Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Korean Med Sci ; 38(27): e215, 2023 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-37431543

RESUMO

BACKGROUND: This study investigated whether concomitant facial bone (FB) fractures reduce temporal bone (TB) injuries, such as posttraumatic facial palsy and vertigo, through an impact absorbing effect, so-called "cushion effect," in severe trauma patients. METHODS: A total of 134 patients with a TB fracture were included. They were divided into two groups according to their concomitant facial fractures: group I (no FB fracture) and group II (FB fracture). We compared clinical characteristics, such as brain injury, trauma severity, and complications of TB fracture, between the two groups. RESULTS: In group II, immediate facial palsy was more frequent (11.6% vs. 1.5% in group I), and the Injury Severity Score was higher (19.0 ± 5.9 vs. 16.7 ± 7.3, P = 0.020). Delayed facial palsy (12.3% in group I vs. 4.3% in group II) and posttraumatic vertigo (24.6% vs. 7.2%) occurred more often in group I. FB fractures significantly decreased the incidence of posttraumatic vertigo (odds ratio [OR], 0.276; 95% confidence interval [CI], 0.083-0.914). Intraventricular hemorrhage (OR, 20.958; 95% CI, 2.075-211.677), facial nerve canal injury (OR, 12.229; 95% CI, 2.465-60.670), and FB fractures (OR, 16.420; 95% CI, 1.298-207.738) increased the risk of immediate facial palsy. CONCLUSION: Concomitant FB fractures reduced the risk of the occurrence of delayed facial palsy and posttraumatic vertigo in injured patients with TB fracture. Particularly, an anterior force may be reduced by the cushion effect of the bony fracture.


Assuntos
Lesões Encefálicas , Paralisia Facial , Fraturas Ósseas , Humanos , Paralisia Facial/etiologia , Face , Fraturas Ósseas/complicações , Hemorragia Cerebral
2.
Laryngoscope Investig Otolaryngol ; 7(3): 662-670, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35734052

RESUMO

Objective: Cone-beam computed tomography (CBCT) is a promising imaging modality for sinonasal evaluation, with advantages of relatively low radiation dose, low cost, and quick outpatient imaging. Our study aimed to compare the diagnostic performance and image quality of CBCT with those of multi-detector computed tomography (MDCT) with different slice thickness. Methods: We retrospectively reviewed 60 consecutive patients who had undergone both CBCT and MDCT. MDCT images was reconstructed with 1 and 3 mm slice thickness. The quantitative image quality parameters (image noise, signal-to-noise ratio [SNR], and contrast-to noise ratio [CNR] were calculated and compared between the two imaging modalities. Two observers (ENT surgeon and neuroradiologist) evaluated the presence of seven sinonasal anatomic variations in each patient and interobserver agreements were analyzed. The diagnostic performance of CBCT (0.3 mm) and MDCT (3 mm) was assessed and compared with that of high resolution MDCT (1 mm), which is considered as the gold standard. Results: The image noise was significantly higher and SNR and CNR values were lower in the CBCT (0.3 mm) group than in the MDCT groups (1 and 3 mm). The diagnostic performance of CBCT (0.3 mm) was similar to that of MDCT (1 mm) and superior to that of MDCT (3 mm). The highest interobserver agreement was for high resolution MDCT (1 mm), followed by CBCT (0.3 mm), and MDCT (3 mm). Conclusion: Considering its low radiation dose, low cost, and ease of clinical access, CBCT may be a useful imaging modality for as first line sinonasal evaluation and repeated follow up.Study design: Retrospective study in a tertiary referral university center.Level of evidence: NA.

3.
Sleep Breath ; 25(3): 1477-1485, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33398794

RESUMO

PURPOSE: Positive airway pressure (PAP) devices have been widely used as the first line of treatment in obstructive sleep apnea (OSA). Most advanced PAP devices support the estimation of respiratory index (RI) using the patient's mask airflow. In addition to the compliance factor for PAP device use, which is important for monitoring patient sleep health, RI is also becoming important for monitoring. However, there are few reports that validate RI of a PAP device with polysomnography. METHODS: Between January 2015 and December 2017, 50 participants were enrolled who were diagnosed with OSA and prescribed auto-titration PAP (APAP) devices. The RIs of participants were measured at night using APAP devices, concurrently with electroencephalography, respiratory inductance plethysmography sensors, and other polysomnographic sensors in a sleep laboratory. The respiratory-related data of APAP were prospectively analyzed with the manually scored polysomnographic data. RESULTS: The apnea-hypopnea index and apnea index showed a statistically close relationship between the auto-scored respiratory data from the APAP device and the manually scored respiratory data from polysomnographic sensors. Obstructive apnea and central apnea indices showed relatively low correlations. The differences between the auto-scored RI and manually scored RI were influenced by BMI, waist circumference, weight, oxygen saturation, and respiratory distress indices of diagnostic polysomnographic factors. CONCLUSIONS: The RIs of APAP devices have a tendency to be underestimated or mismatched when compared with polysomnography. Sleep specialists are advised to consider additional anthropometric and diagnostic factors to account for these differences during PAP treatment.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Respiração , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...