Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Appl Clin Med Phys ; 22(5): 97-109, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33939253

RESUMO

PURPOSE: The purpose of this work was to estimate and compare breast and lung doses of chest CT scans using organ-based tube current modulation (OBTCM) to those from conventional, attenuation-based automatic tube current modulation (ATCM) across a range of patient sizes. METHODS: Thirty-four patients (17 females, 17 males) who underwent clinically indicated CT chest/abdomen/pelvis (CAP) examinations employing OBTCM were collected from two multi-detector row CT scanners. Patient size metric was assessed as water equivalent diameter (Dw ) taken at the center of the scan volume. Breast and lung tissues were segmented from patient image data to create voxelized models for use in a Monte Carlo transport code. The OBTCM schemes for the chest portion were extracted from the raw projection data. ATCM schemes were estimated using a recently developed method. Breast and lung doses for each TCM scenario were estimated for each patient model. CTDIvol -normalized breast (nDbreast ) and lung (nDlung ) doses were subsequently calculated. The differences between OBTCM and ATCM normalized organ dose estimates were tested using linear regression models that included CT scanner and Dw as covariates. RESULTS: Mean dose reduction from OBTCM in nDbreast was significant after adjusting for the scanner models and patient size (P = 0.047). When pooled with females and male patient, mean dose reduction from OBTCM in nDlung was observed to be trending after adjusting for the scanner model and patient size (P = 0.085). CONCLUSIONS: One specific manufacturer's OBTCM was analyzed. OBTCM was observed to significantly decrease normalized breast relative to a modeled version of that same manufacturer's ATCM scheme. However, significant dose savings were not observed in lung dose over all. Results from this study support the use of OBTCM chest protocols for females only.


Assuntos
Mama , Tomografia Computadorizada por Raios X , Mama/diagnóstico por imagem , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação
2.
Med Phys ; 48(1): 523-532, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33128259

RESUMO

PURPOSE: Task Group Report 195 of the American Association of Physicists in Medicine contains reference datasets for the direct comparison of results among different Monte Carlo (MC) simulation tools for various aspects of imaging research that employs ionizing radiation. While useful for comparing and validating MC codes, that effort did not provide the information needed to compare absolute dose estimates from CT exams. Therefore, the purpose of this work is to extend those efforts by providing a reference dataset for benchmarking fetal dose derived from MC simulations of clinical CT exams. ACQUISITION AND VALIDATION METHODS: The reference dataset contains the four necessary elements for validating MC engines for CT dosimetry: (a) physical characteristics of the CT scanner, (b) patient information, (c) exam specifications, and (d) fetal dose results from previously validated and published MC simulations methods in tabular form. Scanner characteristics include non-proprietary descriptions of equivalent source cumulative distribution function (CDF) spectra and bowtie filtration profiles, as well as scanner geometry information. Additionally, for the MCNPX MC engine, normalization factors are provided to convert raw simulation results to absolute dose in mGy. The patient information is based on a set of publicly available fetal dose models and includes de-identified image data; voxelized MC input files with fetus, uterus, and gestational sac identified; and patient size metrics in the form of water equivalent diameter (Dw ) z-axis distributions from a simulated topogram (Dw,topo ) and from the image data (Dw,image ). Exam characteristics include CT scan start and stop angles and table and patient locations, helical pitch, nominal collimation and measured beam width, and gantry rotation time for each simulation. For simulations involving estimating doses from exams using tube current modulation (TCM), a realistic TCM scheme is presented that is estimated based upon a validated method. (d) Absolute and CTDIvol -normalized fetal dose results for both TCM and FTC simulations are given for each patient model under each scan scenario. DATA FORMAT AND USAGE NOTES: Equivalent source CDFs and bowtie filtration profiles are available in text files. Image data are available in DICOM format. Voxelized models are represented by a header followed by a list of integers in a text file representing a three-dimensional model of the patient. Size distribution metrics are also given in text files. Results of absolute and normalized fetal dose with associated MC error estimates are presented in tabular form in an Excel spreadsheet. All data are stored on Zenodo and are publicly accessible using the following link: https://zenodo.org/record/3959512. POTENTIAL APPLICATIONS: Similar to the work of AAPM Report 195, this work provides a set of reference data for benchmarking fetal dose estimates from clinical CT exams. This provides researchers with an opportunity to compare MC simulation results to a set of published reference data as part of their efforts to validate absolute and normalized fetal dose estimates. This could also be used as a basis for comparison to other non-MC approaches, such as deterministic approaches, or to commercial packages that provide estimates of fetal doses from clinical CT exams.


