Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 121
Filtrar
1.
JSES Int ; 7(3): 493-498, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37266168

RESUMO

Background: Glenoid loosening remains a concern in anatomical total shoulder replacement. Preoperative planning software allows optimization of the component positioning, but the target orientation remains unclear due to conflicting optimization priorities. Commonly, the component is aligned to the prescribed version and inclination that reflect the population's average anatomy. The freehand technique attempts to secure strong fixation by aiming to preserve the subchondral bone. This study compared the state of the subchondral plate after reaming and compared the results of these two techniques. Methods: Two groups of shoulder computed tomography scans were assessed, 34 normal and 34 osteoarthritic. Preoperative planning software was used to place the glenoid component in prescribed adjusted angles, with neutral (0o,0o), retroverted (-10o,0o) and inclined alignment (0o,10o). The computed tomography Hounsfield values at the virtually reamed surface were assessed to determine the percentage of the intended component-bone interface consisting of cortical bone, here termed "cortical bone seating". This was then compared to positioning the component using a freehand technique. Results: The freehand technique improved cortical bone seating in the osteoarthritic group with a mean (standard deviation) of 53.3% (14.3), while neutral alignment resulted in 36.7% (10.8), retroversion 40.4% (13.1), and inclination 39.3% (13.5), P < .001. A similar trend was observed in the normal group. Conclusions: The freehand method resulted in significantly improved cortical bone seating compared to the prescribed adjusted angles. These findings question the use of a one-size-fits-all-orientation and suggest that applying a technique that aims for maximum cortical fixation (freehand) may reduce the risk of aseptic loosening.

2.
Life (Basel) ; 13(6)2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37374160

RESUMO

Bone mechanics is well understood at every length scale except the nano-level. We aimed to investigate the relationship between bone nanoscale and tissue-level mechanics experimentally. We tested two hypotheses: (1) nanoscale strains were lower in hip fracture patients versus controls, and (2) nanoscale mineral and fibril strains were inversely correlated with aging and fracture. A cross-sectional sample of trabecular bone sections was prepared from the proximal femora of two human donor groups (aged 44-94 years): an aging non-fracture control group (n = 17) and a hip-fracture group (n = 20). Tissue, fibril, and mineral strain were measured simultaneously using synchrotron X-ray diffraction during tensile load to failure, then compared between groups using unpaired t-tests and correlated with age using Pearson's correlation. Controls exhibited significantly greater peak tissue, mineral, and fibril strains than the hip fracture (all p < 0.05). Age was associated with a decrease in peak tissue (p = 0.099) and mineral (p = 0.004) strain, but not fibril strain (p = 0.260). Overall, hip fracture and aging were associated with changes in the nanoscale strain that are reflected at the tissue level. Data must be interpreted within the limitations of the observational cross-sectional study design, so we propose two new hypotheses on the importance of nanomechanics. (1) Hip fracture risk is increased by low tissue strain, which can be caused by low collagen or mineral strain. (2) Age-related loss of tissue strain is dependent on the loss of mineral but not fibril strain. Novel insights into bone nano- and tissue-level mechanics could provide a platform for the development of bone health diagnostics and interventions based on failure mechanisms from the nanoscale up.

3.
Clin Biomech (Bristol, Avon) ; 107: 106032, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37348206

RESUMO

BACKGROUND: In vivo evaluation of ankle joint biomechanics is key to investigating the effect of injuries on the mechanics of the joint and evaluating the effectiveness of treatments. The objectives of this study were to 1) investigate the kinematics and contact strains of the ankle joint and 2) to investigate the correlation between the tibiotalar joint contact strains and the prevalence of osteochondral lesions of the talus distribution. METHODS: Eight healthy human ankle joints were subjected to compressive load and 3 T MRIs were obtained before and after applying load. The MR images in combination with digital volume correlation enabled non-invasive measurement of ankle joint kinematics and tibiotalar joint contact strains in three dimensions. FINDINGS: The total translation of the calcaneus was smaller (0.48 ± 0.15 mm, p < 0.05) than the distal tibia (0.93 ± 0.16 mm) and the talus (1.03 ± 0.26 mm). These movements can produce compressive and shear joint contact strains (approaching 9%), which can cause development of lesions on joints. 87.5% of peak tensile, compressive, and shear strains in the tibiotalar joint took place in the medial and lateral zones. INTERPRETATION: The findings suggested that ankle bones translate independently from each other, and in some cases in opposite directions. These findings help explain the distribution of osteochondral lesions of the talus which have previously been observed to be in medial and lateral regions of the talar dome in 90% of cases. They also provide a reason for the central region of talar dome being less susceptible to developing osteochondral lesions.


