1.
Int J Artif Organs ; 47(3): 198-204, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38326931

RESUMO

INTRODUCTION: To understand the behavior of platelet volume indices and the von Willebrand factor (VWF), in vitro experiments using whole human blood were performed with extracorporeal circulation (ECC) circuits, including membrane oxygenators coated with acrylate copolymer (ACP) or immobilized heparin (IHP). METHODS: Heparinized blood was circulated through two distinct experimental circuits: an ACP-coated reservoir and tubes, as well as membranes coated with either ACP or IHP (comprising five pieces of each type). The platelet distribution width, mean platelet volume (MPV), platelet large cell ratio (P-LCR), VWF quantity (VWFQ), and VWF activity (VWFA) were measured at 0, 8, 16, 24, and 32 h in each experiment. A two-way analysis of variance (ANOVA) was performed to determine whether the coating type or circulation duration affected the transition of each measurement. RESULTS: Two-way ANOVA indicated that the transitions of MPV, P-LCR, and VWFA were significantly affected by the circulation duration (p = 0.030, 0.001, and <0.001, respectively) and that the transitions of VWFQ and VWFA were significantly affected by the coating type (p = 0.022 and 0.006, respectively). Factor interactions between the coating type and circulation duration were not observed for each transition (p > 0.05). CONCLUSIONS: Our findings suggest that P-LCR is a good index for platelet activation in blood-circulating ECC and that VWFA and VWFQ are significantly attenuated in blood-circulating ECC with ACP-coated membranes, indicating the advantage of IHP coating regarding platelet activation.


Assuntos
Heparina , Oxigenadores de Membrana , Humanos , Fator de von Willebrand/metabolismo , Polímeros , Plaquetas/fisiologia
2.
Perfusion ; : 2676591231177912, 2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37216953

RESUMO

INTRODUCTION: The membrane oxygenator in extracorporeal circulation circuits is coated with acrylate-copolymer (ACP) or immobilized heparin (IHP) to enhance hemocompatibility. To evaluate the relative features of both coatings, we compared blood components circulated in the circuits with ACP-and IHP-coated membranes in vitro using whole human blood. METHODS: Whole human blood was heparinized and circulated in two experimental circuits with an ACP-coated reservoir, tubes, and an ACP- or IHP-coated membrane. Platelet (PLT) counts and the amount of total protein (TP), complement component 3 (C3), and complement component 4 (C4) were measured at 0, 8, 16, 24, and 32 h in each experiment (n = 5). RESULTS: The PLT count at 0-h circulation was lower in the IHP-coated than in the ACP-coated circuits (p = 0.034); however, no significant difference was observed at other time points. Reduction in TP at 8-h and 16-h circulation and in C3 at 32-h circulation was lesser in the ACP-coated than in the IHP-coated circuits (p = 0.004, 0.034, and 0.027, respectively); reduction in TP and C3 at other time points and C4 at each time point was not significantly different. There were significant interactions between coating type and circulation duration in the PLT, TP, and C3 transitions (p = 0.008, 0.020, and 0.043, respectively). CONCLUSIONS: Our findings suggest that ACP-coated membranes can prevent the initial drop in PLT count and C3 consumption over 32 h, whereas IHP-coated membranes could not prevent this drop in extracorporeal circulation. Therefore, ACP-coated membranes are suitable for short- and long-term extracorporeal life support.

3.
Perfusion ; 38(3): 600-608, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35098806

RESUMO

INTRODUCTION: We performed in vitro experiments using whole human blood without anticoagulants to clarify the activity of anticoagulant proteins on membranes coated with acrylate-copolymer (ACP) with a hydrophilic blood-contacting layer compared to those coated by immobilizing heparin (IHP) in extracorporeal circulation. METHODS: Whole human blood from healthy volunteers was recirculated in two types of experimental circuits with an ACP-coated reservoir and tubes and an ACP-coated or IHP-coated membrane. To compare the fluctuation of anticoagulant proteins, the circuit pressure at the inlet and outlet of the membrane was measured every 5 min; antithrombin antigen (ATQ), antithrombin activity, protein-C quantitation (PCQ), protein-C activity, protein-S free antigen (PSQ), and protein-S activity were measured at 0, 30, 60, 120, and 180 min in each experiment (n = 5). RESULTS: The time taken to achieve high circuit pressure (> 300 mmHg) at the inlet of the membrane was significantly shorter in the ACP-coated membrane circuit (28 ± 2.7 min) than in the IHP-coated membrane circuit (54 ± 24 min); however, the ATQ, PCQ, and PSQ at 180 min of recirculation were significantly higher in the former than in the latter (all p < .05). CONCLUSIONS: ACP-coated membranes can prevent the consumption of anticoagulant proteins but cannot delay circuit thrombogenicity compared to IHP-coated membranes. Considering patient care during the post-extracorporeal circulation period, the use of ACP coating, which can preserve anticoagulant protein, is better in extracorporeal circulation circuits.