Assuntos
Benchmarking , Tomografia Computadorizada por Raios X , Feminino , Feto , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação
3.
Med Phys ; 46(6): 2729-2743, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30893477

RESUMO

PURPOSE: The purpose of this work was to estimate scanner-independent CTDIvol -to-fetal-dose coefficients for tube current-modulated (TCM) and fixed tube current (FTC) computed tomography (CT) examinations of pregnant patients of various gestational ages undergoing abdominal/pelvic CT examinations. METHODS: For 24 pregnant patients of gestational age from <5 to 36 weeks who underwent clinically indicated CT examinations, voxelized models of maternal and fetal (or embryo) anatomy were created from abdominal/pelvic image data. Absolute fetal dose (Dfetus ) was estimated using Monte Carlo (MC) simulations of helical scans covering the abdomen and pelvis for TCM and FTC scans. Estimated TCM schemes were generated for each patient model using a validated method that accounts for patient attenuation and scanner output limits for one scanner model and were incorporated into MC simulations. FTC scans were also simulated for each patient model with multidetector row CT scanners from four manufacturers. Normalized fetal dose estimates, nDfetus , was obtained by dividing Dfetus from the MC simulations by CTDIvol . Patient size was described using water equivalent diameter (Dw ) measured at the three-dimensional geometric centroid of the fetus. Fetal depth (DEf ) was measured from the anterior skin surface to the anterior part of the fetus. nDfetus and Dw were correlated using an exponential model to develop equations for fetal dose conversion coefficients for TCM and FTC abdominal/pelvic CT examinations. Additionally, bivariate linear regression was performed to analyze the correlation of nDfetus with Dw and fetal depth (DEf ). For one scanner model, nDfetus from TCM was compared to FTC and the size-specific dose estimate (SSDE) conversion coefficients (f-factors) from American Association of Physicists in Medicine (AAPM) Report 204. nDfetus from FTC simulations was averaged across all scanners for each patient ( n D fetus ¯ ) . n D fetus ¯ was then compared with SSDE f-factors and correlated with Dw using an exponential model and with Dw and DEf using a bivariate linear model. RESULTS: For TCM, the coefficient of determination (R2 ) of nDfetus and Dw was observed to be 0.73 using an exponential model. Using the bivariate linear model with Dw and DEf , an R2 of 0.78 was observed. For the TCM technology modeled, TCM yielded nDfetus values that were on average 6% and 17% higher relative to FTC and SSDE f-factors, respectively. For FTC, the R2 of n D fetus ¯ with respect to Dw was observed to be 0.64 using an exponential model. Using the bivariate linear model, an R2 of 0.75 was observed for n D fetus ¯ with respect to Dw and DEf . A mean difference of 0.4% was observed between n D fetus ¯ and SSDE f-factors. CONCLUSION: Good correlations were observed for nDfetus from TCM and FTC scans using either an exponential model with Dw or a bivariate linear model with both Dw and DEf . These results indicate that fetal dose from abdomen/pelvis CT examinations of pregnant patients of various gestational ages may be reasonably estimated with models that include (a) scanner-reported CTDIvol and (b) Dw as a patient size metric, in addition to (c) DEf if available. These results also suggest that SSDE f-factors may provide a reasonable (within ±25%) estimate of nDfetus for TCM and FTC abdomen/pelvis CT exams.