Assuntos
Articulação do Tornozelo , Tálus , Humanos , Articulação do Tornozelo/diagnóstico por imagem , Tornozelo , Fenômenos Biomecânicos , Tálus/diagnóstico por imagem , Imageamento por Ressonância Magnética
4.
J Mech Behav Biomed Mater ; 138: 105573, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36525874

RESUMO

Measurement of the properties of bone as a material can happen in various length scales in its hierarchical and composite structure. The aim of this study was to test the tissue level properties of clinically-relevant human bone samples which were collected from donors belonging to three groups: ageing donors who suffered no fractures (Control); untreated fracture patients (Fx-Untreated) and patient who experienced hip fracture despite being treated with bisphosphonates (Fx-BisTreated). Tissue level properties were assessed by (a) nanoindentation and (b) synchrotron tensile tests (STT) where strains were measured at the 'tissue', 'fibril' and 'mineral' levels by using simultaneous Wide-angle - (WAXD) and Small angle- X-ray diffraction (SAXD). The composition was analysed by thermogravimetric analysis and material level endo- and exo-thermic reactions by differential scanning calorimetry (TGA/DSC3+). Irrespective of treatment fracture donors exhibited significantly lower tissue, fibril and mineral strain at the micro and nanoscale respectively and had a higher mineral content than controls. In nanoindentation only nanohardness was significantly greater for Controls and Fx-BisTreated versus Fx-Untreated. The other nanoindentation parameters did not vary significantly across the three groups. There was a highly significant positive correlation (p < 0.001) between organic content and tissue level strain behaviour. Overall hip-fractures were associated with lower STT nanostrains and it was behaviour measured by STT which proved to be a more effective approach for predicting fracture risk because evidently it was able to demonstrate the mechanical deficit for the bone tissue of the donors who had experienced fractures.


Assuntos
Osso e Ossos , Fraturas do Quadril , Humanos , Envelhecimento , Difração de Raios X , Minerais , Densidade Óssea
5.
J Mech Behav Biomed Mater ; 136: 105468, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36244325

RESUMO

The bone quality of patients undergoing hip replacement surgery is poorly predicted by radiographs alone. With better bone quality information available to a surgeon, the operation can be performed more safely. The aim of this study was to investigate whether ultrasound signals of cortical bone at peripheral sites such as the tibia and radius can be used to predict the compressive mechanical properties of cortical bone at the femoral neck. We recruited 19 patients undergoing elective hip arthroplasty and assessed the radius and tibia of these patients with the Azalée guided wave ultrasound to estimate the porosity and thickness of the cortex. Excess bone tissues were collected from the femoral neck and the compressive mechanical properties of the cortex were characterised under a mechanical loading rig to determine stiffness, ultimate strength, and density. The correlations between the ultrasound measurements and mechanical properties were analysed using linear regression, Pearson correlation statistics, and multiple regression analysis. Cortical mechanical properties were weakly to moderately correlated with the ultrasound measurements at various sites (R2 = 0.00-0.36). The significant correlations found were not consistent across all 4 peripheral measurement sites. Additionally, weak to moderate ability of the ultrasound to predict mechanical properties at the neck of femur with multiple regression analysis was found (R2 = 0.00-0.48). Again, this was inconsistent across the different anatomical sites. Overall, the results demonstrate the need for ultrasound scans to be collected directly from clinically relevant sites such as the femoral neck due to the inconsistency of mechanical properties across various sites.