Assuntos
Anticoagulantes , Heparina , Humanos , Anticoagulantes/farmacologia , Heparina/farmacologia , Polímeros/farmacologia , Circulação Extracorpórea , Antitrombinas
4.
Int J Artif Organs ; 44(6): 385-392, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33222595

RESUMO

INTRODUCTION: A hemodialysis room has pipes connecting the console and central fluid equipment. While these pipes require disinfection, reports detailing disinfection strategies are unavailable. Therefore, we aimed to compare two easy disinfection strategies differing in sanitization frequency and sanitizer concentration. METHODS: Reverse osmosis water (ROW) purifying equipment and six dialysis consoles were connected by 20 m of pipes. Only ROW flowed through these pipes, because the dialysate solution was constituted at each console. The pipes were sanitized by two strategies: (1) strong and monthly (hypochlorite concentration: 100 ppm) or (2) weak and weekly (5 ppm). Both strategies were easy because the sodium hypochlorite was simply added to the ROW tank. To estimate sanitization efficacy, endotoxin counts at the ROW tank outlet, the end of the pipe, and the pipe after the endotoxin-cutting filter in each console were measured monthly for six continuous months. These counts were compared between the two sanitization strategies. RESULTS: The endotoxin counts at the ROW tank outlet and the end of the pipe were 0.004-0.017 and 0.012-0.081 EU/mL, respectively, in the strong and monthly strategy, and 0.001-0.003 and 0.001-0.005 EU/mL, respectively, in the weak and weekly strategy. The endotoxin counts at the pipe after the endotoxin-cutting filter were less than 0.001 EU/mL during the study period in both strategies. CONCLUSION: A weekly disinfection strategy was more effective than a monthly one, despite the lower hypochlorite concentration. The present study suggests that frequency is the most important factor in the disinfection of pipes in a dialysis room.


Assuntos
Desinfecção , Diálise Renal , Soluções para Diálise , Endotoxinas , Contaminação de Equipamentos/prevenção & controle , Filtração
5.
Int J Artif Organs ; 43(6): 405-410, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31875413

RESUMO

OBJECTIVE: Currently, the foreign surfaces of extracorporeal circulation devices are coated with an acrylate-based copolymer that creates a hydrophilic blood-contacting layer to enhance biocompatibility. Several reports of acrylate-based copolymer with respect to biocompatibility have been published; however, the adsorption of peptide compounds on acrylate-based copolymer-coated membranes still requires clarity. In this study, we aimed to understand the adsorption of several peptide compounds of various molecular weights, including albumin, lysozyme, and vancomycin, on acrylate-based copolymer-coated membranes using in vitro studies. METHODS: Six experimental circuits consisting of acrylate-based copolymer-coated tubes and membranes, and six comprising acrylate-based copolymer-coated tubes and non-coated membranes were prepared for comparison. An experimental solution, composed of albumin, lysozyme, vancomycin, and saline, was continuously stirred in a reservoir, recirculated in each experimental circuit, and then filtered. Concentrations of albumin, lysozyme, and vancomycin were measured after 0, 15, 30, 45, 60, 90, and 120 min of recirculation. Similar experiments were performed in all the prepared circuits. RESULTS: The ratio of measured values at each time point to those at 0 min was not significantly different between acrylate-based copolymer-coated and non-coated membranes for albumin and lysozyme, but differed significantly for vancomycin; the ratios were higher in acrylate-based copolymer-coated than in non-coated membranes. CONCLUSION: This study suggests that albumin is not adsorbed on either acrylate-based copolymer-coated or non-coated membranes, that lysozyme is not adsorbed on either membrane or is adsorbed at a similar rate on both membranes, and that vancomycin is less adsorbed on acrylate-based copolymer-coated membranes. Thus, acrylate-based copolymer coating could inhibit the adsorption of various peptide compounds.


Assuntos
Circulação Extracorpórea/métodos , Polímeros/química , Adsorção , Humanos , Interações Hidrofóbicas e Hidrofílicas , Teste de Materiais , Propriedades de Superfície
6.
Int J Mol Sci ; 20(14)2019 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-31319489

RESUMO

Elevated plasma homocysteine levels are considered as a risk factor for cardiovascular diseases as well as preeclampsia-a pregnancy disorder characterized by hypertension and proteinuria. We previously generated mice lacking cystathionine γ-lyase (Cth) as cystathioninuria models and found them to be with cystathioninemia/homocysteinemia. We investigated whether Cth-deficient (Cth-/-) pregnant mice display any features of preeclampsia. Cth-/- females developed normally but showed mild hypertension (~10 mmHg systolic blood pressure elevation) in late pregnancy and mild proteinuria throughout development/pregnancy. Cth-/- dams had normal numbers of pups and exhibited normal maternal behavior except slightly lower breastfeeding activity. However, half of them could not raise their pups owing to defective lactation; they could produce/store the first milk in their mammary glands but not often provide milk to their pups after the first ejection. The serum oxytocin levels and oxytocin receptor expression in the mammary glands were comparable between wild-type and Cth-/- dams, but the contraction responses of mammary gland myoepithelial cells to oxytocin were significantly lower in Cth-/- dams. The contraction responses to oxytocin were lower in uteruses isolated from Cth-/- mice. Our results suggest that elevated homocysteine or other unknown factors in preeclampsia-like Cth-/- dams interfere with oxytocin that regulates milk ejection reflex.


