Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Hazard Mater ; 472: 134508, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38754234

RESUMO

As one of main high-energy fuels for rocket launching, unsymmetrical dimethylhydrazine (UDMH) and its decomposition products do harm to environment and human health. It is significant to develop a device to monitor its leakage. In this work, a UDMH gas sensor based on In2O3 hollow microspheres with Nd dopant was fabricated. The pure, 1.0 mol%, 3.0 mol% and 5.0 mol% Nd doped In2O3 were synthesized via one-step solvothermal method. Among them, 3.0% Nd-In2O3 based sensor exhibits the highest response toward UDMH vapor. Its response value to 100 ppm UDMH is 183.3 at optimal working temperature of 250 °C, 6.8 times higher than that of pure In2O3 (26.8). Besides high response to UDMH, the 3% Nd-In2O3 based sensor represents excellent selectivity, rapid response speed (2 s) and ultra-low theoretical LOD to UDMH (0.28 ppb). The improved gas sensing performance via Nd doping could be attributed to the enhanced specific surface area, increased concentration of adsorbed oxygen and improved adsorption capacity for UDMH molecular on the surface. The excellent sensing performance of Nd doped In2O3 hollow microspheres makes it a promising candidate for real-time UDMH detection.

2.
Nanomaterials (Basel) ; 12(19)2022 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-36234395

RESUMO

Carbon monoxide (CO) is one of the most toxic gases to human life. Therefore, the effective monitoring of it down to ppb level is of great significance. Herein, a series of In2O3 nanofibers modified with Au or Pd species or simultaneous Au and Pd species have been prepared by electrospinning combined with a calcination process. The as-obtained samples are applied for the detection of CO. Gas-sensing investigations indicate that 2 at% Au and 2 at% Pd-co-modified In2O3 nanofibers exhibit the highest response (21.7) to 100 ppm CO at 180 °C, and the response value is ~8.5 times higher than that of pure In2O3 nanofibers. More importantly, the detection limit to CO is about 200 ppb with a response value of 1.23, and is obviously lower than that (6 ppm) of pure In2O3 nanofibers. In addition, the sensor also shows good stability within 19 days. These demonstrate that co-modifying In2O3 nanofibers with suitable amounts of Pd and Au species might be a meaningful strategy for the development of high-performance carbon monoxide gas sensors.

3.
ACS Sens ; 7(4): 995-1007, 2022 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-35377609

RESUMO

Designing high-performance triethylamine gas sensors with the stable gas response and low resistance variation in air under a wide relative humidity range is expected for human health and environmental surveillance. Here, a novel porous NiO/NiFe2O4 fiber-in-tube nanostructure is prepared by the electrospinning process. The characterizations related to microstructure and surface morphology are carried out. Meanwhile, the gas sensing performance of the porous fiber-in-tube NiO/NiFe2O4 materials is evaluated and compared systematically. The results indicate that the introduction of NiO as the second component can not only reduce the baseline resistance of NiFe2O4 gas sensors dramatically but also optimize the gas sensing performance to a significant extent. Especially, the fabricated sensor based on the NiO/NiFe2O4 fiber-in-tube with a Ni/Fe molar ratio of 1.5 exhibits the best performance. The gas response while detecting 50 ppm triethylamine at 300 °C is about 3.6 times higher than that with Ni/Fe molar ratio of 0.5. Moreover, the response values become more stable, and the baseline resistance has a lower variation under a wide relative humidity range, demonstrating the excellent humidity resistance. These phenomena might be ascribed to the distinctive fiber-in-tube nanostructure as well as the heterojunction between NiFe2O4 and NiO.


Assuntos
Etilaminas , Nanoestruturas , Humanos , Umidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...