Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Antimicrob Chemother ; 74(8): 2255-2260, 2019 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-31038158

RESUMO

OBJECTIVES: MALDI-TOF MS has been successfully used for empirical antibiotic selection. However, limited data are available regarding the usefulness of MALDI-TOF MS in common resistant organisms compared with rapid antimicrobial susceptibility testing (AST). We prospectively evaluated the usefulness of rapid AST, compared with MALDI-TOF MS, for optimal antibiotic selection by infectious disease (ID) physicians in patients with bacteraemia including polymicrobial infection. METHODS: Three hundred and fifty-nine patients with positive blood culture were included for analysis. ID physicians prospectively decided on antibiotic regimens with consensus at each timepoint of receiving results of Gram stain, MALDI-TOF MS and rapid AST, the last of which was performed using QMAC-dRAST. RESULTS: ID physicians with MALDI-TOF MS results chose optimal targeted antibiotics in 255 (71.0%) cases, with appropriate antibiotic selection in 303 (84.4%) cases. The proportion of optimal targeted antibiotic selection and appropriate antibiotic selection was significantly lower for resistant strains than for susceptible strains [62.5% versus 79.2% (P < 0.001) and 68.2% versus 100% (P < 0.001), respectively]. QMAC-dRAST results led to optimal antibiotic treatment in 95 (91.3%) of the 104 cases receiving non-optimal targeted antibiotics. Optimal targeted treatments based on QMAC-dRAST results were possible in 322 (98.2%) of the 328 cases with monobacterial infection and in 345 (96.1%) of the 359 cases with monobacterial and polymicrobial infection. CONCLUSIONS: MALDI-TOF MS has a high chance of failure in guiding ID physicians to optimal antibiotics, especially against resistant organisms. With increasingly common resistant organisms, rapid AST is needed to identify optimal targeted antibiotics early in bacteraemia.


Assuntos
Antibacterianos/farmacologia , Bacteriemia/tratamento farmacológico , Bactérias/efeitos dos fármacos , Testes de Sensibilidade Microbiana/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bacteriemia/diagnóstico , Bactérias/isolamento & purificação , Hemocultura , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Fatores de Tempo , Adulto Jovem
2.
Biomicrofluidics ; 12(3): 031102, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29774082

RESUMO

Understanding tissue engineering using a bottom-up approach has been hindered by technical limitations because no platform can demonstrate the controlled formation of a heterogeneous population of cells in microscale. Here, we demonstrate hierarchical shape-by-shape assembly of virus-laden particles into larger ones to transfect two different genes on the seeded cells. We show that smaller daughter particles with different sizes and shapes can be assembled into the matching indentations of larger parent particles with different sizes and shapes. Then, we transfected a population of cells with two different gene-transfecting viruses, each of which was laden on the parent or daughter particles.

3.
J Med Microbiol ; 67(3): 325-331, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29458541

RESUMO

PURPOSE: The direct rapid antibiotic susceptibility test (dRAST), based on analysing changes in bacterial micro-colonies under antibiotic conditions, detects antibiotic resistance within 6 h of direct smear examination results. This study aimed to assess the accuracy of dRAST and evaluate its potential usefulness for improving selection of appropriate antibiotic in real clinical practice settings. METHODOLOGY: We evaluated the accuracy of dRAST by comparing the antibiotic treatments that should have been administered based on dRAST results and the broth microdilution (BMD) test and its potential usefulness via simulation. RESULT: For 49/52 (94.2 %) patients with Gram-positive bacteraemia and 66/67 (98.5 %) patients with Gram-negative bacteraemia, antibiotics indicated by dRAST results were the same as those indicated by the BMD test. Among 34 patients with ineffective and suboptimal treatment, 19 (55.9 %) of patients could have received optimal treatment 1 to 2 days earlier with dRAST results. Among 33 patients given unnecessary broad-spectrum antibiotics, 1 to 2 days earlier de-escalation could have been possible for 27 (81.8 %) patients based on dRAST results. CONCLUSION: The introduction of dRAST could increase the use of optimal antibiotics and reduce unnecessary broad-spectrum antibiotic use in the early period of bacteraemia.


Assuntos
Antibacterianos/farmacologia , Hemocultura , Bactérias Gram-Negativas/efeitos dos fármacos , Bactérias Gram-Positivas/efeitos dos fármacos , Testes de Sensibilidade Microbiana/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bacteriemia/tratamento farmacológico , Bacteriemia/microbiologia , Confiabilidade dos Dados , Feminino , Bactérias Gram-Negativas/isolamento & purificação , Bactérias Gram-Positivas/isolamento & purificação , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
4.
Lab Chip ; 17(14): 2435-2442, 2017 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-28555213

RESUMO

The increasing number of potential drug targets and compounds has led to the development of high-throughput cell-based assays. Simultaneous processing of multiple targets in the same experiment based on localized target gene expression is a very efficient strategy for this purpose. To address this need, we present an adenoviral vector-immobilized microparticle with two-dimensional (2D) shape-encoding properties that allows localized patch-like gene delivery to monolayer-cultured cells. This format conveniently achieves multiplexed gene delivery compatible with both high-throughput cellular assays and fluorescence high-content imaging instruments. A multiplex G protein-coupled receptor (GPCR) internalization assay was developed to demonstrate the compatibility of this system with high-throughput image-based cellular assays.