Assuntos
Artroplastia de Quadril , Colo do Fêmur , Humanos , Colo do Fêmur/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Osso Cortical , Radiografia , Densidade Óssea
6.
Front Plant Sci ; 13: 989484, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36311146

RESUMO

Despite a much later inception of somatic embryogenesis (SE) propagation protocols for gymnosperms than for angiosperm species, SE is becoming increasingly important due to its applications for commercial forestry. For many conifers, there are however still major bottlenecks in the SE plant production process limiting the use of SE for forestry operations, Christmas tree production and research projects. In the present case study, the effects on plant growth from different cultural factors applied during the SE developmental process were studied in two conifer species of high value for Christmas tree production. Seven clones of Abies nordmanniana and two clones of Abies bornmuelleriana were included in the study. Accumulated effects from cultural treatments were recorded from the start of germination of mature embryos of different quality scores through development into plants in the third growing period. Experimental factors of the cultural treatments included were: germination temperature, germination time, light conditions, survival ex vitro and traits for plant growth and vitality. The results reveal that most of the studied experimental factors influenced plant growth during the first three years however their relative importance was different. Plant survival rate at end of the nursery stage was strongly impacted by germination temperature (p<0.001), initial embryo score (p=0.007), clone (p<0.001) and to a lesser extend week of germination (p=0.017). This case-study highlights and quantifies the strong interrelation between the developmental steps of somatic embryogenesis and show the importance of considering all cultural steps when optimizing SE plant production protocols.

7.
J Mech Behav Biomed Mater ; 124: 104806, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34509906

RESUMO

An unresolved challenge in osteoarthritis research is characterising the localised intra-tissue mechanical response of articular cartilage. The aim of this study was to explore whether laboratory micro-computed tomography (micro-CT) and digital volume correlation (DVC) permit non-destructive quantification of three-dimensional (3D) strain fields in human articular cartilage. Human articular cartilage specimens were harvested from the knee, mounted into a loading device and imaged in the unloaded and loaded states using a micro-CT scanner. Strain was measured throughout the cartilage volume using the micro-CT image data and DVC analysis. The volumetric DVC-measured strain was within 5% of the known applied strain. Variation in strain distribution between the superficial, middle and deep zones was observed, consistent with the different architecture of the material in these locations. These results indicate DVC method may be suitable for calculating strain in human articular cartilage.


Assuntos
Cartilagem Articular , Osteoartrite , Cartilagem Articular/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Articulação do Joelho , Estresse Mecânico , Microtomografia por Raio-X
8.
Front Bioeng Biotechnol ; 9: 660013, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34222211

RESUMO

Finite element models are useful for investigating internal intervertebral disc (IVD) behaviours without using disruptive experimental techniques. Simplified geometries are commonly used to reduce computational time or because internal geometries cannot be acquired from CT scans. This study aimed to (1) investigate the effect of altered geometries both at endplates and the nucleus-anulus boundary on model response, and (2) to investigate model sensitivity to material and geometric inputs, and different modelling approaches (graduated or consistent fibre bundle angles and glued or cohesive inter-lamellar contact). Six models were developed from 9.4 T MRIs of bovine IVDs. Models had two variations of endplate geometry (a simple curved profile from the centre of the disc to the periphery, and precise geometry segmented from MRIs), and three variations of NP-AF boundary (linear, curved, and segmented). Models were subjected to axial compressive loading (to 0.86 mm at a strain rate of 0.1/s) and the effect on stiffness and strain distributions, and the sensitivity to modelling approaches was investigated. The model with the most complex geometry (segmented endplates, curved NP-AF boundary) was 3.1 times stiffer than the model with the simplest geometry (curved endplates, linear NP-AF boundary), although this difference may be exaggerated since segmenting the endplates in the complex geometry models resulted in a shorter average disc height. Peak strains were close to the endplates at locations of high curvature in the segmented endplate models which were not captured in the curved endplate models. Differences were also seen in sensitivity to material properties, graduated fibre angles, cohesive rather than glued inter-lamellar contact, and NP:AF ratios. These results show that FE modellers must take care to ensure geometries are realistic so that load is distributed and passes through IVDs accurately.

