Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Orthop Surg Res ; 19(1): 259, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38659060

RESUMO

PURPOSE: The purpose of the study was to describe a novel growth guidance system, which can avoid metal debris and reduce the sliding friction forces, and test the durability and glidability of the system by in vitro test. METHOD: Two major modifications were made to the traditional Shilla system, including the use of ultra-high molecular weight polyethylene (UHMWPE) gaskets to avoid direct contact between the screw and rod, and polishing the surface of the sliding part of the rod. We tested the durability of the system by a fatigue test, which the samples were test on the MTS system for a 10 million cycle of a constant displacement. Pre and post-testing involved weighing the UHMWPE gaskets and observing the wear conditions. The sliding ability were measured by a sliding displacement test. The maximum sliding displacement of the system was measured after a 300 cycles of dynamic compressive loads in a sinusoidal waveform. RESULTS: After the fatigue test, all the UHMWPE gaskets samples showed some of the fretting on the edge of the inner sides, but its still isolated and avoided the friction between the screws and rods. There was no production of metallic fretting around the sliding screws and rods. The average wear mass of the UHMWPE gaskets was 0.002 ± 0.001 g, less than 1.7% of the original mass. In the sliding test, the novel growth guidance system demonstrated the best sliding ability, with an average maximum sliding distance(AMSD) of 35.75 ± 5.73 mm, significantly better than the group of the traditional Shilla technique(AMSD 3.65 ± 0.46 mm, P < 0.0001). CONCLUSION: In conclusion, we modified the Shilla technique and designed a novel growth guidance system by changing the friction interface of sliding screw and rod, which may significantly reduce the metallic debris and promote spine growth. The fatigue test and sliding dislocation test demonstrated the better durability and glidability of the system. An in vivo animal experiment should be performed to further verify the system.


Assuntos
Teste de Materiais , Polietilenos , Escoliose , Humanos , Teste de Materiais/métodos , Fricção , Parafusos Ósseos , Técnicas In Vitro
2.
Clin Orthop Relat Res ; 482(6): 1074-1086, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38427791

