Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 12(5)2019 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-30862082

RESUMO

In this paper, the densification mechanism of ultrasonic compaction was analyzed using a force balance model. Ultrasonic compaction is quite a promising way to solve the lower mechanical property problem of green compact in the compaction process, although it has some obstacles to overcome for its various applications. Our model proposes that the resultant density is achieved as the applied and resistance forces reach the equilibrium state. Based on the proposed model, the ultrasonic compaction increases the density of green compact by reducing the internal friction between the powder and compaction die, as well as the internal friction among particles themselves. It was also found that during the powder compaction, the ultrasonic vibration mostly contributes to slipping and the rearrangement of the particles.

2.
Langmuir ; 24(15): 8127-33, 2008 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-18605744

RESUMO

Supported bilayer membranes (SBMs) formed on solid substrates, in particular glass, provide an ideal cell mimicking model system that has been found to be highly useful for biosensing applications. Although the stability of the membrane structures is known to determine the applicability, the subject has not been extensively investigated, largely because of the lack of convenient methods to monitor changes of membrane properties on glass in real time. This work reports the evaluation of the stability properties of a series of SBMs against chemical and air damage by use of surface plasmon resonance spectroscopy and nanoglassified gold substrates. Seven SBMs composed of phosphatidylcholine and DOPC+, including single-component, mixed, protein-reinforced SBMs (rSBMs) and protein-tethered bilayer membranes (ptBLMs), are studied. The stability properties under various conditions, especially the effects of surfactants, organic solvents, and dehydration damage on the bilayers, are compared. PC membranes are found to be easily removed from the glassy surfaces using relatively low concentrations of the surfactants, while DOPC+ is markedly more stable toward nonionic surfactant. DOPC+ membranes also demonstrated remarkable air stability while PC films exhibited considerable damage from dehydration. Doping of cholesterol does not improve PC's stability against SDS and Triton but changes the lipid membrane packing enough to protect against dehydration damage. Although rSBMs and ptBLMs improve air stability to a certain degree, they are still quite susceptible to significant damage/removal from ionic and nonionic surfactants at lower concentrations. Overall, DOPC+ has noted higher stability on glass, likely due to the favorable electrostatic interaction between the silicate surface and the lipid headgroup, making it a good candidate for application. Nanoglassy SPR proves to be an attractive platform capable of rapidly screening film stability in real-time, providing critical information for future work using supported membranes for sensing applications.


Assuntos
Vidro , Bicamadas Lipídicas/química , Nanoestruturas/química , Colesterol/química , Ouro/química , Ressonância de Plasmônio de Superfície , Fatores de Tempo
3.
Anal Chem ; 80(16): 6397-404, 2008 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-18620431

RESUMO

We report the development of an air-stable, supported membrane array by use of photolithography for label-free detection of lipid-protein interactions. Phosphoinositides and their phosphorylated derivatives (PIPs) were studied for their binding properties to proteins with lipid microarray in combination with surface plasmon resonance imaging (SPRi). We have demonstrated a simple method to fabricate lipid arrays using photoresist and carried out a series of surface characterizations with SPRi, ac impedance, cyclic voltammetry, and fluorescence microscopy to validate the array quality and lipid bilayer formation. A number of lipid compositions have been tested for the robustness of resulting membranes when undergoing dehydration and rehydration procedures, and the 1,2-dioleoyl-sn-glycero-3-ethylphosphocholine/poly(ethylene glycol)-phosphatidylethanolamine (DOPC+/PEG-PE) system stands out as the best performer that yields the recovery to within 2% of the original state according to SPR sensorgrams. Limits of detection on the dehydrated/rehydrated DOPC+/PEG-PE membranes were determined to be 33 nM for avidin binding to biotinylated lipids, 73.5 nM for cholera toxin to GM1, and 25 nM for PtdIns(4,5)P2-binding protein (P(4,5)BP) to PtdIns(4,5)P2 lipid, respectively. These results demonstrate the suitability and sensitivity of this membrane for constructing membrane arrays for SPRi analysis under ambient conditions. With the use of this addressable and functional lipid membrane array, the screening of specific lipid-protein interactions has been conducted. Strong and specific interactions between P(4,5)BP and PtdIns(4,5)P2/DOPC+/PEG-PE membrane were observed as expected, while cross reactions were spotted for P(4,5)BP/PtdIns(4)P and avidin/GM1 at varied degrees. The air-stable membrane array demonstrated here presents a simple, effective approach for constructing functional membrane surfaces for screening applications, which opens a new avenue for the label-free study of membrane proteins and other forms of lipid-membrane interactions.


Assuntos
Bicamadas Lipídicas/química , Proteínas de Membrana/química , Nanoestruturas/química , Fosfatidilinositóis/metabolismo , Fotoquímica/métodos , Ressonância de Plasmônio de Superfície , Técnicas Biossensoriais , Impedância Elétrica , Bicamadas Lipídicas/metabolismo , Proteínas de Membrana/metabolismo , Ligação Proteica
4.
Anal Chem ; 79(3): 899-907, 2007 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-17263314