9.
SICOT J ; 7: 32, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34009116

RESUMO

INTRODUCTION: Correct positioning of the glenoid component is an important determinant of outcome in shoulder arthroplasty. We describe and assess a new radiological plane of reference for improving the accuracy of glenoid preparation prior to component implantation - the Glenoid Vault Outer Cortex (GvOC) plane. METHODS: One hundred and five CT scans of normal scapulae were obtained. Forty six females and 59 males aged between 22 and 30 years. The accuracy of the GvOC plane was then compared against the current "gold standard" - the scapular border (SB). Measurements of glenoid inclination, version, rotation, and offset were obtained using both the GvOC and SB planes. These were then compared to actual values. RESULTS: The mean difference between version obtained using the GvOC plane and the actual value was 1.8° (-2 to 5, SD 1.6) as compared to 6.7° (-2 to 17, SD 4.3) when the SB plane was used, (p < 0.001). The mean difference between estimates of inclination obtained using the GvOC plane and the actual were 1.9° (-4 to 6, SD 1.6) as compared to 11.2° (-4 to 25, SD 6.1) when the SB plane was used, (p < 0.001). CONCLUSIONS: The GvOC plane produced estimates of glenoid version and inclination closer to actual values with lower variance than when the SB plane was used. The GvOC may be a more accurate and reproducible radiological method for surgeons to use when defining glenoid anatomy prior to arthroplasty surgery.

10.
Curr Osteoporos Rep ; 19(3): 318-326, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33876386

RESUMO

PURPOSE OF REVIEW: Bone matrix exhibits great complexity in its composition, structure and mechanics. Here, we provide a review of recent research articles and appraise the evidence that bone matrix quality is clinically important and possibly targetable for fracture prevention. RECENT FINDINGS: Deformation of mineralised collagen fibrils determines bone fracture mechanics. Slipping and separation at the mineral-fibril and fibril-fibril interfaces, respectively, are the structural mechanisms for plastic deformation and microcrack nucleation. Existing technologies for assessing bone tissue in vivo cannot measure matrix structure or fracture mechanics but have shown limited use in clinical settings for identifying fragility or following treatment outcomes based on composition. Matrix is biomechanically and clinically important, but the knowledge has not translated into clinical practice. The structural mechanisms by which a load is transferred from mineralised collagen fibrils to the whole bone via microcracking have been proven too complex to measure in vivo. The mineral-fibril or fibril-fibril interfaces might be suitable targets for diagnosing fragility or delivering molecules that reduce fracture risk by strengthening the mineral bonds while maintaining flexibility in the fibrils.


Assuntos
Matriz Óssea/fisiologia , Fraturas Ósseas/prevenção & controle , Fenômenos Biomecânicos , Colágeno/fisiologia , Módulo de Elasticidade , Humanos , Estresse Mecânico
12.
Materials (Basel) ; 13(23)2020 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-33255848

RESUMO

Strains within bone play an important role in the remodelling process and the mechanisms of fracture. The ability to assess these strains in vivo can provide clinically relevant information regarding bone health, injury risk, and can also be used to optimise treatments. In vivo bone strains have been investigated using multiple experimental techniques, but none have quantified 3D strains using non-invasive techniques. Digital volume correlation based on clinical MRI (DVC-MRI) is a non-invasive technique that has the potential to achieve this. However, before it can be implemented, uncertainties associated with the measurements must be quantified. Here, DVC-MRI was evaluated to assess its potential to measure in vivo strains in the talus. A zero-strain test (two repeated unloaded scans) was conducted using three MRI sequences, and three DVC approaches to quantify errors and to establish optimal settings. With optimal settings, strains could be measured with a precision of 200 µÎµ and accuracy of 480 µÎµ for a spatial resolution of 7.5 mm, and a precision of 133 µÎµ and accuracy of 251 µÎµ for a spatial resolution of 10 mm. These results demonstrate that this technique has the potential to measure relevant levels of in vivo bone strain and to be used for a range of clinical applications.

