Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
1.
Radiology ; 311(1): e231461, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38652028

RESUMO

Background Noninvasive tests can be used to screen patients with chronic liver disease for advanced liver fibrosis; however, the use of single tests may not be adequate. Purpose To construct sequential clinical algorithms that include a US deep learning (DL) model and compare their ability to predict advanced liver fibrosis with that of other noninvasive tests. Materials and Methods This retrospective study included adult patients with a history of chronic liver disease or unexplained abnormal liver function test results who underwent B-mode US of the liver between January 2014 and September 2022 at three health care facilities. A US-based DL network (FIB-Net) was trained on US images to predict whether the shear-wave elastography (SWE) value was 8.7 kPa or higher, indicative of advanced fibrosis. In the internal and external test sets, a two-step algorithm (Two-step#1) using the Fibrosis-4 Index (FIB-4) followed by FIB-Net and a three-step algorithm (Three-step#1) using FIB-4 followed by FIB-Net and SWE were used to simulate screening scenarios where liver stiffness measurements were not or were available, respectively. Measures of diagnostic accuracy were calculated using liver biopsy as the reference standard and compared between FIB-4, SWE, FIB-Net, and European Association for the Study of the Liver guidelines (ie, FIB-4 followed by SWE), along with sequential algorithms. Results The training, validation, and test data sets included 3067 (median age, 42 years [IQR, 33-53 years]; 2083 male), 1599 (median age, 41 years [IQR, 33-51 years]; 1124 male), and 1228 (median age, 44 years [IQR, 33-55 years]; 741 male) patients, respectively. FIB-Net obtained a noninferior specificity with a margin of 5% (P < .001) compared with SWE (80% vs 82%). The Two-step#1 algorithm showed higher specificity and positive predictive value (PPV) than FIB-4 (specificity, 79% vs 57%; PPV, 44% vs 32%) while reducing unnecessary referrals by 42%. The Three-step#1 algorithm had higher specificity and PPV compared with European Association for the Study of the Liver guidelines (specificity, 94% vs 88%; PPV, 73% vs 64%) while reducing unnecessary referrals by 35%. Conclusion A sequential algorithm combining FIB-4 and a US DL model showed higher diagnostic accuracy and improved referral management for all-cause advanced liver fibrosis compared with FIB-4 or the DL model alone. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Ghosh in this issue.


Assuntos
Algoritmos , Técnicas de Imagem por Elasticidade , Cirrose Hepática , Humanos , Masculino , Cirrose Hepática/diagnóstico por imagem , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Técnicas de Imagem por Elasticidade/métodos , Adulto , Aprendizado Profundo , Fígado/diagnóstico por imagem , Fígado/patologia , Idoso , Ultrassonografia/métodos
2.
Radiology ; 310(3): e232255, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38470237

RESUMO

Background Large language models (LLMs) hold substantial promise for medical imaging interpretation. However, there is a lack of studies on their feasibility in handling reasoning questions associated with medical diagnosis. Purpose To investigate the viability of leveraging three publicly available LLMs to enhance consistency and diagnostic accuracy in medical imaging based on standardized reporting, with pathology as the reference standard. Materials and Methods US images of thyroid nodules with pathologic results were retrospectively collected from a tertiary referral hospital between July 2022 and December 2022 and used to evaluate malignancy diagnoses generated by three LLMs-OpenAI's ChatGPT 3.5, ChatGPT 4.0, and Google's Bard. Inter- and intra-LLM agreement of diagnosis were evaluated. Then, diagnostic performance, including accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve (AUC), was evaluated and compared for the LLMs and three interactive approaches: human reader combined with LLMs, image-to-text model combined with LLMs, and an end-to-end convolutional neural network model. Results A total of 1161 US images of thyroid nodules (498 benign, 663 malignant) from 725 patients (mean age, 42.2 years ± 14.1 [SD]; 516 women) were evaluated. ChatGPT 4.0 and Bard displayed substantial to almost perfect intra-LLM agreement (κ range, 0.65-0.86 [95% CI: 0.64, 0.86]), while ChatGPT 3.5 showed fair to substantial agreement (κ range, 0.36-0.68 [95% CI: 0.36, 0.68]). ChatGPT 4.0 had an accuracy of 78%-86% (95% CI: 76%, 88%) and sensitivity of 86%-95% (95% CI: 83%, 96%), compared with 74%-86% (95% CI: 71%, 88%) and 74%-91% (95% CI: 71%, 93%), respectively, for Bard. Moreover, with ChatGPT 4.0, the image-to-text-LLM strategy exhibited an AUC (0.83 [95% CI: 0.80, 0.85]) and accuracy (84% [95% CI: 82%, 86%]) comparable to those of the human-LLM interaction strategy with two senior readers and one junior reader and exceeding those of the human-LLM interaction strategy with one junior reader. Conclusion LLMs, particularly integrated with image-to-text approaches, show potential in enhancing diagnostic medical imaging. ChatGPT 4.0 was optimal for consistency and diagnostic accuracy when compared with Bard and ChatGPT 3.5. © RSNA, 2024 Supplemental material is available for this article.


