Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Open Heart ; 10(2)2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37487656

RESUMO

INTRODUCTION: Current guideline recommend functional imaging for myocardial ischaemia if coronary CT angiography (CTA) has shown coronary artery disease (CAD) of uncertain functional significance. However, diagnostic accuracy of selective myocardial perfusion imaging after coronary CTA is currently unclear. The Danish study of Non-Invasive testing in Coronary Artery Disease 3 trial is designed to evaluate head to head the diagnostic accuracy of myocardial perfusion imaging with positron emission tomography (PET) using the tracers 82Rubidium (82Rb-PET) compared with oxygen-15 labelled water PET (15O-water-PET) in patients with symptoms of obstructive CAD and a coronary CT scan with suspected obstructive CAD. METHODS AND ANALYSIS: This prospective, multicentre, cross-sectional study will include approximately 1000 symptomatic patients without previous CAD. Patients are included after referral to coronary CTA. All patients undergo a structured interview and blood is sampled for genetic and proteomic analysis and a coronary CTA. Patients with possible obstructive CAD at coronary CTA are examined with both 82Rb-PET, 15O-water-PET and invasive coronary angiography with three-vessel fractional flow reserve and thermodilution measurements of coronary flow reserve. After enrolment, patients are followed with Seattle Angina Questionnaires and follow-up PET scans in patients with an initially abnormal PET scan and for cardiovascular events in 10 years. ETHICS AND DISSEMINATION: Ethical approval was obtained from Danish regional committee on health research ethics. Written informed consent will be provided by all study participants. Results of this study will be disseminated via articles in international peer-reviewed journal. TRIAL REGISTRATION NUMBER: NCT04707859.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos Transversais , Dinamarca , Estudos Prospectivos , Proteômica , Água , Estudos Multicêntricos como Assunto
2.
Int J Cardiovasc Imaging ; 38(3): 695-705, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34655348

RESUMO

Hypo-attenuated leaflet thickening (HALT) of transcatheter aortic valves is detected on multidetector computed tomography (MDCT) and reflects leaflet thrombosis. Whether HALT affects left ventricular (LV) reverse remodeling, a favorable effect of LV afterload reduction after transcatheter aortic valve implantation (TAVI) is unknown. The aim of this study was to examine the association of HALT after TAVI with LV reverse remodeling. In this multicenter case-control study, patients with HALT on MDCT were identified, and patients without HALT were propensity matched for valve type and size, LV ejection fraction (LVEF), sex, age and time of scan. LV dimensions and function were assessed by transthoracic echocardiography before and 12 months after TAVI. Clinical outcomes (stroke or transient ischemic attack, heart failure hospitalization, new-onset atrial fibrillation, all-cause mortality) were recorded. 106 patients (age 81 ± 7 years, 55% male) with MDCT performed 37 days [IQR 32-52] after TAVI were analyzed (53 patients with HALT and 53 matched controls). Before TAVI, all echocardiographic parameters were similar between the groups. At 12 months follow-up, patients with and without HALT showed a significant reduction in LV end-diastolic volume, LV end-systolic volume and LV mass index (from 125 ± 37 to 105 ± 46 g/m2, p = 0.001 and from 127 ± 35 to 101 ± 27 g/m2, p < 0.001, respectively, p for interaction = 0.48). Moreover, LVEF improved significantly in both groups. In addition, clinical outcomes were not statistically different. Improvement in LVEF and LV reverse remodeling at 12 months after TAVI were not limited by HALT.


Assuntos
Estenose da Valva Aórtica , Trombose , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Masculino , Valor Preditivo dos Testes , Trombose/complicações , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
3.
EuroIntervention ; 17(13): 1061-1069, 2022 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-34338638

RESUMO

BACKGROUND: There are limited data on the association of membranous septum (MS) morphology and transcatheter heart valve (THV) implantation depth, and the development of new conduction abnormalities (CA) after transcatheter aortic valve implantation (TAVI). AIMS: The aim of this study was to describe the morphology of the MS and predict the risk of new CA after TAVI based on the MS morphology and THV implantation depth. METHODS: Based on preprocedural CT scans, the MS depth was measured for every 25% of the entire MS width in 272 TAVI patients without preprocedural bundle branch block (BBB) or pacemaker. Post-procedural CT scans for THV implantation depth assessment were available in 130 of these patients. RESULTS: The MS depth was a median of 2.5 mm (IQR 1.4-3.8) deeper at the posterior edge when compared to the anterior edge of the MS. New CA developed in 7.1% of patients in whom the THV did not cross the lower MS border at its anterior edge (3.6% with new BBB and high degree CA, respectively), in 18.8% of patients (15.6% with new BBB and 3.1% with new high-degree CA) where the THV overlapped the lower MS border by <2.5 mm and in 47.1% of patients (24.3% with new BBB and 22.9% with new high-degree CA) with THV overlap of the lower MS border by ≥2.5 mm. CONCLUSIONS: The difference of the MS depth and THV implantation depth measured at the anterior edge of the MS predicted new CA after TAVI.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/terapia , Humanos , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
EuroIntervention ; 16(1): 83-88, 2020 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-32011285