13.
Materials (Basel) ; 13(17)2020 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-32899192

RESUMO

Regenerative medicine solutions require thoughtful design to elicit the intended biological response. This includes the biomechanical stimulus to generate an appropriate strain in the scaffold and surrounding tissue to drive cell lineage to the desired tissue. To provide appropriate strain on a local level, new generations of scaffolds often involve anisotropic spatially graded mechanical properties that cannot be characterised with traditional materials testing equipment. Volumetric examination is possible with three-dimensional (3D) imaging, in situ loading and digital volume correlation (DVC). Micro-CT and DVC were utilised in this study on two sizes of 3D-printed inorganic/organic hybrid scaffolds (n = 2 and n = 4) with a repeating homogenous structure intended for cartilage regeneration. Deformation was observed with a spatial resolution of under 200 µm whilst maintaining displacement random errors of 0.97 µm, strain systematic errors of 0.17% and strain random errors of 0.031%. Digital image correlation (DIC) provided an analysis of the external surfaces whilst DVC enabled localised strain concentrations to be examined throughout the full 3D volume. Strain values derived using DVC correlated well against manually calculated ground-truth measurements (R2 = 0.98, n = 8). The technique ensures the full 3D micro-mechanical environment experienced by cells is intimately considered, enabling future studies to further examine scaffold designs for regenerative medicine.

14.
Semin Musculoskelet Radiol ; 24(3): 323-330, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32987429

RESUMO

No official data exist on the status of musculoskeletal (MSK) radiology in Europe. The Committee for National Societies conducted an international survey to understand the status of training, subspecialization, and local practice among the European Society of Musculoskeletal Radiology (ESSR) partner societies. This article reports the results of that survey. An online questionnaire was distributed to all 26 European national associations that act as official partner societies of the ESSR. The 24 questions were subdivided into six sections: society structure, relationship with the national radiological society, subspecialization, present radiology practice, MSK interventional procedures, and MSK ultrasound. The findings of our study show a lack of standardized training and/or accreditation methods in the field of MSK radiology at a national level. The European diploma in musculoskeletal radiology is directed to partly overcome this problem; however, this certification is still underrecognized. Using certification methods, a more homogeneous European landscape could be created in the future with a view to subspecialist training. MSK ultrasound and MSK interventional procedures should be performed by a health professional with a solid knowledge of the relevant imaging modalities and sufficient training in MSK radiology. Recognition of MSK radiology as an official subspecialty would make the field more attractive for younger colleagues as well as attracting the brightest and best, an important key to further development of both clinical and academic radiology. KEY POINTS: · Standardized training and/or accreditation methods in the field of MSK radiology is lacking at a national level.. · With certification methods, such as the European diploma in musculoskeletal radiology, a more homogeneous European landscape could be created in the future with a view to subspecialist training.. · Recognition of MSK radiology as an official subspecialty would make the field more attractive for younger colleagues as well as attracting the brightest and best, an important key to further development of both clinical and academic radiology..


Assuntos
Diagnóstico por Imagem/tendências , Doenças Musculoesqueléticas/diagnóstico por imagem , Europa (Continente) , Humanos , Sociedades Médicas
15.
Materials (Basel) ; 13(18)2020 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-32899671

RESUMO

Osteochondral injuries are increasingly prevalent, yet success in articular cartilage regeneration remains elusive, necessitating the development of new surgical interventions and novel medical devices. As part of device development, animal models are an important milestone in illustrating functionality of novel implants. Inspection of the tissue-biomaterial system is vital to understand and predict load-sharing capacity, fixation mechanics and micromotion, none of which are directly captured by traditional post-mortem techniques. This study aims to characterize the localised mechanics of an ex vivo ovine osteochondral tissue-biomaterial system extracted following six weeks in vivo testing, utilising laboratory micro-computed tomography, in situ loading and digital volume correlation. Herein, the full-field displacement and strain distributions were visualised across the interface of the system components, including newly formed tissue. The results from this exploratory study suggest that implant micromotion in respect to the surrounding tissue could be visualised in 3D across multiple loading steps. The methodology provides a non-destructive means to assess device performance holistically, informing device design to improve osteochondral regeneration strategies.

