Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Heart J Cardiovasc Imaging ; 23(3): 328-337, 2022 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-34751738

RESUMO

AIMS: Myocardial external efficiency (MEE) is the ratio of cardiac work in relation with energy expenditure. We studied MEE in patients with different aetiologies and stages of heart failure (HF) to discover the role and causes of deranged MEE. In addition, we explored the impact of patient characteristics such as sex, body mass index (BMI), and age on myocardial energetics. METHODS AND RESULTS: Cardiac energetic profiles were assessed with 11C-acetate positron emission tomography (PET) and left ventricular ejection fraction (LVEF) was acquired with echocardiography. MEE was studied in 121 participants: healthy controls (n = 20); HF patients with reduced (HFrEF; n = 25) and mildly reduced (HFmrEF; n = 23) LVEF; and patients with asymptomatic (AS-asymp; n = 38) and symptomatic (AS-symp; n = 15) aortic stenosis (AS). Reduced MEE coincided with symptoms of HF irrespective of aetiology and declined in tandem with deteriorating LVEF. Patients with AS-symp and HFmrEF had reduced MEE as compared with controls (22.2 ± 4.9%, P = 0.041 and 20.0 ± 4.2%, P < 0.001 vs. 26.1 ± 5.8% in controls) and a further decline was observed in patients with HFrEF (14.7 ± 6.3%, P < 0.001). Disproportionate left ventricular hypertrophy was a major cause of reduced MEE. Female sex (P < 0.001), a lower BMI (P = 0.001), and advanced age (P = 0.03) were associated with a lower MEE. CONCLUSION: MEE was reduced in patients with HFrEF, HFmrEF, and HF due to pressure overload and MEE may therefore constitute a treatment target in HF. Patients with LVH, advanced age, female sex, and low BMI had more pronounced reduction in MEE and personalized treatment within these patient subgroups could be relevant.


Assuntos
Insuficiência Cardíaca , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Humanos , Miocárdio , Prognóstico , Volume Sistólico , Função Ventricular Esquerda
2.
Cardiovasc Drugs Ther ; 35(3): 491-503, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32770520

RESUMO

PURPOSE: The glucose-lowering drug metformin has recently been shown to reduce myocardial oxygen consumption and increase myocardial efficiency in chronic heart failure (HF) patients without diabetes. However, it remains to be established whether these beneficial myocardial effects are associated with metformin-induced alterations in whole-body insulin sensitivity and substrate metabolism. METHODS: Eighteen HF patients with reduced ejection fraction and without diabetes (median age, 65 (interquartile range 55-68); ejection fraction 39 ± 6%; HbA1c 5.5 to 6.4%) were randomized to receive metformin (n = 10) or placebo (n = 8) for 3 months. We studied the effects of metformin on whole-body insulin sensitivity using a two-step hyperinsulinemic euglycemic clamp incorporating isotope-labeled tracers of glucose, palmitate, and urea. Substrate metabolism and skeletal muscle mitochondrial respiratory capacity were determined by indirect calorimetry and high-resolution respirometry, and body composition was assessed by bioelectrical impedance analysis. The primary outcome measure was change in insulin sensitivity. RESULTS: Compared with placebo, metformin treatment lowered mean glycated hemoglobin levels (absolute mean difference, - 0.2%; 95% CI - 0.3 to 0.0; p = 0.03), reduced body weight (- 2.8 kg; 95% CI - 5.0 to - 0.6; p = 0.02), and increased fasting glucagon levels (3.2 pmol L-1; 95% CI 0.4 to 6.0; p = 0.03). No changes were observed in whole-body insulin sensitivity, endogenous glucose production, and peripheral glucose disposal or oxidation with metformin. Equally, resting energy expenditure, lipid and urea turnover, and skeletal muscle mitochondrial respiratory capacity remained unaltered. CONCLUSION: Increased myocardial efficiency during metformin treatment is not mediated through improvements in insulin action in HF patients without diabetes. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov . Unique identifier: NCT02810132. Date of registration: June 22, 2016.


