Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Foot Ankle Spec ; : 19386400241250154, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726657

RESUMO

INTRODUCTION: The Bartonícek/Rammelt classification is established for posterior malleolar fractures. It subdivides the fractures into 5 types and outlines treatment recommendations. This study aims to determine the intraobserver and interobserver reliability of the Bartonícek/Rammelt classification and investigates its applicability regarding treatment recommendations. MATERIALS AND METHODS: Computed tomography (CT) scans of 80 ankle fractures with a posterior malleolar fracture were analyzed by four observers at two different time points 30 days apart (d1 and d2). Intrarater and interrater reliability was measured using kappa values. The corresponding surgery rates of the fracture subtypes were analyzed, and the surgery rates were correlated with fragment sizes and displacements. RESULTS: A moderate interobserver reliability for d1 0.41 (CI 0.35-0.47) and d2 0.42 (CI 0.36-0.48) was detected. Intraobserver reliability was documented as perfect, with a mean kappa of 0.83. Type II fractures were operated on in 50% of cases. In 50% of type II cases, a nonoperative treatment was chosen. Fragment size correlated strongly with the chosen therapy, and osteosynthesis was performed significantly more often when the fragment size exceeded 3 cm3 (P < .01). CONCLUSIONS: The Bartonícek/Rammelt classification system showed moderate interobserver reliability and perfect to substantial intraobserver reliability. In clinical practice of this study cohort, the size of the posterior malleolar fragment rather than the dislocation and joint impaction seemed to have the decision to operate on type II or III fractures. Existing treatment recommendations based on the Bartonícek/Rammelt classification correspond to the therapy algorithm carried out in this cohort of patients.Levels of Evidence: Level III: Retrospective study.

2.
J Orthop ; 52: 102-106, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38440410

RESUMO

Purpose: Olecranon fractures are classified using the commonly accepted Mayo classification. Its reliability has been analyzed by means of radiographs. A CT scan is often obtained due to joint involvement. Purpose of this study was to evaluate the intra- and interobserver reliability of the Mayo classification based on CT examination. Methods: Radiographic and CT images of 20 olecranon fractures were classified by four surgeons at two time points 30 days apart. Intra- and interobserver reliability were assessed using kappa coefficients. Results: Mean intraobserver reliability between X-rays was substantial and between CTs almost perfect (0.76 and 0.82, respectively). Mean interobserver reliability was fair for X-rays and moderate for CTs (0.32 and 0.44, respectively). Conclusion: Despite the more detailed imaging compared with radiography only moderate interobserver reliability was found for the classification of olecranon fractures based on CT imaging. This might lead to inconsistent fracture classification in both scientific and clinical setting.

3.
Surg Radiol Anat ; 46(4): 473-482, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38329521

RESUMO

PURPOSE: Anatomical variations of the concave shaped retrocondylar ulnar groove (RUG) can contribute to ulnar nerve instability. However, there are currently limited available standardized data describing the anatomy of the RUG based on radiologic imaging, such as computed tomography (CT). This study aims to provide a comprehensive description and classification of RUG anatomy based on RUG angle measurements. METHODS: 400 CT scans of the elbows of adults showing no signs of osseous damage were evaluated. RUG angles were measured in four anatomically defined axial planes that spanned from the proximal to the distal end of the RUG. Furthermore, distance measurements at the medial epicondyle were conducted. A classification system for the RUG is proposed based on the acquired RUG angles, aiming to categorize the individual angles according to the 25th and 75th percentiles. RESULTS: RUG angles were significantly larger in males compared to females (p < 0.001) accompanied by larger distances including the off-set and height of the medial epicondyle (p < 0.001). RUG angles decreased from proximal to distal locations (p < 0.05). CONCLUSION: This study revealed that men exhibited larger RUG angles compared to women, indicating a less-concave shape of the RUG in men. Introducing an objective RUG classification system can improve our understanding of anatomical variations and potentially find application in diagnostics and preoperative planning.


