Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Lett ; 45(8): 2173, 2020 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-32287185

RESUMO

This publisher's note contains corrections to Opt. Lett.40, 5224 (2015).OPLEDP0146-959210.1364/OL.40.005224.

2.
Opt Express ; 26(8): 10119-10127, 2018 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-29715952

RESUMO

An efficient method has been developed to identify meat species by using laser-induced breakdown spectroscopy (LIBS). To improve the accuracy and stability of meat species identification, multiplicative scatter correction (MSC) was adopted to first pretreat the spectrum for correction of spectrum scatter. Then the corrected spectra were identified by using the K-nearest neighbor (KNN) model. The results showed that the identification rate improved from 94.17% to 100% and the prediction coefficient of variance (CV) decreased from 5.16% to 0.56%. This means that the accuracy and stability of meat species identification using MSC and LIBS simultaneously improved. In light of the findings, the proposed method can be a valuable tool for meat species identification using LIBS.


Assuntos
Carne , Análise Espectral/métodos , Lasers , Luz
3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(5): 1473-7, 2016 May.
Artigo em Chinês | MEDLINE | ID: mdl-30001037

RESUMO

LIBS mapping was used to analyze and detect the elemental distribution of iron ore surface with self-developed software and 532 nm Nd∶YAG laser. Firstly, in order to illustrate the relationship between element content and spectral intensity, the calibration curve was established by scanning the surface of standard sample. Then, a self-made sample was homogeneously divided into three parts that was pressed by three different standard iron ore powders. For the purpose of validating the mapping technology, a two-dimensional concentration distribution profile was generated after scanning the sample surface which was compared with surface morphology phase of the sample. Finally, with the resolution of 100 microns, the surface scanning analysis of the natural iron ore within the scope of 14 mm×11 mm was implemented. With this basis, the distribution profile of the elements Ca, Al, Ti and Mn were obtained, and the analysis results were compared with the surface morphology phase of the natural iron ore. The results showed that LIBS mapping technology could be used to achieve the qualitative analysis of component gradient distribution of the heterogeneous sample surface.

4.
Opt Lett ; 40(22): 5224-6, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26565840

RESUMO

The self-absorption effect is one of the main bottlenecks for the laser-induced breakdown spectroscopy (LIBS) technique. In this Letter, LIBS assisted by laser-stimulated absorption (LSA-LIBS) is proposed to solve this problem. The process of LSA in self-absorption reduction is discussed and confirmed. The serious self-absorption phenomena of spectral lines (K, Mn, and Al) were not observed in LSA-LIBS. The full width at half-maximum (FWHM) of K, Mn, and Al was reduced by about 58%, 25%, and 52%, respectively. The results demonstrate the capability of this approach to self-absorption reduction in the LIBS technique.

5.
Guang Pu Xue Yu Guang Pu Fen Xi ; 35(5): 1159-64, 2015 May.
Artigo em Chinês | MEDLINE | ID: mdl-26415419

RESUMO

Laser-induced breakdown spectroscopy (LIBS), a new kind of atomic spectrum analysis technology, has attracted much atterition of the researchers due to its characteristics of real-time, simultaneous multi-element analysis, and no sample preparation. However, the poor analytical sensitivity has been an important factor that restricts the development of this technology. LIBS based on resonance excitation combines atomic fluorescence spectroscopy and laser-induced breakdown spectroscopy and selectively excites the target elements. In this way, the analytical sensitivity of LIBS can be improved substantially and its application for trace elements detection is greatly expanded. In this paper, the research development of LIBS based on resonance excitation is summarized. The generation of atomic, fluorescence spectrum in laser-induced plasma, the typical classification and the basic principle of LIBS based on resonance. excitation are introduced. The influence of ablation laser energy, resonant laser energy and wavelength, delay between the ablation laser and the resonant laser, and the gate width on spectral enhancement are analyzed in detail. The application status and deficiencies of LIBS based on resonance excitation in the fields of metallurgy, environmental monitoring and isotope detection are elaborated. Future prospects of LIBS based on resonance excitation are also described.

6.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(1): 217-20, 2014 Jan.
Artigo em Chinês | MEDLINE | ID: mdl-24783564

RESUMO

The concentrations of vanadium and titanium elements in the steel samples were quantitatively analyzed by Laser-induced breakdown spectroscopy technique in the present paper. The lines of V (VI: 440.85 nm) and Ti (Ti I: 334.19 nm) were chosen as the quantitative analysis spectral lines, while spectral line of Fe (Fe I: 438.35 nm) was chosen as the internal calibration line due to it being the matrix element. Then the calibration curves of V and Ti elements were established with basic calibration method and internal calibration method respectively to quantitatively analyze the concentrations of vanadium and titanium elements in steel. The experimental results showed that the fitting correlation coefficient (R2) of vanadium and titanium elements are 0.9875 and 0.9909 when using basic calibration method, and their maximum relative errors of measurement are 11.09% and 4% respectively; while the fitting correlation coefficient (R2) of vanadium and titanium elements reachs 0.9952 and 0.9921 respectively when using internal calibration method, at the same time, the relative errors of measurement for vanadium and titanium elements were decreased to be lower than 4%. The results of this study demonstrated that the concentration measurement of vanadium and titanium elements in the steel was more suitable with internal calibration method in laser-induced breakdown spectroscopy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...