RESUMO

Detection of trace amounts of target proteins in the presence of high concentrations of matrix proteins (e.g., serum samples) without separation steps is of great significance to biomedical research but remains technically challenging. Here we report a "membrane cloaking" method to overcome nonspecific protein adsorption and fouling problems for label-free surface plasmon resonance detection and heterogeneous immunosensing. A thin, hybrid, self-assembled monolayer on gold was formed with 70 mol % mercaptopropanol and 30 mol % cysteamine/propanedithiol to facilitate membrane fusion and covalent attachment of antibodies. After antibody immobilization, the surface was incubated with lipid vesicles, which fused to form a supported membrane. The analyte spiked in serum was introduced for binding, and the membrane and nonspecifically adsorbed proteins on the membrane were subsequently removed using a nonionic surfactant before the final measurement was carried out. Selection of a suitable surfactant can preserve antibody/antigen binding and selectively remove the membrane, allowing accurate measurement of the captured proteins without interference from nonspecifically adsorbed species. Surface plasmon resonance (SPR) quantification of IgG spiked in undiluted serum ( approximately 75 mg/mL protein) was achieved with the membrane cloaking method, whereas direct measurement without membrane removal resulted in a significantly large error. The cloaking method was also used to develop an enzyme amplified amperometric assay using HRP-conjugated IgG. Detection of concentrations as low as 5 fM proteins was obtained. Finally, a membrane cloaking assay combining SPR and in situ electrochemical measurement was demonstrated on a gold substrate. Similar sensitivity was observed using a continuous flow injection measurement. The method opens new avenues to develop direct assay methods with ultrahigh sensitivity for protein samples using SPR and enzyme-linked amplification mechanisms.


Assuntos
Proteínas Sanguíneas/isolamento & purificação , Técnicas Imunoenzimáticas/métodos , Técnicas Imunoenzimáticas/normas , Ressonância de Plasmônio de Superfície/métodos , Adsorção , Proteínas Sanguíneas/análise , Eletroquímica , Enzimas Imobilizadas , Ouro , Humanos , Técnicas Imunoenzimáticas/instrumentação , Imunoglobulina G/sangue , Lipídeos , Métodos , Ligação Proteica , Ressonância de Plasmônio de Superfície/normas , Tensoativos
5.
Anal Chem ; 78(2): 596-603, 2006 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-16408945

RESUMO

Surface plasmon resonance (SPR) spectroscopy, a powerful tool for biosensing and protein interaction analysis, is currently confined to gold substrates and the relevant surface chemistries involving dextran and functional thiols. Drawbacks of using self-assembled monolayers (SAMs) for SPR-related surface modification include limited stability, pinhole defects, bioincompatibility, and nonspecific protein adsorption. Here we report the development of stable nanometer-scale glass (silicate) layers on gold substrates for SPR analysis of protein toxins. The nanoscale silicate layers were built up with layer-by-layer deposition of poly(allylamine hydrochloride) and sodium silicate, followed by calcination at high temperature. The resulting silicate films have a thickness ranging from 2 to 15 nm and demonstrate outstanding stability in flow cell conditions. The use of these surfaces as a platform to construct supported bilayer membranes (SBMs) is demonstrated, and improved performance against protein adsorption on SBM-coated surfaces is quantified by SPR measurements. SBMs can be formed reproducibly on the silicate surface via vesicle fusion and quantitatively removed using injection of 5% Triton X-100 solution, generating a fresh surface for each test. Membrane properties such as lateral diffusion of the SBMs on the silicate films are characterized with photobleaching methods. Studies of protein binding with biotin/avidin and ganglioside/cholera toxin systems show detection limits lower than 1 microg/mL (i.e., nanomolar range), and the response reproducibility is better than 7% RSD. The method reported here allows many assay techniques developed for glass surfaces to be transferred to label-free SPR analysis without the need for adaptation of protocols and time-consuming synthetic development of thiol-based materials and opens new avenues for developing novel bioanalytical technologies for protein analysis.


Assuntos
Ouro/química , Nanoestruturas/química , Silicatos/química , Ressonância de Plasmônio de Superfície/métodos , Avidina/química , Biotina/química , Toxina da Cólera/fisiologia , Gangliosídeos/fisiologia , Poliaminas/química , Ligação Proteica/fisiologia
6.
Am J Clin Pathol ; 119(3): 356-60, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12645336

RESUMO

We randomly selected 50 cervical smears (benign, 14; atypical squamous cells of undetermined significance [ASCUS], 5; low-grade squamous intraepithelial lesion [LSIL], 10; high-grade squamous intraepithelial lesion (HSIL), 12; squamous cell carcinoma, 6; adenocarcinoma, 3) and captured 1,181 digital images (518 MB) at a maximum resolution of 1,600 x 1,200 pixels and transmitted them by e-mail. Diagnosis of glass slides and digital images was done independently in a double-blind manner by 3 pathologists and 3 cytotechnologists, commencing with the diagnosis of digital images followed by diagnosis of glass slides 3 months later. The procedure was repeated after 3 months. Diagnoses were recorded as benign, ASCUS or atypical glandular cells of undetermined significance, LSIL, HSIL, squamous cell carcinoma or adenocarcinoma, and "inadequate for diagnosis." Diagnostic accuracy and interobserver reproducibility were analyzed using an intraclass correlation coefficient (ICC), which revealed good interobserver agreement for the first (0.72) and second (0.64) glass slide diagnoses and the first (0.72) and second (0.60) digital image diagnoses. The kappa values for intraobserver variation between first and second glass slide diagnoses and first and second digital image diagnoses showed moderate to excellent agreement. Digital images are suitable substitutes for glass slides; telecytology can be used as an alternative method for the cytologic diagnosis of cervical smears, particularly in quality assurance programs.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde , Telepatologia/métodos , Esfregaço Vaginal/métodos , Adenocarcinoma/diagnóstico , Carcinoma de Células Escamosas/diagnóstico , Consenso , Método Duplo-Cego , Feminino , Humanos , Variações Dependentes do Observador , Distribuição Aleatória , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Displasia do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...