Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Thorac Cardiovasc Surg ; 141(4): 926-31, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20599231

RESUMO

OBJECTIVE: To investigate the results of emergency endovascular repair of complicated Stanford type B aortic dissections within 24 hours of symptom onset. METHODS: A retrospective analysis of the clinical data of 30 patients with complicated Stanford type B aortic dissections who underwent emergency endovascular repair between June 2007 and October 2008. Endovascular repairs were performed within 24 hours of symptom onset. Stent-grafts were deployed at the first entry tear through the femoral artery under fluoroscopic guidance. Follow-up computed tomography scans were performed at 1, 3, 6, 12, and 18 months after treatment. RESULTS: The mean patient age was 64 years (range, 43-83 years). There were 3 cases associated with rupture, 6 cases associated with refractory hypertension, 15 cases associated with persistent pain, 2 cases associated with retrograde dissection, and 4 cases associated with malperfusion. The technical success rate was 100%, and the incidence of immediate postoperative endoleaks was 13.4%. One patient died of dissection rupture within 30 days. The mean follow-up period was 12 ± 8 months. A small, persistent endoleak (<10%) occurred in 1 patient, and 1 patient died of acute liver failure 2 months after the operation. No stent dislocation, false lumen expansion, or paraplegia occurred. The false lumen was completely thrombosed in 6 patients and partially thrombosed in 19 patients. The mortality rate was 6.67%. CONCLUSIONS: Our results suggest that emergency endovascular repair of complicated Stanford type B aortic dissections within 24 hours of symptom onset is associated with good outcomes and can decrease mortality.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Aneurisma Aórtico/complicações , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Ruptura Aórtica/etiologia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , China , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Falência Hepática Aguda/etiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents , Análise de Sobrevida , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...