central corneal thickness (P<0.005). CONCLUSIONS: This study found similar reliability in all three tonometers. Bland-Altman plots showed the three instruments to have 95% limits of agreement outside the generally accepted limits, which means they are not interchangeable. GAT measurements were found to be significantly lower than the two newer instruments.


Assuntos
Pressão Intraocular , Tonometria Ocular/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/diagnóstico , Reprodutibilidade dos Testes , Gêmeos , Adulto Jovem
12.
Clin Radiol ; 64(5): 502-10, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19348846

RESUMO

AIM: To audit the use of inferior vena cava (IVC) filter insertions at three UK centres over 12 years to assess whether trends in filter use in the UK mirrored those seen elsewhere. MATERIALS AND METHODS: Radiology department databases were interrogated for IVC filter insertions and removals between 1994 and 2006. Reports for these interventions, along with prior and subsequent imaging reports, were analysed. Follow-up data were obtained when available. RESULTS: Five hundred and sixteen filters were placed with a significant year-on-year trend towards increasing use. Fifty-seven percent of filters placed were for absolute indications and 37% for relative indications. The filters were used for prophylaxis in 6% of patients in the absence of proven pulmonary embolism (PE) or deep vein thrombosis (DVT). A retrievable filter was used in 74% of cases with retrieval attempted in 40% of these and no evidence of an increasing rate of retrieval over time. A significant complication related to insertion or retrieval was encountered in 0.4 and 1% of procedures, respectively. Mean 24 h and 30 day mortalities were 1 and 8%, respectively. There was an absence of organized follow-up at all three centres. CONCLUSION: IVC filter use in the UK is increasing. The use of retrievable filters has not resulted in increased filter retrieval. Filter insertion and retrieval is associated with a low risk of significant complication, but lack of systematic follow-up limits conclusions regarding safety and efficacy.


Assuntos
Remoção de Dispositivo/estatística & dados numéricos , Filtros de Veia Cava/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Tomada de Decisões , Remoção de Dispositivo/mortalidade , Remoção de Dispositivo/tendências , Feminino , Humanos , Masculino , Auditoria Médica , Pessoa de Meia-Idade , Implantação de Prótese/efeitos adversos , Implantação de Prótese/mortalidade , Implantação de Prótese/tendências , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/prevenção & controle , Radiografia , Resultado do Tratamento , Reino Unido , Filtros de Veia Cava/efeitos adversos , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/prevenção & controle , Adulto Jovem
13.
Br J Ophthalmol ; 92(8): 1125-8, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18653607

RESUMO

AIMS: To estimate the heritability of intraocular pressure (IOP) by performing a classical twin study and to determine whether the use of different instruments influences calculation of eye IOP heritability. METHODS: Twin pairs were recruited to participate from the TwinsUK Adult Twin Registry at St. Thomas' Hospital London. IOP was measured using Goldmann applanation tonometry (GAT). A subset of twins also had their IOP measured using the Ocular Response Analyser (ORA; Reichert, Buffalo, NY) and the Dynamic Contour Tonometer (DCT, Pascal; Swiss Microtechnology AG, Port, Switzerland). We compared the covariance of IOP within monozygotic (MZ) and dizygotic (DZ) pairs using genetic modelling techniques to determine the relative contribution of genes and environment to the variation in IOP seen in this population. RESULTS: Data for 422 twin pairs (211 MZ; 211 DZ) were analysed. The mean IOP for GAT was 15.4 (SD 2.7) mm Hg (range: 8.7-26.2 mm Hg). The MZ correlations were significantly higher than DZ for IOP measured by GAT, DCT and ORA (correlation coefficients: GAT: 0.57:0.39, DCT: 0.62:0.36, Goldmann-correlated ORA (IOPg) 0.73:0.47, for MZ:DZ twins, respectively). Modelling suggested heritability for GAT IOP of 0.62, with individual environmental factors accounting for 0.38 of the variation. CONCLUSION: This study demonstrated that genetic effects are important in determining IOP in this twin population. IOP readings differed depending upon the instrument used, and this resulted in different heritability values; genetic factors explained 62%, 63% and 74% of the variation in IOP using GAT, DCT and ORA IOPg, respectively. Environmental factors determined the remainder of the variation.