RESUMO

BACKGROUND: Peracetic acid and irradiation are common sterilization methods for allograft tendons; however, under some conditions, both methods adversely affect the fiber arrangement and ultimate load of the tendon. An in vitro study showed that low-dose peracetic acid combined with irradiation may be less detrimental to allograft tendon structure and properties, possibly because the breakdown of peracetic acid can lead to an enlargement of the interstitial spaces and an increase in porosity. QUESTIONS/PURPOSES: Using a rabbit Achilles tendon model, we asked: What is the effect of peracetic acid-ethanol combined irradiation on (1) the histopathology and fiber diameter of the allograft tendon, (2) tensile creep and load-to-failure biomechanical properties of allograft tendons, and (3) healing of the treated tendon in vivo compared with fresh-frozen allograft and peracetic acid-ethanol sterilization at 4 and 8 weeks? METHODS: The Achilles tendons used in this study were sourced from euthanized 10-week-old male New Zealand White rabbits previously used for ophthalmic experiments. All allografts were divided into three groups: fresh-frozen group (control group, n = 20), peracetic acid-ethanol sterilization group (n =20), and peracetic acid-ethanol combined irradiation group (n = 20). The sterilization protocols were performed per a predetermined plan. In the peracetic acid-ethanol sterilization group, the tendon tissues were covered with the peracetic acid-ethanol sterilization solution (1% peracetic acid for 30 minutes). In the peracetic acid-ethanol combined irradiation group, the tendon tissues were covered with the peracetic acid-ethanol sterilization solution (0.2% peracetic acid for 30 minutes) and were subjected to 15 kGy gamma irradiation. Thirty 10-week-old male New Zealand White rabbits received bilateral Achilles tendon allografts surgically. Tendon samples from each group were harvested at 4 weeks (n = 30) and 8 weeks (n = 30) postoperatively. For each timepoint, eight tissues were used for histologic staining and electron microscopy, 15 tissues were used for biomechanical testing, and seven tissues were used for hydroxyproline assay and quantitative polymerase chain reaction. Histopathology was determined qualitatively by hematoxylin and eosin and Masson staining, while fiber diameter was measured quantitatively by transmission electron microscopy. Biomechanical properties were measured using cyclic loading tests and load-to-failure tests. The healing outcome was quantitatively judged through healing-related genes and proteins. RESULTS: At 4 weeks and 8 weeks postoperatively, the peracetic acid-ethanol combined irradiation group visually demonstrated the best continuity and minimal peripheral adhesions. Histologic staining showed that tendon fibers in the peracetic acid-ethanol combined irradiation group maintained consistent alignment without notable disruptions or discontinuities, and there was a qualitatively observed increase in the number of infiltrating cells compared with the control group at the 4-week timepoint (444 ± 49 /mm 2 versus 256 ± 43 /mm 2 , mean difference 188 /mm 2 [95% confidence interval 96 to 281]; p < 0.001). At 8 weeks postoperatively, the tendon fiber diameter in the peracetic acid-ethanol combined irradiation groups was similar to that of the control group (0.23 ± 0.04 µm versus 0.21 ± 0.03 µm, mean difference 0.02 µm [95% CI -0.04 to 0.08]; p = 0.56). At 8 weeks postoperatively, the peracetic acid-ethanol combined irradiation group exhibited better properties in terms of both ultimate load (129 ± 15 N versus 89 ± 20 N, mean difference 40 N [95% CI 7 to 73]; p = 0.02) and energy absorption density (17 ± 6 kJ/m 2 versus 8 ± 4 kJ/m 2 , mean difference 8 kJ/m 2 [95% CI 0.7 to 16]; p = 0.004) compared with the control group. Gene expression analysis revealed higher expression levels of COL1A1 (2.1 ± 0.8 versus 1.0 ± 0, mean difference 1.1 [95% CI 0.1 to 2.1]; p = 0.003) and MMP13 (2.0 ± 0.8 versus 1.0 ± 0, mean difference 1.0 [95% CI 0.4 to 1.6]; p = 0.03) in the peracetic acid-ethanol combined irradiation group than in the control group. There was a higher amount of collagen Type I in tendons treated with peracetic acid-ethanol combined irradiation than in the control group (0.36 ± 0.03 versus 0.31 ± 0.04, mean difference 0.05 [95% CI 0.01 to 0.09]; p = 0.02). CONCLUSION: Treatment with peracetic acid-ethanol combined irradiation did not have any discernible adverse effect on the histology, fiber diameter, enzymatic resistance, collagen content, or biomechanical strength of the allograft tendons compared with the control group. Peracetic acid-ethanol combined irradiation treatment had a positive impact on remodeling of the extracellular matrix and realignment of collagen fibers. CLINICAL RELEVANCE: This sterilization method could be helpful to expand the scope and frequency with which allogeneic materials are applied. The long-term healing effect and strength of allograft tendons must be tested before clinical use, and it is necessary to conduct comparative studies on autografts and synthetic materials that are currently widely used clinically.


Assuntos
Tendão do Calcâneo , Aloenxertos , Etanol , Ácido Peracético , Esterilização , Cicatrização , Animais , Coelhos , Masculino , Cicatrização/efeitos da radiação , Cicatrização/efeitos dos fármacos , Ácido Peracético/farmacologia , Etanol/farmacologia , Esterilização/métodos , Tendão do Calcâneo/cirurgia , Tendão do Calcâneo/efeitos da radiação , Tendão do Calcâneo/patologia , Resistência à Tração , Fenômenos Biomecânicos , Fatores de Tempo , Traumatismos dos Tendões/cirurgia
3.
Front Cell Dev Biol ; 11: 1282573, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37965575

RESUMO

Growing rod implantation, a surgery treatment for EOS (early onset scoliosis), may cause a kind of chronic inflammation called metalosis and all other implant-related complications because of the metal debris released by the implants as a result of fraction and corrosion. There is no complete explanation of immunologic mechanisms of metalosis up to now. This review demonstrates the researches on metalosis from the clinical issues down to basic immunologic mechanisms. Adverse reactions of metal implants are mainly the formation of NLRP3 (nod-like receptor protein 3) inflammasome, primed by TLR4 (toll-like receptor protein 4), activated by phagocytosis and often accompanied by type Ⅳ hypersensitive reaction. Recent studies found that TNF-α (tumor necrosis factor α) also participates in priming, and activation of inflammasome requires disturbance of lysosome and release of cathepsin B. Ca-074Me and MCC950 are therapeutic interventions worth exploring in aseptic loosening of orthopedic implants.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...