1.
Bone ; 164: 116513, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35944891

RESUMO

Men with distal forearm fractures have reduced bone density, an increased risk of osteoporosis and of further fractures. The aim of the study was to investigate the structural determinants of these observations using quantitative CT (qCT). Ninety six men with low-trauma distal forearm fracture and 101 age-matched healthy control subjects were recruited. All subjects underwent a quantitative CT on a standard 64-slice whole body CT scanner. These were analysed on Mindways QCT PRO™ Software to generate volumetric and geometric data at the lumbar spine, femoral neck and total hip, ultra-distal and distal 33 % radius. Biochemical investigations, health questionnaires and measurements of bone turnover were made. Men with fracture had significantly lower total and trabecular vBMD at all sites. The greatest percentage reduction was at the ultra-distal radius (13.5 % total and 11.7 % trabecular vBMD). In the fracture group cortical vBMD was significantly higher in the femoral neck (p < 0.001) and maintained at the ultra-distal radius compared with control subjects. However, cortical cross-sectional area (CSA) and thickness were significantly reduced at the femoral neck (p < 0.001 and p = 0.002 respectively) and forearm sites (CSA ultradistal radius p = 0.001, cortical thickness p = 0.002, CSA distal one third radius p = 0.045 and cortical thickness p = 0.005). Cross sectional moment of inertia (CSMI) and section moduli were significantly reduced at the femoral neck (CSMI1 p = 0.002, CSMI2 p = 0.012 and section moduli Z1 p < 0.001, Z2 p = 0.004) and the ultra-distal radius (CSMI1 p = 0.008 and section moduli Z1 p = 0.018, Z2 p = 0.007). In stepwise logistic regression analysis distal forearm fracture showed the strongest association with a model comprising ultra-distal forearm trabecular vBMD (negative), procollagen type I N-terminal propeptide (PINP, positive) and sex hormone binding globulin (SHBG, negative). In conclusion, these observations explain the structural reasons for the increased fracture risk in men with distal forearm fractures.


Assuntos
Osteólise , Fraturas por Osteoporose , Absorciometria de Fóton , Densidade Óssea , Antebraço , Humanos , Vértebras Lombares , Masculino , Rádio (Anatomia) , Globulina de Ligação a Hormônio Sexual , Tomografia Computadorizada por Raios X
2.
J Clin Densitom ; 23(3): 418-425, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31160147

RESUMO

The Mr F study investigates the pathogenesis of low trauma distal forearm fractures in men and includes volumetric bone mineral density (vBMD) measurements at the ultradistal forearm as there are no current data. A standard 64 slice CT scanner was used to determine if it was possible to adapt the existing Mindways quantitative computed tomography Pro software for measuring vBMD values at the hip and spine sites. For calculation of intra- and interobserver reliability 40 forearm scans out of the 300 available were chosen randomly. The images were analyzed using the Slice Pick module and Bone Investigational Toolkit. The 4% length of the radius was chosen by measuring the length of the radius from the scaphoid fossa distally to the radial head. The acquired image then underwent extraction, isolation, rotation, and selection of region of interest in order to generate a report on vBMD. A cross-sectional image was created to allow the generation of data on the cortical and trabecular components separately. Repeat analyses were undertaken by 3 independent observers who were blinded as to whether the image was from a participant with or without fracture. The images were presented in random order at each time point. The following parameters were recorded: cortical cross sectional area, total vBMD, trabecular vBMD, and cortical vBMD (CvBMD). Data were analyzed by calculating intraclass correlation coefficients for intra- and interobserver reliability. The lowest values occurred at the CvBMD with intraobserver reliability of 0.92 (95% confidence interval [CI] of 0.86-0.96) and interobserver reliability of 0.92 (95% CI 0.89-0.96). All other parameters had reliability values between 0.97 and 0.99 with tighter 95% CI than for CvBMD. The method of adapting the Mindways Pro software using a standard CT to produce vBMD and structural data at the ultradistal radius is reliable.