16.
Sci Rep ; 10(1): 14208, 2020 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-32848149

RESUMO

Nanoscale mineralized collagen fibrils may be important determinants of whole-bone mechanical properties and contribute to the risk of age-related fractures. In a cross-sectional study nano- and tissue-level mechanics were compared across trabecular sections from the proximal femora of three groups (n = 10 each): ageing non-fractured donors (Controls); untreated fracture patients (Fx-Untreated); bisphosphonate-treated fracture patients (Fx-BisTreated). Collagen fibril, mineral and tissue mechanics were measured using synchrotron X-Ray diffraction of bone sections under load. Mechanical data were compared across groups, and tissue-level data were regressed against nano. Compared to controls fracture patients exhibited significantly lower critical tissue strain, max strain and normalized strength, with lower peak fibril and mineral strain. Bisphosphonate-treated exhibited the lowest properties. In all three groups, peak mineral strain coincided with maximum tissue strength (i.e. ultimate stress), whilst peak fibril strain occurred afterwards (i.e. higher tissue strain). Tissue strain and strength were positively and strongly correlated with peak fibril and mineral strains. Age-related fractures were associated with lower peak fibril and mineral strain irrespective of treatment. Indicating earlier mineral disengagement and the subsequent onset of fibril sliding is one of the key mechanisms leading to fracture. Treatments for fragility should target collagen-mineral interactions to restore nano-scale strain to that of healthy bone.


Assuntos
Envelhecimento/fisiologia , Osso e Ossos/fisiologia , Colágenos Fibrilares/fisiologia , Fraturas do Quadril/etiologia , Osteoporose/complicações , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Estudos Transversais , Feminino , Humanos , Masculino , Nanoestruturas , Osteoporose/fisiopatologia
17.
J Mech Behav Biomed Mater ; 109: 103838, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32543404

RESUMO

The fracture resistance of load-bearing trabecular bone is adversely affected by diseases such as osteoporosis. However, there are few published measurements of trabecular bone fracture toughness due to the difficulty of conducting reliable tests in small specimens of this highly porous material. A new approach is demonstrated that uses digital volume correlation of X-ray computed tomographs to measure 3D displacement fields in which the crack shape and size can be objectively identified using a phase congruency analysis. The criteria for crack propagation, i.e. fracture toughness, can then be derived by finite element simulation, with knowledge of the elastic properties.


Assuntos
Fraturas Ósseas , Osteoporose , Osso Esponjoso/diagnóstico por imagem , Análise de Elementos Finitos , Fraturas Ósseas/diagnóstico por imagem , Humanos , Tomografia Computadorizada por Raios X
18.
J Orthop Res ; 38(7): 1566-1574, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32374418

RESUMO

Aseptic loosening of the glenoid component is one of the main reasons for the high revision rates of reverse total shoulder arthroplasty (RTSA). It has been reported that the bulky implant designs may lead to stress shielding. However, it is uncertain whether the shielding effect is severe enough to lead to bone resorption and glenoid loosening. The purpose of this study was to evaluate the level of stress-shielding and assess whether bone resorption plays a role in aseptic glenoid loosening following RTSA. A cadaveric in vitro test model was used to validate a finite element model (FEM) of the scapula. The FEM of the scapula, incorporating adaptive bone remodeling algorithms, was used to predict changes in postoperative bone density after RTSA. Changes in bone strength after implantation were also analyzed. The strain values predicted from the FEM of the scapula were in agreement with the in vitro measurements. Analysis of postoperative bone adaptation revealed that strain-induced bone resorption began at the peg of the implant and around the resected bone surface and then gradually expended to the peripheral regions. The bone strength also reduced postoperatively and appeared particularly around the implant peg. Strain-induced bone resorption is a likely source of the bone loss commonly observed in RTSA. The finite element glenoid bone remodeling simulation may be used as a tool to evaluate glenoid implant design.