Assuntos
Articulação do Cotovelo , Nervo Ulnar , Masculino , Adulto , Humanos , Feminino , Nervo Ulnar/anatomia & histologia , Articulação do Cotovelo/anatomia & histologia , Cotovelo/inervação , Tomografia Computadorizada por Raios X
4.
Pediatr Emerg Care ; 40(1): 2-5, 2024 Jan 01.
Artigo em Alemão, Inglês | MEDLINE | ID: mdl-36898049

RESUMO

OBJECTIVES: Buckle fractures of the distal forearm are a common fracture entity in children treated conservatively. Diagnostics primarily include radiographs in 2 planes. Inadequate images may occur in the mostly very young patients. Therefore, additional lateral radiographs are often obtained to assess a possible angular tilt. The aim of this study is to investigate whether a strictly lateral x-ray image has an influence on fracture management. METHODS: Seventy-three children with buckle fractures of the distal forearm were included in this retrospective analysis. All cases were analyzed by quality of radiographs, necessity to obtain an additional lateral radiograph, and what influence on fracture management resulted. Follow-up was performed 2 to 4 weeks after immobilization. RESULTS: Thirty-five girls and 38 boys with a mean age of 7.16 years were included; 40 had fractured right and 33 had fractured left arms, respectively. Isolated distal radius fractures occurred in 48 cases, isolated distal ulna fractures in 6 cases, and both bones in 19 cases. Initial radiographic images were evaluated as inadequate in 25 cases. In each of those cases, an additional lateral image was obtained by fluoroscopy without resulting in an alternated fracture management protocol, which was chosen conservatively in each case and resulted in excellent clinical outcome at follow-up examination. CONCLUSIONS: Based on our results, the acquisition of additional lateral radiographs seems to be unnecessary in the diagnostic procedure of buckle fractures of the distal forearm, in case a possible palmar or dorsal angulation cannot be entirely assessed on the initial set of radiographs. An additional lateral image had no influence on fracture management, which was chosen conservatively in every case and led to excellent clinical results.Level of evidence: level III.


Assuntos
Fraturas Múltiplas , Fraturas do Rádio , Fraturas da Ulna , Masculino , Criança , Feminino , Humanos , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/terapia , Antebraço , Estudos Retrospectivos , Fraturas da Ulna/diagnóstico por imagem , Fraturas da Ulna/terapia , Punho
5.
Arch Orthop Trauma Surg ; 143(10): 6243-6249, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37421514

RESUMO

PURPOSE: Postoperative soft tissue swelling is a significant factor influencing outcomes after elbow surgery. It can crucially affect important parameters such as postoperative mobilization, pain, and subsequently the range of motion (ROM) of the affected limb. Furthermore, lymphedema is considered a significant risk factor for numerous postoperative complications. Manual lymphatic drainage is nowadays part of the standardized post-treatment concept, basing on the concept of activating the lymphatic tissue to absorb stagnated fluid from the tissue into the lymphatic system. This prospective study aims to investigate the influence of technical device-assisted negative pressure therapy (NP) on early functional outcomes after elbow surgery. NP was therefore compared to manual lymphatic drainage (MLD). Is a technical device-based NP suitable for treatment of lymphedema after elbow surgery? METHODS: A total of 50 consecutive patients undergoing elbow surgery were enrolled. The patients were randomized into 2 groups. 25 participants per group were either treated by conventional MLD or NP. The primary outcome parameter was defined as the circumference of the affected limb in cm postoperative up to seven days postoperatively. The secondary outcome parameter was a subjective perception of pain (measured via visual analogue scale, VAS). All parameters were measured on each day of postoperative inpatient care. RESULTS AND CONCLUSION: NP showed an overall equivalent influence compared to MLD in reducing upper limb swelling after surgery. Moreover, the application of NP showed a significant decrease in overall pain perception compared to manual lymphatic drainage on days 2, 4 and 5 after surgery (p < 0.05). CONCLUSION: Our findings show that NP could be a useful supplementary device in clinical routine treating postoperative swelling after elbow surgery. Its application is easy, effective and comfortable for the patient. Especially due to the shortage of healthcare workers and physical therapists, there is a need for supportive measures which NP could be.


Assuntos
Linfedema , Drenagem Linfática Manual , Humanos , Drenagem Linfática Manual/efeitos adversos , Estudos Prospectivos , Cotovelo , Edema/etiologia , Edema/terapia , Linfedema/complicações , Dor , Resultado do Tratamento
6.
Eur J Orthop Surg Traumatol ; 33(8): 3643-3648, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37268872