Assuntos
Peso Corporal/efeitos dos fármacos , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/fisiopatologia , Resistência à Insulina/fisiologia , Metformina/farmacologia , Idoso , Composição Corporal , Calorimetria Indireta , Método Duplo-Cego , Feminino , Glucagon/efeitos dos fármacos , Hemoglobinas Glicadas/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Mitocôndrias/efeitos dos fármacos , Músculo Esquelético/efeitos dos fármacos , Consumo de Oxigênio/efeitos dos fármacos , Volume Sistólico/efeitos dos fármacos
3.
Scand Cardiovasc J ; 54(5): 294-299, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32292074

RESUMO

Background. Liraglutide, a glucagon-like peptide-1 agonist, is used for treatment of type 2 diabetes and has beneficial cardiovascular properties. However, treatment increases heart rate (HR) and possibly the risk of cardiovascular events in chronic heart failure (CHF) patients. We investigated potential associations between HR changes and clinical, laboratory and echocardiographic parameters and clinical events in liraglutide treated CHF patients. Methods. This was a sub-study of the LIVE study. CHF patients (N = 241) with a left ventricular ejection fraction ≤45% were randomised to 1.8 mg liraglutide daily or placebo for 24 weeks. Electrocardiograms (N = 117) and readouts from cardiac implanted electronic devices (N = 20) were analysed for HR and arrhythmias. Results. In patients with sinus rhythm (SR), liraglutide increased HR by 8 ± 9 bpm (pulse measurements), 9 ± 9 bpm (ECG measurements) and 9 ± 6 bpm (device readouts) versus placebo (all p<.005). Increases in HR correlated with liraglutide dose (p=.01). HR remained unchanged in patients without SR. Serious cardiac adverse events were not associated with HR changes. Conclusions. During 6 months of treatment, HR increased substantially in CHF patients with SR treated with liraglutide but was not associated with adverse events. The long-term clinical significance of increased HR in liraglutide treated CHF patients needs to be determined.


Assuntos
Insuficiência Cardíaca/tratamento farmacológico , Frequência Cardíaca/efeitos dos fármacos , Incretinas/uso terapêutico , Liraglutida/uso terapêutico , Idoso , Doença Crônica , Feminino , Receptor do Peptídeo Semelhante ao Glucagon 1/agonistas , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Incretinas/efeitos adversos , Liraglutida/efeitos adversos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
4.
Eur J Heart Fail ; 22(9): 1628-1637, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-31863557

RESUMO

AIMS: The present study tested the hypothesis that metformin treatment may increase myocardial efficiency (stroke work/myocardial oxygen consumption) in insulin-resistant patients with heart failure and reduced ejection fraction (HFrEF) without diabetes. METHODS AND RESULTS: Thirty-six HFrEF patients (ejection fraction 37 ± 8%; median age 66 years) were randomised to metformin (n = 19) or placebo (n = 17) for 3 months in addition to standard heart failure therapy. The primary endpoint was change in myocardial efficiency expressed as the work metabolic index (WMI), assessed by 11 C-acetate positron emission tomography and transthoracic echocardiography. Compared with placebo, metformin treatment (1450 ± 550 mg/day) increased WMI [absolute mean difference, 1.0 mmHg·mL·m-2 ·106 ; 95% confidence interval (CI) 0.1 to 1.8; P = 0.03], equivalent to a 20% relative efficiency increase. Patients with above-median plasma metformin levels displayed greater WMI increase (25% vs. -4%; P = 0.02). Metformin reduced myocardial oxygen consumption (-1.6 mL O2 ·100 g-1 ·min-1 ; P = 0.014). Cardiac stroke work was preserved (-2 J; 95% CI -11 to 7; P = 0.69). Metformin reduced body weight (-2.2 kg; 95% CI -3.6 to -0.8; P = 0.003) and glycated haemoglobin levels (-0.2%; 95% CI -0.3 to 0.0; P = 0.02). Changes in resting and exercise ejection fraction, global longitudinal strain, and exercise capacity did not differ between groups. CONCLUSION: Metformin treatment in non-diabetic HFrEF patients improved myocardial efficiency by reducing myocardial oxygen consumption. Measurement of circulating metformin levels differentiated responders from non-responders. These energy-sparing effects of metformin encourage further large-scale investigations in heart failure patients without diabetes.