Assuntos
Pressão Intraocular/genética , Gêmeos Dizigóticos/genética , Gêmeos Monozigóticos/genética , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Reprodutibilidade dos Testes , Tonometria Ocular/instrumentação , Tonometria Ocular/métodos
14.
Eur J Vasc Endovasc Surg ; 35(4): 405-12, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18262445

RESUMO

OBJECTIVES: Modern conventional ultrasound is sensitive to slow flow, but may misclassify some tight stenoses as occlusion. Symptomatic patients with tight proximal internal carotid artery stenoses may benefit from carotid endarterectomy but those with occlusion or long-segment disease do not. DESIGN: A prospective study of the diagnostic accuracy of contrast-enhanced ultrasound (CE-US), 2D time-of-flight magnetic resonance angiography (2D-TOF MRA) and contrast-enhanced magnetic resonance angiography (CE-MRA) against a reference standard of digital subtraction angiography (DSA) in patients with apparent carotid occlusion on conventional ultrasound. MATERIALS AND METHODS: Thirty-one patients with apparent carotid occlusion on conventional ultrasound and with recent ispilateral hemispheric transient ischaemeic attacks (TIAs) were studied. The primary endpoint was confirmation of occlusion with a secondary endpoint of identification of a surgically correctible lesion. RESULTS: The sensitivity and specificity of CE-US, 2D-TOF MRA and CE-MRA for patency were 1 & 1, 0.33 & 1 and 0.6 & 1 respectively and for the detection of a surgically correctible lesion were 1 & 0.96, 0.67 & 1 and 1 and 0.96 respectively. CE-US was difficult to interpret, precluding confident diagnosis in 5 cases. CONCLUSIONS: 2D-TOF MRA had poor sensitivity for patency and cannot be recommended as a second-line investigation to assess vessels apparently occluded on conventional ultrasound. Confident diagnosis on CE-US and CE-MRA accurately identified occlusion. If occlusion is confirmed by either of these modalities, no further imaging is required. The relative advantages of CE-US or CE-MRA in this situation are uncertain.


Assuntos
Artéria Carótida Interna , Estenose das Carótidas/diagnóstico , Angiografia por Ressonância Magnética , Ultrassonografia Doppler em Cores , Estenose das Carótidas/fisiopatologia , Estenose das Carótidas/terapia , Meios de Contraste , Endarterectomia das Carótidas , Humanos , Seleção de Pacientes , Estudos Prospectivos , Sensibilidade e Especificidade , Grau de Desobstrução Vascular/fisiologia
16.
Eye (Lond) ; 22(7): 935-8, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17363925

RESUMO

PURPOSE: To compare the accuracy of the Hoffer Q and SRK-T formulae in eyes below 22 mm in axial length, using biometry measured with partial coherence inferometry (PCI), without a customised ACD constant. METHODS: Data were retrospectively and prospectively collected by identifying eyes of axial length below 22 mm in the records of the intraocular lens (IOL) master and in preoperative notes. Biometry was performed using PCI and IOL power was calculated using both SRK-T and Hoffer Q formulae. Refractive outcome was measured and the accuracy of the two formulae compared. RESULTS: Forty-one eyes of 41 patients were identified with an axial length <22 mm. Axial lengths ranged from 21.96 to 20.29 with a mean of 21.51 mm, and IOL power ranging from 23 dioptres (D) to 29 D. The Hoffer Q formula showed a mean prediction error of 0.61 D (SD 0.80) compared with the SRK-T, which showed a mean prediction error of 0.87 D (SD 0.829). A paired t-test found that the Hoffer Q was significantly more accurate than the SRK-T formula (P<0.001). CONCLUSIONS: Hoffer Q was found to be more accurate than the SRK-T formula in this series of eyes <22 mm axial length when customised ACD constants are not used. Royal College of Ophthalmologists guidelines may need to be adjusted in accordance with these findings. This study underlines the importance of monitoring outcomes, and suggests different customisations are needed for different formulae, with a higher correction if the SRK-T formula is used for short eyes.