RESUMO

PURPOSE: After major COVID-19 lockdown measures were suspended in 2021, E-scooter mobility regrew rapidly. In the meantime, multiple studies were published on the potential risks for e-scooter drivers and the necessity for wearing protective equipment. But did the drivers learn their lessons? METHODS: We observed data of E-scooter-related accidents admitted to the emergency department of a level 1 German trauma center in the year 2021 and compared the data with our previous report (July 2019-July 2020). RESULTS: N = 97 E-scooter-related accidents were included, marking a 50% increase when compared to the previous observation. Most patients were young adults (28.18 ± 1.13 years) with a notable shift towards a male population (25 vs. 63, p = 0.007). While the injury pattern remained unchanged, injury severity, reflected by a significant increase in shock room treatments (p = 0.005), hospital admissions (p = 0.45), and ICU admissions (p = 0.028), increased. Lastly, we report a higher injury severity of patients driving under the influence of alcohol, expressed by significant differences in hospital admissions, shock room treatments, ICU admissions, intracerebral bleeding (p < 0.0001), and injuries requiring surgery (p = 0.0017). CONCLUSION: The increase in injury severity and especially the substantial number of accidents due to driving under the influence of alcohol, are alarming for both trauma- and neurosurgeons. As the controversy surrounding the general use of E-scooters will continue, we urge representatives to intensify their efforts regarding prevention campaigns focusing on the potential dangers of E-scooters, especially when driving under the influence of alcohol.


Assuntos
Acidentes , Centros de Traumatologia , Adulto Jovem , Humanos , Masculino , Seguimentos , Estudos Retrospectivos , Serviço Hospitalar de Emergência , Acidentes de Trânsito/prevenção & controle
7.
Arch Orthop Trauma Surg ; 143(8): 5027-5034, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37042984

RESUMO

INTRODUCTION: Nailing of the proximal humerus is an established method for the treatment of proximal humerus fractures. Choice of the correct length for potentially four proximal locking screws is essential for postoperative outcome. Due to positioning of the patient, intraoperative determination of the correct length of the anteroposterior (AP) screw with the x-ray beam is particularly challenging even for experienced surgeons. We hypothesized that there would be a correlation between the projected lengths of the different proximal locking screws and therefore the length of the AP-screw could be determined based on the three lateromedial (LM) screws. MATERIALS AND METHODS: In this retrospective study (level of evidence: III) CT-scans of shoulders of 289 patients were 3D reconstructed with the program Horos. Using the manufacturer Stryker's instructions, the four proximal locking screws of the T2 Humeral Nail system were reproduced in the 3D reconstructed shoulders. The length of the AP-screw was correlated with the lengths of the LM-screws by Linear Regression and Multiple Linear Regression. RESULTS: The results of this study showed that the lengths of proximal locking screws in proximal humeral nailing correlated significantly with each other. Based on the given data, a formula could be established to calculate the length of the AP-screw based on the lengths of the LM-screws with a probability of 76.5%. CONCLUSIONS: This study was able to show that the length of the AP-screw could be determined from the intraoperatively measured lengths of the LM-screws. As our findings base on measurements performed in CT scans, clinical studies are needed to support our data.


Assuntos
Úmero , Fraturas do Ombro , Humanos , Estudos Retrospectivos , Úmero/cirurgia , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Tomografia Computadorizada por Raios X , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Placas Ósseas
8.
Surg Radiol Anat ; 45(5): 571-580, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36892617

RESUMO

The radiologic evaluation of the sagittal angulation of the distal humerus is commonly based on standard lateral radiographs. However, lateral radiographs do not allow to examine the lateral angulation of the capitulum and the trochlea, separately. Although this problem could be approached via computed tomography, there are no data available describing the difference between the angulation of the capitulum and trochlea. Therefore, we aimed to assess sagittal angles of the capitulum and trochlea in relation to the humeral shaft based on 400 CT-scans of the elbow in healthy adults. Angles were measured in sagittal planes at the capitulum center and three anatomically defined trochlea locations and were spanned between the axis of the joint component and the humerus shaft. Angles were tested for differences between measurement locations and correlation with patient characteristics (age, sex, trans-epicondylar distance). Angles increased from lateral to medial measurement locations (107.4 ± 9.6°, 167.4 ± 8.2°, 171.8 ± 7.3°, 179.1 ± 7.0°; p < 0.05). Largest angle differences were detected between the capitulum and trochlea with smallest angles measured at the capitulum. Patient characteristics did not correlate with angles (p > 0.05). Intra-rater-reliability was r = 0.79-0.86. As CT-imaging allows to distinguish between sagittal capitulum and trochlea locations, it might benefit the radiologic diagnostic of sagittal malalignments of the distal humerus at the capitulum and trochlea, separately.