Assuntos
Densidade Óssea , Osso Esponjoso/diagnóstico por imagem , Osso Cortical/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Osteoporose/diagnóstico por imagem , Rádio (Anatomia)/diagnóstico por imagem , Software , Tomografia Computadorizada Espiral/métodos , Ulna/diagnóstico por imagem , Idoso , Traumatismos do Antebraço , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas do Rádio/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomógrafos Computadorizados , Tomografia Computadorizada Espiral/instrumentação , Fraturas da Ulna/diagnóstico por imagem
4.
J Bone Miner Res ; 34(6): 1025-1032, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30845365

RESUMO

There is a concern that bisphosphonates may impair fracture healing because of their inhibitory effects on bone turnover. Here we evaluated the effects of early bisphosphonate therapy on fracture healing and functional outcome following a fracture of the distal radius. The fracture and bisphosphonates (FAB) trial was a double-blind, randomized, placebo-controlled trial involving 15 trauma centers in the United Kingdom. We enrolled 421 bisphosphonate-naive patients aged ≥50 years with a radiographically confirmed fracture of the distal radius and randomized them in a 1:1 ratio to receive alendronic acid 70 mg once weekly (n = 215) or placebo (n = 206) within 14 days of the fracture. The primary outcome measure was the proportion of fractures that had radiologically united at 4 weeks as assessed by an observer, blinded to treatment allocation. Secondary outcomes included the Disabilities of the Arm Shoulder and Hand (DASH) questionnaire, range of wrist movement and grip strength, pain and analgesia requirements, and the rate of malunion. The mean ± SD age of participants was 63 ± 8.5 years and 362 (86%) were female. At 4 weeks, 48 of 202 (23.8%) fractures had united in the alendronic acid group compared with 52 of 187 (27.8%) in the placebo group (observed absolute proportion difference 4.0%; 95% CI, -4.7% to 12.8%; p = 0.36). The absolute proportion difference between groups based on imputed data was 4.5% (95% CI, -4.7% to 13.8%; p = 0.30). There was no significant difference in the proportion of fractures that had united at any other time point and no differences in the DASH score, pain at the fracture site, grip strength, or any other clinical outcome. We conclude that among patients aged 50 years and above with a distal radius fracture, early administration of alendronic acid does not adversely affect fracture union or clinical outcome. These findings suggest bisphosphonate therapy can be safely commenced early after fracture if clinically indicated. © 2019 American Society for Bone and Mineral Research.


Assuntos
Alendronato/farmacologia , Consolidação da Fratura/efeitos dos fármacos , Alendronato/uso terapêutico , Feminino , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/tratamento farmacológico , Humanos , Masculino , Adesão à Medicação , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Placebos , Inquéritos e Questionários , Resultado do Tratamento
5.
Shoulder Elbow ; 8(2): 77-89, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27583004

RESUMO

BACKGROUND: We explore the nature, extent and validity of research studies concerning the management of shoulder arthritis to identify whether current management recommendations are adequate. METHODS: A full electronic search for relevant studies published between 2002 and 2012 was performed. The search focused on level 1 and level 2 studies. Full texts of selected articles were retrieved and assessed for quality against validated criteria. RESULTS: Four hundred and eleven studies were identified on the initial search and screened. Sixteen studies were selected for inclusion in the review. The studies identified were unable to provide a clear indication of best intervention for shoulder arthritis. The inclusion of a range of shoulder pathologies in some studies and the diversity in outcome measures used made it difficult for systematic reviews to effectively pool data. Better outcomes have been shown with total shoulder replacement over hemiarthroplasty for shoulder osteoarthritis; however, primary studies were often of limited quality. Sparse evidence is available for all other interventions, regardless of whether operative or non-operative. CONCLUSIONS: The present review highlights the need for standardization of outcome assessment following treatment of shoulder arthritis. More rigorous and robust primary studies are needed to guide clinical practice on the best interventions for arthritis of the shoulder.

