Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Cardiovasc Electrophysiol ; 25(8): 882-888, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24724625

RESUMO

BACKGROUND: The left ventricular (LV) lead local electrogram (EGM) delay from the beginning of the QRS complex (QLV) is considered a strong predictor of response to cardiac resynchronization therapy. We have developed a method for fast epicardial QLV mapping during video-thoracoscopic surgery to guide LV lead placement. METHODS: A three-port, video-thoracoscopic approach was used for LV free wall epicardial mapping and lead implantation. A decapolar electrophysiological catheter was introduced through one port and systematically attached to multiple accessible LV sites. The pacing lead was targeted to the site with maximum QLV. The LV free wall activation pattern was analyzed in 16 pre-specified anatomical segments. RESULTS: We implanted LV leads in 13 patients with LBBB or IVCD. The procedural and mapping times were 142 ± 39 minutes and 20 ± 9 minutes, respectively. A total of 15.0 ± 2.2 LV segments were mappable with variable spatial distribution of QLV-optimum. The QLV ratio (QLV/QRSd) at the optimum segment was significantly higher (by 0.17 ± 0.08, p < 0.00001) as compared to an empirical midventricular lateral segment. The LV lead was implanted at the optimum segment in 11 patients (at an adjacent segment in 2 patients) achieving a QLV ratio of 0.82 ± 0.09 (range 0.63-0.93) and 99.5 ± 0.6% match with intraprocedural mapping. CONCLUSION: Video-thoracoscopic LV lead implantation can be effectively and safely guided by epicardial QLV mapping. This strategy was highly successful in targeting the selected LV segment and resulted in significantly higher QLV ratios compared to an empirical midventricular lateral segment.


Assuntos
Bloqueio de Ramo/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Mapeamento Epicárdico , Ventrículos do Coração/cirurgia , Pericárdio/fisiopatologia , Cirurgia Torácica Vídeoassistida , Idoso , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Tempo , Função Ventricular Esquerda , Pressão Ventricular
2.
BMC Cardiovasc Disord ; 12: 34, 2012 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-22607487

RESUMO

BACKGROUND: Considerable proportion of patients does not respond to the cardiac resynchronization therapy (CRT). This study investigated clinical relevance of left ventricular electrode local electrogram delay from the beginning of QRS (QLV). We hypothesized that longer QLV indicating more optimal lead placement in the late activated regions is associated with the higher probability of positive CRT response. METHODS: We conducted a retrospective, single-centre analysis of 161 consecutive patients with heart failure and LBBB or nonspecific intraventricular conduction delay (IVCD) treated with CRT. We routinely intend to implant the LV lead in a region with long QLV. Clinical response to CRT, left ventricular (LV) reverse remodelling (i.e. decrease in LV end-systolic diameter - LVESD ≥10%) and reduction in plasma level of NT-proBNP >30% at 12-month post-implant were the study endpoints. We analyzed association between pre-implant variables and the study endpoints. RESULTS: Clinical CRT response rate reached 58%, 84% and 92% in the lowest (≤105 ms), middle (106-130 ms) and the highest (>130 ms) QLV tertile (p < 0.0001), respectively. Longer QRS duration (p = 0.002), smaller LVESD and a non-ischemic cardiomyopathy (both p = 0.02) were also univariately associated with positive clinical CRT response. In a multivariate analysis, QLV remained the strongest predictor of clinical CRT response (p < 0.00001), followed by LVESD (p = 0.01) and etiology of LV dysfunction (p = 0.04). Comparable predictive power of QLV for LV reverse remodelling and NT-proBNP response rates was observed. CONCLUSION: LV lead position assessed by duration of the QLV interval was found the strongest independent predictor of beneficial clinical response to CRT.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Técnicas Eletrofisiológicas Cardíacas , Bloqueio Cardíaco/terapia , Insuficiência Cardíaca/terapia , Função Ventricular Esquerda , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Distribuição de Qui-Quadrado , República Tcheca , Desenho de Equipamento , Feminino , Bloqueio Cardíaco/sangue , Bloqueio Cardíaco/fisiopatologia , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/fisiopatologia , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Remodelação Ventricular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...