Assuntos
Adenoviridae/genética , Técnicas Citológicas/instrumentação , Técnicas de Transferência de Genes , Microtecnologia/instrumentação , Linhagem Celular Tumoral , Técnicas Citológicas/métodos , Desenho de Equipamento , Corantes Fluorescentes/análise , Corantes Fluorescentes/química , Humanos , Microtecnologia/métodos
5.
Sci Rep ; 7(1): 1148, 2017 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-28442767

RESUMO

For the timely treatment of patients with infections in bloodstream and cerebrospinal fluid, a rapid antimicrobial susceptibility test (AST) is urgently needed. Here, we describe a direct and rapid antimicrobial susceptibility testing (dRAST) system, which can determine the antimicrobial susceptibility of bacteria from a positive blood culture bottle (PBCB) in six hours. The positive blood culture sample is directly mixed with agarose and inoculated into a micropatterned plastic microchip with lyophilized antibiotic agents. Using microscopic detection of bacterial colony formation in agarose, the total time to result from a PBCB for dRAST was only six hours for a wide range of bacterial concentrations in PBCBs. The results from the dRAST system were consistent with the results from a standard AST, broth microdilution test. In tests of clinical isolates (n = 206) composed of 16 Gram-negative species and seven Gram-positive species, the dRAST system was accurate compared to the standard broth microdilution test, with rates of 91.11% (2613/2868) categorical agreement, 6.69% (192/2868) minor error, 2.72% (50/1837) major error and 1.45% (13/896) very major error. Thus, the dRAST system can be used to rapidly identify appropriate antimicrobial agents for the treatment of blood stream infection (BSI) and antibiotic-resistant strain infections.


Assuntos
Hemocultura , Testes de Sensibilidade Microbiana/métodos , Microscopia/métodos , Imagem Óptica/métodos , Antibacterianos/farmacologia , Bacteriemia/microbiologia , Humanos , Meningites Bacterianas/microbiologia , Fatores de Tempo
6.
Adv Mater ; 27(12): 2083-9, 2015 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-25656227

RESUMO

An unclonable, fingerprint-mimicking anti-counterfeiting strategy is presented that encrypts polymeric particles with randomly generated silica film wrinkles. The generated wrinkle codes are as highly unique as human fingerprints and are technically irreproducible. Superior to previous physical unclonable functions, codes are tunable on demand and generable on various geometries. Reliable authentication of real-world products that have these microfingerprints is demonstrated using optical decoding methods.


Assuntos
Biomimética/métodos , Dermatoglifia , Fraude/prevenção & controle , Humanos , Fenômenos Mecânicos , Microesferas , Dióxido de Silício
7.
Opt Lett ; 39(17): 5162-5, 2014 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-25166099

RESUMO

This article presents free-floating three-dimensional (3D) microstructure fabrication in a microfluidic channel using direct fine-tuned grayscale image lithography. The image is designed as a freeform shape and is composed of gray shades as light-absorbing features. Gray shade levels are modulated through multiple reflections of light in a digital micromirror device (DMD) to produce different height formations. Whereas conventional photolithography has several limitations in producing grayscale colors on photomask features, our method focuses on a maskless, single-shot process for fabrication of freeform 3D micro-scale shapes. The fine-tuned gray image is designed using an 8-bit grayscale color; thus, each pixel is capable of displaying 256 gray shades. The pattern of the UV light reflecting on the DMD is transferred to a photocurable resin flowing through a microfluidic channel. Here, we demonstrate diverse free-floating 3D microstructure fabrication using fine-tuned grayscale image lithography. Additionally, we produce polymeric microstructures with locally embedded gray encoding patterns, such as grayscale-encoded microtags. This functional microstructure can be applied to a biophysical detection system combined with 3D microstructures. This method would be suitable for fabricating 3D microstructures that have a specific morphology to be used for particular biological or medical applications.

8.
Adv Mater ; 24(44): 5924-9, 2012 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-22930454

RESUMO

A QR-coded microtaggant for the anti-counterfeiting of drugs is proposed that can provide high capacity and error-correction capability. It is fabricated lithographically in a microfluidic channel with special consideration of the island patterns in the QR Code. The microtaggant is incorporated in the drug capsule ("on-dose authentication") and can be read by a simple smartphone QR Code reader application when removed from the capsule and washed free of drug.


Assuntos
Medicamentos Falsificados/análise , Rotulagem de Medicamentos/métodos , Polímeros/química , Dispositivo de Identificação por Radiofrequência/métodos , Fotografação/métodos , Polímeros/efeitos da radiação
10.
Lab Chip ; 10(20): 2814-7, 2010 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-20721367

RESUMO

Rectangular fluidic channels have rarely been used in microfluidic devices which use PDMS membrane-type microvalves, since the rectangular channel shape does not perfectly match the round shape of the membrane deformation. We present a polymer sealing method to fabricate PDMS membrane-type microvalves for rectangular microchannels. After fabricating the microfluidic device, photocurable oligomer is introduced into the fluidic channel and gas pressure is applied to the pneumatic channel to deform the membrane. The polymer seal is then locally polymerized by photolithography producing a structure matching the shape of the deformed membrane curvature. We compare the flow leakage between the membrane-type microvalve with and without a polymer seal. We also demonstrate a micropump and droplet generator using this embedded polymer membrane-type microvalve in a rectangular microfluidic channel. This polymeric seal technique enables the use of easily fabricated rectangular channel membrane microvalves with all the functionality of their curved channel counterparts with negligible flow leakage.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...