Assuntos
Nódulo da Glândula Tireoide , Humanos , Feminino , Adulto , Nódulo da Glândula Tireoide/diagnóstico por imagem , Estudos Retrospectivos , Idioma , Redes Neurais de Computação , Curva ROC
3.
Adv Sci (Weinh) ; 10(36): e2304132, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37939292

RESUMO

Wearable sensors have garnered considerable attention due to their flexibility and lightweight characteristics in the realm of healthcare applications. However, developing robust wearable sensors with facile fabrication and good conformity remains a challenge. In this study, a conductive graphene nanoplate-carbon nanotube (GC) ink is synthesized for multi jet fusion (MJF) printing. The layer-by-layer fabrication process of MJF not only improves the mechanical and flame-retardant properties of the printed GC sensor but also bolsters its robustness and sensitivity. The direction of sensor bending significantly impacts the relative resistance changes, allowing for precise investigations of joint motions in the human body, such as those of the fingers, wrists, elbows, necks, and knees. Furthermore, the data of resistance changes collected by the GC sensor are utilized to train a support vector machine with a 95.83% accuracy rate for predicting human motions. Due to its stable humidity sensitivity, the sensor also demonstrates excellent performance in monitoring human breath and predicting breath modes (normal, fast, and deep breath), thereby expanding its potential applications in healthcare. This work opens up new avenues for using MJF-printed wearable sensors for a variety of healthcare applications.


Assuntos
Dispositivos Eletrônicos Vestíveis , Humanos , Umidade , Movimento (Física) , Aprendizado de Máquina , Impressão Tridimensional
4.
JAMA Netw Open ; 6(5): e2313674, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-37191957

RESUMO

Importance: To optimize the integration of artificial intelligence (AI) decision aids and reduce workload in thyroid nodule management, it is critical to incorporate personalized AI into the decision-making processes of radiologists with varying levels of expertise. Objective: To develop an optimized integration of AI decision aids for reducing radiologists' workload while maintaining diagnostic performance compared with traditional AI-assisted strategy. Design, Setting, and Participants: In this diagnostic study, a retrospective set of 1754 ultrasonographic images of 1048 patients with 1754 thyroid nodules from July 1, 2018, to July 31, 2019, was used to build an optimized strategy based on how 16 junior and senior radiologists incorporated AI-assisted diagnosis results with different image features. In the prospective set of this diagnostic study, 300 ultrasonographic images of 268 patients with 300 thyroid nodules from May 1 to December 31, 2021, were used to compare the optimized strategy with the traditional all-AI strategy in terms of diagnostic performance and workload reduction. Data analyses were completed in September 2022. Main Outcomes and Measures: The retrospective set of images was used to develop an optimized integration of AI decision aids for junior and senior radiologists based on the selection of AI-assisted significant or nonsignificant features. In the prospective set of images, the diagnostic performance, time-based cost, and assisted diagnosis were compared between the optimized strategy and the traditional all-AI strategy. Results: The retrospective set included 1754 ultrasonographic images from 1048 patients (mean [SD] age, 42.1 [13.2] years; 749 women [71.5%]) with 1754 thyroid nodules (mean [SD] size, 16.4 [10.6] mm); 748 nodules (42.6%) were benign, and 1006 (57.4%) were malignant. The prospective set included 300 ultrasonographic images from 268 patients (mean [SD] age, 41.7 [14.1] years; 194 women [72.4%]) with 300 thyroid nodules (mean [SD] size, 17.2 [6.8] mm); 125 nodules (41.7%) were benign, and 175 (58.3%) were malignant. For junior radiologists, the ultrasonographic features that were not improved by AI assistance included cystic or almost completely cystic nodules, anechoic nodules, spongiform nodules, and nodules smaller than 5 mm, whereas for senior radiologists the features that were not improved by AI assistance were cystic or almost completely cystic nodules, anechoic nodules, spongiform nodules, very hypoechoic nodules, nodules taller than wide, lobulated or irregular nodules, and extrathyroidal extension. Compared with the traditional all-AI strategy, the optimized strategy was associated with increased mean task completion times for junior radiologists (reader 11, from 15.2 seconds [95% CI, 13.2-17.2 seconds] to 19.4 seconds [95% CI, 15.6-23.3 seconds]; reader 12, from 12.7 seconds [95% CI, 11.4-13.9 seconds] to 15.6 seconds [95% CI, 13.6-17.7 seconds]), but shorter times for senior radiologists (reader 14, from 19.4 seconds [95% CI, 18.1-20.7 seconds] to 16.8 seconds [95% CI, 15.3-18.3 seconds]; reader 16, from 12.5 seconds [95% CI, 12.1-12.9 seconds] to 10.0 seconds [95% CI, 9.5-10.5 seconds]). There was no significant difference in sensitivity (range, 91%-100%) or specificity (range, 94%-98%) between the 2 strategies for readers 11 to 16. Conclusions and Relevance: This diagnostic study suggests that an optimized AI strategy in thyroid nodule management may reduce diagnostic time-based costs without sacrificing diagnostic accuracy for senior radiologists, while the traditional all-AI strategy may still be more beneficial for junior radiologists.