Assuntos
Articulação do Cotovelo , Úmero , Adulto , Humanos , Reprodutibilidade dos Testes , Úmero/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Articulação do Cotovelo/diagnóstico por imagem , Radiografia
9.
Arch Orthop Trauma Surg ; 143(5): 2519-2527, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35731264

RESUMO

INTRODUCTION: Open reduction and internal fixation (ORIF) of comminuted coronal shear fractures of the distal humerus is challenging. When a concomitant lateral condyle fracture is present, it may be used for a trans-fracture approach to facilitate exposure and fracture reduction. This study aimed to investigate the frequency of lateral condyle fractures in coronal shear fractures of the distal humerus and analyze fracture reduction, fracture union and clinical results following ORIF through a trans-fracture approach. MATERIALS AND METHODS: All adult patients who underwent treatment for an acute distal humerus fracture during a three-year period in our level-one trauma center were identified. All fractures were classified according to the Orthopaedic Trauma Association (OTA/AO) fracture classification system and all B3 fractures were classified according to the Dubberley classification. B3 fractures with a concomitant radial condyle fracture were identified. The clinical and radiological results, (Mayo Elbow Performance Score = MEPS, Visual Analogue Scale = VAS, range of motion), complications and revision surgeries were analyzed. RESULTS: 53 patients (mean age 52 ± 19 years) were identified. 13 fractures (24.5%) were B3 fractures. Four of them (30.8%) had a concomitant radial condyle fracture. All of these patients underwent ORIF with headless cannulated compression screws and a (postero-)lateral locking plate through a trans-fracture approach. At a minimum follow-up of 24 months, the MEPS was 88 ± 12 points, the VAS was 2 ± 1 and the range of motion was 118° ± 12°. All fractures showed anatomic reduction. One patient developed partial avascular necrosis and underwent arthrolysis at 6 months. One patient underwent partial hardware removal and lateral collateral ligament bracing at 6 months. CONCLUSIONS: Lateral condyle fractures are present in about one third of coronal shear fractures of the distal humerus. This injury can be used for a trans-fracture approach to facilitate exposure and to reliably achieve anatomic fracture reduction.


Assuntos
Articulação do Cotovelo , Fraturas Cominutivas , Fraturas do Úmero , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Fraturas do Úmero/cirurgia , Fixação Interna de Fraturas/métodos , Úmero , Redução Aberta/métodos , Articulação do Cotovelo/cirurgia , Fraturas Cominutivas/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Amplitude de Movimento Articular
10.
J Hand Surg Am ; 2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36400651

RESUMO

PURPOSE: Indirect fixation of coronoid process fractures of the ulna, especially arthroscopically, offers the possibility to avoid extensive medial surgical approaches. However, optimal placement of K-wires for cannulated screw fixation is technically challenging. The aim of the present study was to present guide values for K-wire placement for indirect screw fixation of coronoid tip (COT) and anteromedial facet (AMF) fractures of the ulna. METHODS: Computed tomography scans of the elbows of 197 patients with an uninjured ulna were identified and evaluated following a standard measuring protocol. Optimal placement of K-wires was defined as the bisector between the anterior and articular cortex while respecting a 1.6-mm safe zone for each placement. This placement of the K-wires in the COT and the AMF was analyzed by measuring the wire angulation in relation to the posterior ulnar cortex (AUC), the distance from the entry point to the posterior olecranon edge (DPE), and the intraosseous length (IOL). Because the coronoid has a curved shape, measurements of the COT and AMF were expected to differ significantly. Sex was also expected to influence measurements. To determine whether this optimal placement of K-wires can be reliably identified, interobserver and intraobserver reliabilities were evaluated. RESULTS: To address tip fragments, we determined a mean AUC of 64°, DPE of 36 mm, and IOL of 38 mm. Regarding wire placement toward the AMF, the means for the AUC, DPE, and IOL were 79°, 27 mm, and 33 mm, respectively. Statistically significant differences were found between the COT and the AMF for the AUC, DPE, and IOL. Our measuring protocol showed good interobserver and intraobserver reliability. CONCLUSIONS: K-wire placement toward the COT demands a smaller angle, a longer IOL, and a more distal entry point than wires placed toward AMF. These differences reflect the curved and complex anatomy of the coronoid. CLINICAL RELEVANCE: This measuring algorithm can be used to plan osteosynthesis, and the obtained reference values can help understand the coronoid's complex anatomy.