Assuntos
Diabetes Mellitus , Insuficiência Cardíaca , Metformina/uso terapêutico , Idoso , Método Duplo-Cego , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina , Volume Sistólico
5.
Sci Rep ; 9(1): 11296, 2019 08 05.
Artigo em Inglês | MEDLINE | ID: mdl-31383914

RESUMO

Myocardial deformation assessed by speckle tracking echocardiography (STE) is increasingly used for diagnosis, monitoring and prognosis in patients with clinical and pre-clinical cardiovascular diseases. Feature tracking cardiac magnetic resonance (FT-CMR) also allows myocardial deformation analysis. To clarify whether the two modalities can be used interchangeably, we compared myocardial deformation analysis by FT-CMR with STE in patients with a variety of cardiovascular diseases and healthy subjects. We included 40 patients and 10 healthy subjects undergoing cardiac magnetic resonance and echocardiographic examination for left ventricular volumetric assessment. We studied patients with heart failure and reduced ejection fraction (n = 10), acute perimyocarditis (n = 10), aortic valve stenosis (n = 10), and previous heart transplantation (n = 10) by global longitudinal (GLS), radial (GRS) and circumferential strain (GCS). Myocardial deformation analysis by FT-CMR was feasible in all but one participant. While GLS, GRS and GCS measured by FT-CMR correlated overall with STE (r = 0.74 and p < 0.001, r = 0.58 and p < 0.001, and r = 0.76 and p < 0.001), the correlations were not consistent within subgroups. GLS was systematically lower, whereas GRS and GCS were higher by FT-CMR compared to STE (p = 0.04 and p < 0.0001). Inter- and intra-observer reproducibility were comparable for FT-CMR and STE overall and across subgroups. In conclusion, myocardial deformation can be evaluated using FT-CMR applied to routine cine-CMR images in patients with a variety of cardiovascular diseases. However, correlation between FT-CMR and STE was modest and agreement was not optimal due to systematic bias regarding GLS and GCS. Consequently, FT-CMR and STE should not be used interchangeably for myocardial strain evaluation.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Coração/diagnóstico por imagem , Miocárdio/patologia , Idoso , Doenças Cardiovasculares/patologia , Ecocardiografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
6.
Circulation ; 139(18): 2129-2141, 2019 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-30884964

RESUMO

BACKGROUND: Myocardial utilization of 3-hydroxybutyrate (3-OHB) is increased in patients with heart failure and reduced ejection fraction (HFrEF). However, the cardiovascular effects of increased circulating plasma-3-OHB levels in these patients are unknown. Consequently, the authors' aim was to modulate circulating 3-OHB levels in HFrEF patients and evaluate: (1) changes in cardiac output (CO); (2) a potential dose-response relationship between 3-OHB levels and CO; (3) the impact on myocardial external energy efficiency (MEE) and oxygen consumption (MVO2); and (4) whether the cardiovascular response differed between HFrEF patients and age-matched volunteers. METHODS: Study 1: 16 chronic HFrEF patients (left ventricular ejection fraction: 37±3%) were randomized in a crossover design to 3-hour of 3-OHB or placebo infusion. Patients were monitored invasively with a Swan-Ganz catheter and with echocardiography. Study 2: In a dose-response study, 8 HFrEF patients were examined at increasing 3-OHB infusion rates. Study 3 to 4: 10 HFrEF patients and 10 age-matched volunteers were randomized in a crossover design to 3-hour 3-OHB or placebo infusion. MEE and MVO2 were evaluated using 11C-acetate positron emission tomography. RESULTS: 3-OHB infusion increased circulating levels of plasma 3-OHB from 0.4±0.3 to 3.3±0.4 mM ( P<0.001). CO rose by 2.0±0.2 L/min ( P<0.001) because of an increase in stroke volume of 20±2 mL ( P<0.001) and heart rate of 7±2 beats per minute (bpm) ( P<0.001). Left ventricular ejection fraction increased 8±1% ( P<0.001) numerically. There was a dose-response relationship with a significant CO increase of 0.3 L/min already at plasma-3-OHB levels of 0.7 mM ( P<0.001). 3-OHB increased MVO2 without altering MEE. The response to 3-OHB infusion in terms of MEE and CO did not differ between HFrEF patents and age-matched volunteers. CONCLUSIONS: 3-OHB has beneficial hemodynamic effects in HFrEF patients without impairing MEE. These beneficial effects are detectable in the physiological concentration range of circulating 3-OHB levels. The hemodynamic effects of 3-OHB were observed in both HFrEF patients and age-matched volunteers. 3-OHB may potentially constitute a novel treatment principle in HFrEF patients.


