1.
J Bone Joint Surg Br ; 89(7): 915-8, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17673585

RESUMO

We have studied the concept of posterior condylar offset and the importance of its restoration on the maximum range of knee flexion after posterior-cruciate-ligament-retaining total knee replacement (TKR). We measured the difference in the posterior condylar offset before and one year after operation in 69 patients who had undergone a primary cruciate-sacrificing mobile bearing TKR by one surgeon using the same implant and a standardised operating technique. In all the patients true pre- and post-operative lateral radiographs had been taken. The mean pre- and post-operative posterior condylar offset was 25.9 mm (21 to 35) and 26.9 mm (21 to 34), respectively. The mean difference in posterior condylar offset was + 1 mm (-6 to +5). The mean pre-operative knee flexion was 111 degrees (62 degrees to 146 degrees) and at one year postoperatively, it was 107 degrees (51 degrees to 137 degrees). There was no statistical correlation between the change in knee flexion and the difference in the posterior condylar offset after TKR (Pearson correlation coefficient r = -0.06, p = 0.69).


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho/fisiopatologia , Ligamento Cruzado Posterior/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Ligamento Cruzado Posterior/diagnóstico por imagem , Radiografia , Resultado do Tratamento
2.
Hip Int ; 17(4): 194-204, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-19197868

RESUMO

We report a series of 706 patients (759 hip implants) with an average follow up of 10.5 years (range, 10-11 years) following total hip replacement (THR) using a cemented custom-made femoral stem and a cemented HDP acetabular component. The fate of every implant is known. One hundred and seventy-four patients (23%) were deceased at the time of their 10-year review all died with a functioning THR in situ. Four hundred and sixty-two patients (61%) were subsequently reviewed. One hundred and twenty three patients (16%) were assessed by telephone review, as they were too ill or unwilling to attend. Kaplan-Meier survival analysis (all components) demonstrated a median survival at 10 years of 96.05% or 95% Confidence Intervals (CI) for median survival of (94.41% to 97.22%). Revision surgery occurred in 30 cases (3.9%). Seventeen had full revisions (2.2%) and 13 (1.7%) socket revisions only. Twenty-one out of 30 revisions were for infection or dislocation. There were 2 cases (0.3%) of revision for aseptic loosening of the stem. The 10-year results of the custom femoral titanium stem are encouraging and compare well with other cemented systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...