RESUMO

AIMS: The purpose of this registry was to determine the long-term outcomes in patients with asymptomatic contained annulus rupture (CR) as a rare complication of transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: The ENCORE registry is a multicentre registry (six centres across Europe) of patients with CR diagnosed on post-TAVI computed tomography angiography (CTA) or transoesophageal echocardiography (TEE). A total of 21 patients (mean age 81.9±4.1 years, 81% balloon-expandable TAVI prostheses) were diagnosed with CR (mean size of lesions was 15.3±6.9 × 8.5±3.3 × 8.5±2.3 mm). Seventeen were diagnosed among a total of 1,602 consecutive routine post-TAVI CTA (incidence 1.1%), two in TEE and two in post-TAVI CTA (each conducted due to suspicion of peri-interventional complications). During a mean follow-up of 2.3±1.7 years (cumulative 48.6 patient-years), nine patients (43%) died from non-cardiac causes. None of the patients exhibited symptoms or underwent interventional treatment related to the CR; no sudden cardiac death occurred. A follow-up CTA, performed in eleven patients 240±176 days post TAVI, revealed stable CR findings in seven, regression in one, and remission in three patients. CONCLUSIONS: The results of our international multicentre registry demonstrate favourable long-term outcomes of CR after TAVI supporting a watch-and-wait strategy in these patients.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica , Europa (Continente) , Seguimentos , Humanos , Estudos Longitudinais , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento
5.
J Cardiovasc Comput Tomogr ; 12(4): 290-297, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29519754

RESUMO

OBJECTIVES: We sought to determine the impact of aortic root calcium on the risk of significant paravalvular regurgitation (sPAR) in transcatheter aortic valve replacement (TAVR). METHODS: In 302 consecutive patients from 3 centers, aortic root calcium was quantified volumetrically on pre-TAVR multidetector computed tomography (MDCT) in three regions: 1) the aortic valve region, 2) the overall left ventricular outflow tract (LVOT) and 3) the upper LVOT. Transcathether heart valve (THV) oversizing was calculated as (THV nominal area/MDCT annular area-1) × 100. The study endpoint sPAR was a composite of post-dilatation (PD) and PAR > mild. RESULTS: sPAR occurred in 15% (46/302) of patients. Upper LVOT calcium volume was more predictive of sPAR than overall LVOT calcium volume, with an area under the receiver operating curve (AUC) (95% confidence interval [CI]) of 0.80 (0.67-0.89) vs. 0.60 (0.51-0.70); p = 0.0001. The optimal cut-off calcium volume thresholds determined from receiver operating curves were 21 mm3 and 30 mm3 for upper LVOT and overall LVOT calcium, respectively. Upper LVOT calcium ≥ 21 mm3, but not overall LVOT calcium ≥ 30 mm3, independently predicted sPAR, odds ratio (95%CI): 9.5 (4.1-22.3) vs 1.6 (0.6-2.7). Upper LVOT calcium was more predictive of sPAR in patients with THV oversizing ≥ 13% compared to patients with THV oversizing <13%, AUC (95% CI): 0.83 (0.72-0.93) vs. 0.67 (0.51-0.74); p < 0.0001. CONCLUSIONS: Upper LVOT calcium predicts more-than-mild paravalvular regurgitation following TAVR or the need for postdilatation. Upper LVOT calcium is most predictive of paravalvular regurgitation in the event of THV oversizing ≥ 13%.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/transplante , Calcinose/cirurgia , Cálcio/metabolismo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/metabolismo , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/metabolismo , Estenose da Valva Aórtica/fisiopatologia , Área Sob a Curva , Colúmbia Britânica , Calcinose/diagnóstico por imagem , Calcinose/metabolismo , Calcinose/fisiopatologia , Distribuição de Qui-Quadrado , Dinamarca , Ecocardiografia Transesofagiana , Feminino , Próteses Valvulares Cardíacas , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/metabolismo , Ventrículos do Coração/fisiopatologia , Humanos , Modelos Logísticos , Londres , Masculino , Tomografia Computadorizada Multidetectores , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Desenho de Prótese , Curva ROC , Reprodutibilidade dos Testes , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
7.
Am J Case Rep ; 18: 573-575, 2017 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-28536415