Assuntos
Ácido 3-Hidroxibutírico , Insuficiência Cardíaca , Frequência Cardíaca/efeitos dos fármacos , Tomografia por Emissão de Pósitrons , Volume Sistólico/efeitos dos fármacos , Ácido 3-Hidroxibutírico/farmacocinética , Ácido 3-Hidroxibutírico/farmacologia , Acetatos/farmacologia , Idoso , Radioisótopos de Carbono/farmacologia , Doença Crônica , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio/efeitos dos fármacos
7.
J Am Heart Assoc ; 7(21): e009974, 2018 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-30571379

RESUMO

Background This study evaluated myocardial oxygen consumption (MVO2) and myocardial external efficiency (MEE) in patients with cardiac amyloidosis (CA). Furthermore, we compared MEE and MVO2 in subjects with light chain amyloidosis versus transthyretin (ATTR) amyloidosis. Methods and Results The study population comprised 40 subjects: 25 patients with confirmed CA and 15 control subjects. All subjects underwent an 11C-acetate positron emission tomography. Furthermore, the CA patients underwent comprehensive echocardiography and right heart catheterization during a symptom-limited, semi-supine exercise test. MEE was calculated from 11C-acetate positron emission tomography as the ratio of left ventricular (LV) stroke work and the energy equivalent of MVO2. Myocardial work efficiency was calculated as echocardiography-derived work pressure product divided by three-dimensional LV mass. CA patients had significantly lower LV-ejection fraction (54±13% versus 63±4%, P<0.05) and LV-global longitudinal strain (LVGLS) (12±4% versus 19±2%, P<0.0001) and a more restrictive filling pattern (E/e'-ratio 18 [12-25] versus 8 [7-9], P<0.0001) than controls. MEE was severely reduced (13±5% versus 22±5%, P<0.0001) whereas total MVO2 was higher (18±6 mL/min versus 13±3 mL/min, P<0.01) in CA patients than controls. MEE decreased with increasing New York Heart Association symptom burden ( P<0.0001). We found a good relationship between MEE and peak exercise systolic performance (LVGLS: R2=0.60, P<0.0001; myocardial work efficiency: R2=0.48, P<0.0001; cardiac index: R2=0.52, P<0.0001) and between MEE and myocardial blood flow ( R2=0.44, P<0.0001). Conclusion Myocardial oxidative metabolism is disturbed in CA patients with increased total MVO2 and reduced MEE. MEE correlated significantly with echocardiographic derived systolic parameters such as myocardial work efficiency and LVGLS that might be used as surrogate MEE markers.


