Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Toxics ; 11(1)2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-36668782

RESUMO

Increasing concern over air pollution has led to the development of low-cost sensors suitable for wide-scale deployment and use by citizen scientists. This project investigated the AirU low-cost particle sensor using two methods: (1) a comparison of pre- and post-deployment calibration equations for 24 devices following use in a field study, and (2) an in-home comparison between 3 AirUs and a reference instrument, the GRIMM 1.109. While differences (and therefore some sensor degradation) were found in the pre- and post-calibration equation comparison, absolute value changes were small and unlikely to affect the quality of results. Comparison tests found that while the AirU did tend to underestimate minimum and overestimate maximum concentrations of particulate matter, ~88% of results fell within ±1 µg/m3 of the GRIMM. While these tests confirm that low-cost sensors such as the AirU do experience some sensor degradation over multiple months of use, they remain a valuable tool for exposure assessment studies. Further work is needed to examine AirU performance in different environments for a comprehensive survey of capability, as well as to determine the source of sensor degradation.

2.
Ann Work Expo Health ; 63(9): 1046-1060, 2019 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-31587049

RESUMO

Based on experiments conducted in low wind speed and calm air environments, the current International Organization for Standardization (ISO) and European Committee for Standardization (CEN) convention modeling human aerosol inhalability (i.e. aspiration efficiency) may not be valid when wind speeds are less than 0.5 ms-1. Additionally, the convention is based primarily on mouth breathing data and aerosols with aerodynamic diameters smaller than 100 µm. Since the convention's development, experimental inhalation data at wind speeds lower than 0.5 ms-1 for nose, mouth, and oronasal breathing have been generated for aerosols in a wider range of sizes (1.5-135 µm). These data were gathered and modeled with the intention of providing a simple convention recommendation for inhalability in low wind speed (>0 to <0.5 ms-1) and calm air (~0 ms-1) conditions to the ISO Technical Committee (TC) 146, Subcommittee 2, Working Group (WG) 1 ('Particle Size-Selective Sampling and Analysis'), as it relates to standard ISO 7708, and to CEN TC 137/WG 3, as it relates to standard EN 481. This paper presents several equations as possibilities, all relating aspiration efficiency to aerodynamic diameter. The equation AE=1+0.000019dae2-0.009788dae stands out as a possible new convention. This polynomial model balances simplicity and fit while addressing the weakness of the current convention.


Assuntos
Movimentos do Ar , Poluentes Ocupacionais do Ar/análise , Monitoramento Ambiental/métodos , Exposição por Inalação/análise , Exposição Ocupacional/análise , Aerossóis/análise , Humanos , Tamanho da Partícula , Vento
3.
J Occup Environ Hyg ; 15(7): 559-567, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29683781

RESUMO

Exposure to occupational aerosols are a known hazard in many industry sectors and can be a risk factor for several respiratory diseases. In this study, a laboratory evaluation of low-cost aerosol sensors, the Dylos DC1700 and a modified Dylos known as the Utah Modified Dylos Sensor (UMDS), was performed to assess the sensors' efficiency in sampling respirable and inhalable dust at high concentrations, which are most common in occupational settings. Dust concentrations were measured in a low-speed wind tunnel with 3 UMDSs, collocated with an aerosol spectrometer (Grimm 1.109) and gravimetric respirable and inhalable samplers. A total of 10 tests consisting of 5 different concentrations and 2 test aerosols, Arizona road dust and aluminum oxide, were conducted. For the Arizona road dust, total particle count was strongly related between the spectrometer and the UMDS with a coefficient of determination (R2) between 0.86-0.92. Particle count concentrations measured with the UMDS were converted to mass and also were related with gravimetrically collected inhalable and respirable dust. The UMDS small bin (i.e., all particles) compared to the inhalable sampler yielded an R2 of 0.86-0.92, and the large bin subtracted from the small bin (i.e., only the smallest particles) compared to the respirable sampler yielded an R2 of 0.93-0.997. Tests with the aluminum oxide demonstrated a substantially lower relationship across all comparisons. Furthermore, assessment of intra-instrument variability was consistent for all instruments, but inter-instrument variability indicated that each instrument requires its own calibration equation to yield accurate exposure estimates. Overall, it appears that the UMDS can be used as a low-cost tool to estimate respirable and inhalable concentrations found in many workplaces. Future studies will focus on deployment of a UMDS network in an occupational setting.


Assuntos
Poluentes Ocupacionais do Ar/análise , Poeira/análise , Monitoramento Ambiental/instrumentação , Material Particulado/análise , Óxido de Alumínio/análise , Arizona , Monitoramento Ambiental/métodos , Exposição Ocupacional/análise , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...