11.
J Shoulder Elbow Surg ; 31(8): 1666-1673, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35247574

RESUMO

BACKGROUND: The purpose of this study was to investigate the primary stability and displacement tendencies of an external fixation system in 2 different configurations in comparison to locking plate fixation in a 3-part proximal humeral fracture model. METHODS: Twenty-one fresh-frozen human cadaveric proximal humeral specimens were divided into 3 groups of 7 stripped specimens. An unstable 3-part fracture of the proximal humerus was set. Construct A consisted of the Galaxy Fixation Shoulder System, with fixation in accordance with the manufacturer's recommended technique (3 pairs of threaded wires). Construct B was fixed with an additional pair of threaded wires according to the recommendations of Gumina et al (4 pairs of threaded wires). The remaining 7 specimens were fixed with a locking plate. By use of an optical motion capture system, relative motion at the fracture site and failure load were evaluated during a cyclic loading protocol. RESULTS: Plate osteosynthesis showed the highest cyclic load to failure (895 ± 239 N; range, 597-1135 N), followed by construct B (692 ± 121 N; range, 432-788 N) and construct A (350 ± 190 N; range, 139-615 N). Statistically significant differences were found between plating and construct A (P < .001), between plating and construct B (P = .031), and between construct B and construct A (P = .013). Relative motion at the fracture site, in terms of change in distance during cyclic loading, was lowest with construct B measured at the peak load of 395 N after 11 steps (1.73 ± 1.98 mm; range, 0.53-5.96 mm) and highest with construct A (8.46 ± 10.67 mm; range, 2.26-20.79 mm). Angular change measured at the peak load after 11 steps was lowest with construct B (1.19° ± 0.36°; range, 0.59°-1.7°) and highest with construct A (2.44° ± 1.63°; range, 0.77°-4.04°). Statistically significant differences were found between construct A and construct B and between construct A and plating at various steps of cyclic loading. CONCLUSION: In this biomechanical study of unstable 3-part proximal humeral fractures, locking plate osteosynthesis demonstrated the highest possible load application. External fixator application with 8 threaded wires (construct B) revealed the least relative motion at the fracture site, without a statistically significant difference compared with locking plates. It therefore represents another valid technique for treatment regarding primary stability. The use of external fixator application with 6 threaded wires (construct A) resulted in the lowest stability and the highest rates of displacement.


Assuntos
Fraturas do Úmero , Fraturas do Ombro , Fenômenos Biomecânicos , Placas Ósseas , Cadáver , Fixadores Externos , Fixação de Fratura/métodos , Fixação Interna de Fraturas/métodos , Humanos , Úmero/cirurgia , Ombro , Fraturas do Ombro/cirurgia
12.
Eur J Orthop Surg Traumatol ; 32(4): 641-647, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34061254

RESUMO

PURPOSE: E-scooters are a new type of urban transportation utilized in Germany since June 2019, primarily in larger cities in the context of sharing offers. Such electrically operated standing scooters can be driven at a maximum speed of 20 km/h. A helmet is not mandatory. The aim of this prospective study is to document the injury patterns over the period of 1 year and compare our findings with already available data. METHODS: Over a period of 1 year (July 2019-July 2020), data on E-scooter-related accidents treated at a level 1 trauma center of a major German city were prospectively documented. Injury patterns were analyzed, and epidemiological data evaluated. RESULTS: Fifty-nine (35 female, 24 male) accidents were included in the observation period. Mean age of accident victims was 30.03 years (± 9.32). Alcohol influence at the time of accident was detected in 9 cases (15.25%). Many of the accident victims suffered multiple injuries. Most of the injuries were upper (50.84%) and lower extremity (47.45%) as well as craniofacial injuries (62.71%). A helmet was not worn in any of the cases. CONCLUSION: In the year following their introduction, E-scooter-related accidents have led to an additional burden on the emergency capacities of the involved University Hospital, especially in the summer months of 2019. Protective equipment is de facto not worn. Injuries to the extremities, head, and face were most common. None of the accident victims died. This coincides with results from other major cities in national and international comparison. A more intensive education about injury consequences of unprotected E-scooter use and the discussion of a possible obligation to wear a helmet and further protection equipment for the extremities should take place.