Assuntos
Amiloidose/metabolismo , Amiloidose/fisiopatologia , Cardiopatias/metabolismo , Cardiopatias/fisiopatologia , Coração/fisiopatologia , Miocárdio/metabolismo , Consumo de Oxigênio , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
J Nucl Cardiol ; 25(6): 1937-1944, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29946824

RESUMO

BACKGROUND: Myocardial external efficiency (MEE) is defined as the ratio of kinetic energy associated with cardiac work [forward cardiac output (FCO)*mean systemic pressure] and the chemical energy from oxygen consumed (MVO2) by the left ventricular mass (LVM). We developed a fully automated method for estimating MEE based on a single 11C-acetate PET scan without ECG-gating. METHODS AND RESULTS: Ten healthy controls, 34 patients with aortic valve stenosis (AVS), and 20 patients with mitral valve regurgitation (MVR) were recruited in a dual-center study. MVO2 was calculated using washout of 11C -acetate activity. FCO and LVM were calculated automatically using dynamic PET and parametric image formation. FCO and LVM were also obtained using cardiac magnetic resonance (CMR) in all subjects. The correlation between MEEPET-CMR and MEEPET was high (r = 0.85, P < 0.001) without significant bias. MEEPET was 23.6 ± 4.2% for controls and was lowered in AVS (17.2 ± 4.3%, P < 0.001) and in MVR (18.0 ± 5.2%, P = 0.004). MEEPET was strongly associated with both NYHA class (P < 0.001) and the magnitude of valvular dysfunction (mean aortic gradient: P < 0.001, regurgitant fraction: P = 0.009). CONCLUSION: A single 11C-acetate PET yields accurate and automated MEE results on different scanners. MEE might provide an unbiased measurement of the phenotypic response to valvular disease.


Assuntos
Miocárdio/metabolismo , Consumo de Oxigênio , Tomografia por Emissão de Pósitrons/métodos , Acetatos , Adulto , Idoso , Radioisótopos de Carbono , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
J Nucl Cardiol ; 25(6): 1929-1936, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29855984

RESUMO

BACKGROUND: Myocardial efficiency measured by 11C-acetate positron emission tomography (PET) has successfully been used in clinical research to quantify mechanoenergetic coupling. The objective of this study was to establish the repeatability of myocardial external efficiency (MEE) and work metabolic index (WMI) by non-invasive concepts. METHODS AND RESULTS: Ten healthy volunteers (63 ± 4 years) were examined twice, one week apart, using 11C-acetate PET, cardiovascular magnetic resonance (CMR), and echocardiography. Myocardial oxygen consumption from PET was combined with stroke work data from CMR, echocardiography, or PET to obtain MEE and WMI for each modality. Repeatability was estimated as the coefficient of variation (CV) between test and retest. MEECMR, MEEEcho, and MEEPET values were 21.9 ± 2.7%, 16.4 ± 3.7%, and 23.8 ± 4.9%, respectively, P < .001. WMICMR, WMIEcho, and WMIPET values were 4.42 ± 0.90, 4.07 ± 0.63, and 4.58 ± 1.13 mmHg × mL/m2 × 106, respectively, P = .45. Repeatability for MEECMR was superior compared with MEEEcho but did not differ significantly compared with MEEPET (6.3% vs 12.9% and 9.4%, P = .04 and .25). CV values for WMICMR, WMIEcho, and WMIPET were 10.0%, 14.8%, and 12.0%, respectively, (P = .53). CONCLUSIONS: Non-invasive measurements of MEE using 11C-acetate PET are highly repeatable. A PET-only approach did not differ significantly from CMR/PET and might facilitate further clinical research due to lower costs and broader applicability.


Assuntos
Imagem Multimodal/métodos , Miocárdio/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Acetatos , Idoso , Radioisótopos de Carbono , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Oxirredução , Consumo de Oxigênio , Reprodutibilidade dos Testes
10.
Circ Cardiovasc Imaging ; 10(10)2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28956773