RESUMO

BACKGROUND Although transcatheter aortic valve replacement (TAVR) has become a worldwide and generally accepted treatment of patients with aortic stenosis at high surgical risk, there is a rising concern and debate about the occurrence of transcatheter heart valve (THV) thrombosis and its impact on TAVR outcome. It seems that the incidence of THV thrombosis is higher than first anticipated, but uncertainty remains regarding how to prevent and how to treat it. Hence, there is an urgent need for understanding THV thrombosis and to communicate experiences within the field. CASE REPORT We present a unique case of late occurrence of THV thrombosis that was resolved by switching from clopidogrel to rivaroxaban treatment. CONCLUSIONS As a novel observation, our case demonstrates that THV thrombosis may develop even late after TAVR, and even in such cases may be completely reversed. It also underscores that THV dysfunction should evoke prompt investigation for possible thrombus formation, preferable by multidetector computed tomography. Finally, this case report suggests NOAC as an alternative to warfarin treatment in patients with THV thrombosis.


Assuntos
Inibidores do Fator Xa/uso terapêutico , Próteses Valvulares Cardíacas/efeitos adversos , Rivaroxabana/uso terapêutico , Trombose/tratamento farmacológico , Substituição da Valva Aórtica Transcateter , Idoso , Estenose da Valva Aórtica/cirurgia , Humanos , Masculino
8.
Crit Care Med ; 45(7): e695-e702, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28403120

RESUMO

OBJECTIVES: The aim of this study was to test the hypothesis that the right ventricle is more dilated during resuscitation from cardiac arrest caused by pulmonary embolism, compared with hypoxia and primary arrhythmia. DESIGN: Twenty-four pigs were anesthetized and cardiac arrest was induced using three different methods. Pigs were resuscitated after 7 minutes of untreated cardiac arrest. Ultrasonographic images were obtained and the right ventricular diameter was measured. SETTING: University hospital animal laboratory. SUBJECTS: Female crossbred Landrace/Yorkshire/Duroc pigs (27-32 kg). INTERVENTIONS: Pigs were randomly assigned to cardiac arrest induced by pulmonary embolism, hypoxia, or primary arrhythmia. MEASUREMENTS AND MAIN RESULTS: There was no difference at baseline. During induction of cardiac arrest, the right ventricle dilated in all groups (p < 0.01 for all). The primary endpoint was right ventricle diameter at the third rhythm analysis: 32 mm (95% CI, 29-36) for pulmonary embolism which was significantly larger than both hypoxia: 23 mm (95% CI, 20-27) and primary arrhythmia: 25 mm (95% CI, 22-28)-the absolute difference was 7-9 mm. Physicians with basic training in focused cardiac ultrasonography were able to detect a difference in right ventricle diameter of approximately 10 mm with a sensitivity of 79% (95% CI, 64-94) and a specificity of 68% (95% CI, 56-80). CONCLUSIONS: The right ventricle was more dilated during resuscitation when cardiac arrest was caused by pulmonary embolism compared with hypoxia and primary arrhythmia. However, the right ventricle was dilated, irrespective of the cause of arrest, and diagnostic accuracy by physicians with basic training in focused cardiac ultrasonography was modest. These findings challenge the paradigm that right ventricular dilatation on ultrasound during cardiopulmonary resuscitation is particularly associated with pulmonary embolism.


Assuntos
Parada Cardíaca/etiologia , Parada Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Embolia Pulmonar/complicações , Embolia Pulmonar/fisiopatologia , Animais , Reanimação Cardiopulmonar/métodos , Feminino , Suínos , Ultrassonografia
9.
JACC Cardiovasc Imaging ; 10(5): 541-550, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27085447