Assuntos
Acidentes de Trânsito , Centros de Traumatologia , Adulto , Feminino , Dispositivos de Proteção da Cabeça , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos
13.
Ann Anat ; 240: 151878, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34863911

RESUMO

The aim of this study was to investigate whether life-like fractures of human cadaveric mandibles with a focus on the condylar process and the intact soft tissue envelope could be simulated. A total of nine fresh-frozen human head specimens were fractured in a custom-made drop-test bench. This reproducible method is based on a weight falling from a defined height onto the fixed specimens, simulating a direct blow to the symphysis of the mandible. All the fractures were analyzed by fluoroscopy and CT-scans. In all the specimens that were included in this study, several typical lesions could be created, resulting in a total of 27 mandible fractures. Seven condylar head fractures with intracapsular fracture patterns, three high, two low and five subcondylar fractures as well as different corpus fractures occurred. Human cadaveric mandibles as part of a complete head specimen with intact soft tissue can be successfully fractured by means of a drop-test bench setup. The amount of load and the exact angle at which the load is applied seem to be of high relevance. Such fractured specimens can be implemented in surgical education courses to teach and improve osteosynthetic techniques.


Assuntos
Fraturas Mandibulares , Cirurgia Bucal , Fixação Interna de Fraturas , Humanos , Mandíbula/cirurgia , Côndilo Mandibular , Fraturas Mandibulares/cirurgia , Tomografia Computadorizada por Raios X
14.
Arch Orthop Trauma Surg ; 141(9): 1615-1624, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33877448

RESUMO

INTRODUCTION: Radial head fractures account for the majority of bony elbow injuries. The individual treatment options have been described in detail. In some cases, however, an unusual concomitant injury occurs, which can significantly impede primary osteosynthesis and healing. This concomitant injury can be an interposing cartilaginous capitellar fragment. METHODS: This retrospective study describes four cases of trapped cartilage fragments of the capitellum that compromised primary osteosynthesis or primary conservative healing of a radial head fracture. Radiological imaging, function and pain level are presented pre- and postoperatively (mean follow-up 9.25 months). RESULTS: None of the four cases showed preoperative evidence of an incarcerated cartilage fragment of the capitellum. They all showed limited elbow range of motion. CT examinations were performed in all cases. In each case, the cartilage fragment was first sighted upon surgery, subsequently removed and the fractures treated with ORIF. Mean follow-up was of 9.25 months. All fractures healed, with excellent function and low pain scores. CONCLUSIONS: This study presents rare cases of a trapped humeral cartilage fragment in radial head fractures. Radiological imaging including CT scans cannot reliably detect this concomitant injury. Therefore, this problem becomes apparent and treatable only during surgery. A high degree of suspicion is necessary especially in patients with minimally displaced fractures associated with limited elbow motion and a gap at the fracture site as treating these injuries conservatively may lead to poor outcome.


Assuntos
Articulação do Cotovelo , Fraturas do Rádio , Adulto , Idoso , Cartilagem , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Rádio (Anatomia) , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Estudos Retrospectivos
15.
Arch Orthop Trauma Surg ; 141(10): 1683-1690, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33078271

RESUMO

INTRODUCTION: In this study we investigated if realistic fracture patterns around the hip can be produced on human cadaveric specimens with intact soft tissue envelope. Possible applications of such fractured specimens would be in surgical training. MATERIALS AND METHODS: 7 cadaveric specimens (2 male, 5 female, 2 formalin-fixed, 5 fresh-frozen) were fractured. 2 specimens were fractured on both femurs, 5 only on one side, resulting in 9 fractures total. 5 fractures were set in our custom-made drop-test bench, 2 fractures by inducing axial force using a hammer, and the remaining 2 fractures by a direct dorsal approach and a chisel. AO/OTA and Pauwels classification were used to classify the fractures on the specimens by two independent trauma surgeons. RESULTS: In our drop-test bench, axial load with the femur adducted by 10° resulted in an intertrochanteric fracture (AO type A1.3), adducted by 20° resulted in a femoral neck fracture (Pauwels type III). Fracture induction using a hammer resulted in two intertrochanteric fractures (AO type A2.2 right, A3.3 left). The use of a chisel resulted in both cases in a femoral neck fracture. The acetabulum could be fractured multifragmentarily through use of a hemiprosthesis as a stamp. CONCLUSION: A high energetic impulse induced by a custom-made drop-test bench can successfully simulate realistic proximal femur and acetabular fractures in cadaveric specimens with intact soft tissue. Furthermore, axial load using a hammer as well as using a chisel through a direct dorsal approach represent additional methods for fracture induction. These pre-fractured specimens can be utilized in surgical education to provide a realistic teaching experience for specialized trauma education courses.