RESUMO

BACKGROUND: Currently, no pharmacological treatment can modify the natural history of aortic valve stenosis (AS). This underlines the critical need to explore novel treatment strategies, which could postpone or prevent the need for aortic valve replacement in patients with asymptomatic AS. The objectives of this study were to investigate whether metoprolol reduce the hemodynamic and metabolic burden imposed by AS. METHODS AND RESULTS: In a double-blinded design, 40 patients with moderate-severe asymptomatic AS (aortic valve area, 0.5±0.1 cm2/m2; peak gradient, 53±19 mm Hg) were randomized to placebo or metoprolol treatment for 22 weeks. Patients were evaluated by echocardiography, cardiovascular magnetic resonance, and 11C-acetate positron emission tomography. Compared with placebo, metoprolol (100±53 mg/d) decreased heart rate; mean difference (95% confidence interval) -8 minute-1 (-13, -3; P=0.003) and increased ejection time 26 ms (2, 50; P=0.03). Furthermore, metoprolol reduced aortic valve peak -7 mm Hg (-13, 0; P=0.05) and mean -4 mm Hg (-7, -1; P=0.03) gradients, without affecting stroke volume 3 mL/m2 (-2, 8; P=0.16). Valvuloarterial impedance (ie, global afterload) and myocardial oxygen consumption were reduced by -11% and -12% (P=0.03 and 0.01), respectively; and decreased heart rate correlated with lower valvuloarterial impedance, myocardial oxygen consumption, and improved myocardial efficiency defined as stroke work/myocardial oxygen consumption (r=0.63-0.65; all P<0.01). There were 2 adverse cardiovascular events in the metoprolol group and none in the placebo group. CONCLUSIONS: In patients with asymptomatic AS, metoprolol increases systolic ejection time and reduces aortic valve gradients, global afterload, and myocardial oxygen requirements. Thus, metoprolol displays favorable hemodynamic and metabolic effects and could improve outcome in patients with asymptomatic AS. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02076711.


Assuntos
Antagonistas de Receptores Adrenérgicos beta 1/uso terapêutico , Estenose da Valva Aórtica/tratamento farmacológico , Valva Aórtica/efeitos dos fármacos , Metabolismo Energético/efeitos dos fármacos , Hemodinâmica/efeitos dos fármacos , Metoprolol/uso terapêutico , Antagonistas de Receptores Adrenérgicos beta 1/efeitos adversos , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/metabolismo , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/metabolismo , Estenose da Valva Aórtica/fisiopatologia , Doenças Assintomáticas , Dinamarca , Método Duplo-Cego , Ecocardiografia Doppler , Feminino , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Metoprolol/efeitos adversos , Pessoa de Meia-Idade , Consumo de Oxigênio/efeitos dos fármacos , Tomografia por Emissão de Pósitrons , Fatores de Tempo , Resultado do Tratamento
11.
J Am Heart Assoc ; 6(2)2017 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-28167498

RESUMO

BACKGROUND: Myocardial oxygen consumption (MVO2) and its coupling to contractile work are fundamentals of cardiac function and may be involved causally in the transition from compensated left ventricular hypertrophy to failure. Nevertheless, these processes have not been studied previously in patients with aortic valve stenosis (AS). METHODS AND RESULTS: Participants underwent 11C-acetate positron emission tomography, cardiovascular magnetic resonance, and echocardiography to measure MVO2 and myocardial external efficiency (MEE) defined as the ratio of left ventricular stroke work and the energy equivalent of MVO2. We studied 10 healthy controls (group A), 37 asymptomatic AS patients with left ventricular ejection fraction ≥50% (group B), 12 symptomatic AS patients with left ventricular ejection fraction ≥50% (group C), and 9 symptomatic AS patients with left ventricular ejection fraction <50% (group D). MVO2 did not differ among groups A, B, C, and D (0.105±0.02, 0.117±0.024, 0.129±0.032, and 0.104±0.026 mL/min per gram, respectively; P=0.07), whereas MEE was reduced in group D (21.0±1.6%, 22.3±3.3%, 22.1±4.2%, and 17.3±4.7%, respectively; P<0.05). Similarly, patients with global longitudinal strain greater than -12% and paradoxical low-flow, low-gradient AS had impaired MEE (P<0.05 versus controls). The ability to discriminate between symptomatic and asymptomatic patients was superior for global longitudinal strain compared with MVO2 and MEE (area under the curve 0.98, 0.48, and 0.61, respectively; P<0.05). CONCLUSIONS: AS patients display a persistent ability to maintain normal MVO2 and MEE (ie, the ability to convert energy into stroke work); however, patients with left ventricular ejection fraction <50%; global longitudinal strain greater than -12%; or paradoxical low-flow, low-gradient AS demonstrate reduced MEE. These findings suggest that mitochondrial uncoupling contributes to the dismal prognosis in patients with reduced contractile function or paradoxical low-flow, low-gradient AS.