Assuntos
Nódulo da Glândula Tireoide , Humanos , Feminino , Adulto , Nódulo da Glândula Tireoide/diagnóstico , Inteligência Artificial , Estudos Retrospectivos , Estudos Prospectivos , Carga de Trabalho , Sensibilidade e Especificidade , Técnicas de Apoio para a Decisão
5.
Adv Mater ; 35(20): e2211598, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36857506

RESUMO

Although 2D materials are widely explored for data storage and neuromorphic computing, the construction of 2D material-based memory devices with optoelectronic responsivity in the short-wave infrared (SWIR) region for in-sensor reservoir computing (RC) at the optical communication band still remains a big challenge. In this work, an electronic/optoelectronic memory device enabled by tellurium-based 2D van der Waals (vdW) heterostructure is reported, where the ferroelectric CuInP2 S6 and tellurium channel endow this device with both the long-term potentiation/depression by voltage pulses and short-term potentiation by 1550 nm laser pulses (a typical wavelength in the conventional fiber optical communication band). Leveraging the rich dynamics, a fully memristive in-sensor RC system that can simultaneously sense, decode, and learn messages transmitted by optical fibers is demonstrated. The reported 2D vdW heterostructure-based memory featuring both the long-term and short-term memory behaviors using electrical and optical pulses in SWIR region has not only complemented the wide spectrum of applications of 2D materials family in electronics/optoelectronics but also paves the way for future smart signal processing systems at the edge.

6.
Radiol Med ; 128(1): 6-15, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36525179

RESUMO

PURPOSE: To establish shear-wave elastography (SWE) combined with contrast-enhanced ultrasound (CEUS) algorithm (SCCA) and improve the diagnostic performance in differentiating focal liver lesions (FLLs). MATERIAL AND METHODS: We retrospectively selected patients with FLLs between January 2018 and December 2019 at the First Affiliated Hospital of Sun Yat-sen University. Histopathology was used as a standard criterion except for hemangiomas and focal nodular hyperplasia. CEUS with SonoVue (Bracco Imaging) and SCCA combining CEUS and maximum value of elastography with < 20 kPa and > 90 kPa thresholds were used for the diagnosis of FLLs. The diagnostic performance of CEUS and SCCA was calculated and compared. RESULTS: A total of 171 FLLs were included, with 124 malignant FLLs and 47 benign FLLs. The area under curve (AUC), sensitivity, and specificity in detecting malignant FLLs were 0.83, 91.94%, and 74.47% for CEUS, respectively, and 0.89, 91.94%, and 85.11% for SCCA, respectively. The AUC of SCCA was significantly higher than that of CEUS (P = 0.019). Decision curves indicated that SCCA provided greater clinical benefits. The SCCA provided significantly improved prediction of clinical outcomes, with a net reclassification improvement index of 10.64% (P = 0.018) and integrated discrimination improvement of 0.106 (P = 0.019). For subgroup analysis, we divided the FLLs into a chronic-liver-disease group (n = 88 FLLs) and a normal-liver group (n = 83 FLLs) according to the liver background. In the chronic-liver-disease group, there were no differences between the CEUS-based and SCCA diagnoses. In the normal-liver group, the AUC of SCCA and CEUS in the characterization of FLLs were 0.89 and 0.83, respectively (P = 0.018). CONCLUSION: SCCA is a feasible tool for differentiating FLLs in patients with normal liver backgrounds. Further investigations are necessary to validate the universality of this algorithm.


Assuntos
Técnicas de Imagem por Elasticidade , Neoplasias Hepáticas , Humanos , Técnicas de Imagem por Elasticidade/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Estudos Retrospectivos , Meios de Contraste , Sensibilidade e Especificidade , Ultrassonografia , Fígado/diagnóstico por imagem , Fígado/patologia , Algoritmos
7.
Chinese Journal of Urology ; (12): 52-55, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-993971