Assuntos
Fraturas do Colo Femoral , Fraturas do Quadril , Cirurgiões , Feminino , Fraturas do Colo Femoral/cirurgia , Fêmur , Fraturas do Quadril/cirurgia , Humanos , Masculino
16.
J Hand Surg Am ; 45(10): 987.e1-987.e8, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32499069

RESUMO

PURPOSE: The aim of this study was to compare several osteosynthesis techniques (intramedullary headless compression screws, T-plates, and Kirschner wires) for distal epiphyseal fractures of proximal phalanges in a human cadaveric model. METHODS: A total of 90 proximal phalanges from 30 specimens (index, ring, and middle fingers) were used for this study. After stripping off all soft tissue, a transverse distal epiphyseal fracture was simulated at the proximal phalanx. The 30 specimens were randomly assigned to 1 fixation technique (30 per technique), either a 3.0-mm intramedullary headless compression screw, locking plate fixation with a 2.0-mm T-plate, or 2 oblique 1.0-mm Kirschner wires. Displacement analysis (bending, distraction, and torsion) was performed using optical tracking of an applied random speckle pattern after osteosynthesis. Biomechanical testing was performed with increasing cyclic loading and with cyclic load to failure using a biaxial torsion-tension testing machine. RESULTS: Cannulated intramedullary compression screws showed significantly less displacement at the fracture site in torsional testing. Furthermore, screws were significantly more stable in bending testing. Kirschner wires were significantly less stable than plating or screw fixation in any cyclic load to failure test setup. CONCLUSIONS: Intramedullary compression screws are a highly stable alternative in the treatment of transverse distal epiphyseal phalangeal fractures. Kirschner wires seem to be inferior regarding displacement properties and primary stability. CLINICAL RELEVANCE: Fracture fixation of phalangeal fractures using plate osteosynthesis may have the advantage of a very rigid reduction, but disadvantages such as stiffness owing to the more invasive surgical approach and soft tissue irritation should be taken into account. Headless compression screws represent a minimally invasive choice for fixation with good biomechanical properties.


Assuntos
Fios Ortopédicos , Fraturas Ósseas , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Cadáver , Fixação Interna de Fraturas , Fraturas Ósseas/cirurgia , Humanos
17.
Arch Orthop Trauma Surg ; 140(3): 425-432, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31807851

RESUMO

INTRODUCTION: Surgical education consists often times of a discrepancy between necessary amount of provided operative teaching and amount of organizational and ward duties. Operative education is often cut to a minimum. As public awareness toward surgical competence raises, so must the educational system. Courses that provide pre-fractured cadaveric specimens can facilitate surgical teaching realistically, prior to operating on living patients. The aim of this study is to introduce a realistic distal radius fracture simulation setup. MATERIALS AND METHODS: 12 cadaveric specimens (3 male, 9 female) were fixed onto a custom drop-test-bench in the hyperextension of the wrist. The forearm was cut midway between elbow and carpus. The distal part of the forearm was potted, and the specimen was exposed to a high energetic impulse. CT imaging was performed after fracture simulation to detect the exact fracture patterns. We used the AO/ASIF recommendations and four-corner concept to classify the achieved fractures by two independent trauma surgeons. RESULTS: All cadaveric specimens could be successfully fractured. 11 fractures were classified as type 23C3.2 and one was classified as type 23C3.3, as additional fracture of diaphysis occurred. Subclassification according to the four-corner concept showed all fractures to be type C. A concomitant ulnar styloid fracture was observed in 4 cases. Furthermore, all cases showed at least one fragment involving the sigmoid notch. There was no statistically significant correlation found regarding Hounsfield Units (HU) and age (p value 0.402), as well as HU and required kinetic energy (p value 0.063). CONCLUSION: A high energetic impulse induced by a custom-made drop-test bench can successfully simulate realistic distal radius fractures in cadaveric specimens with intact soft tissue. Furthermore, these pre-fractured specimens can be utilized in surgical education to provide a teaching experience as realistic as possible without harming living patients.


Assuntos
Modelos Biológicos , Procedimentos Ortopédicos/educação , Fraturas do Rádio/cirurgia , Cirurgiões/educação , Feminino , Humanos , Masculino , Treinamento por Simulação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...