Assuntos
Estenose da Valva Aórtica/metabolismo , Insuficiência Cardíaca/metabolismo , Ventrículos do Coração/fisiopatologia , Miocárdio/metabolismo , Consumo de Oxigênio , Volume Sistólico/fisiologia , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Progressão da Doença , Ecocardiografia , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Prognóstico , Índice de Gravidade de Doença , Função Ventricular Esquerda
13.
J Nucl Med ; 57(9): 1382-7, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27127219

RESUMO

UNLABELLED: Dynamic cardiac PET is used to quantify molecular processes in vivo. However, measurements of left ventricular (LV) mass and volume require electrocardiogram-gated PET data. The aim of this study was to explore the feasibility of measuring LV geometry using nongated dynamic cardiac PET. METHODS: Thirty-five patients with aortic-valve stenosis and 10 healthy controls underwent a 27-min (11)C-acetate PET/CT scan and cardiac MRI (CMR). The controls were scanned twice to assess repeatability. Parametric images of uptake rate K1 and the blood pool were generated from nongated dynamic data. Using software-based structure recognition, the LV wall was automatically segmented from K1 images to derive functional assessments of LV mass (mLV) and wall thickness. End-systolic and end-diastolic volumes were calculated using blood pool images and applied to obtain stroke volume and LV ejection fraction (LVEF). PET measurements were compared with CMR. RESULTS: High, linear correlations were found for LV mass (r = 0.95), end-systolic volume (r = 0.93), and end-diastolic volume (r = 0.90), and slightly lower correlations were found for stroke volume (r = 0.74), LVEF (r = 0.81), and thickness (r = 0.78). Bland-Altman analyses showed significant differences for mLV and thickness only and an overestimation for LVEF at lower values. Intra- and interobserver correlations were greater than 0.95 for all PET measurements. PET repeatability accuracy in the controls was comparable to CMR. CONCLUSION: LV mass and volume are accurately and automatically generated from dynamic (11)C-acetate PET without electrocardiogram gating. This method can be incorporated in a standard routine without any additional workload and can, in theory, be extended to other PET tracers.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Reconhecimento Automatizado de Padrão/métodos , Tomografia por Emissão de Pósitrons/métodos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Estenose da Valva Aórtica/complicações , Técnicas de Imagem de Sincronização Cardíaca , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Tamanho do Órgão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/etiologia
14.
J Nucl Cardiol ; 23(4): 670-9, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27094041

RESUMO

BACKGROUND: Noninvasive estimation of myocardial external efficiency (MEE) requires measurements of left ventricular (LV) oxygen consumption with [(11)C]acetate PET in addition to LV stroke volume and mass with cardiovascular magnetic resonance (CMR). Measuring LV geometry directly from ECG-gated [(11)C]acetate PET might enable MEE evaluation from a single PET scan. Therefore, we sought to establish the accuracy of measuring LV volumes, mass, and MEE directly from ECG-gated [(11)C]acetate PET. METHODS: Thirty-five subjects with aortic valve stenosis underwent ECG-gated [(11)C]acetate PET and CMR. List mode PET data were rebinned into 16-bin ECG-gated uptake images before measuring LV volumes and mass using commercial software and compared to CMR. Dynamic datasets were used for calculation of mean LV oxygen consumption and MEE. RESULTS: LV mass, volumes, and ejection fraction measured by CMR and PET correlated strongly (r = 0.86-0.92, P < .001 for all), but were underestimated by PET (P < .001 for all except ESV P = .79). PET-based MEE, corrected for bias, correlated fairly with PET/CMR-based MEE (r = 0.60, P < .001, bias -3 ± 21%, P = .56). PET-based MEE bias was strongly associated with LV wall thickness. CONCLUSIONS: Although analysis-related improvements in accuracy are recommended, LV geometry estimated from ECG-gated [(11)C]acetate PET correlate excellently with CMR and can indeed be used to evaluate MEE.