RESUMO

Objective:To develop an improved wireless intelligent capsule cystoscope (WCE)for dynamic detection of bladder mucosa in a pig model.Methods:The WCE was introduced into a healthy experimental pig that under general anesthesia via urethra by applying an improved device. Multi-angle images of the bladder mucosa were then obtained by controlling the position of capsule cystoscope with an external magnetic field system. The shutter speed of the WCE was 2.5 fps and was automatically converted to 1.5 fps 30 minutes after initiation. The Vue software was utilized to download the shoot pictures which were former received by a computer via wireless transmission. The pig was roused and sent to the pigpen, without limitations in moving. The improved WCE was connected with a 2 cm thread. 12 hours later, the dilated sheath was inserted again, and the capsule was removed by a foreign body forceps under observation of a ureteroscopy.Results:The WCE was successfully placed and removed from the pig's bladder with the application of the improved devices. Over 20 thousand images that with 60K pixels of bladder mucosa were captured by the WCE at various angles within 12 hours, which revealed the process of urine filling and excreting in a time-dependent way. No notable adverse effects (bleeding, urinary tract injury, etc) were noted during the process of cystoscope placement, image acquisition, transmission, and removal.Conclusion:This study developed a novel WCE that could dynamically, intelligently and accurately monitor all aspects of the pig bladder mucosa, and has preferable application prospect.

8.
BMC Gastroenterol ; 22(1): 517, 2022 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-36513975

RESUMO

OBJECTIVE: The main aim of this study was to analyze the performance of different artificial intelligence (AI) models in endoscopic colonic polyp detection and classification and compare them with doctors with different experience. METHODS: We searched the studies on Colonoscopy, Colonic Polyps, Artificial Intelligence, Machine Learning, and Deep Learning published before May 2020 in PubMed, EMBASE, Cochrane, and the citation index of the conference proceedings. The quality of studies was assessed using the QUADAS-2 table of diagnostic test quality evaluation criteria. The random-effects model was calculated using Meta-DISC 1.4 and RevMan 5.3. RESULTS: A total of 16 studies were included for meta-analysis. Only one study (1/16) presented externally validated results. The area under the curve (AUC) of AI group, expert group and non-expert group for detection and classification of colonic polyps were 0.940, 0.918, and 0.871, respectively. AI group had slightly lower pooled specificity than the expert group (79% vs. 86%, P < 0.05), but the pooled sensitivity was higher than the expert group (88% vs. 80%, P < 0.05). While the non-experts had less pooled specificity in polyp recognition than the experts (81% vs. 86%, P < 0.05), and higher pooled sensitivity than the experts (85% vs. 80%, P < 0.05). CONCLUSION: The performance of AI in polyp detection and classification is similar to that of human experts, with high sensitivity and moderate specificity. Different tasks may have an impact on the performance of deep learning models and human experts, especially in terms of sensitivity and specificity.


Assuntos
Pólipos do Colo , Humanos , Pólipos do Colo/diagnóstico , Inteligência Artificial , Colonoscopia/métodos , Sensibilidade e Especificidade , Área Sob a Curva
9.
Nanomaterials (Basel) ; 12(21)2022 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-36364652

RESUMO

Stability of advanced functional materials subjected to extreme conditions involving ion bombardment, radiation, or reactive chemicals is crucial for diverse applications. Here we demonstrate the excellent stability of wafer-scale thin films of vertically aligned hexagonal BN nanosheets (hBNNS) exposed to high-energy ions and reactive atomic oxygen representative of extreme conditions in space exploration and other applications. The hBNNS are fabricated catalyst-free on wafer-scale silicon, stainless steel, copper and glass panels at a lower temperature of 400 °C by inductively coupled plasma (ICP) assisted chemical vapor deposition (CVD) and subsequently characterized. The resistance of BNNS to high-energy ions was tested by immersing the samples into the plasma plume at the anode of a 150 W Hall Effect Thruster with BNNS films facing Xenon ions, revealing that the etching rate of BNNS is 20 times less than for a single-crystalline silicon wafer. Additionally, using O2/Ar/H2 plasmas to simulate the low Earth orbit (LEO) environment, it is demonstrated that the simulated plasma had very weak influence on the hBNNS surface structure and thickness. These results validate the strong potential of BNNS films for applications as protective, thermally conductive and insulating layers for spacecrafts, electric plasma satellite thrusters and semiconductor optoelectronic devices.

10.
BMC Med Imaging ; 22(1): 186, 2022 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-36309665

RESUMO

OBJECTIVES: To compare the diagnostic performance of the Contrast-Enhanced Ultrasound (CEUS) Liver Imaging Report and Data System (LI-RADS) v2016 and v2017 in identifying the origin of tumor in vein (TIV). METHODS: From April 2014 to December 2018, focal liver lesions (FLLs) accompanied by TIV formation in patients at high risk for hepatocellular carcinoma (HCC) were enrolled. Histologic evaluation or composite imaging reference standard were served as the reference standard. Each case was categorized according to the CEUS LI-RADS v2016 and v2017, respectively. Diagnostic performance of CEUS LI-RADS v2016 and v2017 in identifying the originated tumor of TIV was validated via sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value. RESULTS: A total of 273 FLLs with TIV were analyzed finally, including 266 HCCs and 7 non-HCCs. In v2016, when adopting all TIV as LR-5V, the accuracy and PPV in identifying the originated tumor were both 97.4%. In v2017, when assigning TIV according to contiguous FLLs CEUS LI-RADS category, the accuracy and PPV were 61.9% and 99.4% in subclass of LR-5 as the diagnostic criteria of HCC, and 64.1% and 99.4% in subclass of LR-4/5 as the criteria of HCC diagnosis. There were significant differences in diagnostic accuracy between CEUS LI-RADS v2016 and v2017 in identifying the originated tumor of TIV (p < 0.001). CONCLUSIONS: CEUS LI-RADS v2016 could be better than v2017 in identifying the originated tumor of TIV.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Br J Radiol ; 95(1139): 20211137, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36165329