RESUMO

OBJECTIVES: The goal of this study was to assess the real-world clinical utility of fractional flow reserve (FFR) derived from coronary computed tomography angiography (FFRCT) for decision-making in patients with stable coronary artery disease (CAD). BACKGROUND: FFRCT has shown promising results in identifying lesion-specific ischemia. The real-world feasibility and influence on the diagnostic work-up of FFRCT testing in patients suspected of having CAD are unknown. METHODS: We reviewed the complete diagnostic work-up of nonemergent patients referred for coronary computed tomography angiography over a 12-month period at Aarhus University Hospital, Denmark, including all patients with new-onset chest pain with no known CAD and with intermediate-range coronary lesions (lumen reduction, 30% to 70%) referred for FFRCT. The study evaluated the consequences on downstream diagnostic testing, the agreement between FFRCT and invasively measured FFR or instantaneous wave-free ratio (iFR), and the short-term clinical outcome after FFRCT testing. RESULTS: Among 1,248 patients referred for computed tomography angiography, 189 patients (mean age 59 years; 59% male) were referred for FFRCT, with a conclusive FFRCT result obtained in 185 (98%). FFRCT was ≤0.80 in 31% of patients and 10% of vessels. After FFRCT testing, invasive angiography was performed in 29%, with FFR measured in 19% and iFR in 1% of patients (with a tendency toward declining FFR-iFR guidance during the study period). FFRCT ≤0.80 correctly classified 73% (27 of 37) of patients and 70% (37 of 53) of vessels using FFR ≤0.80 or iFR ≤0.90 as the reference standard. In patients with FFRCT >0.80 being deferred from invasive coronary angiography, no adverse cardiac events occurred during a median follow-up period of 12 (range 6 to 18 months) months. CONCLUSIONS: FFRCT testing is feasible in real-world symptomatic patients with intermediate-range stenosis determined by coronary computed tomography angiography. Implementation of FFRCT for clinical decision-making may influence the downstream diagnostic workflow of patients. Patients with an FFRCT value >0.80 being deferred from invasive coronary angiography have a favorable short-term prognosis.


Assuntos
Tomada de Decisão Clínica , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Vasos Coronários/fisiopatologia , Dinamarca , Estudos de Viabilidade , Feminino , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico
10.
J Am Coll Cardiol ; 68(19): 2059-2069, 2016 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-27580689

RESUMO

BACKGROUND: There are limited data on the incidence, clinical implications, and predisposing factors of transcatheter heart valve (THV) thrombosis following transcatheter aortic valve replacement (TAVR). OBJECTIVES: The authors assessed the incidence, potential predictors, and clinical implications of THV thrombosis as determined by contrast-enhanced multidetector computed tomography (MDCT) after TAVR. METHODS: Among 460 consecutive patients who underwent TAVR with the Edwards Sapien XT or Sapien 3 (Edwards Lifesciences, Irvine, California) THV, 405 (88%) underwent MDCT in addition to transthoracic and transesophageal echocardiography 1 to 3 months post-TAVR. MDCT scans were evaluated for hypoattenuated leaflet thickening that indicated THV thrombosis. RESULTS: MDCT verified THV thrombosis in 28 of 405 (7%) patients. A total of 23 patients had subclinical THV thrombosis, whereas 5 (18%) patients experienced clinically overt obstructive THV thrombosis. THV thrombosis risk did not differ among different generations of THVs (8% vs. 6%; p = 0.42). The risk of THV thrombosis in patients who did not receive warfarin was higher compared with patients who received warfarin (10.7% vs. 1.8%; risk ratio [RR]: 6.09; 95% confidence interval [CI]: 1.86 to 19.84). A larger THV was associated with an increased risk of THV thrombosis (p = 0.03). In multivariable analysis, a 29-mm THV (RR: 2.89; 95% CI: 1.44 to 5.80) and no post-TAVR warfarin treatment (RR: 5.46; 95% CI: 1.68 to 17.7) independently predicted THV thrombosis. Treatment with warfarin effectively reverted THV thrombosis and normalized THV function in 85% of patients as documented by follow-up transesophageal echocardiography and MDCT. CONCLUSIONS: Incidence of THV thrombosis in this large study was 7%. A larger THV size may predispose to THV thrombosis, whereas treatment with warfarin appears to have a protective effect. Although often subclinical, THV thrombosis may have important clinical implications.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Complicações Pós-Operatórias/epidemiologia , Trombose/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Dinamarca/epidemiologia , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Incidência , Masculino , Tomografia Computadorizada Multidetectores , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Prognóstico , Estudos Retrospectivos , Trombose/diagnóstico , Trombose/etiologia
11.
J Heart Valve Dis ; 25(6): 756-759, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-28290179

RESUMO

Non-obstructive transcatheter heart valve (THV) thrombosis as a potential mechanism after stroke after transapical transcatheter aortic valve replacement (TAVR) is demonstrated by the present case report. By performing cardiac computed tomography (CT) in addition to standard transthoracic echocardiography (TTE) follow up after TAVR, it has been shown recently that non-obstructive THV thrombosis may be more common than previously anticipated. However, the clinical implications of non-obstructive THV thrombosis remain unclear. In the present patient, post-TAVR TTE and transeophageal echocardiography demonstrated normal THV function, and showed no evidence of THV thrombosis. In contrast, cardiac CT revealed findings consistent with THV thrombosis. The patient subsequently developed acute ischemic stroke that was treated with thrombolysis. Follow up cardiac CT and echocardiography demonstrated complete THV thrombus resolution.