Assuntos
Olho/patologia , Hiperopia/patologia , Lentes Intraoculares , Biometria/métodos , Técnicas de Diagnóstico Oftalmológico , Humanos , Interferometria , Implante de Lente Intraocular , Modelos Biológicos , Facoemulsificação , Guias de Prática Clínica como Assunto , Estudos Prospectivos , Refração Ocular , Estudos Retrospectivos , Resultado do Tratamento
17.
Emerg Radiol ; 15(4): 277-80, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17876617

RESUMO

We present a case in which direct visualisation of the nature and extent of a perineal soft tissue injury following pelvic trauma was achieved through the use of multi-modality and multi-planar imaging. The case emphasises the importance of a flexible approach to imaging as a problem-solving technique after severe pelvic trauma.


Assuntos
Acidentes de Trânsito , Fraturas Ósseas/complicações , Ossos Pélvicos/lesões , Períneo/lesões , Adulto , Meios de Contraste , Fraturas Ósseas/diagnóstico , Fraturas Ósseas/etiologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Tomografia Computadorizada por Raios X
18.
Med Hypotheses ; 69(1): 113-6, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17196758

RESUMO

Major theories about the etiologies of chronic mental illnesses such as bipolar disorder and schizophrenia include genetic and environmental factors such as famine and infection. It is likely that multiple genes play a role in the pathogenesis of these disorders, but no single gene has been identified as causative. Several viruses have been investigated as potential candidates, but conflicting reports exist. Although a relationship between bipolar disorder and schizophrenia with autoimmune disorders has also been documented for many years, reports are often conflicting. We hypothesize that parvovirus B19 (B19), a common human pathogen, due to its ability to infect the brain and induce autoimmunity, is a strong candidate that may unite prevailing theories. In particular, our preliminary data suggest that B19 may be most likely involved in co-morbid bipolar and autoimmune thyroid disorders in females. In schizophrenics, the gender trend may be reversed. We propose that there is a complex interaction between immuno-genetics, autoimmunity, gender, and B19 infection that leads to at least some forms of bipolar disorder and schizophrenia. Future studies that investigate this hypothesis are warranted and outlined.


Assuntos
Encefalite Viral/virologia , Transtornos Mentais/virologia , Infecções por Parvoviridae/virologia , Parvovirus B19 Humano , Tireoidite Autoimune/virologia , Adulto , Encéfalo/virologia , Encefalite Viral/complicações , Feminino , Humanos , Masculino , Transtornos Mentais/complicações , Pessoa de Meia-Idade , Modelos Biológicos , Infecções por Parvoviridae/complicações , Fatores Sexuais , Tireoidite Autoimune/complicações
20.
Br J Ophthalmol ; 89(11): 1427-32, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16234446

RESUMO

AIMS: To evaluate the test-retest variability of stereometric parameter measurements made with the Heidelberg retina tomograph (HRT) and Heidelberg retina tomograph-II (HRT-II), and to establish which parameter(s) provided the most repeatable and reliable measurements with both devices. An investigation into the factors affecting the repeatability of the measurements of this parameter(s) was conducted. METHODS: 43 ocular hypertensive and 31 glaucoma subjects were recruited to a test-retest study. One eye from each subject underwent HRT and HRT-II imaging by two observers on each of two occasions within 6 weeks of each other. Lens grading was carried out by LOCS III grading and Scheimpflug camera generated densitogram analysis. RESULTS: Rim area (RA) and mean cup depth measurements were found to be least variable. Both inter-test reference height difference and image quality had a strong relation (R(2)>0.5, p<0.0001) with inter-test RA difference and, together, are responsible for 70% of RA measurement variability. Image quality was influenced by lens opacity, cylindrical error, and age. Inter-test RA measurement differences were unrelated to the observer or visit interval. CONCLUSIONS: RA represents an appropriate measure for monitoring glaucomatous progression. Reference height difference and image quality were the factors that most influenced RA measurement variability. Image analysis strategies that address these factors may reduce test-retest variability.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico , Tomografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Técnicas de Diagnóstico Oftalmológico , Feminino , Glaucoma de Ângulo Aberto/patologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Disco Óptico/patologia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...