Assuntos
Abdome/diagnóstico por imagem , Feto/efeitos da radiação , Pelve/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/efeitos adversos , Condutividade Elétrica , Feminino , Humanos , Método de Monte Carlo , Gravidez , Radiometria
4.
Med Phys ; 46(2): 902-912, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30565704

RESUMO

PURPOSE: Size-specific dose estimates (SSDE) conversion factors have been determined by AAPM Report 204 to adjust CTDIvol to account for patient size but were limited to body CT examinations. The purpose of this work was to determine conversion factors that could be used for an SSDE for helical, head CT examinations for patients of different sizes. METHODS: Validated Monte Carlo (MC) simulation methods were used to estimate dose to the center of the scan volume from a routine, helical head examination for a group of patient models representing a range of ages and sizes. Ten GSF/ICRP voxelized phantom models and five pediatric voxelized patient models created from CT image data were used in this study. CT scans were simulated using a Siemens multidetector row CT equivalent source model. Scan parameters were taken from the AAPM Routine Head protocols for a fixed tube current (FTC), helical protocol, and scan lengths were adapted to the anatomy of each patient model. MC simulations were performed using mesh tallies to produce voxelized dose distributions for the entire scan volume of each model. Three tally regions were investigated: (1) a small 0.6 cc volume at the center of the scan volume, (2) 0.8-1.0 cm axial slab at the center of the scan volume, and (3) the entire scan volume. Mean dose to brain parenchyma for all three regions was calculated. Mean bone dose and a mass-weighted average dose, consisting of brain parenchyma and bone, were also calculated for the slab in the central plane and the entire scan volume. All dose measures were then normalized by CTDIvol for the 16 cm phantom (CTDIvol,16 ). Conversion factors were determined by calculating the relationship between normalized doses and water equivalent diameter (Dw ). RESULTS: CTDIvol,16 -normalized mean brain parenchyma dose values within the 0.6 cc volume, 0.8-1.0 cm central axial slab, and the entire scan volume, when parameterized by Dw , had an exponential relationship with a coefficient of determination (R2 ) of 0.86, 0.84, and 0.88, respectively. There was no statistically significant difference between the conversion factors resulting from these three different tally regions. Exponential relationships between CTDIvol,16 -normalized mean bone doses had R2 values of 0.83 and 0.87 for the central slab and for the entire scan volume, respectively. CTDIvol,16 -normalized mass-weighted average doses had R2 values of 0.39 and 0.51 for the central slab and for the entire scan volume, respectively. CONCLUSIONS: Conversion factors that describe the exponential relationship between CTDIvol,16 -normalized mean brain dose and a size metric (Dw ) for helical head CT examinations have been reported for two different interpretations of the center of the scan volume. These dose descriptors have been extended to describe the dose to bone in the center of the scan volume as well as a mass-weighted average dose to brain and bone. These may be used, when combined with other efforts, to develop an SSDE dose coefficients for routine, helical head CT examinations.


Assuntos
Encéfalo/diagnóstico por imagem , Cabeça/diagnóstico por imagem , Método de Monte Carlo , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada Espiral/métodos , Adulto , Osso e Ossos/diagnóstico por imagem , Osso e Ossos/efeitos da radiação , Encéfalo/efeitos da radiação , Criança , Pré-Escolar , Simulação por Computador , Feminino , Cabeça/efeitos da radiação , Humanos , Processamento de Imagem Assistida por Computador/métodos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Neoplasias/radioterapia , Órgãos em Risco/efeitos da radiação , Radiometria/métodos , Dosagem Radioterapêutica
5.
Med Phys ; 45(10): 4667-4682, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30118143