Assuntos
Isquemia Encefálica/etiologia , Trombose/complicações , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Estenose da Valva Aórtica/cirurgia , Isquemia Encefálica/diagnóstico por imagem , Ecocardiografia Transesofagiana , Humanos , Imageamento por Ressonância Magnética , Masculino , Tomografia Computadorizada Multidetectores , Complicações Pós-Operatórias/diagnóstico por imagem , Terapia Trombolítica , Trombose/diagnóstico por imagem , Trombose/tratamento farmacológico
12.
JACC Cardiovasc Interv ; 8(13): 1727-32, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26476612

RESUMO

OBJECTIVES: The aim of this study was to evaluate a strategy of intentional underexpansion of excessively oversized balloon-expandable transcatheter heart valves (THVs) in terms of clinical outcomes, valve function, and frame durability at 1 year. BACKGROUND: Transcatheter aortic valve replacement requires the selection of an optimally sized THV to ensure paravalvular sealing and fixation without risking annular injury. However, some patients have "borderline" annular dimensions that require choosing between a THV that may be too small or another that may be too large. METHODS: We evaluated 47 patients at risk of annular injury who underwent transcatheter aortic valve replacement (TAVR) with an oversized, but deliberately underexpanded, THV followed by post-dilation if required. Clinical evaluation, echocardiography, and cardiac computed tomography were performed pre-TAVR, post-TAVR, and at 1 year. RESULTS: Deployment of oversized THVs with modest underfilling of the deployment balloon (<10% by volume) was not associated with significant annular injury. Paravalvular regurgitation was mild or less in 95.7% of patients, with post-dilation required in 10.7%. THV hemodynamic function was excellent and remained stable at 1 year. Computed tomography documented stent frame circularity in 87.5%. Underexpansion was greatest within the intra-annular THV inflow (stent frame area 85.8% of nominal). There was no evidence of stent frame recoil, deformation, or fracture at 1 year. CONCLUSIONS: In carefully selected patients with borderline annulus dimensions and in whom excessive oversizing of a balloon-expandable SAPIEN XT valve (Edwards Lifesciences, Inc., Irvine, California) is a concern, a strategy of deliberate underexpansion, with ad hoc post-dilation, if necessary, may reduce the risk of annular injury without compromising valve performance.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica , Valvuloplastia com Balão/métodos , Cateterismo Cardíaco/métodos , Traumatismos Cardíacos/prevenção & controle , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/lesões , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/prevenção & controle , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Feminino , Traumatismos Cardíacos/diagnóstico , Traumatismos Cardíacos/etiologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Masculino , Seleção de Pacientes , Desenho de Prótese , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia
13.
JACC Cardiovasc Imaging ; 8(9): 1045-1055, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26298072

RESUMO

OBJECTIVES: The goal of this study was to examine the diagnostic performance of noninvasive fractional flow reserve (FFR) derived from coronary computed tomography angiography (CTA) (FFRCT) in relation to coronary calcification severity. BACKGROUND: FFRCT has shown promising results in identifying lesion-specific ischemia. The extent to which the severity of coronary calcification affects the diagnostic performance of FFRCT is not known. METHODS: Coronary calcification was assessed by using the Agatston score (AS) in 214 patients suspected of having coronary artery disease who underwent coronary CTA, FFRCT, and FFR (FFR examination was performed in 333 vessels). The diagnostic performance of FFRCT (≤0.80) in identifying vessel-specific ischemia (FFR ≤0.80) was investigated across AS quartiles (Q1 to Q4) and for discrimination of ischemia in patients and vessels with a low-mid AS (Q1 to Q3) versus a high AS (Q4). Coronary CTA stenosis was defined as lumen reduction >50%. RESULTS: Mean ± SD per-patient and per-vessel AS were 302 ± 468 (range 0 to 3,599) and 95 ± 172 (range 0 to 1,703), respectively. There was no statistical difference in diagnostic accuracy, sensitivity, or specificity of FFRCT across AS quartiles. Discrimination of ischemia by FFRCT was high in patients with a high AS (416 to 3,599) and a low-mid AS (0 to 415), with no difference in area under the receiver-operating characteristic curve (AUC) (0.86 [95% confidence interval (CI): 0.76 to 0.96] vs. 0.92 [95% CI: 0.88 to 0.96]) (p = 0.45). Similarly, discrimination of ischemia by FFRCT was high in vessels with a high AS (121 to 1,703) and a low-mid AS (0 to 120) (AUC: 0.91 [95% CI: 0.85 to 0.97] vs. 0.95 [95% CI: 0.91 to 0.98]; p = 0.65). Diagnostic accuracy and specificity of FFRCT were significantly higher than for stenosis assessment in each AS quartile at the per-patient (p < 0.001) and per-vessel (p < 0.05) level with similar sensitivity. In vessels with a high AS, FFRCT exhibited improved discrimination of ischemia compared with coronary CTA alone (AUC: 0.91 vs. 0.71; p = 0.004), whereas on a per-patient level, the difference did not reach statistical significance (AUC: 0.86 vs. 0.72; p = 0.09). CONCLUSIONS: FFRCT provided high and superior diagnostic performance compared with coronary CTA interpretation alone in patients and vessels with a high AS.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Tomografia Computadorizada por Raios X , Calcificação Vascular/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Calcificação Vascular/fisiopatologia
14.
J Cardiovasc Comput Tomogr ; 9(5): 382-92, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26164109