Assuntos
Cistationina gama-Liase/deficiência , Hiper-Homocisteinemia , Transtornos da Lactação , Pré-Eclâmpsia , Animais , Modelos Animais de Doenças , Feminino , Hiper-Homocisteinemia/enzimologia , Hiper-Homocisteinemia/genética , Hiper-Homocisteinemia/terapia , Transtornos da Lactação/enzimologia , Transtornos da Lactação/genética , Transtornos da Lactação/patologia , Camundongos , Camundongos Knockout , Pré-Eclâmpsia/enzimologia , Pré-Eclâmpsia/genética , Pré-Eclâmpsia/patologia , Gravidez
7.
Int J Artif Organs ; 42(2): 88-94, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30486706

RESUMO

OBJECTIVE:: Extracorporeal circulation devices are coated with a biocompatible polymer coating agent (BPCA) that has a hydrophilic blood-contacting layer, but hemofilters are not. We aimed to investigate the antithrombotic properties of a BPCA-coated hemofilter. METHODS:: Four experiments using BPCA-coated circuits and non-coated hemofilters and four experiments using BPCA-coated circuits and BPCA-coated hemofilters were performed with whole human blood and compared by measuring the circuit pressure every 5 min, antithrombin activity every 40 min, and thrombin-antithrombin complex every 40 min, for a total of 240 min of recirculation. RESULTS:: The mean time required for the pressure at the inlet of the hemofilter to increase sharply was longer in BPCA-coated than in non-coated hemofilters (66 ± 11 min vs 25 ± 9 min, p < 0.01). The mean antithrombin activity value at 200 and 240 min of recirculation was significantly higher in the experiments with BPCA-coated versus non-coated hemofilters (43.3 ± 2.87 vs 33.3 ± 5.74, p = 0.04; 42.8 ± 3.59 vs 31.0 ± 5.35, p = 0.01, respectively); the antithrombin activity values at the other time points were not significantly different. Furthermore, all thrombin-antithrombin complex values in experiments with the BPCA-coated hemofilters achieved overrange at 80 min of recirculation, whereas those with the non-coated hemofilter achieved overrange at 40 min. CONCLUSION:: This study suggests that BPCA-coated hemofilters can inhibit antithrombin consumption, contributing to antithrombotic effects in extracorporeal circulation circuits.


Assuntos
Acrilatos , Coagulação Sanguínea/fisiologia , Materiais Revestidos Biocompatíveis , Hemofiltração/instrumentação , Interações Hidrofóbicas e Hidrofílicas , Polímeros , Trombose/prevenção & controle , Antitrombina III , Antitrombinas , Testes de Coagulação Sanguínea , Humanos , Técnicas In Vitro , Peptídeo Hidrolases , Sulfonas
8.
Interact Cardiovasc Thorac Surg ; 22(2): 155-60, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26573764

RESUMO

OBJECTIVES: To investigate the sterility and biocompatibility of a stored open-reservoir cardiopulmonary bypass circuit maintained on standby. METHODS: A total of four cardiopulmonary bypass circuits were assembled, primed and left to recirculate. One unit was placed in a positive-pressure operating room and the other three were placed in the intensive care unit. The primed solutions, which employed Ringer's acetate, hydroxyethylated starch and hydrate steroid, were sampled after 0, 24, 48, 72, 96, 120 and 144 h in all cardiopulmonary bypass circuits to measure the bacteria count, endotoxin count and chemical substances within the primed solution. Chemical substances were detected by assessing the following: the total organic carbon by the combustion oxidation infrared spectrometry, and molecular weight spread by gel permeation chromatography. The environments were left unattended and were uncovered during the storage period to mimic the clinical scenario. RESULTS: There were no bacteria in any of the primed solutions, and only very minute concentrations of endotoxins were detected, both in the operating room and in the intensive care unit. The total organic carbon concentration was slightly more concentrated in the 144-h samples when compared with that in the 0-h samples. However, the molecular weight spread of the 0-h sample was identical to that in the 144-h sample. DISCUSSION: With regard to the presence of bacteria and endotoxins, we noted that the hardshell reservoirs in the cardiopulmonary bypass circuit were effectively sealed and not invaded by bacteria. With regard to the presence of chemical substances, we noted that an increase in total organic carbon concentration was caused by bedewing, and that there was no release of chemical substances such as a polymer-coating agent, or other molecular materials in the primed solution. CONCLUSIONS: There was no contamination or release of chemical substances in 6-day old cardiopulmonary bypass circuits maintained on standby, confirming that they are safe to use in terms of sterility and biocompatibility.


Assuntos
Ponte Cardiopulmonar/instrumentação , Oxigenadores de Membrana , Desenho de Equipamento , Seguimentos , Humanos , Salas Cirúrgicas , Esterilização , Fatores de Tempo