RESUMO

PURPOSE: The purpose of this study was to estimate the radiation dose to the lung and breast as well as the effective dose from tube current modulated (TCM) lung cancer screening (LCS) scans across a range of patient sizes. METHODS: Monte Carlo (MC) methods were used to calculate lung, breast, and effective doses from a low-dose LCS protocol for a 64-slice CT that used TCM. Scanning parameters were from the protocols published by AAPM's Alliance for Quality CT. To determine lung, breast, and effective doses from lung cancer screening, eight GSF/ICRP voxelized phantom models with all radiosensitive organs identified were used to estimate lung, breast, and effective doses. Additionally, to extend the limited size range provided by the GSF/ICRP phantom models, 30 voxelized patient models of thoracic anatomy were generated from LCS patient data. For these patient models, lung and breast were semi-automatically segmented. TCM schemes for each of the GSF/ICRP phantom models were generated using a validated method wherein tissue attenuation and scanner limitations were used to determine the TCM output as a function of table position and source angle. TCM schemes for voxelized patient models were extracted from the raw projection data. The water equivalent diameter, Dw, was used as the patient size descriptor. Dw was estimated for the GSF/ICRP models. For the thoracic patient models, Dw was extracted from the DICOM header of the CT localizer radiograph. MC simulations were performed using the TCM scheme for each model. Absolute organ doses were tallied and effective doses were calculated using ICRP 103 tissue weighting factors for the GSF/ICRP models. Metrics of scanner radiation output were determined based on each model's TCM scheme, including CTDIvol , dose length product (DLP), and CTDIvol, Low Att , a previously described regional metric of scanner output covering most of the lungs and breast. All lung and breast doses values were normalized by scan-specific CTDIvol and CTDIvol, Low Att . Effective doses were normalized by scan-specific CTDIvol and DLP. Absolute and normalized doses were reported as a function of Dw. RESULTS: Lung doses normalized by CTDIvol, Low Att were modeled as an exponential relationship with respect to Dw with coefficients of determination (R2 ) of 0.80. Breast dose normalized by CTDIvol, Low Att was modeled with an exponential relationship to Dw with an R2 of 0.23. For all eight GSF/ICRP phantom models, the effective dose using TCM protocols was below 1.6 mSv. Effective doses showed some size dependence but when normalized by DLP demonstrated a constant behavior. CONCLUSION: Lung, breast, and effective doses from LCS CT exams with TCM were estimated with respect to patient size. Normalized lung dose can be reasonably estimated with a measure of a patient size such as Dw and regional metric of CTDIvol covering the thorax such as CTDIvol, Low Att , while normalized breast dose can also be estimated with a regional metric of CTDIvol but with a larger degree of variability than observed for lung. Effective dose normalized by DLP can be estimated with a constant multiplier.


Assuntos
Tamanho Corporal , Mama/efeitos da radiação , Neoplasias Pulmonares/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Pulmão/efeitos da radiação , Programas de Rastreamento , Doses de Radiação , Tomografia Computadorizada por Raios X , Feminino , Humanos , Masculino , Método de Monte Carlo , Imagens de Fantasmas , Radiometria , Tomografia Computadorizada por Raios X/instrumentação
6.
PLoS One ; 10(10): e0139451, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26431174

RESUMO

PURPOSE: In the present study we investigated a combination of diffusion tensor imaging (DTI) and magnetic resonance spectroscopic (MRS) biomarkers in order to predict neurological impairment in patients with cervical spondylosis. METHODS: Twenty-seven patients with cervical spondylosis were evaluated. DTI and single voxel MRS were performed in the cervical cord. N-acetylaspartate (NAA) and choline (Cho) metabolite concentration ratios with respect to creatine were quantified, as well as the ratio of choline to NAA. The modified mJOA scale was used as a measure of neurologic deficit. Linear regression was performed between DTI and MRS parameters and mJOA scores. Significant predictors from linear regression were used in a multiple linear regression model in order to improve prediction of mJOA. Parameters that did not add value to model performance were removed, then an optimized multiparametric model was established to predict mJOA. RESULTS: Significant correlations were observed between the Torg-Pavlov ratio and FA (R2 = 0.2021, P = 0.019); DTI fiber tract density and FA, MD, Cho/NAA (R2 = 0.3412, P = 0.0014; R2 = 0.2112, P = 0.016; and R2 = 0.2352, P = 0.010 respectively); along with FA and Cho/NAA (R2 = 0.1695, P = 0.033). DTI fiber tract density, MD and FA at the site of compression, along with Cho/NAA at C2, were significantly correlated with mJOA score (R2 = 0.05939, P < 0.0001; R2 = 0.4739, P < 0.0001; R2 = 0.7034, P < 0.0001; R2 = 0.4649, P < 0.0001). A combination biomarker consisting of DTI fiber tract density, MD, and Cho/NAA showed the best prediction of mJOA (R2 = 0.8274, P<0.0001), with post-hoc tests suggesting fiber tract density, MD, and Cho/NAA were all significant contributors to predicting mJOA (P = 0.00053, P = 0.00085, and P = 0.0019, respectively). CONCLUSION: A linear combination of DTI and MRS measurements within the cervical spinal cord may be useful for accurately predicting neurological deficits in patients with cervical spondylosis. Additional studies may be necessary to validate these observations.