RESUMO

BACKGROUND: A detailed assessment of calcium within the aortic root may provide important additional information regarding the risk of aortic root injury during transcatheter heart valve replacement (TAVR). OBJECTIVE: We sought to delineate the effect of calcium volume and distribution on aortic root injury during TAVR. METHODS: Thirty-three patients experiencing aortic root injury during TAVR with a balloon-expandable valve were compared with a control group of 153 consecutive TAVR patients without aortic root injury (as assessed by post-TAVR multidetector CT). Using commercial software to analyze contrast-enhanced pre-TAVR CT scans, calcium volume was determined in 3 regions: (1) the overall left ventricular outflow tract (LVOT), extending 10 mm down from the aortic annulus plane; (2) the upper LVOT, extending 2 mm down from the annulus plane; and (3) the aortic valve region. RESULTS: Calcium volumes in the upper LVOT (median, 29 vs 0 mm(3); P < .0001) and overall LVOT (median, 74 vs 3 mm(3); P = .0001) were higher in patients who experienced aortic root injury compared with the control group. Calcium in the aortic valve region did not differ between groups. Upper LVOT calcium volume was more predictive of aortic root injury than overall LVOT calcium volume (area under receiver operating curve [AUC], 0.78; 95% confidence interval, 0.69-0.86 vs AUC, 0.71; 95% confidence interval, 0.62-0.82; P = .010). Upper LVOT calcium below the noncoronary cusp was significantly more predictive of aortic root injury compared to calcium underneath the right coronary cusp or the left coronary cusp (AUC, 0.81 vs 0.68 vs 0.64). Prosthesis oversizing >20% (likelihood ratio test, P = .028) and redilatation (likelihood ratio test, P = .015) improved prediction of aortic root injury by upper LVOT calcium volume. CONCLUSION: Calcification of the LVOT, especially in the upper LVOT, located below the noncoronary cusp and extending from the annular region, is predictive of aortic root injury during TAVR with a balloon-expandable valve.


Assuntos
Doenças da Aorta/complicações , Estenose da Valva Aórtica/terapia , Valva Aórtica/patologia , Calcinose/terapia , Cateterismo Cardíaco/efeitos adversos , Traumatismos Cardíacos/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cifoplastia/efeitos adversos , Calcificação Vascular/complicações , Lesões do Sistema Vascular/etiologia , Idoso , Idoso de 80 Anos ou mais , Doenças da Aorta/diagnóstico , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/lesões , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Aortografia/métodos , Calcinose/complicações , Calcinose/diagnóstico , Cateterismo Cardíaco/métodos , Estudos de Casos e Controles , Feminino , Traumatismos Cardíacos/diagnóstico , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento , Calcificação Vascular/diagnóstico , Lesões do Sistema Vascular/diagnóstico
16.
Circ Cardiovasc Interv ; 8(4)2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25873726