RESUMO

METHODS: Between December 2017 and December 2018, 153 HCC patients (134 males and 19 females; mean age, 56.0 ± 10.2 years; range, 28-78 years) treated with radical therapy were enrolled in our retrospective study and were divided into a training cohort (n = 107) and a validation cohort (n = 46). All patients underwent preoperative CTC tests and CEUS examinations before treatment. The ultrasomics signature was extracted and built from CEUS images. Univariate and multivariate logistic regression analyses were used to identify the significant variables related to ER, which were then combined to build a predictive nomogram. The performance of the nomogram was evaluated by its discrimination, calibration and clinical utility. The predictive model was further evaluated in the internal validation cohort. RESULTS: HBV DNA, serum AFP level, CTC status, tumour size and ultrasomics score were identified as independent predictors associated with ER (all p < 0.05). Multivariable logistic regression analysis showed that the CTC status (OR = 7.02 [95% CI, 2.07 to 28.38], p = 0.003) and ultrasomics score (OR = 148.65 [95% CI, 25.49 to 1741.72], p < 0.001) were independent risk factors for ER. The nomogram based on ultrasomics score, CTC status, serum AFP level and tumour size exhibited C-indexes of 0.933 (95% CI, 0.878 to 0.988) and 0.910 (95% CI, 0.765 to 1.055) in the training and validation cohorts, respectively, fitting well in calibration curves. Decision curve analysis further confirmed the clinical usefulness of the nomogram. CONCLUSION: The nomogram incorporating CTC, ultrasomics features and independent clinical risk factors achieved satisfactory preoperative prediction of ER in HCC patients after radical treatment. ADVANCES IN KNOWLEDGE: 1. CTC status and ultrasomics score were identified as independent predictors associated with ER of HCC after radical treatment. 2. The nomogram constructed by ultrasomics score generated by 17 ultrasomics features, combined with CTCs and independent clinical risk factors such as AFP and tumour size. 3. The nomogram exhibited satisfactory discriminative power, and could be clinically useful in the preoperative prediction of ER after radical treatment in HCC patients.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Células Neoplásicas Circulantes , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , alfa-Fetoproteínas/análise , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/genética , Carcinoma Hepatocelular/cirurgia , DNA Viral , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/genética , Neoplasias Hepáticas/cirurgia , Nomogramas , Estudos Retrospectivos , Adulto
12.
J Hepatocell Carcinoma ; 9: 437-451, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35620274

RESUMO

Purpose: The contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS) treatment response algorithm (TRA) is still in development. The aim of this study was to explore whether the CT/MRI LI-RADS TRA features were applicable to CEUS in evaluating the liver locoregional therapy (LRT) response. Patients and Methods: This study was a retrospective review of a prospectively maintained database of patients with hepatocellular carcinoma undergoing ablation between July 2017 and December 2018. The standard criteria for a viable lesion were a histopathologically confirmed or typical viable appearance in the follow-up CT/MRI. Performance of the LI-RADS TRA assessing tumor viability was then compared between CEUS and CT/MRI. Inter-reader association was calculated. Results: A total of 244 patients with 389 treated observations (118 viable) were evaluated. The sensitivity and specificity of the CEUS TRA and CT/MRI LI-RADS TRA viable categories for predicting viable lesions were 55.0% (65/118) versus 56.8% (67/118) (P = 0.480) and 99.3% (269/271) versus 96.3% (261/271) (P = 0.013), respectively. The PPV of CEUS was higher than that of CT/MRI (97.0% vs 87.0%). Subgroup analysis showed that the sensitivity was low in the 1-month assessment for both CEUS (38.1%, 16/42) and CT/MR (47.6%, 20/42) and higher in the 2-6-month assessment for both CEUS (65.7%, 23/35) and CT/MR (62.9%, 22/35). Interobserver agreements were substantial for both CEUS TRA and CT/MRI LI-RADS TRA (κ, 0.74 for both). Conclusion: The CT/MRI LI-RADS TRA features were applicable to CEUS TRA for liver locoregional therapy. The CEUS TRA for liver locoregional therapy has sufficiently high specificity and PPV to diagnose the viability of lesions after ablation.