Assuntos
Ácido Aspártico/análogos & derivados , Colina/análise , Imagem de Tensor de Difusão , Transtornos Neurológicos da Marcha/etiologia , Parestesia/etiologia , Espectroscopia de Prótons por Ressonância Magnética , Compressão da Medula Espinal/etiologia , Medula Espinal/patologia , Espondilose/complicações , Adulto , Idoso , Envelhecimento/patologia , Ácido Aspártico/análise , Creatinina/análise , Feminino , Transtornos Neurológicos da Marcha/patologia , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Cervicalgia/etiologia , Cervicalgia/patologia , Fibras Nervosas/patologia , Parestesia/patologia , Estudos Prospectivos , Compressão da Medula Espinal/patologia , Estenose Espinal/complicações , Estenose Espinal/patologia , Espondilose/patologia , Adulto Jovem
7.
J Neurooncol ; 122(3): 497-505, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25773062

RESUMO

Bevacizumab is a therapeutic drug used in treatment of recurrent glioblastoma to inhibit angiogenesis. Treatment response is often monitored through the use of perfusion MRI measures of cerebral blood volume, flow, and other pharmacokinetic parameters; however, most methods for deriving these perfusion parameters can produce errors depending on bolus kinetics. Recently, a number of new methods have been developed to overcome these challenges. In the current study we examine cerebral blood volume and blood flow characteristics in 45 recurrent glioblastoma patients before and after treatment with bevacizumab. Perfusion MRI data was processed using a standard single value decomposition (SVD) technique, two block-circulant SVD techniques, and a Bayesian estimation technique. A proportional hazards model showed that patients with a large decrease in relative blood volume (RBV) after treatment had extended overall survival (P = 0.0048). Patients with large pre-treatment relative blood flow (RBF) showed extended progression-free survival (P = 0.0216) and overall survival (P = 0.0112), and patients with a large decrease in RBF following treatment showed extended overall survival (P = 0.0049). These results provide evidence that blood volume and blood flow measurements can be used as biomarkers in patients treated with bevacizumab.


Assuntos
Inibidores da Angiogênese/uso terapêutico , Bevacizumab/uso terapêutico , Neoplasias Encefálicas , Glioblastoma , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Adulto , Idoso , Análise de Variância , Neoplasias Encefálicas/tratamento farmacológico , Neoplasias Encefálicas/mortalidade , Neoplasias Encefálicas/patologia , Feminino , Glioblastoma/tratamento farmacológico , Glioblastoma/mortalidade , Glioblastoma/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Sobrevida , Resultado do Tratamento
8.
Tomography ; 1(1): 37-43, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26740971

RESUMO

The standard of care for newly diagnosed glioblastoma (GBM) is surgery, then radiotherapy (RT) with concurrent temozolomide (TMZ), followed by adjuvant TMZ. We hypothesized patients with low diffusivity measured using apparent diffusion coefficient (ADC) histogram analysis evaluated after RT+TMZ, prior to adjuvant TMZ, would have a significantly shorter progression-free (PFS) and overall survival (OS). To test this hypothesis we evaluated 120 patients with newly diagnosed GBM receiving RT+TMZ followed by adjuvant TMZ. MRI was performed after completion of RT+TMZ, prior to initiation of adjuvant TMZ. A double Gaussian mixed model was used to describe the ADC histograms within the enhancing tumor, where ADCL and ADCH were defined as the mean ADC value of the lower and higher Gaussian distribution, respectively. An ADCL value of 1.0 um2/ms and ADCH value of 1.6 um2/ms were used to stratify patients into high and low risk categories. Results suggest patients with low ADCL had significantly shorter PFS (Cox Hazard Ratio = 0.12, P = 0.0006). OS was significantly shorter with low ADCL tumors, showing a median OS of 407 vs. 644 days (Cox Hazard Ratio = 0.31, P = 0.047). ADCH was not predictive of PFS or OS when accounting for age and ADCL. In summary, newly diagnosed glioblastoma patients with low ADCL after completion of RT+TMZ are likely to progress and die earlier than patients with higher ADCL. Results suggest ADC histogram analysis may be useful for patient risk stratification following completion of RT+TMZ.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...