Assuntos
Acetatos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Consumo de Oxigênio , Tomografia por Emissão de Pósitrons/métodos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Radioisótopos de Carbono , Técnicas de Imagem Cardíaca/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
EJNMMI Phys ; 2(1): 25, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26501826

RESUMO

BACKGROUND: The aim of this study was to develop and validate an automated method for extracting forward stroke volume (FSV) using indicator dilution theory directly from dynamic positron emission tomography (PET) studies for two different tracers and scanners. METHODS: 35 subjects underwent a dynamic (11)C-acetate PET scan on a Siemens Biograph TruePoint-64 PET/CT (scanner I). In addition, 10 subjects underwent both dynamic (15)O-water PET and (11)C-acetate PET scans on a GE Discovery-ST PET/CT (scanner II). The left ventricular (LV)-aortic time-activity curve (TAC) was extracted automatically from PET data using cluster analysis. The first-pass peak was isolated by automatic extrapolation of the downslope of the TAC. FSV was calculated as the injected dose divided by the product of heart rate and the area under the curve of the first-pass peak. Gold standard FSV was measured using phase-contrast cardiovascular magnetic resonance (CMR). RESULTS: FSVPET correlated highly with FSVCMR (r = 0.87, slope = 0.90 for scanner I, r = 0.87, slope = 1.65, and r = 0.85, slope = 1.69 for scanner II for (15)O-water and (11)C-acetate, respectively) although a systematic bias was observed for both scanners (p < 0.001 for all). FSV based on (11)C-acetate and (15)O-water correlated highly (r = 0.99, slope = 1.03) with no significant difference between FSV estimates (p = 0.14). CONCLUSIONS: FSV can be obtained automatically using dynamic PET/CT and cluster analysis. Results are almost identical for (11)C-acetate and (15)O-water. A scanner-dependent bias was observed, and a scanner calibration factor is required for multi-scanner studies. Generalization of the method to other tracers and scanners requires further validation.

16.
BMJ Case Rep ; 20152015 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-26438683

RESUMO

A 64-year-old previously healthy woman consulted her general practitioner because of recurrent episodes of right-sided monocular transient visual loss (ie, amaurosis fugax). At first, these symptoms were followed over time, but as the attacks worsened, and were accompanied by dizziness and general discomfort, the patient was admitted to the department of neurology for further investigations. CT of the brain was normal; however, during admission, the patient developed rapid atrial fibrillation and was transferred to the department of cardiology. Transthoracic echocardiography revealed a massive tumour on the atrial side of the anterior mitral valve leaflet, partly obstructing the mitral valve inflow. The tumour was excised and a biological prosthetic mitral valve inserted. The tumour was histologically determined to be a highly malignant dedifferentiated chondrosarcoma. After 6 months, the tumour relapsed and expanded aggressively to completely obstruct the mitral valve inflow, ultimately leading to cardiac arrest and death.


Assuntos
Amaurose Fugaz/etiologia , Condrossarcoma/patologia , Condrossarcoma/cirurgia , Neoplasias Cardíacas/diagnóstico , Neoplasias Cardíacas/cirurgia , Fibrilação Atrial/etiologia , Ecocardiografia , Evolução Fatal , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia Computadorizada por Raios X
17.
Case Rep Med ; 2013: 712383, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23573098

RESUMO

A previously healthy 29-year-old man was admitted with palpitations, dizziness, and near-syncope after he had recently started taking weight loss pills purchased on the internet. The pills contained caffeine and ephedrine. An electrocardiogram and telemetry revealed multiple episodes of non-sustained monomorphic ventricular tachycardia, which was successfully treated with amiodarone. In conclusion, unauthorized weight loss pills can be harmful. In particular, ephedrine-containing drugs carry a risk of ventricular tachycardia and should be discouraged.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...