RESUMO

BACKGROUND: Early stent valve thrombosis after transcatheter aortic valve implantation (TAVI) is a rare complication, which is diagnosed based on the appearance of clinical symptoms of heart failure and echocardiographic findings. After TAVI, transthoracic echocardiography is performed to assess transcatheter heart valve (THV) function. However, preliminary reports indicate the potential additive clinical value of multidetector computed tomography (MDCT) for the diagnosis of THV thrombosis. We sought to determine the value of MDCT for the diagnosis of THV thrombosis and the frequency of this complication after balloon-expandable TAVI. METHODS AND RESULTS: MDCT was performed in 140 patients within 1 to 3 months after TAVI with the Edwards Sapien XT THV to assess the presence of THV thrombosis and THV stent geometry. Post-TAVI MDCT identified THV thrombosis in 5 patients (4%). Of note, 4 of these patients were asymptomatic and had a normal transthoracic echocardiographic examination without signs of thrombus formation or flow obstruction. In patients with THV thrombosis, a left ventricular ejection fraction of <35% was present in 3 (60%), whereas 2 (40%) did not receive standard post-TAVI dual-antiplatelet therapy. Neither THV underexpansion nor THV noncircularity was detected in patients with THV thrombosis. CONCLUSIONS: Post-TAVI MDCT is a valuable tool for the diagnosis of THV thrombosis, and this complication seems to be more common than previously anticipated. Larger studies are required to identify specific risk factors of THV thrombosis.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Valva Aórtica/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Complicações Pós-Operatórias/diagnóstico , Trombose/diagnóstico , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos de Coortes , Ecocardiografia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Prognóstico , Stents/estatística & dados numéricos , Trombose/etiologia
17.
JACC Cardiovasc Interv ; 8(3): 462-471, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25790764

RESUMO

OBJECTIVES: This study sought to compare the influence of the extent of multidetector computed tomography (MDCT) area oversizing on the incidence of paravalvular aortic regurgitation (PAR) between the Sapien 3 and the Sapien XT transcatheter heart valve (THV) to define a new MDCT sizing guideline suitable for the Sapien 3 platform. BACKGROUND: The inverse relationship of PAR occurrence and oversizing has been demonstrated for the Sapien XT but the incidence of PAR with comparable oversizing with the Sapien 3 is not known. METHODS: Sixty-one prospectively enrolled patients who underwent transcatheter aortic valve replacement with the Sapien 3 THV were compared with 92 patients who underwent transcatheter aortic valve replacement with the Sapien XT THV. Patients were categorized depending on the degree of MDCT area oversizing percentage: undersizing (below 0%), 0% to 5%, 5% to 10%, and above 10%. The primary endpoint was mild or greater PAR on transthoracic echocardiography. RESULTS: Mild or greater PAR was present in 19.7% of patients (12 of 61) in the Sapien 3 group and in 54.3% of patients (50 of 92) in the Sapien XT group (p < 0.01). The Sapien 3 group, compared with the Sapien XT group, consistently demonstrated significantly lower rates of mild or greater PAR except for oversizing >10% (p for interaction = 0.54). Moderate or severe PAR rates were also lower in the Sapien 3 group than in the Sapien XT group (3.3% vs. 13.0%, p = 0.04). In the Sapien 3 group, a MDCT area oversizing percentage value of ≤4.17% was identified as the optimal cutoff value to discriminate patients with or without mild or greater PAR. CONCLUSIONS: Our retrospective analysis suggests that the Sapien 3 THV displays significantly lower rates of PAR than does the Sapien XT THV. A lesser degree of MDCT area oversizing may be employed for this new balloon-expandable THV.


Assuntos
Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Tomografia Computadorizada Multidetectores , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Canadá/epidemiologia , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Europa (Continente)/epidemiologia , Feminino , Hemodinâmica , Humanos , Incidência , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
18.
J Am Coll Cardiol ; 63(10): 976-81, 2014 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-24211502

RESUMO

OBJECTIVES: This study sought to assess the clinical outcomes and hemodynamic performance associated with a strategy of underexpanding balloon-expandable transcatheter heart valves (THV) when excessive oversizing is a concern. BACKGROUND: Transcatheter aortic valve replacement depends on the selection of an optimally sized THV. An undersized THV may lead to paravalvular regurgitation, whereas excessive oversizing may lead to annular injury. METHODS: Patients (n = 47) who underwent transcatheter aortic valve replacement with an intentionally underexpanded THV (balloon-filling volume reduced ~10%) were compared with consecutive control patients who had nominal THV balloon deployment (n = 87). Pre- and post-procedural computed tomography imaging and echocardiography were performed to assess THV stent expansion and hemodynamics. RESULTS: Underfilling resulted in THV underexpansion that was maximal at the THV inflow (85.0 ± 7.4% vs. 102.5 ± 6.2%, p < 0.001), in study versus control groups, respectively. The study group received larger THV, although annular injury was not observed. Post-dilation was required in 10.6% and 4.6% of patients of the study and control groups, respectively (p = 0.165). Echocardiographic THV area, gradient, paravalvular regurgitation, and in-hospital outcomes were similar. CONCLUSIONS: Intentionally underexpanding balloon-expandable THV by underfilling the deployment balloon did not adversely affect procedural clinical outcomes, THV gradients, or THV areas. A strategy of underexpansion, with post-dilation as necessary, might play in role in reducing the risk of annular injury and paravalvular regurgitation in selected patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Seleção de Pacientes , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Tomografia Computadorizada por Raios X , Resultado do Tratamento
19.
J Cardiovasc Comput Tomogr ; 7(4): 248-55, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24148778