Assuntos
Artroplastia do Ombro , Reabsorção Óssea , Falha de Prótese/etiologia , Escápula/fisiologia , Idoso , Feminino , Análise de Elementos Finitos , Humanos , Masculino
19.
J Shoulder Elbow Surg ; 29(10): 1981-1991, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32414612

RESUMO

BACKGROUND: The high incidence of scapular notching in reverse total shoulder arthroplasty (RTSA) has spurred several methods to minimize bone loss. However, up to 93% of RTSAs accompanying scapular notching have been reported to maintain good implant stability for over 10 years. This study was conducted to investigate the relationship between scapular notching and glenoid fixation in RTSA. METHODS: Cadaveric testing was performed to measure the notch-induced variations in strain on the scapular surface and micromotion at the bone-prosthesis interface during arm abductions of 30°, 60°, and 90°. Finite element analysis was used to further study the bone and screw stresses as well as the bone-prosthesis micromotion in cases with a grade 4 notch during complicated arm motions. RESULTS: The notch resulted in an apparent increase in inferior screw stress in the root of the screw cap and at the notch-screw conjunction. However, the maximum stress (172 MPa) along the screw after notching is still much less than the fatigue strength of the titanium screw (600 MPa) under cyclic loading. The bone-prosthesis micromotion results did not present significant notch-induced variations. CONCLUSIONS: Scapular notching will lead to few impacts on the stability of an RTSA on the glenoid side. This finding may explain the long-term longevity of RTSA in cases of severe scapular notching. The relationship between scapular notching and weak regions along the inferior screw may explain why fractures of the inferior screw are sometimes reported in patients with RTSA clinically.


Assuntos
Artroplastia do Ombro , Parafusos Ósseos , Escápula/patologia , Idoso , Artroplastia do Ombro/métodos , Fenômenos Biomecânicos , Cadáver , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Falha de Prótese , Escápula/cirurgia , Articulação do Ombro/cirurgia , Prótese de Ombro , Estresse Mecânico
20.
J Shoulder Elbow Surg ; 29(5): 1019-1029, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31948834

RESUMO

BACKGROUND: Hemiarthroplasty has clear advantages over alternative procedures and is used in 20% of all shoulder joint replacements. Because of cartilage wear, the clinical outcome of hemiarthroplasty is unreliable and controversial. This paper suggests that the optimal choice of prosthetic material may reduce cartilage degeneration and improve the reliability of the procedure. The specific objectives were to assess 3 materials and assess how the severity of arthritis might affect the choice of prosthetic material. METHODS: A CoCr alloy, an AL2O3 ceramic, and a polycarbonate urethane polymer (PCU) were mechanically tested against 5 levels of human osteoarthritic cartilage (from intact to severely arthritic, n = 45). A high friction coefficient, a decrease in Young's modulus, an increase in permeability, a decrease in relaxation time, an increase in surface roughness, and a disrupted appearance of the cartilage after testing were used as measures of cartilage damage. The biomaterial that caused minimal cartilage damage was defined as superior. RESULTS: The CoCr caused the most damage. This was followed by the AL2O3 ceramic, whereas the PCU caused the least amount of damage. Although the degree of arthritis had an effect on the results, it did not change the trend that CoCr performed worst and PCU the best. DISCUSSION AND CONCLUSION: This study indicates that ceramic implants may be a better choice than metals, and the articulating surface should be as smooth as possible. Although our results indicate that the degree of arthritis should not affect the choice of prosthetic material, this suggestion needs to be further investigated.


Assuntos
Cartilagem Articular/lesões , Hemiartroplastia/efeitos adversos , Hemiartroplastia/instrumentação , Prótese de Ombro/efeitos adversos , Materiais Biocompatíveis/efeitos adversos , Cerâmica/efeitos adversos , Ligas de Cromo/efeitos adversos , Módulo de Elasticidade , Fricção , Humanos , Teste de Materiais , Osteoartrite/diagnóstico por imagem , Poliuretanos/efeitos adversos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...