13.
Eur Radiol ; 32(9): 5843-5851, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35314881

RESUMO

OBJECTIVES: To systematically assess the reproducibility of radiomics features from ultrasound (US) images during image acquisition and processing. MATERIALS AND METHODS: A standardized phantom was scanned to obtain US images. Reproducibility of radiomics features from US images, also known as ultrasomics features, was explored via (a) intra-US machine: changing the US acquisition parameters including gain, focus, and frequency; (b) inter-US machine: comparing three different scanners; (c) changing segmentation locations; and (d) inter-platform: comparing features extracted by the Ultrasomics and PyRadiomics algorithm platforms. Reproducible ultrasomics features were selected based on coefficients of variation. RESULTS: A total of 108 US images from three scanners were obtained; 5253 ultrasomics features including seven categories of features were extracted and evaluated for each US image. From intra-US machine analysis, 37.0-38.8% of features showed good reproducibility. From inter-US machine analysis, 42.8% (2248/5253) of features exhibited good reproducibility. From segmentation location analysis, 55.7-57.6% of features showed good reproducibility. No significant difference in the normalized feature ranges was found between the 100 features extracted by the Ultrasomics and PyRadiomics platforms with the same algorithm (p = 0.563). A total of 1452 (27.6%) ultrasomics features were reproducible whenever intra-/inter-US machine or segmentation location were changed, most of which were wavelet and shearlet features. CONCLUSIONS: Different acquisition parameters, US scanners, segmentation locations, and feature extraction platforms affected the reproducibility of ultrasomics features. Wavelet and shearlet features showed the best reproducibility across all procedures. KEY POINTS: • Different acquisition parameters, US scanners, segmentation locations, and feature extraction platforms affected the reproducibility of ultrasomics features. • A total of 1452 (27.6%) ultrasomics features were reproducible whenever intra-/inter-US machine or segmentation location were changed. • Wavelet and shearlet features showed the best reproducibility across all procedures.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Ultrassonografia
14.
Nanomaterials (Basel) ; 12(4)2022 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-35214969

RESUMO

A rapid and one-pot synthesis of poly 3-thiopheneacetic acid (PTAA) functionalized polyurea polymer dots (Pdots) using polyethyleneimine and isophorone diisocyanate is reported. The one-pot mini-emulsion polymerization technique yielded Pdots with an average diameter of ~20 nm. The size, shape, and concentration of the surface functional groups could be controlled by altering the synthesis parameters such as ultrasonication time, concentration of the surfactant, and crosslinking agent, and the types of isocyanates utilized for the synthesis. Colloidal properties of Pdots were characterized using dynamic light scattering and zeta potential measurements. The spherical geometry of Pdots was confirmed by scanning electron microscopy. The Pdots were post-functionalized by 1,4,7,10 tetraazacyclododecane-1,4,7,10-tetraacetic acid for chelating gadolinium nanoparticles (Gd3+) that provide magnetic properties to the Pdots. Thus, the synthesized Pdots possess fluorescent and magnetic properties, imparted by PTAA and Gd3+, respectively. Fluorescence spectroscopy and microscopy revealed that the synthesized dual-functional Gd3+-Pdots exhibited detectable fluorescent signals even at lower concentrations. Magnetic levitation experiments indicated that the Gd3+-Pdots could be easily manipulated via an external magnetic field. These findings illustrate that the dua- functional Gd3+-Pdots could be potentially utilized as fluorescent reporters that can be magnetically manipulated for bioimaging applications.

15.
Abdom Radiol (NY) ; 47(4): 1311-1320, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35122491

RESUMO

PURPOSE: To improve noninvasive diagnosis of HCC using a combination of CE US LI-RADS and alpha-fetoprotein (AFP). METHODS: 757 solitary liver nodules from 757 patients at risk of HCC with CE US and serum AFP test were categorized as LR-1 to LR-5 through LR-M according to CE US LI-RADS version 2017. In LR-3, LR-4, and LR-M nodules, those with AFP > 200 ng/ml were reclassified as mLR-5. Nodules with LR-5 and mLR-5 were reclassified as definitely HCC to modify CE US LI-RADS. Diagnostic performance was assessed with specificity, sensitivity, and PPV. RESULTS: The sensitivity, specificity, and PPV of LR-5 as a predictor of HCC were 64.7%, 97.8%, and 98.9%, respectively. 32.1% patients with solitary liver nodule had AFP greater than 200 ng/ml, of which 98.8% were HCC (25.8%, 7.5%, 2.5% assigned to LR-M, LR-4, LR-3, respectively) and 1.2% were Combined Hepatocellular Cholangiocarcinoma. After modification, the sensitivity increased to 79.6% (P < 0.001), while specificity and PPV remained high (96.6% and 98.7%, P > 0.050). CONCLUSION: The combination of CE US LI-RADS and AFP for diagnosing HCC improved diagnostic sensitivity significantly, while maintaining high PPV and specificity in patients with the solitary liver nodule.