6.
J Shoulder Elbow Surg ; 25(10): 1661-7, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27068382

RESUMO

BACKGROUND: Ultrasound provides evaluation of rotator cuff disease with accuracy comparable to that of magnetic resonance imaging. Fluid in the sheath of the long head of the biceps tendon (LHB), identified on ultrasound scan, has been associated with disease of the rotator cuff, LHB, and glenohumeral joint. Prior literature has compared ultrasound findings only with arthrography, and results have been conflicting. Arthroscopy remains the reference standard in assessing accuracy of imaging modalities. We present the first study investigating the significance of fluid in the LHB on ultrasound in predicting subsequent rotator cuff disease identified on arthroscopy. METHODS: Records were reviewed of 175 patients undergoing ultrasound and subsequent arthroscopy under 1 shoulder surgeon. Experienced musculoskeletal radiologists and sonographers performed ultrasound. Ultrasound examination and operating records were collected and analyzed. Data were analyzed using descriptive statistics, correlation, and logistic regression modeling. RESULTS: Highly significant correlation (P < .001; ρ = 0.354) was found between fluid in the LHB sheath and rotator cuff tears on arthroscopy. Statistically significant but weak correlation (P < .05; rho = 0.187) was found between fluid in the LHB sheath and both biceps tendon disease and glenohumeral joint disease. Fluid around the LHB was shown to increase the likelihood of having rotator cuff tear (odds ratio, 2.641; 95% confidence interval, 1.229-5.674) and biceps tendon disease (odds ratio, 2.698; 95% confidence interval, 1.216-5.987). CONCLUSION: This is the first report identifying significant correlation between fluid in the LHB sheath identified on ultrasound and subsequent rotator cuff disease identified at arthroscopy. We recommend routine reporting of fluid in the LHB sheath as it is likely to improve the accuracy of detecting rotator cuff and biceps tendon diseases.


Assuntos
Músculo Esquelético/diagnóstico por imagem , Lesões do Manguito Rotador/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Adolescente , Adulto , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/patologia , Valor Preditivo dos Testes , Lesões do Manguito Rotador/patologia , Articulação do Ombro/patologia , Ultrassonografia , Adulto Jovem
7.
Curr Osteoporos Rep ; 11(1): 11-20, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23355097

RESUMO

Adenocarcinoma of the prostate is one of the commonest cancers in the world. Due to a combination of earlier detection and better treatments, survival has increased dramatically. Prostate cancer itself is associated with lower bone density and increased fractures. This is compounded by the use of androgen deprivation therapy, which causes dramatic falls in circulating testosterone and estrogen, resulting in rapid falls in bone density, decreased muscle mass, and increased fracture rates. Bisphosphonates have been demonstrated to prevent and reverse this bone loss, but there are no anti-fracture data. Denosumab, a monoclonal antibody to RANKL, has recently been shown to increase bone density and reduce fracture rates. Prostate cancer also commonly metastasizes to bone where it can cause complications such as fracture and pain. Both zoledronic acid and denosumab have been demonstrated to reduce skeletal related events. Comparative studies would suggest that densosumab may have an advantage over zoledronic acid.


Assuntos
Adenocarcinoma/complicações , Osteoporose/epidemiologia , Osteoporose/prevenção & controle , Neoplasias da Próstata/complicações , Adenocarcinoma/tratamento farmacológico , Antagonistas de Androgênios/efeitos adversos , Antagonistas de Androgênios/uso terapêutico , Anticorpos Monoclonais Humanizados/uso terapêutico , Conservadores da Densidade Óssea/uso terapêutico , Neoplasias Ósseas/epidemiologia , Denosumab , Difosfonatos/uso terapêutico , Humanos , Imidazóis/uso terapêutico , Masculino , Osteoporose/fisiopatologia , Neoplasias da Próstata/tratamento farmacológico , Fatores de Risco , Ácido Zoledrônico
8.
Int Orthop ; 34(3): 349-54, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19898821

RESUMO

The aim of this study was to determine whether there is a difference in functional outcome between the PFC Sigma fixed-bearing and rotating-platform total knee replacement systems. One hundred twenty patients were randomised to receive either a fixed-bearing or rotating-platform PFC Sigma total knee replacement. Range of movement (ROM), Oxford knee score (OKS) and Knee Society score (KSS) were assessed independently before and one year after surgery. Weight-bearing X-rays were taken immediately and one year post surgery to determine the incidence of osteolysis and loosening. At a mean follow-up of 13.4 months there was no statistically significant difference in mean ROM, OKS and KSS between the two groups. There was no evidence of osteolysis or loosening in either of the groups and no revision for infection or implant failure. This study shows that there is no statistically significant difference in functional outcome between the two types of implants at short-term follow-up.


Assuntos
Artroplastia do Joelho/métodos , Prótese do Joelho , Desenho de Prótese , Idoso , Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/reabilitação , Feminino , Seguimentos , Humanos , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Masculino , Osteólise , Medição da Dor , Falha de Prótese , Qualidade de Vida , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Resultado do Tratamento , Suporte de Carga