1.
J Hazard Mater ; 192(3): 1380-7, 2011 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-21807459

RESUMO

The kinetic rate of dechlorination of a polychlorinated biphenyl (PCB-151) by mechanically alloyed Mg/Pd was studied for optimization of the bimetallic system. Bimetal production was first carried out in a small-scale environment using a SPEX 8000M high-energy ball mill with 4-µm-magnesium and palladium impregnated on graphite, with optimized parameters including milling time and Pd-loading. A 5.57-g sample of bimetal containing 0.1257% Pd and ball milled for 3 min resulted in a degradation rate of 0.00176 min(-1)g(-1) catalyst as the most reactive bimetal. The process was then scaled-up, using a Red Devil 5400 Twin-Arm Paint Shaker, fitted with custom plates to hold milling canisters. Optimization parameters tested included milling time, number of ball bearings used, Pd-loading, and total bimetal mass milled. An 85-g sample of bimetal containing 0.1059% Pd and ball-milled for 23 min with 16 ball bearings yielded the most reactive bimetal with a degradation rate of 0.00122 min(-1)g(-1) catalyst. Further testing showed adsorption did not hinder extraction efficiency and that dechlorination products were only seen when using the bimetallic system, as opposed to any of its single components. The bimetallic system was also tested for its ability to degrade a second PCB congener, PCB-45, and a PCB mixture (Arochlor 1254); both contaminants were seen to degrade successfully.


Assuntos
Ligas/química , Magnésio/análise , Paládio/análise , Bifenilos Policlorados/análise , Catálise , Recuperação e Remediação Ambiental/métodos , Desenho de Equipamento , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cinética , Metais/química , Microscopia Eletrônica de Varredura/métodos , Paládio/química , Estresse Mecânico , Fatores de Tempo
3.
Microb Drug Resist ; 15(2): 133-8, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19432517

RESUMO

Isolates of Salmonella enterica serovar Typhimurium belonging to definitive phage type (DT) 120 (Salmonella Typhimurium DT 120) from simultaneous outbreaks of infection in the England and Denmark have been compared on the basis of antibiogram, pulsed-field gel electrophoresis (PFGE), and multiple locus variable number tandem repeat analysis (MLVA). Isolates from England had the resistance profile (ampicillin, streptomycin, sulfamethoxazole, and tetracycline), MLVA profiles 2-4-4-0-2, 2-4-5-0-2, and 2-4-0-0-2, and the PFGE type STYMXB.0083. Representative isolates from the Denmark outbreak were resistant to ampicillin only (A) and had the MLVA type 2-12-6-0-2 and the PFGE type STYMXB.0010. These results demonstrated that outbreak isolates from England and Denmark were not identical. Subsequently, comparison of outbreak isolates with contemporary animal isolates showed that an isolate with the same PFGE type and a similar MLVA type had been isolated in England before its identification in Denmark. These results confirmed the usefulness of MLVA in international outbreak investigations of multiresistant Salmonella Typhimurium and have demonstrated how new molecular strategies may be used to supplement existing methods such as PFGE to enable the accurate and rapid comparison of isolates from different countries. The data also indicate that MLVA proves a useful method for detection of specific Salmonella Typhimurium DTs from human and veterinary sources.


Assuntos
Surtos de Doenças , Farmacorresistência Bacteriana Múltipla/genética , Salmonelose Animal/microbiologia , Salmonella typhimurium/efeitos dos fármacos , Salmonella typhimurium/genética , Animais , Antibacterianos/farmacologia , Bovinos , DNA Bacteriano/análise , DNA Bacteriano/genética , Dinamarca/epidemiologia , Cães , Eletroforese em Gel de Campo Pulsado , Inglaterra/epidemiologia , Humanos , Testes de Sensibilidade Microbiana , Salmonelose Animal/tratamento farmacológico , Salmonelose Animal/transmissão , Salmonella typhimurium/isolamento & purificação , Especificidade da Espécie , Suínos , Sequências de Repetição em Tandem , Perus
4.
Foodborne Pathog Dis ; 5(5): 661-8, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18851676

RESUMO

Salmonella Senftenberg is uncommon in the United Kingdom. In January-June 2007, the Health Protection Agency reported on 55 primary human cases of Salmonella Senftenberg in England and Wales. In May 2007, fresh basil sold in the United Kingdom was found to be contaminated with Salmonella Senftenberg. We launched an investigation to elucidate the cause of this outbreak. Isolates were examined using plasmid profiling and pulsed-field gel electrophoresis, and the outbreak strain (SSFTXB.0014) was identified. We enquired via Enter-net whether other countries had isolated the outbreak strain, analyzed samples of fresh herbs from U.K. retailers, and interviewed patients on food history. Thirty-two patient-cases were referred to this outbreak in England and Wales. Onsets of illness occurred between 5 March and 6 June 2007. Fifty-six percent of patient-cases were females and 90% adults (>20 years old); three were admitted to hospital as a result of Salmonella infection. Scotland, Denmark, the Netherlands, and the United States reported on 19 cases of Salmonella Senftenberg infection presenting with the outbreak strain since January 2007. Eight samples of prepacked fresh basil imported from Israel tested positive with the same strain. A minority of patients could recall the consumption of basil before illness, and some reported consumption of products where basil was a likely ingredient. Environmental investigations in Israel did not identify the contamination source. Microbiological evidence suggested an association between contamination of fresh basil and the cases of Salmonella Senftenberg infection, leading to withdrawal of basil from all potentially affected batches from the U.K. market.


Assuntos
Surtos de Doenças , Microbiologia de Alimentos , Ocimum/microbiologia , Intoxicação Alimentar por Salmonella/epidemiologia , Intoxicação Alimentar por Salmonella/etiologia , Adulto , Técnicas de Tipagem Bacteriana , Eletroforese em Gel de Campo Pulsado , Inglaterra/epidemiologia , Feminino , Manipulação de Alimentos , Humanos , Incidência , Cooperação Internacional , Israel , Masculino , Plasmídeos , Vigilância da População , Intoxicação Alimentar por Salmonella/microbiologia , Salmonella enterica/classificação , Salmonella enterica/isolamento & purificação , País de Gales/epidemiologia
5.
Microsc Microanal ; 7(5): 418-423, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12597804

RESUMO

Micrometer sized particles have been studied to show that a high-quality transmission electron microscope (TEM) specimen can be produced, without the use of embedding media, from a site-specific region of chosen particles using the focused ion beam (FIB) lift-out (LO) technique. The uniqueness of this technique is that site-specific TEM LO specimens may be obtained from particles and from regions which are smaller than the conventional approximately 10-20 &mgr;m x 5 &mgr;m x approximately 0.1 &mgr;m dimensions of the LO specimen. The innovative FIB LO procedures are described in detail and TEM images of electron transparent specimens obtained from specific micrometer-sized particles are presented.