Assuntos
Neoplasias dos Ductos Biliares , Carcinoma Hepatocelular , Neoplasias Hepáticas , Ductos Biliares Intra-Hepáticos , Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Sensibilidade e Especificidade , alfa-Fetoproteínas
16.
Kidney Int Rep ; 7(1): 56-67, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35005314

RESUMO

INTRODUCTION: Patients with glomerular disease experience symptoms that impair their physical and mental health while managing their treatments, diet, appointments and monitoring general and specific indicators of health and their illness. We sought to describe the perspectives of patients and their care partners on self-management in glomerular disease. METHODS: We conducted 16 focus groups involving adult patients with glomerular disease (n = 101) and their care partners (n = 34) in Australia, Hong Kong, the United Kingdom, and United States. Transcripts were analyzed thematically. RESULTS: We identified the following 4 themes: empowered in autonomy (gaining confidence through understanding, taking ownership of disease and treatment, learning a positive health approach); overwhelmed by compounding treatment burdens (financially undermined and depleted, demoralized by side effects and harms, frustrated by fragmented and inflexible care, fear of possible drug harms); striving for stability and normalcy (making personal sacrifices, maximizing life participation, attentiveness to bodily signs, avoiding precarious health states, integrating medicines into routines); and necessity of health-sustaining relationships (buoyed by social support, fulfilling meaningful responsibilities, sharing and normalizing experiences, seeking a trusting and respectful alliance). CONCLUSION: Patients with glomerular disease and their care partners value their capacity for autonomy and disease ownership, stability of their health, and relationships that support self-management. Strategies directed at strengthening these factors may increase self-efficacy and improve the care and outcomes for patients with glomerular disease.

17.
Radiol Med ; 127(1): 1-10, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34665430

RESUMO

PURPOSE: Using contrast-enhanced ultrasound (CEUS) to evaluate the diagnostic performance of liver imaging reporting and data system (LI-RADS) version 2017 and to explore potential ways to improve the efficacy. METHODS: A total of 315 nodules were classified as LR-1 to LR-5, LR-M, and LR-TIV. New criteria were applied by adjusting the early washout onset (< 45 s) and the time of marked washout (within 3 min). Two subgroups of the LR-M nodules were recategorized as LR-5, respectively. The diagnostic performance was evaluated by calculating the accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). RESULTS: By adjusting early washout onset to < 45 s, the LR-5 as a standard for diagnosing HCC had an improved sensitivity (74.1% vs. 56.1%, P < 0.001) without significant change in PPV (93.3% vs. 96.1%, P = 0.267), but the specificity was decreased (48.3% vs. 78.5%, P = 0.018). The LR-M as a standard for the diagnosis of non-HCC malignancies had an increase in specificity (89.2% vs. 66.2%, P < 0.001) but a decrease in sensitivity (31.5% vs. 68.4%, P = 0.023). After reclassification according to the time of marked washout, the sensitivity of the LR-5 increased (80% vs. 56.1%, P < 0.001) without a change in PPV (94.9% vs. 96.1%, P = 0.626) and specificity (80% vs. 78.5%, P = 0.879). For reclassified LR-M nodules, the specificity increased (87.5% versus 66.2%, P < 0.001) with a non-significant decrease in sensitivity (47.3% vs. 68.4%, P = 0.189). CONCLUSIONS: The CEUS LI-RADS showed good confidence in diagnosing HCC while tended to misdiagnose HCC as non-HCC malignancies. Adjusting the marked washout time within 3 min would reduce the possibility of this misdiagnosis.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Sistemas de Informação em Radiologia/estatística & dados numéricos , Ultrassonografia/métodos , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
18.
J Ultrasound Med ; 41(8): 1925-1938, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34751450

RESUMO

PURPOSES: To evaluate the postsurgical prognostic implication of contrast-enhanced ultrasound (CEUS) for combined hepatocellular-cholangiocarcinoma (CHC). To build a CEUS-based early recurrence prediction classifier for CHC, in comparison with tumor-node-metastasis (TNM) staging. METHODS: The CEUS features and clinicopathological findings of each case were analyzed, and the Liver Imaging Reporting and Data System categories were assigned. The recurrence-free survival associated factors were evaluated by Cox proportional hazard model. Incorporating the independent factors, nomograms were built to estimate the possibilities of 3-month, 6-month, and 1-year recurrence and whose prognostic value was determined by time-dependent receiver operating characteristics, calibration curves, and hazard layering efficiency validation, comparing with TNM staging system. RESULTS: In the multivariable analysis, the levels of carbohydrate antigen 19-9, prothrombin time and total bilirubin, and tumor shape, the Liver Imaging Reporting and Data System category were independent factors for recurrence-free survival. The LR-M category showed longer recurrence-free survival than did the LR-4/5 category. The 3-month, 6-month, and 1-year area under the curves of the CEUS-clinical nomogram, clinical nomogram, and TNM staging system were 0.518, 0.552, and 0.843 versus 0.354, 0.240, and 0.624 (P = .048, .049, and .471) vs. 0.562, 0.545, and 0.843 (P = .630, .564, and .007), respectively. The calibration curves of the CEUS-clinical model at different prediction time pionts were all close to the ideal line. The CEUS-clinical model effectively stratified patients into groups of high and low risk of recurrence in both training and validation set, while the TNM staging system only works on the training set. CONCLUSIONS: Our CEUS-clinical nomogram is a reliable early recurrence prediction tool for hepatocellular-cholangiocarcinoma and helps postoperative risk stratification.