RESUMO

BACKGROUND: Prosthesis-patient mismatch (PPM) is a predictor of mortality after aortic valve replacement (AVR). OBJECTIVE: We examined whether accurate 3-dimensional annular sizing with multidetector CT (MDCT) is predictive of PPM after transcatheter AVR (TAVR). METHODS: One hundred twenty-eight patients underwent MDCT then TAVR. Moderate PPM was defined as an indexed effective orifice area ≤0.85 cm²/m² and severe ≤0.65 cm²/m². MDCT annular measurements (area, short and long axis) were compared with the size of the selected transcatheter heart valve (THV) to obtain (1) the difference between prosthesis size and CT-measured mean annular diameter and (2) the percentage of undersizing or oversizing (calculated as 100 × [MDCT annular area--THV nominal area]/THV nominal area). In addition, the MDCT annular area was indexed to body surface area. These measures were evaluated as potential PPM predictors. RESULTS: We found that 42.2% of patients had moderate PPM and 9.4% had severe PPM. Procedural characteristics and in-hospital outcomes were similar between patients with or without PPM. THV undersizing of the mean aortic annulus diameter was not predictive of PPM (odds ratio [OR], 0.84; 95% CI, 0.65-1.07; P = .16; area under the receiver-operating characteristic curve [AUC], 0.58). THV undersizing of annular area was not predictive of PPM (OR, 0.96; 95% CI, 0.80-1.16; P = .69; AUC, 0.52). Indexed MDCT annular area was, however, predictive of PPM (OR, 0.24; 95% CI, 0.10-0.59; P < .001; AUC, 0.66). CONCLUSIONS: PPM is frequent after TAVR. Appropriate annular oversizing does not reduce the rate or severity of PPM. Patient annulus size mismatch, identified by indexed MDCT annular area, is a significant predictor of PPM.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Tomografia Computadorizada Multidetectores , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Colúmbia Britânica , Cateterismo Cardíaco/efeitos adversos , Distribuição de Qui-Quadrado , Dinamarca , Ecocardiografia Transesofagiana , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Imageamento Tridimensional , Modelos Logísticos , Masculino , Razão de Chances , Valor Preditivo dos Testes , Desenho de Prótese , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador , Fatores de Risco , Resultado do Tratamento
20.
Circulation ; 128(3): 244-53, 2013 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-23748467

RESUMO

BACKGROUND: Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. METHODS AND RESULTS: Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained rupture during TAVR were collected from 16 centers. A caliper-matched sample of 31 consecutive patients without annular rupture, who underwent pre-TAVR multidetector computed tomography served as a control group. Multidetector computed tomography assessment included short- and long-axis diameters and cross-sectional area of the sinotubular junction, annulus, and LVOT, and the presence, location, and extent of calcification of the LVOT, as well. There were no significant differences between the 2 groups in any preoperative clinical and echocardiographic variables. Aortic root rupture was identified in 20 patients and periaortic hematoma in 11. Patients with root rupture had a higher degree of subannular/LVOT calcification quantified by the Agatston score (181.2±211.0 versus 22.5±37.6, P<0.001), and a higher frequency of ≥20% annular area oversizing (79.4% versus 29.0%, P<0.001) and balloon postdilatation (22.6% versus 0.0%, P=0.005). In conditional logistic regression analysis for the matched data, moderate/severe LVOT/subannular calcifications (odds ratio, 10.92; 95% confidence interval, 3.23-36.91; P<0.001) and prosthesis oversizing ≥20% (odds ratio, 8.38; 95% confidence interval, 2.67-26.33; P<0.001) were associated with aortic root contained/noncontained rupture. CONCLUSIONS: This study demonstrates that LVOT calcification and aggressive annular area oversizing are associated with an increased risk of aortic root rupture during TAVR with balloon-expandable prostheses. Larger studies are warranted to confirm these findings.


Assuntos
Angioplastia com Balão/efeitos adversos , Ruptura Aórtica/etiologia , Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/epidemiologia , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Calcinose/complicações , Calcinose/diagnóstico por imagem , Calcinose/epidemiologia , Estudos de Coortes , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Modelos Logísticos , Masculino , Valor Preditivo dos Testes , Fatores de Risco , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...