Assuntos
Neoplasias dos Ductos Biliares , Carcinoma Hepatocelular , Colangiocarcinoma , Neoplasias Hepáticas , Nomogramas , Neoplasias dos Ductos Biliares/patologia , Ductos Biliares Intra-Hepáticos/patologia , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Colangiocarcinoma/diagnóstico por imagem , Colangiocarcinoma/patologia , Colangiocarcinoma/cirurgia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Estudos Retrospectivos
19.
Br J Radiol ; 95(1130): 20210748, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34797687

RESUMO

OBJECTIVES: This study aimed to construct a prediction model based on contrast-enhanced ultrasound (CEUS) ultrasomics features and investigate its efficacy in predicting early recurrence (ER) of primary hepatocellular carcinoma (HCC) after resection or ablation. METHODS: This study retrospectively included 215 patients with primary HCC, who were divided into a developmental cohort (n = 139) and a test cohort (n = 76). Four representative images-grayscale ultrasound, arterial phase, portal venous phase and delayed phase-were extracted from each CEUS video. Ultrasomics features were extracted from tumoral and peritumoral area inside the region of interest. Logistic regression was used to establish models, including a tumoral model, a peritumoral model and a combined model with additional clinical risk factors. The performance of the three models in predicting recurrence within 2 years was verified. RESULTS: The combined model performed best in predicting recurrence within 2 years, with an area under the curve (AUC) of 0.845, while the tumoral model had an AUC of 0.810 and the peritumoral model one of 0.808. For prediction of recurrence-free survival, the 2-year cumulative recurrence rate was significant higher in the high-risk group (76.5%) than in the low-risk group (9.5%; p < 0.0001). CONCLUSION: These CEUS ultrasomics models, especially the combined model, had good efficacy in predicting early recurrence of HCC. The combined model has potential for individual survival assessment for HCC patients undergoing resection or ablation. ADVANCES IN KNOWLEDGE: CEUS ultrasomics had high sensitivity, specificity and PPV in diagnosing early recurrence of HCC, and high efficacy in predicting early recurrence of HCC (AUC > 0.8). The combined model performed better than the tumoral ultrasomics model and peritumoral ultrasomics model in predicting recurrence within 2 years. Recurrence was more likely to occur in the high-risk group than in the low-risk group, with 2-year cumulative recurrence rates, respectively, 76.5% and 9.5% (p < 0.0001).


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Neoplasias Hepáticas/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico por imagem , Ultrassonografia/métodos , Carcinoma Hepatocelular/cirurgia , Métodos Epidemiológicos , Feminino , Humanos , Aumento da Imagem/métodos , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
20.
Front Oncol ; 11: 704218, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34646763

RESUMO

OBJECTIVE: To explore a new method for color image analysis of ultrasomics and investigate the efficiency in differentiating focal liver lesions (FLLs) by Red, Green, and Blue (RGB) three-channel SWE-based ultrasomics model. METHODS: One hundred thirty FLLs were randomly divided into training set (n = 65) and validation set (n = 65). The RGB three-channel and direct conversion methods were applied to the same color SWE images. Ultrasomics features were extracted from the preprocessing images establishing two feature data sets. The least absolute shrinkage and selection operator (LASSO) logistic regression model was applied for feature selection and model construction. Two models, named RGB model (based on RGB three-channel conversion) and direct model (based on direct conversion), were used to differentiate FLLs. The diagnosis performance of the two models was evaluated by area under the curve (AUC), calibration curves, decision curves, and net reclassification index (NRI). RESULTS: In the validation cohort, the AUC of the direct model and RGB model in characterization on FLLs were 0.813 and 0.926, respectively (p = 0.038). Calibration curves and decision curves indicated that the RGB model had better calibration efficiency and provided greater clinical benefits. NRI revealed that the RGB model correctly reclassified 7% of malignant cases and 25% of benign cases compared to the direct model (p = 0.01). CONCLUSION: The RGB model generated by RGB three-channel method yielded better diagnostic efficiency than the direct model established by direct conversion method. The RGB three-channel method may be promising on ultrasomics analysis of color images in clinical application.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...